Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF Exposure Considerations This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Dongguan Fenggang Long’an Electrical Appliance Factory Address: Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Phone: +86-13480900044 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-04-03 Name / Title: MingJiang Duan / PM Company: Dongguan Fenggang Long’an Electrical Appliance Factory Address: Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Phone: +86-13480900044 Fax: N/A E-Mail: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BFGX-HIP-C201L HIP-C201L, HIP-C201W, HIP-C201, HIP-201X We, applicant Company Name: Dongguan Fenggang Long’an Electrical Appliance Factory Address: Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Phone: +86-13480900044 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-04-03 Name / Title: MingJiang Duan / PM Company: Dongguan Fenggang Long’an Electrical Appliance Factory Address: Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Phone: +86-13480900044 Fax: N/A E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BFGX-HIP-C201L HIP-C201L, HIP-C201W, HIP-C201, HIP-201X For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-04-03 Name / Title: MingJiang Duan / PM Company: Dongguan Fenggang Long’an Electrical Appliance Factory Address: Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Phone: +86-13480900044 Fax: N/A E-Mail: [email protected]
Dongguan Fenggang Long’an Electrical Appliance Factory Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Date: April 3, 2024 FCC ID: 2BFGX-HIP-C201L Model Number: HIP-C201L, HIP-C201W, HIP-C201, HIP-201X To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Dongguan Fenggang Long’an Electrical Appliance Factory hereby declare that our product (fully automatic cat toilet) Model Number: HIP-C201L, HIP-C201W, HIP-C201, HIP-201X board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name/Title: MingJiang Duan / PM Company: Dongguan Fenggang Long’an Electrical Appliance Factory Address: Room 202, Building 1, No.51, Fenggang Section, Dongshen Road, Fenggang Town, DongGuan, Guangdong 523697, China Tel: +86-13480900044 Fax: N/A E-Mail: [email protected]
Page1of5FCCID:2BFGX-HIP-C201L ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:2BFGX-HIP-C201L ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2BFGX-HIP-C201L ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2BFGX-HIP-C201L ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2BFGX-HIP-C201L ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9
Page1of1FCCID:2BFGX-HIP-C201L ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L40mmxW20mm) LabelLocation fullyautomaticcattoilet Model:HIP-C201L FCCID:2BFGX-HIP-C201L
Page 1 of 4 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 WIFI Antenna Page 2 of 4 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 BT Antenna Page 4 of 4 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page 1 of 8 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information EUT : fully automatic cat toilet Test Model : HIP-C201L Additional Model No. : HIP-C201W, HIP-C201, HIP-201X Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : For AC Adapter Input: 100-240V~, 50/60Hz, 0.6A Adapter Output: 12.0V2000mA Hardware Version : A02 Software Version : B02 Bluetooth Frequency Range : 2402MHz~2480MHz Channel Number : 40 channels for Bluetooth V4.2 (DTS) Channel Spacing : 2MHz for Bluetooth V4.2 (DTS) Modulation Type : GFSK for Bluetooth V4.2 (DTS) Bluetooth Version : V4.2 Antenna Description : PCB Antenna, 2.71dBi (Max.) WIFI (2.4G Band) Frequency Range : 2412MHz~2462MHz Channel Number : 11 Channels for 20MHz bandwidth(2412~2462MHz) 7 Channels for 40MHz bandwidth(2422~2452MHz) Channel Spacing : 5MHz Modulation Type : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description : FPC Antenna, 3.25dBi (Max.) WIFI (5G Band) Frequency Range : 5180-5240MHz, 5260-5320MHz, 5500-5700MHz Channel Number : 4 Channels for 20MHz bandwidth(5180MHz-5240MHz) 4 Channels for 20MHz bandwidth(5260MHz-5320MHz) 11 Channels for 20MHz bandwidth(5500MHz-5700MHz) 2 channels for 40MHz bandwidth(5190MHz~5230MHz) 2 channels for 40MHz bandwidth(5270MHz~5310MHz) 5 Channels for 40MHz bandwidth(5510MHz-5670MHz) Modulation Type : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description : FPC Antenna, 5.2GWIFI:5.05dBi (Max.) WIFI (5.8G Band) Frequency Range : 5745MHz~5825MHz Channel Number : 5 channels for 20MHz bandwidth(5745MHz~5825MHz) 2 channels for 40MHz bandwidth(5755MHz~5795MHz) Modulation Type : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description : FPC Antenna, 5.05dBi (Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Device Page 2 of 8 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density Page 3 of 8 FCC ID: 2BFGX-HIP-C201L Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. MPE Calculation Method Predication of MPE limit at a given distance Equ…
Text truncated - open the document above for the full version.
R&D,productionandsalesofprofessionalwirelessterminalantenna 承认书 SPECIFICATIONFORAPPROVAL 客户名称CustomerName:和仕佳 产品型号ProductModel:CSC_PF01-2 客户料号CustomerP/N: 鑫恒阳料号XINHENGYANGP/N:CP.041.A00440009 产品规格SPECIFFCATIONS:频段:2400MHZ-2500MHZ 5150MHZ-5850MHZ 制作日期Productiondate:2024-04-08 封样版本SampleVersion:V1.0 Phone : 0 7 55 - 83 6 00 9 1 6 E-mail :[email protected] :https://www.XHY-2008.com 鑫恒阳(XINHENGYANG) 编制(FICTION)结构(Structure)研发(R&D) 客户(Customer) 采购(PUR)品质(QC)研发(R&D) Manufacturer: Shenzhen Xinghengyang Technology Co., Ltd. Address: Room 909 Kanghesheng Building, No.1 Chuangsheng Road, Shuguang Community, Xili Street, Nanshan District, Shenzhen, China Website R&D,productionandsalesofprofessionalwirelessterminalantenna NumberEffectivedateChangerecord V1.02024-04-08 Initialrelease R&D,productionandsalesofprofessionalwirelessterminalantenna 一、Basicparameters A.ElectricalCharacteristics Frequency2400MHZ-2500MHZ 5150MHZ-5850MHZ VSWR<2.5 AvgEfficiency2.4G>60%5G>40% Impedance50±25Ohm PolarizationLinear PeakGain2.4G : 3.25dBi 5G : 5.05dBi B.Material&MechanicalCharacteristics MaterialofRadiatorFPCWhite CableType Φ 1.13mmL=95mm ± 3mmBlack ConnectorType一代端子 Dimension48.30mm±0.2mm*15.85mm±0.2mm C.Environmental OperationTemperature-20 ̊C~+60 ̊C StorageTemperature-30 ̊C~+70 ̊C R&D,productionandsalesofprofessionalwirelessterminalantenna 二、Electricalspecifications ThosespecificationswerespeciallydefinedforCSC_PF01-2model. 三、VSWR 1Measurementmethod 1.A50Ωcoaxialcableisconnectedtotheantenna.Thenthiscableisconnected toanetworkanalyzertomeasuretheVSWR 2.Keepingthisjigawayfrommetalatleast20cm 2Measurefrequencypointsandstandingwaveratio R&D,productionandsalesofprofessionalwirelessterminalantenna 四、IntroductiontoDarkroom Introduction: Microwavedarkroomandnoreflectionchamber,absorbingshortwavedarkroom darkroom.Microwavedarkroombyelectromagneticshieldingroom,filtering andisolation,groundingdevice,theventilationduct,indoordistributionsystem, monitoringsystem,ceilingwavematerialpart.Itisbasedonthewaveabsorbing materialastheliningoftheshieldroom,itcanabsorbthemostofthe electromagneticenergyintothesixwallisabettersimulationofthefreespace conditions. Themainworkingprincipleofmicrowaveanechoicchamberisaccordingtothe electromagneticwaveinthemediumfromthelowmagneticguidemagnetic directionofpropagationrules,absorbingmaterialstoguidetheelectromagnetic waveusinghighpermeability,throughresonance,asubstantialabsorptionof electromagneticwaveradiationenergy,bycouplingtheelectromagneticenergy intoheatenergy. mainperformance: Frequencyrange:400MHz~6GHzceilingreflectedwavelossmaterials:400MHz~ 6GHzisequaltoormorethan15dB(microwaveabsorbingmaterialbycompositewave absorbingmaterials,namelytaperedcontainingcarbonspongesuctionwavematerial pasteinferrite) R&D,productionandsalesofprofessionalwirelessterminalantenna 五、Antennaperformance Passivefieldpatterndiagram-2400MHZ-2500MHZ Passiveefficiency&gain R&D,productionandsalesofprofessionalwirelessterminalantenna Passivefieldpatterndiagram-5150MHZ-5850MHZ Passiveefficiency&gain R&D,productionandsalesofprofessionalwirelessterminalantenna Activedata R&D,productionandsalesofprofessionalwirelessterminalantenna 、Antennadrawingdimensions R&D,productionandsalesofprofessionalwirelessterminalantenna 七、ROHS Antenna CP.041.A00440009 meetsRoHSrequirements. 八、Productpackaginginstructions A.packingshouldmeetthemoistureproof,vibration,pressureand mildewproof,etc. B.thesmallestpackingunitlogomusthavethemanufacturer trademarks,productmodel,name,codeandquantity. C.intheattachedpackinglist,certificateofapproval,andthefactory inspectionreport. ***************************END****************************
