FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shaoxing ShangYu FeiXiang Photographic Equipment Plant/
  3. 2BFTR-M800

2BFTR-M800Photographic lamp

Shaoxing ShangYu FeiXiang Photographic Equipment Plant
Photographic lamp - FCC ID 2BFTR-M800 - Shaoxing ShangYu FeiXiang Photographic Equipment Plant
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 21, 2024
Application Purpose
Original Equipment
Date of Application
Jul 21, 2024
Equipment Note
Photographic lamp
Frequency Range
433.92000000 - 433.92000000
Company
Shaoxing ShangYu FeiXiang Photographic Equipment Plant
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterference received,includinginterferencethatmaycauseundesiredoperation. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainst harmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception, whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe user'sauthoritytooperatetheequipment. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeusedin portableexposureconditionwithoutrestriction.

Attestation Statements

ShaoxingShangYuFeiXiangPhotographicEquipmentPlant 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:ShaoxingShangYuFeiXiangPhotographicEquipmentPlant Address:YueBeiVillage,XiaoYueTown,Shangyu,Zhejiang,China ProductName:Photographiclamp FCCID:2BFTR-M800 Model(s):M800-BI,M800,M800-QD,M800-SP,M800-BJ,M800-FX,M320W-BI,M320W, M320W-QD,M320W-SP,M320W-BJ,M320W-FX. 2.911(d)(5)(i)EquipmentType We,[ShaoxingShangYuFeiXiangPhotographicEquipmentPlant](“theapplicant”)certifythatthe equipmentforwhichauthorizationissoughtthroughcertificationisnot:  Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules.  Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:XiangquanLuoDate:2024-07-01 TitleandCompanyname:Engineer,ShaoxingShangYuFeiXiangPhotographicEquipmentPlant NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

ShaoxingShangYuFeiXiangPhotographicEquipmentPlant 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:ShaoxingShangYuFeiXiangPhotographicEquipmentPlant Address:YueBeiVillage,XiaoYueTown,Shangyu,Zhejiang,China ProductName:Photographiclamp FCCID:2BFTR-M800 Model(s):M800-BI,M800,M800-QD,M800-SP,M800-BJ,M800-FX,M320W-BI,M320W, M320W-QD,M320W-SP,M320W-BJ,M320W-FX. 2.911(d)(5)(ii)Applicantfiling We,[ShaoxingShangYuFeiXiangPhotographicEquipmentPlant](“theapplicant”)certifythat,as ofthedateofthefilingoftheapplication,theapplicantisidentified/isnotidentified NOTE1 onthe “CoveredList” NOTE2 ,establishedpursuantto§1.50002ofthischapter,asanentityproducing coveredcommunicationsequipment. Yourssincerely, Name:XiangquanLuoDate:2024-07-01 TitleandCompanyname:Engineer,ShaoxingShangYuFeiXiangPhotographicEquipmentPlant NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Cover Letter(s)

ShaoxingShangYuFeiXiangPhotographicEquipmentPlant AgentAuthorization Company:ShaoxingShangYuFeiXiangPhotographicEquipmentPlant Address:YueBeiVillage,XiaoYueTown,Shangyu,Zhejiang,China ProductName:Photographiclamp FCCID:2BFTR-M800 Model(s):M800-BI,M800,M800-QD,M800-SP,M800-BJ,M800-FX,M320W-BI,M320W, M320W-QD,M320W-SP,M320W-BJ,M320W-FX. ProductDescription:SDR433.92MHz WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2024-07-01 Name:XiangquanLuo Title:Engineer Company:ShaoxingShangYuFeiXiangPhotographicEquipmentPlant

Cover Letter(s)

ShaoxingShangYuFeiXiangPhotographicEquipmentPlant OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024-07-01 Subject;RequestforConfidentiality FCCID:2BFTR-M800 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:XiangquanLuoTitle:Engineer

Cover Letter(s)

ShaoxingShangYuFeiXiangPhotographicEquipment Plant Date:2024-07-01 Subject:authorizationforaddingfamilymodels FCCID:2BFTR-M800 TowhomitMayconcern, WewouldliketoconfirmthePhotographiclampWithModels(M800-BI,M800,M800-QD, M800-SP,M800-BJ,M800-FX,M320W-BI,M320W,M320W-QD,M320W-SP,M320W-BJ, M320W-FX.aresameinallrespects.Onlythemodelnamesaredifferentfordifferentmarket requirement. Yourssincerely, Signature: PrintedName:XiangquanLuo Company:ShaoxingShangYuFeiXiangPhotographicEquipmentPlant JobTitle:Engineer Email:[email protected] Telephone:86-13588563951

