Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ShenzhenSYDNetworkTechnologyCo.,Ltd 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:ShenzhenSYDNetworkTechnologyCo.,Ltd Address:4F,BuildingNO.4,LianchuangScienceandTechnologyPark,21stBulanRd,Nanwan Street,LonggangDistrict,Shenzhen,China ProductName:PortablePowerStation FCCID:2BFF7SYD2400 Model(s):SYD2400,N052,F2400,P2400,2400A,G2400,AS2400JP,HS2400,T2400,S2400, GK-2400,M2400,PS2400,PH2400 2.911(d)(5)(i)EquipmentType We,[ShenzhenSYDNetworkTechnologyCo.,Ltd]certifythattheequipmentforwhichauthorization issoughtthroughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:HongnianLiuDate:2024-09-05 TitleandCompanyname:MANAGER/ShenzhenSYDNetworkTechnologyCo.,Ltd NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhenSYDNetworkTechnologyCo.,Ltd 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:ShenzhenSYDNetworkTechnologyCo.,Ltd Address:4F,BuildingNO.4,LianchuangScienceandTechnologyPark,21stBulanRd,Nanwan Street,LonggangDistrict,Shenzhen,China ProductName:PortablePowerStation FCCID:2BFF7SYD2400 Model(s):SYD2400,N052,F2400,P2400,2400A,G2400,AS2400JP,HS2400,T2400,S2400, GK-2400,M2400,PS2400,PH2400 2.911(d)(5)(ii)Applicantfiling We,[ShenzhenSYDNetworkTechnologyCo.,Ltd]certifythat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedonthe“CoveredList”,establishedpursuantto§1.50002 ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:HongnianLiuDate:2024-09-05 TitleandCompanyname:MANAGER/ShenzhenSYDNetworkTechnologyCo.,Ltd “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
- Shenzhen SYD Network Technology Co.,Ltd - Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 3/20/24 u.S.Aqent Desiqnation (Shenzhen SYD Network Technology Co.,Ltd] acknowledges their consent f or the following contact located in Name and company of U.S. agent: Linkwld ( FCC ID:2BFF7SYD2400 LLC P hysical U.S. address of agent: 1942 Broadway St. STE 314C, B oulder, CO, 80302, US FRN of U.S. agent: 0033625682 E mail address of U.S. agent: [email protected] Linkwld LLC acknowledges their obligation to accept service of process on behalf of [Shenzhen SYD Networ k Technology Co.,Ltd]. [Sh enzhen SYD N etwork Technology Co.,Ltd] with the FRN [003513188 7 ] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee h as p ermanently terminated all marketing and importation of the applicable equipment within the U.S., or the c oncl usion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is l a t e r . By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2 . 9 1 1 ( d ) ( 7 ) . The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 9 86446 D01. A n expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, 岂了一,已 (p)[ 16 · z: - igellVISn[PP2U「OO寸 Lllil玉 Signature [Name] Liu Hongnian [Tit i e]M : : ? / [Co rnpany}-Sfienzhen SYD Network Technology Co.,Ltd 飞十多匕 Signature [Name of U.S. agent] Timothy Zhu
- Shenzhen SYD Network Technology Co.,Ltd - Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 3/20/24 u.S.Aqent Desiqnation (Shenzhen SYD Network Technology Co.,Ltd] acknowledges their consent f or the following contact located in Name and company of U.S. agent: Linkwld ( FCC ID:2BFF7SYD2400 LLC P hysical U.S. address of agent: 1942 Broadway St. STE 314C, B oulder, CO, 80302, US FRN of U.S. agent: 0033625682 E mail address of U.S. agent: [email protected] Linkwld LLC acknowledges their obligation to accept service of process on behalf of [Shenzhen SYD Networ k Technology Co.,Ltd]. [Sh enzhen SYD N etwork Technology Co.,Ltd] with the FRN [003513188 7 ] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee h as p ermanently terminated all marketing and importation of the applicable equipment within the U.S., or the c oncl usion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is l a t e r . By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2 . 