Page 1 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C RF Test Data for 5.2GWIFI(Conducted Measurement) Product Name: fully automatic cat toilet Test Model: HIP-C201L Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Paddi Chen Supervised by: Nick Peng Page 2 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity C.1 -26dB Bandwidth Condition Mode Frequency (MHz) Antenna -26 dB Bandwidth (MHz) Limit -26 dB Bandwidth (MHz) Verdict NVNT a 5180 Ant1 22.901 --- Pass NVNT a 5200 Ant1 23.782 --- Pass NVNT a 5240 Ant1 21.123 --- Pass NVNT n20 5180 Ant1 24.722 --- Pass NVNT n20 5200 Ant1 24.902 --- Pass NVNT n20 5240 Ant1 25.038 --- Pass NVNT n40 5190 Ant1 39.492 --- Pass NVNT n40 5230 Ant1 41.705 --- Pass Page 3 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -26dB Bandwidth NVNT a 5180MHz Ant1 -26dB Bandwidth NVNT a 5200MHz Ant1 Page 4 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -26dB Bandwidth NVNT a 5240MHz Ant1 -26dB Bandwidth NVNT n20 5180MHz Ant1 Page 5 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -26dB Bandwidth NVNT n20 5200MHz Ant1 -26dB Bandwidth NVNT n20 5240MHz Ant1 Page 6 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -26dB Bandwidth NVNT n40 5190MHz Ant1 -26dB Bandwidth NVNT n40 5230MHz Ant1 Page 7 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity C.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT a 5180 Ant1 12.82 0.37 13.19 24 Pass NVNT a 5200 Ant1 12.44 0.38 12.82 24 Pass NVNT a 5240 Ant1 11.67 0.37 12.04 24 Pass NVNT n20 5180 Ant1 10.99 0.43 11.42 24 Pass NVNT n20 5200 Ant1 10.73 0.43 11.16 24 Pass NVNT n20 5240 Ant1 10 0.43 10.43 24 Pass NVNT n40 5190 Ant1 9.6 0.79 10.39 24 Pass NVNT n40 5230 Ant1 9.72 0.79 10.51 24 Pass Page 8 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity C.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/MHz) Duty Factor (dB) Total PSD (dBm/MHz) Limit (dBm/MHz) Verdict NVNT a 5180 Ant1 2.15 0.37 2.52 11 Pass NVNT a 5200 Ant1 1.93 0.38 2.31 11 Pass NVNT a 5240 Ant1 1.39 0.37 1.76 11 Pass NVNT n20 5180 Ant1 0.3 0.43 0.73 11 Pass NVNT n20 5200 Ant1 0 0.43 0.43 11 Pass NVNT n20 5240 Ant1 -1.32 0.43 -0.89 11 Pass NVNT n40 5190 Ant1 -4.02 0.79 -3.23 11 Pass NVNT n40 5230 Ant1 -4.04 0.79 -3.25 11 Pass Page 9 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT a 5180MHz Ant1 PSD NVNT a 5200MHz Ant1 Page 10 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT a 5240MHz Ant1 PSD NVNT n20 5180MHz Ant1 Page 11 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT n20 5200MHz Ant1 PSD NVNT…
Text truncated - open the document above for the full version.
Page 1 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix D RF Test Data for 5.3GWIFI(Conducted Measurement) Product Name: fully automatic cat toilet Test Model: HIP-C201L Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Paddi Chen Supervised by: Nick Peng Page 2 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity D.1 -26dB Bandwidth Condition Mode Frequency (MHz) Antenna -26 dB Bandwidth (MHz) Limit -26 dB Bandwidth (MHz) Verdict NVNT a 5260 Ant1 28.432 --- Pass NVNT a 5300 Ant1 26.315 --- Pass NVNT a 5320 Ant1 26.493 --- Pass NVNT n20 5260 Ant1 28.501 --- Pass NVNT n20 5300 Ant1 27.075 --- Pass NVNT n20 5320 Ant1 28.796 --- Pass NVNT n40 5270 Ant1 41.901 --- Pass NVNT n40 5310 Ant1 42.606 --- Pass Page 3 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -26dB Bandwidth NVNT a 5260MHz Ant1 -26dB Bandwidth NVNT a 5300MHz Ant1 Page 4 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -26dB Bandwidth NVNT a 5320MHz Ant1 -26dB Bandwidth NVNT n20 5260MHz Ant1 Page 5 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -26dB Bandwidth NVNT n20 5300MHz Ant1 -26dB Bandwidth NVNT n20 5320MHz Ant1 Page 6 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -26dB Bandwidth NVNT n40 5270MHz Ant1 -26dB Bandwidth NVNT n40 5310MHz Ant1 Page 7 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity D.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT a 5260 Ant1 12.7 0.38 13.08 24 Pass NVNT a 5300 Ant1 12.79 0.38 13.17 24 Pass NVNT a 5320 Ant1 12.34 0.38 12.72 24 Pass NVNT n20 5260 Ant1 11.93 0.43 12.36 24 Pass NVNT n20 5300 Ant1 11.91 0.43 12.34 24 Pass NVNT n20 5320 Ant1 11.29 0.43 11.72 24 Pass NVNT n40 5270 Ant1 10.86 0.78 11.64 24 Pass NVNT n40 5310 Ant1 10.78 0.79 11.57 24 Pass Page 8 of 29 FCC ID: 2BFGX-HIP-C201L Report No.: LCSA02284080ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity D.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/MHz) Duty Factor (dB) Total PSD (dBm/MHz) Limit (dBm/MHz) Verdict NVNT…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.75 GHz - 5.83 GHz | 18.10 mW |