FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Yidayan Technology Co., Ltd/
  3. 2BFRC-ARLHAT01

2BFRC-ARLHAT01ANRUOLA Cooling Gel Hat

Shenzhen Yidayan Technology Co., Ltd
ANRUOLA Cooling Gel Hat - FCC ID 2BFRC-ARLHAT01 - Shenzhen Yidayan Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 12, 2024
Application Purpose
Original Equipment
Date of Application
Jun 12, 2024
Equipment Note
ANRUOLA Cooling Gel Hat
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Yidayan Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

OasisCompliance,Inc.FCCID: 2BFRC-ARLHAT01 CFR47§2.911(d)(7)FCCUSAgentLetterofAttestation Date:04-23-2024 FCCID:2BFRC-ARLHAT01FRN:0035252808 To:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ToWhomItMayConcern, ThisletteristoconfirmthatwehaveacceptedtheresponsibilitytoactasUSAgentonbehalf ofShenzhenYidayanTechnologyCo.,Ltd(“theapplicant”)fortheabovereferencedFCCID. Weareawareoftherequirementsandresponsibilitiesoftheapplicant’sagentforserviceof processasoutlinedintheFCCsection2.911(d)(7)andReportandOrderFCC22-84paragraph 63. U.S.AgentInformation: OasisCompliance,Inc. FRN:0033464157 JamesHe 3313VerdiDr,SanJose,CA95111 Cell:2026028330 Sincerelyyours, JamesHe GlobalMarketAccessManager OasisCompliance,Inc. Email:[email protected]

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Yidayan Technology Co., Ltd FRN: 0035252808 Grantee code: 2BFRC FCC ID: 2BFRC-ARLHAT01 Contact Name: JiYan Su Address: Room 21102110H31, Jinzhonghuan International Business Building, No. 3037 Jintian Road, Fu'an Community, Futian Street, Futian District, Shenzhen City Telephone No: +8613356464712 Fax No: Email: [email protected] i. [Shenzhen Yidayan Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [ Shenzhen Yidayan Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Shenzhen Yidayan Technology Co., Ltd certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Date: 06.05.2024 Applicant’s Name: JiYan Su Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

CFR47§2.911(d)(7)AgentDesignationAttestation Date:04-24-2024 FCCID:2BFRC-ARLHAT01FRN:0035252808 To:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ShenzhenYidayanTechnologyCo.,Ltd(“theapplicant”)asrequiredbysection2.911(d)(7), designatesthefollowingagent,locatedintheUnitedStates,forpurposesofactingasthe applicant’sagentforserviceofprocess. Theapplicantacknowledgesthattheywillmaintainanagentfornolessthanoneyearafterthe granteehasterminatedallmarketingandimportationortheconclusionofanyCommission- relatedproceedinginvolvingtheequipment.Theapplicantfurtheracknowledgestheir responsibilitytoinformtheFCCwhenevertheagentinformationchanges. U.S.AgentInformation: JamesHe OasisCompliance,Inc. 3313VerdiDr,SanJose,CA95111 [email protected] cell:2026028330 Sincerelyyours, _________________________________ SuJiYan Manager ShenzhenYidayanTechnologyCo.,Ltd Address:Room21102110H31,JinzhonghuanInternationalBusinessBuilding,No.3037,Jintian Road,Fu'anCommunity,FutianStreet,FutianDistrict,Shenzhen,China Email:[email protected] Phone:+8613356464712

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Shenzhen Yidayan Technology Co., Ltd Address: Room 21102110H31, Jinzhonghuan International Business Building, No. 3037 Jintian Road, Fu'an Community, Futian Street, Futian District, Shenzhen City Product Name: ANRUOLA Cooling Gel Hat Model Number: ARLHAT01 FCC Identifier: 2BFRC-ARLHAT01 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: JiYan Su Date: 6/5/2024 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Shenzhen Yidayan Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 6/5/2024 Subject: Request for Confidentiality FCC ID: 2BFRC-ARLHAT01 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: JiYan Su Title: Manager

External Photos

Page 1 of 6 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Photographs of the EUT (External Photos) Model: ARLHAT01 Page 2 of 6 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Page 3 of 6 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Page 4 of 6 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Page 5 of 6 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Page 6 of 6 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected]

ID Label/Location Info

Label Size:3cm*4cm Location Name: ANRUOLA Cooling Gel Hat Model: ARLHAT01 ANRUOLA IC: 32288-ARLHAT01 FCC ID:2BFRC-ARLHAT01 Input:3.7V 180mAh

Internal Photos

Page 1 of 3 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Photographs of the EUT (Internal Photos) Model: ARLHAT01 Page 2 of 3 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] ANT Page 3 of 3 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected]

