FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Huizhou Auto-Sali Technology Co., Ltd./
  3. 2BFAD-AUTOSALI

2BFAD-AUTOSALIGPS TRACKER

Huizhou Auto-Sali Technology Co., Ltd.

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Mar 27, 2024
Application Purpose
Original Equipment
Date of Application
Mar 27, 2024
Equipment Note
GPS TRACKER
Frequency Range
1850.20000000 - 1909.80000000
Company
Huizhou Auto-Sali Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

1/1 US Agent for Service of ProcessLETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: THREE STONES MEDIA LLC FRN: 0033401761 Contact Name: Sijie Zhang Address: 1200 Broadway St. APT 329, Los Angeles, CA90015 Telephone No: +1 267 909 3692 Email: [email protected] Applicant: Company name: Huizhou Auto-Sali Technology Co., Ltd. Grantee code: 2BFAD FCC ID: 2BFAD-AUTOSALI FRN: 0035066455 Contact Name: Leo lee Address: No.07, 25th Floor, SEG Holiday Plaza, 20 Huizhou Avenue, Huicheng District, Huizhou, Guangdong, China Telephone No: 15815356556 Fax No: N/A Email: [email protected] [Huizhou Auto-Sali Technology Co., Ltd.] certifies that, as of the date of this filing of the application with the TCB, [THREE STONES MEDIA LLC] is our designated US agent for service of process for the above referenced FCC ID. [Huizhou Auto-Sali Technology Co., Ltd.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [THREE STONES MEDIA LLC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicantis aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. 1/1 Date: 22/03/2024 Applicant’s Name: Leo lee US Agent’s Name: Sijie Zhang Title: Manager Title: President Signature Signature

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Huizhou Auto-Sali Technology Co., Ltd. Grantee code: 2BFAD FCC ID: 2BFAD-AUTOSALI Contact Name: Leo lee Address: No.07, 25th Floor, SEG Holiday Plaza, 20 Huizhou Avenue, Huicheng District, Huizhou, Guangdong, China Telephone No: 15815356556 Fax No: N/A Email: [email protected] i. [Huizhou Auto-Sali Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Huizhou Auto-Sali Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. Theapplicantmustsignthiscertification. Huizhou Auto-Sali Technology Co., Ltd. dcertifies that, as of the date of the filing of theapplication, the applicant is notidentified on the Covered List as an entity producing “covered”equipment. Date: 22/03/2024 Applicant’s Name: Leo lee Title: manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

Huizhou Auto-Sali Technology Co., Ltd. Family models difference declaration Product Name: Tablet PC Trade Name: N/A Model Name: V7 Family Model: V2, V3, V4, V5, V6, V8, V9, VG01, VG02, VG03, VG04, VG05, VG06, VG07, VG08, VG09, VP01,VP02, VP03, VP04, VP05, VP06, VP07, VP08, VP09, VB02,VB03,VB04,VB05,VB06,VB07,VB08,VB09,VB100,TR08X, TR08P, TR07X, TR10, TR09, GT02, GT04, GT05, GT08, GT09, GT10, GT10X, GT08X, AT04, AT02, AT05, OBD II Difference declaration: All the model are the same circuit and RF module, except the model names. We (Huizhou Auto-Sali Technology Co., Ltd.) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.), same mechanical structure and design (including product enclosure, materials, etc.), the only difference is theAll the model are the same circuit and RF module, except the model name. Regards, Signature Name: Leo lee Date: 3/22/2024