External Photos

EUTPHOTO(ExternalPhotos) ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

FCCID:2BFTR-M800

Internal Photos

EUTPHOTO(InternalPhotos) ※※※※※ENDOFREPORT※※※※※ Ant

RF Exposure Info

FCCID:2BFTR-M800 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093 UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≀50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f (GHz) ]≀3.0for1-gSAR,and≀7.5for10-gextremitySAR,where f (GHz) istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Here, MaxPower(dBm)MaxPower(mW)Frequency(MHz)Min.distance(mm)Calc.Resultlimit -26.020.015433.925 0.001 3.0 EIRP(dBm)=E(dBuV/m)-95.2=69.18-95.2=-126.02dBm SoaSARtestisnotrequired

Test Report

ProjectNo.:ZKT-240118L0940 Page 1 of 29 FCCTESTREPORT FCCID:2BFTR-M800 ReportNumber...................................:ZKT-240118L0940 DateofTest ....................................................... : Jun.24,2024toJul.02,2024 Dateofissue ......................................... : Jul.02,2024 Totalnumberofpages..........................29 TestResult .......................................... : PASS TestingLaboratory. ........................... : ShenzhenZKTTechnologyCo.,Ltd. Address ............................................... : 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname ............................. : ShaoxingShangYuFeiXiangPhotographicEquipmentPlant Address ............................................... : YueBeiVillage,XiaoYueTown,Shangyu,Zhejiang,China Manufacturer'sname......................: ShaoxingShangYuFeiXiangPhotographicEquipmentPlant Address...............................................: YueBeiVillage,XiaoYueTown,Shangyu,Zhejiang,China Testspecification: Standard ................................................ :FCCPart15(15.231),SubpartC Testprocedure ..................................... : / Non-standardtestmethod................:N/A TestReportFormNo........................: TRF-EL-107_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF ........................................ : Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................: Photographiclamp Trademark ........................................... : N/A Model/Typereference.........................: M800-BI,M800,M800-QD,M800-SP,M800-BJ,M800-FX, M320W-BI,M320W,M320W-QD,M320W-SP,M320W-BJ, M320W-FX. Ratings..................................................: DC3VFormBattery ProjectNo.:ZKT-240118L0940 Page 2 of 29 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China AlenHeTestedby(name+signature).......................: JoeLiuReviewer(name+signature).......................: LakeXie Approved(name+signature) ....................... : ProjectNo.:ZKT-240118L0940 Page 3 of 29 TableofContentsPage 1.VERSION...................................................................................................................5 2.SUMMARYOFTESTRESULTS...............................................................................6 2.1TESTFACILITY.................................................................................................................7 2.2MEASUREMENTUNCERTAINTY....................................................................................7 3.GENERALINFORMATION........................................................................................8 3.1GENERALDESCRIPTION................................................................................................8 3.2DESCRIPTIONOFTESTMODES....................................................................................9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED..............9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)........................................9 3.5EQUIPMENTSLISTFORALLTESTITEMS.................................................................10 4.EMCEMISSIONTEST.............................................................................................12 4.1CONDUCTEDEMISSIONMEASUREMENT..................................................................12 4.1.1POWERLINECONDUCTEDEMISSIONLIMITS..................................................12 4.1.2TESTPROCEDURE...............................................................................................13 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................13 4.1.4TESTSETUP...........................................................................................................13 4.1.5EUTOPERATINGCONDITIONS...........................................................................13 4.1.6TESTRESULTS......................................................................................................13 4.2RADIATEDEMISSIONMEASUREMENT......................................................................14 4.2.1RADIATEDEMISSIONLIMITS...............................................................................14 4.2.2TESTPROCEDURE...............................................................................................15 4.2.3TESTSETUP...........................................................................................................16 4.2.4EUTOPERATINGCONDITIONS...........................................................................17 4.2.5TESTRESULTS......................................................................................................17 5.1APPLIEDPROCEDURES/LIMIT.............................................................................22 5.2TESTPROCEDURE..................................................................................................22 5.3DEVIATIONFROMSTANDARD...............................................................................22 5.4TESTSETUP..............................................................................................................22 5.5EUTOPERATIONCONDITIONS..............................................................................22 5.6TESTRESULTS.........................................................................................................23 6.CALCULATIONOF


Text truncated - open the document above for the full version.

Test Setup Photos

EUTTESTPHOTO

Contact Information

Applicant

Xiangquan Luo
[email protected]13588563951Fax: 13588563951

Technical Contact

Shaoxing ShangYu FeiXiang Photographic Equipment P
[email protected]

China

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term