Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.
Dongguan AiKeDe Electronic Technology Co.,Ltd. 7th Floor, Building 2, 122 Houyong Road, Houjie Town,Dongguan City, Guangdong Province China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-3-17 To whom it may concern: We, Dongguan AiKeDe Electronic Technology Co.,Ltd., hereby certify that the equipment for which authorization is sought (FCC ID: 2BFRJ-AKD-YD52) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Wenjun Huang Projects Dongguan AiKeDe Electronic Technology Co.,Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
Dongguan AiKeDe Electronic Technology Co.,Ltd. 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024/02/21 U.S. Agent Designation Dongguan AiKeDe Electronic Technology Co.,Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BFRJ-AKD-YD52): Name and company of U.S. agent: GSS SERVICE INC Physical U.S. address of agent: 6547 N Academy Blvd #2266 Colorado Springs COLORADO 80918 United States FRN of U.S. agent: 0033402082 Email address of U.S. agent: [email protected] GSS SERVICE INC acknowledges their obligation to accept service of process on behalf of Dongguan AiKeDe Electronic Technology Co.,Ltd. Dongguan AiKeDe Electronic Technology Co.,Ltd. with the FRN [0034949388] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Wenjun Huang Projects Dongguan AiKeDe Electronic Technology Co.,Ltd. Signature Michoux Logan PM GSS SERVICE INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-3-17> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BFRJ-AKD-YD52 AKD-YD52 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Wenjun Huang/Projects Company: Dongguan AiKeDe Electronic Technology Co.,Ltd. Address: 7th Floor, Building 2, 122 Houyong Road, Houjie Town,Dongguan City, Guangdong Province China Phone: 13332691174 Fax: N/A E-Mail: [email protected]
Dongguan AiKeDe Electronic Technology Co.,Ltd. 7th Floor, Building 2, 122 Houyong Road, Houjie Town,Dongguan City, Guangdong Province China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-3-17 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BFRJ-AKD-YD52 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Wenjun Huang/Projects Company: Dongguan AiKeDe Electronic Technology Co.,Ltd. Address: 7th Floor, Building 2, 122 Houyong Road, Houjie Town,Dongguan City, Guangdong Province China Phone: 13332691174 Fax: N/A E-Mail: [email protected]
FCC ID: 2BFRJ-AKD-YD52 External Photos of the EUT FCC ID: 2BFRJ-AKD-YD52
FCC ID: 2BFRJ-AKD-YD52 Internal Photos of the EUT FCC ID: 2BFRJ-AKD-YD52 Loop coil Antenna FCC ID: 2BFRJ-AKD-YD52
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT Report Reference No. .................... : FCC ID. ........................................... : CTA24012400101 2BFRJ-AKD-YD52 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Amy Wen Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jan. 29, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ........................................... : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ........................... : Dongguan AiKeDe Electronic Technology Co.,Ltd. Address ........................................... : 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Test specification ........................... : FCC CFR 47 PART 1, § 1.1310 Standard ........................................... : KDB 680106 D01 Wireless Power Transfer v04 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Wireless power bank Trade Mark ....................................... : N/A Manufacturer .................................... : Dongguan AiKeDe Electronic Technology Co.,Ltd. Model/Type reference ...................... : AKD-YD52 Listed Models .................................. : N/A Modulation Type ............................... : ASK Operation Frequency ....................... : From 110KHz~205KHz Rating ............................................... : DC 3.7V From Battery Input: 5V 3A, 9V 2.22A, 12V 1.67A Output: 5V 3A, 9V 2.22A, 12V 1.67A Wireless charging output: 7.5W for iOS, 15W for Android Result ............................................... : PASS Report No.: CTA24012400102 Page 2 of 18 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Wireless power bank Model /Type : AKD-YD52 Applicant : Dongguan AiKeDe Electronic Technology Co.,Ltd. Address : 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Manufacturer : Dongguan AiKeDe Electronic Technology Co.,Ltd. Address : 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24012400102 Page 3 of 18 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................... 4 2 S U M MA R Y .............................