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization < Huizhou Auto-Sali Technology Co., Ltd. > Company: Huizhou Auto-Sali Technology Co., Ltd. Address: No.07, 25th Floor, SEG Holiday Plaza, 20 Huizhou Avenue, Huicheng District, Huizhou, Guangdong, China Product Name: GPS TRACKER Model Number: V7, V2, V3, V4, V5, V6, V8, V9, VG01, VG02, VG03, VG04, VG05, VG06, VG07, VG08, VG09, VP01,VP02, VP03, VP04, VP05, VP06, VP07, VP08, VP09, VB02,VB03,VB04,VB05,VB06,VB07,VB08,VB09,VB100,TR08X,TR08P, TR07X, TR10, TR09, GT02, GT04, GT05, GT08, GT09, GT10, GT10X, GT08X, AT04, AT02, AT05, OBD II FCC Identifier: 2BFAD-AUTOSALI We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Leo lee Date: 22/03/2024 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 < Huizhou Auto-Sali Technology Co., Ltd.> Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 22/03/2024 Subject: Request for Confidentiality FCC ID: 2BFAD-AUTOSALI To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No Block Diagram ☐ Schematics ☐ Test Report No No Test Setup Photos No User’s Manual ☐ NOTE 1 Internal Photos ☐ NOTE 1 Parts List / Tune Up / BOM List ☐ RF Exposure Info No No Operational Description ☐ Cover Letter(s) No No SOFTWARE SECURITY REQUIREMENTS FOR U- NII DEVICES No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of _180_ days from the date of the Grant of Equipment Authorization and prior to marketing. C5266091_X10_Ed.2 1/1 It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Leo lee Title: Manager

RF Exposure Info

FCC ID: 2BFAD-AUTOSALI Maximum Permissible Exposure (MPE) According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method E (V/m) = d GP**30 Power Density: Pd (W/m²) = 377 2 E E = Electric field (V/m) P = Average RF output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = 2 *377 **30 D GP From the EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained. GSM/GPRS Antenna Type: FPC antenna Gain: GSM 850: 0.24 dBi; PCS 1900: 1.22 dBi; Evaluation result Power density Limits (dBm)(mW)(dBi)Numeric GSM85033.52238.7210.241.060.47070.549 PCS190030.51122.0181.221.320.29561.000 modulation (mW/cm2 )(mW/cm2) Antenna Gain Max tune-up power Signature: Date: 2024-03-26 NAME AND TITLE (Please print or type): alex li/Manager COMPANY (Please print or type): Shenzhen NTEK Testing Technology Co., Ltd./ 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen P.R. China.

Test Report

专业的RF研发机构 深圳市德威玛通讯设备有限公司 深圳研发中心实验室 完成日期:2024年02月01日 项目信息 1 项目:V7 2 频段: 2G:850/900/1800/1900 3 备注:有源测试 4 测试仪器设备 天线项目设计调试说明 工 作 频 段 2G:850/900/1800/1900 测试 工程师 版本 DWM- V1.0 整机图天线匹配电路 整机天线备注说明匹配说明 1. 2G天线:单极天线,并6.8NH电感 2.匹配电路有更改。 E16.8NH E2 0Ω E3 NC 天线开关及匹配电路说明 我司有对天线的原匹配电路做修改 ElementValue E1(0201) 6.8NH E2(0201) 0Ω E3(0201) NC 3D Test Report 2G 85090018001900 Channel 12818925197537124512698885512661810 TRP 21.6823.0724.6524.5925.2425.3927.2627.5928.1728.9128.3928.14 TIS - 100.1 3 - 98.24 - 103.4 1 - 103.2 6 无源增益,效率 天线位置图 專業的RF研發機構 公司地址:深圳市宝安23区创业二路友谊大厦1栋3楼(地铁洪浪北B 出口平安银行后面)

Test Report

Report No.: S24020202804001 Version.1.2 Page 1 of 34 FCC RADIO TEST REPORT FCC ID: 2BFAD-AUTOSALI Product: GPS TRACKER Trade Mark: N/A Model No.: V7 Family Model: V2, V3, V4, V5, V6, V8, V9, VG01, VG02, VG03, VG04, VG05, VG06, VG07, VG08, VG09, VP01,VP02, VP03, VP04, VP05, VP06, VP07, VP08, VP09, VB02,VB03,VB04,VB05,VB06,VB07, VB08,VB09,VB100,TR08X, TR08P, TR07X, TR10, TR09, GT02, GT04, GT05, GT08, GT09, GT10, GT10X, GT08X, AT04, AT02, AT05, OBD II Report No.: S24020202804001 Issue Date: Mar 05, 2024 Prepared for Huizhou Auto-Sali Technology Co., Ltd. No.07, 25th Floor, SEG Holiday Plaza, 20 Huizhou Avenue, Huicheng District, Huizhou, Guangdong, China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen P.R. China Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Report No.: S24020202804001 Version.1.2 Page 2 of 34 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 SUMMARY OF TEST RESULTS ......................................................................................................................... 4 3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5 3.1 FACILITIES..................................................................................................................................................... 5 3.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................. 5 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................... 5 4 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 5 DESCRIPTION OF TEST MODES ..................................................................................................................... 8 6 SETUP OF EQUIPMENT UNDER TEST ........................................................................................................... 9 6.1 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ....................................................................... 9 6.2 SUPPORT EQUIPMENT ............................................................................................................................... 10 6.3 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................. 11 7 TEST REQUIREMENTS .................................................................................................................................... 12 7.1 FIELD STRENGTH OF SPURIOUS RADIATION ...................................................................................... 12 7.2 CONDUCTED OUTPUT POWER ................................................................................................................ 22 7.3 FREQUENCY STABILITY ........................................................................................................................... 24 7.4 PEAK-TO-AVERAGE RATIO ...................................................................................................................... 28 7.5 26DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ..................................................................... 30 7.6 CONDUCTED BAND EDGE ....................................................................................................................... 32 7.7 CONDUCTED SPURIOUS EMISSION AT ANTENNA TERMINAL ......................................................... 33 Report No.: S24020202804001 Version.1.2 Page 3 of 34 1 TEST RESULT CERTIFICATION Applicant’s name .................... : Huizhou Auto-Sali Technology Co., Ltd. Address .................................... : No.07, 25th Floor, SEG Holiday Plaza, 20 Huizhou Avenue, Huicheng District, Huizhou, Guangdong, China Manufacturer's Name ............. : Huizhou Auto-Sali Technology Co., Ltd. Address .................................... : No.07, 25th Floor, SEG Holiday Plaza, 20 Huizhou Avenue, Huicheng District, Huizhou, Guangdong, China Product description Product name .............................. : GPS TRACKER Model and/or type reference .................................... : V7 Family Model ............................... : V2, V3, V4, V5, V6, V8, V9, VG01, VG02, VG03, VG04, VG05, VG06, VG07, VG08, VG09, VP01,VP02, VP03, VP04, VP05, VP06, VP07, VP08, VP09, VB02,VB03,VB04,VB05,VB06,VB07,VB08,VB09,VB100,TR08X, TR08P, TR07X, TR10, TR09, GT02, GT04, GT05, GT08, GT09, GT10, GT10X, GT08X, AT04, AT02, AT05, OBD II Test Sample Number....: S240202028004 Date of Test ................................. : Feb 02, 2024~ Mar 05, 2024 Measurement Procedure Used: APPLICABLE STANDARDS APPLICABLE STANDARD/ TEST PROCEDURE TEST RESULT 47 CFR Part 2, Part 22H, Part 24E ANSI/TIA-603-E-2016 FCC KDB 971168 D01 Power Meas License Digital Systems v03r01 ANSI C63.26:2015 Complied This device described above has been tested by Shenzhen NTEK Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK Testing Technology Co., Ltd., this document may be altered or revised by Shenzhen NTEK Testing Technology Co., Ltd., personnel only, and shall be noted in the revision of the document. The test results of this report relate only to the tested sample identified in this report. Prepared By : Reviewed By : Approved By : Mukzi Lee (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Report No.: S24020202804001 Version.1.2 Page 4 of 34 2 SUMMARY O…

Text truncated - open the document above for the full version.

Test Report

Report No.: S24020202804001 1 / 27 Conducted output power Band Channel Frequency (MHz) Power (dBm) Verdict GPRS1900 1 Slot 512 1850.2 29.86 PASS GPRS1900 1 Slot 661 1880 30.22 PASS GPRS1900 1 Slot 810 1909.8 30.42 PASS GPRS1900 2 Slot 512 1850.2 28.95 PASS GPRS1900 2 Slot 661 1880 29.00 PASS GPRS1900 2 Slot 810 1909.8 28.96 PASS GPRS1900 3 Slot 512 1850.2 26.78 PASS GPRS1900 3 Slot 661 1880 26.87 PASS GPRS1900 3 Slot 810 1909.8 26.97 PASS GPRS1900 4 Slot 512 1850.2 24.93 PASS GPRS1900 4 Slot 661 1880 24.92 PASS GPRS1900 4 Slot 810 1909.8 24.98 PASS GPRS850 1 Slot 128 824.2 32.93 PASS GPRS850 1 Slot 189 836.4 32.97 PASS GPRS850 1 Slot 251 848.8 33.11 PASS GPRS850 2 Slot 128 824.2 31.21 PASS GPRS850 2 Slot 189 836.4 31.00 PASS GPRS850 2 Slot 251 848.8 30.96 PASS GPRS850 3 Slot 128 824.2 30.18 PASS GPRS850 3 Slot 189 836.4 29.97 PASS GPRS850 3 Slot 251 848.8 29.93 PASS GPRS850 4 Slot 128 824.2 28.37 PASS GPRS850 4 Slot 189 836.4 27.87 PASS GPRS850 4 Slot 251 848.8 27.85 PASS Peak-to-Average Ratio Band Channel Frequency (MHz) Result (dB) high Limit (dB) Verdict GPRS1900 512 1850.2 2.70 13 PASS GPRS1900 661 1880 2.72 13 PASS GPRS1900 810 1909.8 2.72 13 PASS GPRS850 128 824.2 2.69 13 PASS GPRS850 189 836.4 2.66 13 PASS GPRS850 251 848.8 2.67 13 PASS GPRS1900 Channel=512 Report No.: S24020202804001 2 / 27 GPRS1900 Channel=661 GPRS1900 Channel=810 Report No.: S24020202804001 3 / 27 GPRS850 Channel=128 GPRS850 Channel=251 Report No.: S24020202804001 4 / 27 GPRS850 Channel=189 Occupied bandwidth Report No.: S24020202804001 5 / 27 Band Channel Frequency (MHz) 99% OBW (kHz) -26dB EBW (kHz) Verdict GPRS1900 512 1850.2 246.781 321.153 PASS GPRS1900 661 1880 245.053 310.783 PASS GPRS1900 810 1909.8 245.242 313.142 PASS GPRS850 128 824.2 237.155 309.532 PASS GPRS850 189 836.4 240.083 314.824 PASS GPRS850 251 848.8 238.292 296.507 PASS GPRS1900 Channel=512 GPRS1900 Channel=661 Report No.: S24020202804001 6 / 27 GPRS1900 Channel=810 GPRS850 Channel=128 Report No.: S24020202804001 7 / 27 GPRS850 Channel=189 GPRS850 Channel=251 Report No.: S24020202804001 8 / 27 Band edge Band Channel Frequency (MHz) Spur Freq (MHz) Spur Level (dBm) Limit (dBm) Verdict GPRS1900 512 1850.2 1849.98 -31.60 -13 PASS GPRS1900 810 1909.8 1910.02 -30.93 -13 PASS GPRS850 128 824.2 823.99 -27.41 -13 PASS GPRS850 251 848.8 849.00 -28.86 -13 PASS GPRS1900 Channel=512 Report No.: S24020202804001 9 / 27 GPRS1900 Channel=810 GPRS850 Channel=128 Report No.: S24020202804001 10 / 27 GPRS850 Channel=251 Out-of-band emissions Report No.: S24020202804001 11 / 27 Band Channel Frequency (MHz) Spur Freq (MHz) Spur Level (dBm) Limit (dBm) Verdict GPRS1900 512 1850.2 26060.60 -19.02 -13 PASS GPRS1900 661 1880 25958.03 -19.85 -13 PASS GPRS1900 810 1909.8 25918.98 -17.97 -13 PASS GPRS850 128 824.2 26057.29 -20.40 -13 PASS GPRS850 189 836.4 26006.33 -21.04 -13 PASS GPRS850 251 848.8 26026.19 -20.53 -13 PASS GPRS1900 Channel=512 GPRS1900 Channel=661 Report No.: S24020202804001 12 / 27 GPRS1900 Channel=810 GPRS850 Channel=189 Report No.: S24020202804001 13 / 27 GPRS850 Channel=128 GPRS850 Channel=251 Report No.: S24020202804001 14 / 27 Conducted output power Band Channel Frequency (MHz) Power (dBm) Verdict GSM1900 512 1850.2 29.90 PASS GSM1900 661 1880 30.25 PASS GSM1900 810 1909.8 30.43 PASS GSM850 128 824.2 32.80 PASS GSM850 189 836.4 32.83 PASS GSM850 251 848.8 33.02 PASS Peak-to-Average Ratio Band Channel Frequency (MHz) Result (dB) high Limit (dB) Verdict GSM1900 512 1850.2 2.64 13 PASS GSM1900 661 1880 2.63 13 PASS GSM1900 810 1909.8 2.63 13 PASS GSM850 128 824.2 2.62 13 PASS GSM850 189 836.4 2.62 13 PASS GSM850 251 848.8 2.62 13 PASS GSM1900 Channel=661 Report No.: S24020202804001 15 / 27 GSM1900 Channel=512 GSM1900 Channel=810 Report No.: S24020202804001 16 / 27 GSM850 Channel=189 GSM850 Channel=128 Report No.: S24020202804001 17 / 27 GSM850 Channel=251 Occupied bandwidth Report No.: S24020202804001 18 / 27 Band Channel Frequency (MHz) 99% OBW (kHz) -26dB EBW (kHz) Verdict GSM1900 512 1850.2 236.303 301.110 PASS GSM1900 661 1880 245.382 303.459 PASS GSM1900 810 1909.8 243.525 304.463 PASS GSM850 128 824.2 233.596 293.146 PASS GSM850 189 836.4 240.802 300.038 PASS GSM850 251 848.8 238.172 302.784 PASS GSM1900 Channel=512 GSM1900 Channel=661 Report No.: S24020202804001 19 / 27 GSM1900 Channel=810 GSM850 Channel=128 Report No.: S24020202804001 20 / 27 GSM850 Channel=189 GSM850 Channel=251 Report No.: S24020202804001 21 / 27 Band edge Band Channel Frequency (MHz) Spur Freq (MHz) Spur Level (dBm) Limit (dBm) Verdict GSM1900 512 1850.2 1850.00 -28.72 -13 PASS GSM1900 810 1909.8 1910.02 -29.20 -13 PASS GSM850 128 824.2 823.99 -27.05 -13 PASS GSM850 251 848.8 849.02 -28.80 -13 PASS GSM1900 Channel=512 Report No.: S24020202804001 22 / 27 GSM1900 Channel=810 GSM850 Channel=128 Report No.: S24020202804001 23 / 27 GSM850 Channel=251 Out-of-band emissions Report No.: S24020202804001 24 / 27 Band Channel Frequency (MHz) Spur Freq (MHz) Spur Level (dBm) Limit (dBm) Verdict GSM1900 512 1850.2 26052.66 -18.67 -13 PASS GSM1900 661 1880 25974.57 -19.28 -13 PASS GSM1900 810 1909.8 25513.99 -19.62 -13 PASS GSM850 128 824.2 25943.47 -20.40 -13 PASS GSM850 189 836.4 25779.35 -21.04 -13 PASS GSM850 251 848.8 26008.98 -20.52 -13 PASS GSM1900 Channel=512 GSM1900 Channel=661 Report No.: S24020202804001 25 / 27 GSM1900 Channel=810 GSM850 Channel=189 Report No.: S24020202804001 26 / 27 GSM850 Channel=128 GSM850 Channel=251 Report No.: S24020202804001 27 / 27

Contact Information

Applicant

leo lee
[email protected]15815356556Fax: N/A

Technical Contact

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]86-755-6115 6588

Shenzhen · China

Non-Technical Contact

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]86-755-6115 6588

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]+86-755-6115-9384

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz1.87499 W247KGXW0.012686 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for frequencies below 1 GHz and EIRP for frequencies above 1 GHz. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.