9 1 1 ( d ) ( 7 ) . The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 9 86446 D01. A n expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, 岂了一,已 (p)[ 16 · z: - igellVISn[PP2U「OO寸 Lllil玉 Signature [Name] Liu Hongnian [Tit i e]M : : ? / [Co rnpany}-Sfienzhen SYD Network Technology Co.,Ltd 飞十多匕 Signature [Name of U.S. agent] Timothy Zhu
ShenzhenSYDNetworkTechnologyCo.,Ltd LetterofAuthorization Company:ShenzhenSYDNetworkTechnologyCo.,Ltd Address:4F,BuildingNO.4,LianchuangScienceandTechnologyPark,21stBulan Rd,NanwanStreet,LonggangDistrict,Shenzhen,China ProductName:PortablePowerStation ModelNumber(s):SYD2400,N052,F2400,P2400,2400A,G2400,AS2400JP, HS2400,T2400,S2400,GK-2400,M2400,PS2400,PH2400 ProductDescription:PortablePowerStation WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2024-09-05 Name:HongnianLiu Title:MANAGER Company:ShenzhenSYDNetworkTechnologyCo.,Ltd
ShenzhenSYDNetworkTechnologyCo.,Ltd DeclarationonModelDifferences We, ShenzhenSYDNetworkTechnologyCo.,Ltd 4F,BuildingNO.4,LianchuangScienceandTechnologyPark,21stBulanRd,NanwanStreet, LonggangDistrict,Shenzhen,China Declarethatthefollowingproduct(s): FCCID:2BFF7SYD2400 ProductName:PortablePowerStation ModelNo.:SYD2400,N052,F2400,P2400,2400A,G2400,AS2400JP,HS2400,T2400, S2400,GK-2400,M2400,PS2400,PH2400 Utilizetheidenticalcircuitdesign,PCBlayout,shieldingandinterfacewith(SYD2400),only themodelnumberandshelldifferent.Thereforethisapplicationcanberegardedasidentical inperformancetothesubmittedtestsample. Themanufacturerwouldtakealltheresponsibilitiesfortheaboveproduct(s). Forandonbehalfof Authorizedperson Name:HongnianLiu Position:MANAGER Dateofissue:2024-09-05 *IherebydeclarethatIamentitledtosignonbehalfoftheapplicantandthattheinformationsuppliediscorrectandcomplete.
ShenzhenSYDNetworkTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024-09-05 Subject;RequestforConfidentiality FCCID:2BFF7SYD2400 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription SWSECURITYDESCRIPTION PartsList Tuneup Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:HongnianLiu Title:MANAGER
LabelLocationOnEUT
LabelLocationOnEUT
RFEXPOSUREEVALUATION KDB447498D01MobileandPortableDevicesRFExposureProceduresand EquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b) EUTSpecification FCCID2BFF7SYD2400 EUTPortablePowerStation Frequencyband(Operating)BT:2.402GHz~2.480GHz WLAN:2.412GHz~2.462GHz RLAN:5.180GHz~5.240GHz RLAN:5.260GHz~5.320GHz RLAN:5.500GHz~5.700GHz RLAN:5.745GHz~5.825GHz Others: DevicecategoryPortable(<20cmseparation) Mobile(>20cmseparation) Others___ ExposureclassificationOccupational/Controlledexposure(S=5mW/cm2) GeneralPopulation/Uncontrolledexposure (S=1mW/cm2) AntennadiversitySingleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Antennagain(Max)Wi-Fi2.4G/BT:4.16dBi EvaluationappliedMPEEvaluation SAREvaluation LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainMw G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantenna andtotalpowerinputtotheantenna,throughthecalculation,wewillknowthe distancewheretheMPElimitisreached. MaxMeasurementResult Operating Mode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power densityat 20cm Power densityLimits (mW/cm2) (dBm)(dBm)(dBm)(dBi)(mW/cm2) BLE3.063.06±14.064.160.00131 WiFi2.4G12.7912.79±113.794.160.01241 TheBLEandWiFi2.4Gcan’tsimultaneoustransmission. Result:PASS.
Page1of25 AppendixTestData ReportNo.:1815C40037012501TestSampleNo.:1-2-2 StartTestDate: 2024.08.26FinishTestDate: 2024.08.26 TestEngineer:Auditor: Temperature:25.3°CRelativeHumidity:48% Pressure:101kPa AppendixA:6dBBandwidth TestResult TestModeAntennaFrequency[MHz] 6dBBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt124020.7082401.6682402.3760.5PASS BLE_1MAnt124400.7122439.6642440.3760.5PASS BLE_1MAnt124800.7122479.6682480.3800.5PASS BLE_2MAnt124021.1442401.4442402.5880.5PASS BLE_2MAnt124401.2922439.3762440.6680.5PASS BLE_2MAnt124801.2682479.3802480.6480.5PASS Page2of25 TestGraphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS Page3of25 BLE_2M-Ant1-2402-PASS BLE_2M-Ant1-2440-PASS BLE_2M-Ant1-2480-PASS Page4of25 AppendixB:99%OccupiedBandwidth TestResult TestModeAntennaFrequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt124021.10172401.47132402.5730------ BLE_1MAnt124401.10002439.47592440.5759------ BLE_1MAnt124801.09912479.47762480.5767------ BLE_2MAnt124022.09242400.97752403.0699------ BLE_2MAnt124402.07172438.98792441.0596------ BLE_2MAnt124802.07082478.97922481.0500------ Page5of25 TestGraphs BLE_1M-Ant1-2402 BLE_1M-Ant1-2440 BLE_1M-Ant1-2480 Page6of25 BLE_2M-Ant1-2402 BLE_2M-Ant1-2440 BLE_2M-Ant1-2480 Page7of25 AppendixC:Maximumconductedoutputpower TestResultPeak TestModeAntennaFrequency[MHz] ConductedPeak Power[dBm] Conducted Limit[dBm] Verdict BLE_1MAnt124022.81≤30PASS BLE_1MAnt124402.46≤30PASS BLE_1MAnt124801.90≤30PASS BLE_2MAnt124023.06≤30PASS BLE_2MAnt124402.84≤30PASS BLE_2MAnt124801.99≤30PASS Page8of25 TestGraphsPeak BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS Page9of25 BLE_2M-Ant1-2402-PASS BLE_2M-Ant1-2440-PASS BLE_2M-Ant1-2480-PASS Page10of25 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt12402-11.08≤8.00PASS BLE_1MAnt12440-11.27≤8.00PASS BLE_1MAnt12480-11.66≤8.00PASS BLE_2MAnt12402-12.79≤8.00PASS BLE_2MAnt12440-13.07≤8.00PASS BLE_2MAnt12480-13.90≤8.00PASS Page11of25 TestGraphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS Page12of25 BLE_2M-Ant1-2402-PASS BLE_2M-Ant1-2440-PASS BLE_2M-Ant1-2480-PASS Page13of25 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChName Frequency [MHz] RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1Low24021.07-50.17≤-18.93PASS BLE_1MAnt1High24800.74-55.97≤-19.26PASS BLE_2MAnt1Low24020.96-48.68≤-19.04PASS BLE_2MAnt1High2480-1.29-55.29≤-21.29PASS Page14of25 TestGraphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2480-PASS BLE_2M-Ant1-2402-PASS Page15of25 BLE_2M-Ant1-2480-PASS Page16of25 AppendixF:ConductedSpuriousEmission TestResult TestModeAntenna Frequency [MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1MAnt124020~Reference0.350.35---PASS BLE_1MAnt1240230~10000.35-67.51≤-19.65PASS BLE_1MAnt124021000~265000.35-37.76≤-19.65PASS BLE_1MAnt124400~Reference0.540.54---PASS BLE_1MAnt1244030~10000.54-67.57≤-19.46PASS BLE_1MAnt124401000~265000.54-53.51≤-19.46PASS BLE_1MAnt124800~Reference0.470.47---PASS BLE_1MAnt1248030~10000.47-68.46≤-19.53PASS BLE_1MAnt124801000~265000.47-44.9≤-19.53PASS BLE_2MAnt124020~Reference0.440.44---PASS BLE_2MAnt1240230~10000.44-68.37≤-19.56PASS BLE_2MAnt124021000~265000.44-45.07≤-19.56PASS BLE_2MAnt124400~Reference-1.10-1.10---PASS BLE_2MAnt1244030~1000-1.10-68.34≤-21.1PASS BLE_2MAnt124401000~26500-1.10-47.64≤-21.1PASS BLE_2MAnt124800~Reference-2.13-2.13---PASS BLE_2MAnt1248030~1000-2.13-66.21≤-22.13PASS BLE_2MAnt124801000~26500-2.13-48.7≤-22.13PASS Page17of25 TestGraphs BLE_1M-Ant1-2402-0~Reference-PASS BLE_1M-Ant1-2402-30~1000-PASS BLE_1M-Ant1-2402-1000~26500-PASS Page18of25 BLE_1M-Ant1-2440-0~Reference-PASS BLE_1M-Ant1-2440-30~1000-PASS BLE_1M-Ant1-2440-1000~26500-PASS Page19of25 BLE_1M-Ant1-2480-0~Reference-PASS BLE_1M-Ant1-2480-30~1000-PASS BLE_1M-Ant1-2480-1000~26500-PASS Page20of25 BLE_2M-Ant1-2402-0~Reference-PASS BLE_2M-Ant1-2402-30~1000-PASS BLE_2M-Ant1-2402-1000~26500-PASS Page21of25 BLE_2M-Ant1-2440-0~Reference-PASS BLE_2M-Ant1-2440-30~1000-PASS BLE_2M-Ant1-2440-1000~26500-PASS Page22of25 BLE_2M-Ant1-2480-0~Reference-PASS BLE_2M-Ant1-2480-30~1000-PASS BLE_2M-Ant1-2480-1000~26500-PASS Page23of25 AppendixG:DutyCycle TestResult TestModeAntennaFrequency[MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor[dB] BLE_1MAnt124020.000.00100.000.00 BLE_1MAnt124400.000.00100.000.00 BLE_1MAnt124800.000.00100.000.00 BLE_2MAnt1240211.0011.00100.000.00 BLE_2MAnt1244019.0019.00100.000.00 BLE_2MAnt1248019.0019.00100.000.00 Page24of25 TestGraphs NTNV-BLE_1M-Ant1-2402 NTNV-BLE_1M-Ant1-2440 NTNV-BLE_1M-Ant1-2480 Page25of25 NTNV-BLE_2M-Ant1-2402 NTNV-BLE_2M-Ant1-2440 NTNV-BLE_2M-Ant1-2480 ---End---
ReportNo.:1815C40037012501Page1of33 FCCID:2BFF7SYD2400 FCCTestReport Applicant:ShenzhenSYDNetworkTechnologyCo.,Ltd Address: 4F,BuildingNO.4,LianchuangScienceand TechnologyPark,21stBulanRd,NanwanStreet, LonggangDistrict,Shenzhen,China ProductName:PortablePowerStation ReportDate:Sept.05,2024 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:1815C40037012501Page2of33 FCCID:2BFF7SYD2400 Contents 1.GeneralInformation.................................................................................................................................6 1.1.ClientInformation...........................................................................................................................6 1.2.DescriptionofDevice(EUT)..........................................................................................................6 1.3.AuxiliaryEquipmentUsedDuringTest..........................................................................................7 1.4.Operationchannellist....................................................................................................................7 1.5.DescriptionofTestModes.............................................................................................................8 1.6.MeasurementUncertainty.............................................................................................................8 1.7.TestSummary................................................................................................................................8 1.8.DescriptionofTestFacility.............................................................................................................9 1.9.Disclaimer......................................................................................................................................9 1.10.TestEquipmentList...................................................................................................................10 2.Antennarequirement..............................................................................................................................12 2.1.Conclusion...................................................................................................................................12 3.ConductedEmissionatACpowerline..................................................................................................13 3.1.EUTOperation.............................................................................................................................13 3.2.TestSetup....................................................................................................................................13 3.3.TestData......................................................................................................................................14 4.OccupiedBandwidth..............................................................................................................................16 4.1.EUTOperation.............................................................................................................................16 4.2.TestSetup....................................................................................................................................17 4.3.TestData......................................................................................................................................17 5.MaximumConductedOutputPower......................................................................................................18 5.1.EUTOperation.............................................................................................................................18 5.2.TestSetup....................................................................................................................................18 5.3.TestData......................................................................................................................................18 6.PowerSpectralDensity..........................................................................................................................19 6.1.EUTOperation.............................................................................................................................19 6.2.TestSetup....................................................................................................................................19 6.3.TestData......................................................................................................................................19 7.Emissionsinnon-restrictedfrequencybands.......................................................................................20 7.1.EUTOperation.............................................................................................................................20 7.2.TestSetup....................................................................................................................................20 7.3.TestData......................................................................................................................................20 8.Bandedgeemissions(Radiated)..........................................................................................................21 8.1.EUTOperation.............................................................................................................................21 8.2.TestSetup....................................................................................................................................22 8.3.TestData......................................................................................................................................23 9.Emissionsinfrequencybands(below1GHz).......................................................................................24 9.1.EUTOperation.............................................................................................................................24 9.2.…
Text truncated - open the document above for the full version.
Page 1 of 59 AppendixTestData ReportNo:1815C40037012502TestSampleNO:1-2-2 StartTestDate:2024.08.20FinishTestDate:2024.08.20 TestEngineer:Auditor: Temperature:24.3 °C RelativeHumidity:56% Pressure:101kPa AppendixA:DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt124128.282408.202416.480.5PASS 11BAnt124378.082432.922441.000.5PASS 11BAnt124627.882457.962465.840.5PASS 11GAnt1241215.962404.202420.160.5PASS 11GAnt1243716.362428.762445.120.5PASS 11GAnt1246216.322453.802470.120.5PASS 11N20SISOAnt1241217.202403.562420.760.5PASS 11N20SISOAnt1243717.602428.162445.760.5PASS 11N20SISOAnt1246217.562453.202470.760.5PASS 11N40SISOAnt1242233.842406.322440.160.5PASS 11N40SISOAnt1243736.162418.762454.920.5PASS 11N40SISOAnt1245236.402433.762470.160.5PASS Page 2 of 59 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS Page 3 of 59 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS Page 4 of 59 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS Page 5 of 59 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS Page 6 of 59 11N20SISO-Ant1-2462-PASS 11N40SISO-Ant1-2422-PASS Page 7 of 59 11N40SISO-Ant1-2437-PASS 11N40SISO-Ant1-2452-PASS Page 8 of 59 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntenna Channel Frequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1241212.8272405.72632418.5534------ 11BAnt1243713.0272430.40662443.4336------ 11BAnt1246212.9872455.48652468.4735------ 11GAnt1241217.1032403.48852420.5914------ 11GAnt1243716.6232428.68832445.3117------ 11GAnt1246216.6632453.56842470.2318------ 11N20SISOAnt1241217.7822403.12892420.9111------ 11N20SISOAnt1243717.9022428.00902445.9111------ 11N20SISOAnt1246217.8622453.04902470.9111------ 11N40SISOAnt1242235.9642404.01802439.9820------ 11N40SISOAnt1243735.9642418.85812454.8222------ 11N40SISOAnt1245236.6032433.45852470.0619------ Page 9 of 59 TestGraphs 11B-Ant1-2412 11B-Ant1-2437 Page 10 of 59 11B-Ant1-2462 11G-Ant1-2412 Page 11 of 59 11G-Ant1-2437 11G-Ant1-2462 Page 12 of 59 11N20SISO-Ant1-2412 11N20SISO-Ant1-2437 Page 13 of 59 11N20SISO-Ant1-2462 11N40SISO-Ant1-2422 Page 14 of 59 11N40SISO-Ant1-2437 11N40SISO-Ant1-2452 Page 15 of 59 AppendixC:Maximumconductedoutputpower TestResultAverage Test Mode Antenna Frequency [MHz] Set Power Average power [dBm] Duty Cycle [%] DC Factor [dB] Result [dBm] Limit [dBm] Verdict 11BAnt12412NA12.28100.000.0012.28≤30.00PASS 11BAnt12437NA11.76100.000.0011.76≤30.00PASS 11BAnt12462NA11.48100.000.0011.48≤30.00PASS 11GAnt12412NA12.79100.000.0012.79≤30.00PASS 11GAnt12437NA12.32100.000.0012.32≤30.00PASS 11GAnt12462NA11.48100.000.0011.48≤30.00PASS 11N20SISOAnt12412NA12.73100.000.0012.73≤30.00PASS 11N20SISOAnt12437NA12.20100.000.0012.20≤30.00PASS 11N20SISOAnt12462NA11.46100.000.0011.46≤30.00PASS 11N40SISOAnt12422NA12.31100.000.0012.31≤30.00PASS 11N40SISOAnt12437NA12.19100.000.0012.19≤30.00PASS 11N40SISOAnt12452NA11.70100.000.0011.70≤30.00PASS Page 16 of 59 TestGraphsAverage 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS Page 17 of 59 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS Page 18 of 59 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS Page 19 of 59 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS Page 20 of 59 11N20SISO-Ant1-2462-PASS 11N40SISO-Ant1-2422-PASS
Page 21 of 59 11N40SISO-Ant1-2437-PASS 11N40SISO-Ant1-2452-PASS Page 22 of 59 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/3kHz]Limit[dBm/3kHz]Verdict 11BAnt12412-18.80≤8.00PASS 11BAnt12437-19.42≤8.00PASS 11BAnt12462-19.36≤8.00PASS 11GAnt12412-20.26≤8.00PASS 11GAnt12437-20.87≤8.00PASS 11GAnt12462-21.55≤8.00PASS 11N20SISOAnt12412-20.15≤8.00PASS 11N20SISOAnt12437-21.11≤8.00PASS 11N20SISOAnt12462-21.10≤8.00PASS 11N40SISOAnt12422-23.58≤8.00PASS 11N40SISOAnt12437-24.17≤8.00PASS 11N40SISOAnt12452-24.80≤8.00PASS Page 23 of 59 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS Page 24 of 59 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS Page 25 of 59 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS Page 26 of 59 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS Page 27 of 59 11N20SISO-Ant1-2462-PASS 11N40SISO-Ant1-2422-PASS Page 28 of 59 11N40SISO-Ant1-2437-PASS 11N40SISO-Ant1-2452-PASS Page 29 of 59 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChName Frequency [MHz] RefLevel[dBm]Result[dBm]Limit[dBm]Verdict 11BAnt1Low24122.53-45.8≤-27.47PASS 11BAnt1High24622.72-46.41≤-27.28PASS 11GAnt1Low2412-0.47-39.56≤-30.47PASS 11GAnt1High2462-1.74-45.95≤-31.74PASS 11N20SISOAnt1Low2412-0.99-39.91≤-30.99PASS 11N20SISOAnt1High2462-1.97-46.38≤-31.97PASS 11N40SISOAnt1Low2422-3.92-43.68≤-33.92PASS 11N40SISOAnt1High2452-4.78-43.56≤-34.78PASS Page 30 of 59 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2462-PASS Page 31 of 59 11G-Ant1-2412-PASS 11G-Ant1-2462-PASS Page 32 of 59 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2462-PASS Page 33 of 59 11N40SISO-Ant1-2422-PASS 11N40SISO-Ant1-2452-PASS Page 34 of 59 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt124120~Reference1.461.46---PASS 11BAnt1241230~10001.46-57.74≤-28.54PASS 11BAnt124121000~265001.46-43.62≤-28.54PASS 11BAnt124370~Reference1.761.76---PASS 11BAnt1243730~10001.76-57.37≤-28.24PASS 11BAnt124371000~265001.76-44.22≤-28.24PASS 11BAnt124620~Reference1.091.09---PASS 