RF Exposure Info

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi240325022-01E2 Date of issue: 2024-04 -17 Applicant: Shenzhen Yidayan Technology Co., Ltd Product: ANRUOLA Cooling Gel Hat Model(s): ARLHAT01 FCC ID: 2BFRC-ARLHAT01 Shenzhen Microtest Co., Ltd. http://www.mtitest.cn - Page 2 of 6- Report No.: MTi240325022-01E2 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 6- Report No.: MTi240325022-01E2 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] Test Result Certification Applicant: Shenzhen Yidayan Technology Co., Ltd Address: Room 21102110H31, Jinzhonghuan International Business Building, No. 3037 Jintian Road, Fu'an Community, Futian Street, Futian District, Shenzhen City Manufacturer: Shenzhen Yidayan Technology Co., Ltd Address: Room 21102110H31, Jinzhonghuan International Business Building, No. 3037 Jintian Road, Fu'an Community, Futian Street, Futian District, Shenzhen City Product description Product name: ANRUOLA Cooling Gel Hat Trademark: ANRUOLA Model name: ARLHAT01 Series Model: N/A Standards: N/A Test method: KDB 447498 D01 v06 Date of Test Date of test: 2024-04 -10 to 2024-04 -15 Test result: Pass Test Engineer : (Yanice.Xie) Reviewed By : (David Lee) Approved By : (Leon Chen) - Page 4 of 6- Report No.: MTi240325022-01E2 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] Table of Contents 1. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ............................................................................................ 5 2. SAR TEST EXCLUCSION THRESHOLDS ........................................................................................................................ 6 - Page 5 of 6- Report No.: MTi240325022-01E2 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] 1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions. a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f (GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz 2) {[Power allow…

Text truncated - open the document above for the full version.

Test Report

InvertedFAntennaSpecification Summary ITEM ANTSPEC ModelName 2.4GANT Center Frequency HorizontalVertical 2400MHzMHz2500MHz2400MHzHz2500MHz -1.26-0.76-0.58-5.25-2.46-1.86 MAX.Gain-0.58 Polarization HorizontalandVertical AzimuthBeam Pattern Omni-directional Impedance50Ohm AntennaLength 38.20mm Manufacture ShenzhenBluetrumTechnologyCo.,Ltd. AntennaPhoto&Length(mm) 2450 2450M dBi Horizontal:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-40Scale:5/div Frequency (MHz) Gain Max Min Avg 2400-1.26174-30.0801-7.18716 2450-0.765802-36.5604-7.48023 2500-0.585582-22.0315-6.59127 dBi Vertical:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-30Scale:5/div Frequency (MHz) Gain Max Min Avg 2400-5.2537-22.1424-12.4294 2450-2.4652-24.5837-10.4702 2500-1.86120-29.5214-9.20432 ANTTestLabsAttestationofGlobalComplianceCo.,Ltd. dBi

Test Report

The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] Test Report Report No.: MTi240325022-01E1 Date of issue: 2024-04-17 Applicant: Shenzhen Yidayan Technology Co., Ltd Product: ANRUOLA Cooling Gel Hat Model(s): ARLHAT01 FCC ID: 2BFRC-ARLHAT01 Shenzhen Microtest Co., Ltd. http://www.mtitest.cn Page 2 of 66 Report No.: MTi240325022-01E1 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 66 Report No.: MTi240325022-01E1 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.cn E-mail: [email protected] Table of contents 1 General Description ......................................................................................................................... 5 1.1 Description of the EUT ............................................................................................................................... 5 1.2 Description of test modes .......................................................................................................................... 5 1.3 Environmental Conditions .......................................................................................................................... 7 1.4 Description of support units ....................................................................................................................... 7 1.5 Measurement uncertainty .......................................................................................................................... 7 2 Summary of Test Result .................................................................................................................. 8 3 Test Facilities and accreditations ................................................................................................... 9 3.1 Test laboratory ........................................................................................................................................... 9 4 List of test equipment .................................................................................................................... 10 5 Evaluation Results (Evaluation) .................................................................................................... 11 5.1 Antenna requirement ............................................................................................................................... 11 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 12 6.1 Occupied Bandwidth ................................................................................................................................ 12 6.2 Maximum Conducted Output Power ........................................................................................................ 14 6.3 Channel Separation ................................................................................................................................. 16 6.4 Number of Hopping Frequencies ............................................................................................................. 17 6.5 Dwell Time ............................................................................................................................................... 19 6.6 RF conducted spurious emissions and band edge measurement .......................................................... 21 6.7 Band edge emissions (Radiated) ............................................................................................................ 23 6.8 Radiated emissions (below 1GHz) ......................................................................................................... 26 6.9 Radiated emissions (above 1GHz) .......................................................................................................... 30 Photographs of the test setup ............................................................................................................. 34 Photographs of the EUT....................................................................................................................... 35 Appendix A: 20dB Emission Bandwidth ............................................................................................. 37 Appendix B: Maximum conducted output power ............................................................................... 41 Appendix C: Carrier frequency separation ......................................................................................... 45 Appendix D: Time of occupancy ......................................................................................................... 47 Appendix E: Number of hopping channels......................................................................................... 54 Appendix F: Band edge measurements ...............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China. Tel : (8 6-755)88850135 Fax: (86-755) 88850136 We b : www.mtitest.cn E-mail: [email protected] Photographs of the test setup Model: ARLHAT01 Radiated emissions (below 1GHz) Radiated emissions (above 1GHz)

Contact Information

Applicant

JiYan Su(Manager)
[email protected]+8613356464712Fax: +8613356464712

Technical Contact

Shenzhen Microtest Co., LtdLeon Chen
[email protected]+86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.