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Description of the test mode 5 2.4 Special Accessories 5 2.5 Modifications 5 3 T E S T E N V I R O N M E N T 6 3.1 Address of the test laboratory 6 3.2 Test Facility 6 3.3 Statement of the measurement uncertainty 6 3.4 Equipments Used during the Test 6 4 T E S T L I M I T 7 4.1 Requirement 7 4.2 Test setup 7 4.3 Test Procedures 9 4.4 Equipment Approval Considerations of KDB 680106 D01v04 9 4.5 Test results 10 4.6 Conclusion 12 5 P H O T O G R A P H S O F T H E TE S T S E T U P 13 Report No.: CTA24012400102 Page 4 of 18 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: 680106 D01 Wireless Power Transfer v04: EQUIPMENT AUTHORIZATION OF WIRELESS POWER TRANSFER DEVICES. Report No.: CTA24012400102 Page 5 of 18 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 2 S U M M A RY 2.1 General Remarks Date of receipt of test sample : Jan. 20, 2024 Testing commenced on : Jan. 20, 2024 Testing concluded on : Jan. 29, 2024 2.2 Product Description Product Name: Wireless power bank Model/Type reference: AKD-YD52 Hardware version: V1.0 Software version: V1.0 Test samples ID: CTA240124001-1# (Engineer sample) CTA240124001-2# (Normal sample) Power supply: DC 3.7V From Battery Input: 5V 3A, 9V 2.22A, 12V 1.67A Output: 5V 3A, 9V 2.22A, 12V 1.67A Wireless charging output: 7.5W for iOS, 15W for Android Adapter information (Auxiliary test supplied by test Lab) : Input: AC 100-240V 50/60Hz Output: DC 5V 3A, 9V 2.22A, 12V 1.67A Operation frequency: 110KHz - 205KHz Modulation type: ASK Ante…
Text truncated - open the document above for the full version.
1. Antenna Description: Antenna type Loop coil Antenna Model AKD-YD52 Frequency range 110KHz~205KHz Manufacturer Dongguan AiKeDe Electronic Technology Co.,Ltd. Gain 0.00 dBi 2. Antenna Photo:
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT Report Reference No. ..................... : FCC ID............................................. : CTA24012400101 2BFRJ-AKD-YD52 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Amy Wen Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jan. 29, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Dongguan AiKeDe Electronic Technology Co.,Ltd. Address............................................ : 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Test specification ........................... : Standard ........................................... : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Wireless power bank Trade Mark ....................................... : N/A Manufacturer .................................... : Dongguan AiKeDe Electronic Technology Co.,Ltd. Model/Type reference ...................... : AKD-YD52 Listed Models .................................. : N/A Modulation Type ............................... : ASK Operation Frequency ........................ : From 110KHz~205KHz Rating ............................................... : DC 3.7V From Battery Input: 5V 3A, 9V 2.22A, 12V 1.67A Output: 5V 3A, 9V 2.22A, 12V 1.67A Wireless charging output: 7.5W for iOS, 15W for Android Result ............................................... : PASS Report No.: CTA24012400101 Page 2 of 23 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Wireless power bank Model /Type : AKD-YD52 Listed Models : N/A Applicant : Dongguan AiKeDe Electronic Technology Co.,Ltd. Address : 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Manufacturer : Dongguan AiKeDe Electronic Technology Co.,Ltd. Address : 7th Floor, Building 2, 122 Houyong Road, Houjie Town, Dongguan City, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24012400101 Page 3 of 23 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Description of the test mode 5 2.4 Special Accessories 5 2.5 Modifications 5 3 T E S T E N V I R O N M E N T .............................................................. 6 3.1 Address of the test laboratory 6 3.2 Test Facility 6 3.3 Environmental conditions 6 3.4 Summary of measurement results 7 3.5 Statement of the measurement uncertainty 7 3.6 Equipments Used during the Test 7 4 T E S T C O N D I T I O N S A N D R E S U L T S ............................................. 9 4.1 AC Power Conducted Emission 9 4.2 Radiated Emission 12 4.3 The 20dB bandwidth 16 4.4 Antenna Requirement 17 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 18 6 PH O T O S O F T H E E U T ........................................................... 19 Report No.: CTA24012400101 Page 4 of 23 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15 Subpart C (Section 15.207): Conducted limits. FCC Rules and Regulations Part 15 Subpart C (Section 15.209): Radiated emission limits; general requirements. ANSI C63.10: 2013: American National Standard for Testing Unlicensed Wireless Devices Report No.: CTA24012400101 Page 5 of 23 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Jan. 20, 2024 Testing commenced on : Jan. 20, 2024 Testing concluded on : Jan. 29, 2024 2.2 Product Description Product N…
Text truncated - open the document above for the full version.
FCC ID: 2BFRJ-AKD-YD52 Test Setup Photos of the EUT
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |