Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MATTRESS MASSAGE TOPPER OWNER’S MANUAL Installation & Operation - 2 - TABLE OF CONTENTS SAFETY & WARRANTY WARNINGS .............................................................. 3 PRODUCT PARTS LIST.................................................................................. 4 ASSEMBLY INSTRUCTIONS .......................................................................... 5 REMOTE CONTROL INSTRUCTIONS ............................................................. 5 INSTRUCTIONS FOR USE ............................................................................. 6 INSTRUCTIONS FOR MAINTENANCE ........................................................... 7 QUICK QUESTIONS AND ANSWERS ............................................................. 8 - 3 - SAFETY & WARRANTY WARNINGS READ THE FOLLOWING "SAFETY INSTRUCTIONS AND WARNINGS" CAREFULLY BEFORE USING THIS PRODUCT to ensure proper operation. If you do not understand this "Safety Instructions and Warnings", please contact the distributor or technician. Otherwise, personal injury or damage to the user may occur. DANGER: · Always unplug the topper from the electrical outlet immediately after using and before cleaning. · DO NOT reach for a device that has fallen into water. Stand on a dry, clean floor and unplug it immediately when it falls into the water. · DO NOT use while bathing or in a shower. · DO NOT place or store device where it can fall or be pulled into a tub or sink. · DO NOT place in or drop into water or other liquid. · NEVER use pins or other metallic fasteners with this device. · DO NOT use near explosives. · DO NOT forcefully hit the power unit. · DO NOT hit the center black plastic plate and lie down carefully incase hit the head. · Carefully use the heating mode. Serious burns may result. DO NOT use on insensitive skin areas or with poor blood circulation. It can be dangerous for children or incapacitated people to use the heating function unattended. WARNING · A device should never be left unattended when plugged in. Unplug from outlet when not in use, and before putting on or taking off parts or attachments. · Close supervision is necessary when this device is used by, on, or near children, invalids, or disabled persons. · NEVER operate this device if there is a damaged cord or plug, if it is not working properly, or dropped into water. Return the device to a GhostBed Service Center for examination and repair. · Keep the cord away from heated surfaces. · NEVER drop or insert any object into any opening. · DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered. · DO NOT carry this appliance by the supply cord or use cord as a handle. · To disconnect, turn all controls to the off position, then remove plug from outlet. · NEVER operate the device with the air openings blocked. Keep the air openings free of lint, hair, and the like. · Carefully use the heating mode. Serious burns may result. DO NOT use on insensitive skin areas or with poor blood circulation. It can be dangerous for children or incapacitated people to use the heating function unattended. · This device has an overheat protection circuit, if the power is off, please wait for the product to cool down before use. · Do not use massage for more than 30 minutes per day. Warranty Warning Do not open or tamper the power unit, disassemble the topper or remote (except the battery compartment). If all of these parts are tampered with, the warranty will be ineffectiveness. · People with any of the following conditions consult a doctor before using this device: - 4 - Use electronic medical devices implanted in the human body, such as pacemakers, etc.; People who are being treated by a doctor, especially those who suffer from chronic pain and illness. Patients with conditions such as cancer, heart disease, and those in emergency care for medical conditions or recovery. Women who are pregnant. People with osteoporosis or spinal cord injuries. Those with skin or skin conditions Mentally disabled people must operate the device under supervision and never operate alone. · DO NOT allow children to play on this device. DO NOT allow more than one person to use the device at the same time. · If the power cord or plug is damaged in any way, DO NOT use it, disconnect the power cord immediately and call GhostBed to contact technical support for repair or replacement. To prevent damage to the power cord, do not bend, pull, or twist the power cord excessively. It is not recommended that children use this device. · This device should only be carried out by GhostBed's authorized repair personnel. · Do not use this product as a substitute for medical care. · This product is intended for household use only. PRODUCT PARTS LIST This device contains the following product parts, please make sure that the following parts are complete and complete before discarding the packaging. Control Box & Remote Adaptor Control Box & Remote Adaptor 1 2 Removable & Washable cover Carry bag 3 4 - 5 - ASSEMBLY INSTRUCTIONS 1. Open the box. 2. Remove the power unit accessory box and topper. Place the accessory box on a flat surface, taking care not to drop it. Lay the topper flat on the bed or on a clean, flat surface 3. Uncover the topper vacuum bag: Carefully cut the topper vacuum bag with scissors, taking care NOT to cut the topper. Check the spare parts: carefully take out the spare parts box, and count the spare parts. 4. Insert the black tube from the topper into the power unit, making sure the hose connector is flush with the housing. When the topper is ready to use. Insert the round end of the power adapter into the round hole at the end of the power unit and insert the square end of the adapter into the 120 volt outlet. 5. Removable washable cloth cover: can be laid according to actual needs, the open end (including binding) and the thin pad square plastic parts at the same end. When using the cloth cover, be careful not to knock the head on the square pl…
Text truncated - open the document above for the full version.
1/1 GhostBed Inc. US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: GhostBed Inc. FRN: 0035109818 Contact Name: Marc L Werner Address: 7143 W Broward Blvd, Plantation, Florida, 33317, United States Telephone No: 1-954-873-8666 Email: [email protected] Applicant: Company name: GhostBed Inc. Product Description: Massage Topper Grantee code: 2BFEA FCC ID: 2BFEAGBMSTPR39 FRN: 0035109818 Contact Name: Marc L Werner Address: 7143 W Broward Blvd, Plantation, Florida, 33317, United States Telephone No: 1-954-873-8666 Email: [email protected] [GhostBed Inc.] certifies that, as of the date of this filing of the application with the TCB, [GhostBed Inc.] is our designated US agent for service of process for the above referenced FCC ID. [GhostBed Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [GhostBed Inc.] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/04/09 Applicant’s Name: Marc L Werner US Agent’s Name: Marc L Werner Title: CEO-Founder Title: CEO-Founder Signature Signature
C5266091_X24 _Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: GhostBed Inc. Grantee code: 2BFEA FRN: 0035109818 FCC ID: 2BFEAGBMSTPR39 Contact Name: Marc L Werner Address: 7143 W Broward Blvd, Plantation, Florida, 33317, United States Telephone No: 1- 954-873-8666 Fax No: N/A Email: [email protected] i. [GhostBed Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [GhostBed Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [GhostBed Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 04/09/2024 Applicant’s Name: Marc L Werner Title: CEO-Founder Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: GhostBed Inc. Address: 7143 W Broward Blvd, Plantation, Florida, 33317, United States Product Name: Massage Topper Model Number: GBMSTPR39 FCC Identifier: 2BFEAGBMSTPR39 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Marc L Werner Date: 04/09/2024 Title: CEO-Founder Signature of applicant:
C5266091_X10_Ed.1 1/1 GhostBed Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 04/09/2024 Subject: Request for Confidentiality FCC ID: 2BFEAGBMSTPR39 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Marc L Werner Title: CEO-Founder
FCC ID: 2BFEAGBMSTPR39 External photos FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39
36mm 78mm Product Name: Massage Topper Class 2 Power Unit Input: 12V DC 4.0A Lot Number: 2416 FCC ID: 2BFEAGBMSTPR39 Mac: Made in China 蓝牙Mac地址 Label & Location
FCC ID: 2BFEAGBMSTPR39 Internal photos FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 FCC ID: 2BFEAGBMSTPR39 2.4G FHSS Antenna 2.4G FHSS Chip FCC ID: 2BFEAGBMSTPR39 Bluetooth RF Chip Bluetooth RF Antenna FCC ID: 2BFEAGBMSTPR39
Report No.: NTC2403108F01 Dongguan Nore Testing Center Co., Ltd. Address: Building D, Gaosheng Science and Technology park, Hongtu road, Nancheng district, Dongguan city, Guangdong province, China Web: www.ntc-c.com Tel:+86-769-2202 2444 Fax:+86-769-2202 2799 Page 1 of 11 RF EVALUATION TEST REPORT Applicant......................... : GhostBed Inc. Address........................... : 7143 W Broward Blvd, Plantation, Florida, 33317, United States Manufacturer.................... : Zhangzhou Solex Smart Home Co., Ltd. Address........................... : No.12 Shunxiang Road, Gunong Farm, Changtai District, Zhangzhou City, Fujian Province, China Factory........................... : Zhangzhou Solex Smart Home Co., Ltd. Address.......................... : No.12 Shunxiang Road, Gunong Farm, Changtai District, Zhangzhou City, Fujian Province, China Product Name..................... : Massage Topper Brand Name....................... : Model No. ......................... : GBMSTPR39 FCC ID.............................. : 2BFEAGBMSTPR39 Measurement Standard....... : 47 CFR PART 2, Section 2.1091 Receipt Date of Samples.... : March 07, 2024 Date of Tested.................. : March 09, 2024 to March 22, 2024 Date of Report.................. : April 09, 2024 This report shows that above equipment is technically compliant with the requirements of the standards above. All test results in this report apply only to the tested sample(s). Without prior written approval of Dongguan Nore Testing Center Co., Ltd, this report shall not be reproduced except in full. Prepared by Julie Xiao / Project Engineer Approved by Iori Fan / Authorized Signatory Report No.: NTC2403108F01 Page 2 of 11 Table of Contents 1. General Description of EUT ................................................................................................................................ 4 2. Test Facility and Location ................................................................................................................................... 7 3. Applicable Standards and References ................................................................................................................ 7 4. Maximum Permissible Exposure Limit ................................................................................................................ 8 5. RF Exposure Evaluation Results ...................................................................................................................... 11 Report No.: NTC2403108F01 Page 3 of 11 Revision History Report Number Description Issued Date NTC2403108F01 Initial Issue 2024-04-09 Report No.: NTC2403108F01 Page 4 of 11 1. General Description of EUT Product Information Product name: Massage Topper Main Model Name: GBMSTPR39 Additional Model Name: N/A Model Difference: N/A S/N: 2403-1043 Brand Name: Hardware version: Main board: KA10002-038_B Control board: KA10002-039_B Software version: Main board: KA10002-038_A Control board: KA10002-039_A Rating: 120V 48W Typical arrangement: Table-top I/O Port: Refer to user manual Accessories Information Adapter: Model: EA060-1200-4000WU Input: AC 100-240V, 50/60Hz, 1.5A Output: DC 12V, 4A Cable: Power cord(adapter): 1.84m, unshielded, undetachable DC Line: 1.5m, unshielded, undetachable Other: Remote*1 Additional information Note: N/A Remark: All the information above are provided by the manufacturer. More detailed feature of the EUT please refers to the user manual. Report No.: NTC2403108F01 Page 5 of 11 Technical Specification (BLE) Bluetooth Version: V5.0 Frequency Range: 2402-2480MHz Modulation Type: GFSK Number of Channel: 40 Channel Space: 2MHz Antenna Type: PCB antenna Number of Antenna 1 Antenna Gain: 1.36dBi (Declared by the manufacturer) RF PHY Support: 1Mbps Technical Specification (BT) Bluetooth Version: V5.0 Frequency Range: 2402-2480MHz Modulation Type: GFSK, π/4-DQPSK, 8DPSK Number of Channel: 79 Channel Space: 1MHz Antenna Type: PCB antenna Number of Antenna 1 Antenna Gain: 1.36dBi (Declared by the manufacturer) Report No.: NTC2403108F01 Page 6 of 11 Technical Specification (2.4G Function) Frequency Range: 2440MHz Modulation Type: GFSK Number of Channel: 1 Antenna Type: PCB Antenna Antenna Gain: 1.9 dBi (Declared by manufacturer) Report No.: NTC2403108F01 Page 7 of 11 2. Test Facility and Location Test Site : Dongguan Nore Testing Center Co., Ltd. (Dongguan NTC Co., Ltd.) Accreditations and Authorizations : The Laboratory has been assessed and proved to be in compliance with CNAS/CL01 Listed by CNAS, August 13, 2018 The Certificate Registration Number is L5795. The Certificate is valid until August 13, 2024 The Laboratory has been assessed and proved to be in compliance with ISO17025 Listed by A2LA, November 01, 2017 The Certificate Registration Number is 4429.01 Listed by FCC, November 06, 2017 Test Firm Registration Number: 907417 Listed by Industry Canada, June 08, 2017 The Certificate Registration Number. Is 46405-9743A Test Site Location : Building D, Gaosheng Science and Technology Park, Hongtu Road, Nancheng District, Dongguan City, Guangdong Province, China 3. Applicable Standards and References According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: Test Standards: 47 CFR Part 1, 1.1307 47 CFR Part 2, 2.1091 KDB 447498 D04 v01 Report No.: NTC2403108F01 Page 8 of 11 4. Maximum Permissible Exposure Limit According to 47 CFR Part 1, 1.1307, for single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: 47 CFR Part 1, 1.1307 (A) The available maximum time- averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A);…
Text truncated - open the document above for the full version.
Approval sheet Page 1 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 RFANT Pb free Series – RoHS Compliance MULTILAYER CERAMIC ANTENNA Halogens Free Product 2.4 GHz ISM Band RF Application P/N: RFANT2012090A0T *Contents in this sheet are subject to change without prior notice. Approval sheet Page 2 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 FEATURES 1. Surface Mounted Devices with a small dimension of 2.0 x 1.25 x 0.9 mm 3 meet future miniaturization trend. 2. Embedded and LTCC (Low Temperature Co-fired Ceramic) technology is able to future integrate with system design as well as beautifying the housing of final product. 3. High Stability in Temperature / Humidity Change 4. Omni - directional in azimuth APPLICATIONS 1. Bluetooth 2. Wireless LAN 3. HormRF 4. ISM band 2.4GHz working frequency CONSTRUCTION Figure PIN Connection 1 Feeding 2 Soldering terminal DIMENSIONS Figure Symbol Dimension (mm) L 2.0 ± 0.20 W 1.25 ± 0.20 T 0.90 ± 0.10 A 0.25 ± 0.15 12 Approval sheet Page 3 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 ELECTRICAL CHARACTERISTICS RFANT2012090A0T Specification Working Frequency Range 2400 ~ 2500 MHz Gain 1.32 dBi (Typical) VSWR 2.0 max. Polarization Linear Azimuth Beamwidth Omni-directional Impedance 50 Rated Power (max.) 3 Watts Maximum Input Power 5 Watts for 5 minutes Operation Temperature -40°C ~ +85°C Remark: The specification is defined based on the test board dimension as in below SOLDER LAND PATTERN DESIGN Figure Approval sheet Page 4 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 Antenna on Test Board ( FR4 Thickness 0.8mm) Antenna VSWR on Test Board Approval sheet Page 5 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 RADIATION PATTERN Radiation Pattern and Gain were dependent on measurement board design. The specification of RFANT2012090A0T antenna was measured based on the PCB size and installation position as shown in the below figure Test Board (XZ plane) + Z + X - Z - X Approval sheet Page 6 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 ZX plane ZY plane XY plane Frequency [MHz] Max Value [dB] Average [dB] Max Value [dB] Average [dB] Max Value [dB] Average [dB] 2400 0.89 -4.72 1.07 -0.64 -0.03 -3.73 2450 -0.11 -4.90 1.36 -0.54 0.20 -3.54 2500 -0.72 -5.43 0.95 -1.00 0.09 -3.77 (YZ plane) (XY plane) + Z - Z - Y + Y + X + Y - X - Y Approval sheet Page 7 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 RELIABILITY TEST Test item Test condition / Test method Specification Solderability JIS C 0050-4.6 JESD22-B102D *Solder bath temperature:235 5C *Immersion time:2 0.5 sec Solder:Sn3Ag0.5Cu for lead-free At least 95% of a surface of each terminal electrode must be covered by fresh solder. Leaching (Resistance to dissolution of metallization) IEC 60068-2-58 *Solder bath temperature:260 5C *Leaching immersion time:30 0.5 sec Solder : SN63A Loss of metallization on the edges of each electrode shall not exceed 25%. Resistance to soldering heat JIS C 0050-5.4 *Preheating temperature:120~150°C, 1 minute. *Solder temperature:2705C *Immersion time:101 sec Solder:Sn3Ag0.5Cu for lead-free Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Loss of metallization on the edges of each electrode shall not exceed 25%. Drop Test JIS C 0044 Customer’s specification. *Height:75 cm *Test Surface:Rigid surface of concrete or steel. *Times:6 surfaces for each units;2times for each side. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Vibration JIS C 0040 *Frequency:10Hz~55Hz~10Hz(1min) *Total amplitude:1.5mm *Test times:6hrs.(Two hrs each in three mutually perpendicular directions) No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Adhesive Strength of Termination JIS C 0051- 7.4.3 *Pressurizing force: 5N(≦0603);10N(>0603) *Test time:10±1 sec No remarkable damage or removal of the termination. Bending test JIS C 0051- 7.4.1 The middle part of substrate shall be pressurized by means of the pressurizing rod at a rate of about 1 mm/s per second until the deflection becomes 1mm/s and then pressure shall be maintained for 51 sec. Measurement to be made after keeping at room temperature for 242 hours No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Approval sheet Page 8 of 9 ASC_RFANT2012090A0T_V02 Mar. 2017 Temperature cycle JIS C 0025 1. 303 minutes at -40C3C, 2. 10~15 minutes at room temperature, 3. 303 minutes at +85C3C, 4. 10~15 minutes at room temperature, Total 100 continuous cycles Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. High temperature JIS C 0021 *Temperature:85C2C *Test duration:1000+24/-0 hours Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Humidity (steady conditions) JIS C 0022 *Humidity:90% to 95% R.H. *Temperature:402C *Time:1000+24/-0 hrs. Measurement to be made after keeping at room temperature for 242 hrs ※ 500hrs measuring the first data then 1000hrs data No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Low temperature JIS C 0020 *Temperature:-40C2C *Test duration:1000+24/-0 hours Measurement to be made after keeping at room temperature for 242 hrs No mechanical damage.…
Text truncated - open the document above for the full version.
Report No.: NTC2403109FV00 Dongguan Nore Testing Center Co., Ltd. Address: Building D, Gaosheng Science and Technology park, Hongtu road, Nancheng district, Dongguan city, Guangdong province, China Web: www.ntc-c.com Tel:+86-769-2202 2444 Fax:+86-769-2202 2799 Page 1 of 36 FCC RADIO TEST REPORT Applicant......................... : GhostBed Inc. Address........................... : 7143 W Broward Blvd, Plantation, Florida, 33317, United States Manufacturer.................... : Zhangzhou Solex Smart Home Co., Ltd. Address........................... : No.12 Shunxiang Road, Gunong Farm, Changtai District, Zhangzhou City, Fujian Province, China Factory........................... : Zhangzhou Solex Smart Home Co., Ltd. Address.......................... : No.12 Shunxiang Road, Gunong Farm, Changtai District, Zhangzhou City, Fujian Province, China Product Name................... : Massage Topper Brand Name..................... : Model No. ....................... : GBMSTPR39 FCC ID................................ : 2BFEAGBMSTPR39 Measurement Standard....... : 47 CFR FCC Part 15, Subpart C (Section 15.247) Receipt Date of Samples.... : March 07, 2024 Date of Tested.................. : March 09, 2024 to March 22, 2024 Date of Report.................. : April 09, 2024 This report shows that above equipment is technically compliant with the requirements of the standards above. All test results in this report apply only to the tested sample(s). Without prior written approval of Dongguan Nore Testing Center Co., Ltd, this report shall not be reproduced except in full. Prepared by Julie Xiao / Project Engineer Approved by Iori Fan / Authorized Signatory Report No.: NTC2403109FV00 Page 2 of 36 Table of Contents 1. Summary of Test Result ...................................................................................................................................... 4 2. General Description of EUT ................................................................................................................................ 5 3. Test Channels and Modes Detail ........................................................................................................................ 8 4. Configuration of EUT ........................................................................................................................................... 8 5. Modification of EUT ............................................................................................................................................. 8 6. Description of Support Device ............................................................................................................................. 9 7. Test Facility and Location ................................................................................................................................. 10 8. Applicable Standards and References .............................................................................................................. 11 9. Deviations and Abnormalities from Standard Conditions ................................................................................. 11 10. Test Conditions ............................................................................................................................................... 12 11. Measurement Uncertainty ............................................................................................................................... 13 12. Sample Calculations ....................................................................................................................................... 14 13. Test Items and Results ................................................................................................................................... 15 13.1 Conducted Emissions Measurement ............................................................................................................ 15 13.2 Maximum Conducted Output Power Measurement ...................................................................................... 19 13.3 6dB Bandwidth Measurement ....................................................................................................................... 21 13.4 Power Spectral Density Measurement ......................................................................................................... 23 13.5 Band Edge and Conducted Spurious Emissions Measurement ................................................................... 24 13.6 Radiated Spurious Emissions and Restricted Bands Measurement ............................................................ 28 13.7 Antenna Requirement ................................................................................................................................... 35 14. Test Equipment List......................................................................................................................................... 36 Report No.: NTC2403109FV00 Page 3 of 36 Revision History Report Number Description Issued Date NTC2403109FV00 Initial Issue 2024-04-09 Report No.: NTC2403109FV00 Page 4 of 36 1. Summ…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 922.00 µW |