11BAnt1246230~10001.09-57.96≤-28.91PASS 11BAnt124621000~265001.09-43.87≤-28.91PASS 11GAnt124120~Reference-1.40-1.40---PASS 11GAnt1241230~1000-1.40-56.72≤-31.4PASS 11GAnt124121000~26500-1.40-43.97≤-31.4PASS 11GAnt124370~Reference-1.55-1.55---PASS 11GAnt1243730~1000-1.55-58.57≤-31.55PASS 11GAnt124371000~26500-1.55-43.91≤-31.55PASS 11GAnt124620~Reference-2.59-2.59---PASS 11GAnt1246230~1000-2.59-57.88≤-32.59PASS 11GAnt124621000~26500-2.59-43.85≤-32.59PASS 11N20SISOAnt124120~Reference-0.87-0.87---PASS 11N20SISOAnt1241230~1000-0.87-58.48≤-30.87PASS 11N20SISOAnt124121000~26500-0.87-44.15≤-30.87PASS 11N20SISOAnt124370~Reference-2.39-2.39---PASS 11N20SISOAnt1243730~1000-2.39-57.71≤-32.39PASS 11N20SISOAnt124371000~26500-2.39-44.03≤-32.39PASS 11N20SISOAnt124620~Reference-3.11-3.11---PASS 11N20SISOAnt1246230~1000-3.11-57.38≤-33.11PASS 11N20SISOAnt124621000~26500-3.11-43.64≤-33.11PASS 11N40SISOAnt124220~Reference-4.44-4.44---PASS 11N40SISOAnt1242230~1000-4.44-57.48≤-34.44PASS 11N40SISOAnt124221000~26500-4.44-44.24≤-34.44PASS 11N40SISOAnt124370~Reference-4.86-4.86---PASS 11N40SISOAnt1243730~1000-4.86-57.27≤-34.86PASS 11N40SISOAnt124371000~26500-4.86-42.29≤-34.86PASS 11N40SISOAnt124520~Reference-4.87-4.87---PASS 11N40SISOAnt1245230~1000-4.87-58.14≤-34.87PASS 11N40SISOAnt124521000~26500-4.87-43.47≤-34.87PASS Page 35 of 59 TestGraphs 11B-Ant1-2412-0~Reference-PASS 11B-Ant1-2412-30~1000-PASS Page 36 of 59 11B-Ant1-2412-1000~26500-PASS 11B-Ant1-2437-0~Reference-PASS Page 37 of 59 11B-Ant1-2437-30~1000-PASS 11B-Ant1-2437-1000~26500-PASS Page 38 of 59 11B-Ant1-2462-0~Reference-PASS 11B-Ant1-2462-30~1000-PASS Page 39 of 59 11B-Ant1-2462-1000~26500-PASS 11G-Ant1-2412-0~Reference-PASS Page 40 of 59 11G-Ant1-2412-30~1000-PASS 11G-Ant1-2412-1000~26500-PASS
Page 41 of 59 11G-Ant1-2437-0~Reference-PASS 11G-Ant1-2437-30~1000-PASS Page 42 of 59 11G-Ant1-2437-1000~26500-PASS 11G-Ant1-2462-0~Reference-PASS Page 43 of 59 11G-Ant1-2462-30~1000-PASS 11G-Ant1-2462-1000~26500-PASS Page 44 of 59 11N20SISO-Ant1-2412-0~Reference-PASS 11N20SISO-Ant1-2412-30~1000-PASS Page 45 of 59 11N20SISO-Ant1-2412-1000~26500-PASS 11N20SISO-Ant1-2437-0~Reference-PASS Page 46 of 59 11N20SISO-Ant1-2437-30~1000-PASS 11N20SISO-Ant1-2437-1000~26500-PASS Page 47 of 59 11N20SISO-Ant1-2462-0~Reference-PASS 11N20SISO-Ant1-2462-30~1000-PASS Page 48 of 59 11N20SISO-Ant1-2462-1000~26500-PASS 11N40SISO-Ant1-2422-0~Reference-PASS Page 49 of 59 11N40SISO-Ant1-2422-30~1000-PASS 11N40SISO-Ant1-2422-1000~26500-PASS Page 50 of 59 11N40SISO-Ant1-2437-0~Reference-PASS 11N40SISO-Ant1-2437-30~1000-PASS Page 51 of 59 11N40SISO-Ant1-2437-1000~26500-PASS 11N40SISO-Ant1-…