FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Yeasound (Xiamen) Hearing Technology Co., Ltd/
  3. 2BFVL-RIC700

2BFVL-RIC700Hearing Aids

Yeasound (Xiamen) Hearing Technology Co., Ltd

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 01, 2024
Application Purpose
Original Equipment
Date of Application
Aug 31, 2024
Equipment Note
Hearing Aids
Frequency Range
2402.00000000 - 2480.00000000
Company
Yeasound (Xiamen) Hearing Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Yeasound (Xiamen) Hearing Technology Co., Ltd No.668 Hu'an Road, Huli District, Xiamen China Tel: 0592-5702000-3099 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2BFVL-RIC700 Yeasound (Xiamen) Hearing Technology Co., Ltd certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature: Alina Zeng QMS & Compliance Manager

Attestation Statements

Yeasound (Xiamen) Hearing Technology Co., Ltd No.668 Hu'an Road, Huli District, Xiamen China Tel: 0592-5702000-3099 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2BFVL-RIC700 Yeasound (Xiamen) Hearing Technology Co., Ltd certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Alina Zeng QMS & Compliance Manager

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2BFVL-RIC700 Yeasound (Xiamen) Hearing Technology Co., Ltd certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Yeasound (Xiamen) Hearing Technology Co., Ltd accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Yeasound (Xiamen) Hearing Technology Co., Ltd Address: No.668 Hu'an Road, Huli District, Xiamen China FRN: 0035247196 Tel: 0592-5702000-3099 Email: [email protected] Signed by (printed name):Alina Zeng Signature:

Cover Letter(s)

Yeasound (Xiamen) Hearing Technology Co., Ltd No.668 Hu'an Road, Huli District, Xiamen China Tel: 0592-5702000-3099 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Yeasound (Xiamen) Hearing Technology Co., Ltd, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Alina Zeng QMS & Compliance Manager

Cover Letter(s)

Yeasound (Xiamen) Hearing Technology Co., Ltd No.668 Hu'an Road, Huli District, Xiamen China Tel: 0592-5702000-3099 Email: [email protected] FCC Confidential Authorization Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2BFVL-RIC700 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Yeasound (Xiamen) Hearing Technology Co., Ltd hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description As well as short-term confidential treatment of information accompanying this application for a period of 180 days after grant is issued as outlined below:  Internal Photos  User’s Manual  External Photos  Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Alina Zeng QMS & Compliance Manager

Cover Letter(s)

Yeasound (Xiamen) Hearing Technology Co., Ltd No.668 Hu'an Road, Huli District, Xiamen China Tel: 0592-5702000-3099 Email: [email protected] Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, Our product Hearing Aids, Model: RIC700, RIC700 MP, RIC700 HP, RIC700 LP; FCC ID: 2BFVL-RIC700, for marketing purpose, this product only supports BLE 1M/2M. The other functions were disabled to use by manufacture in the software, the end user has no capability to activate it. Sincerely Yours, Signature: Alina Zeng QMS & Compliance Manager

Cover Letter(s)

Yeasound (Xiamen) Hearing Technology Co., Ltd No.668 Hu'an Road, Huli District, Xiamen China Tel: 0592-5702000-3099 Email: [email protected] Product Similarity Declaration Date: 2024-08-27 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, Yeasound (Xiamen) Hearing Technology Co., Ltd, hereby declare that we have a product named as Hearing Aids, model: RIC700, FCC ID: 2BFVL-RIC700, was tested by Bay Area Compliance Laboratories Corp. (Shenzhen). Meanwhile, for our marketing purpose, we would like to list a series model: RIC700 MP, RIC700 HP, RIC700 LP on reports and certificate, all the models are identical in electrically, they only have different model name and Software version number (It does not affect the RF parameters). No other changes are made on them. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Sincerely, Signature: Alina Zeng QMS & Compliance Manager

ID Label/Location Info

Label: Label location: FCC ID: 2BFVL-RIC700 Stick the label on package and page 60 of user manual.

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401W49073E-RF-00 TR-EM-RF003 Page 11 of 56 Version 3.0 FCC§15.247 (i), §1.1307 (b) (1) &§2.1093 - RF EXPOSURE Applicable Standard According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where 1. f(GHz) is the RF channel transmit frequency in GHz. 2. Power and distance are rounded to the nearest mW and mm before calculation. 3. The result is rounded to one decimal place for comparison. 4. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test Exclusion. Measurement Result For worst case: Mode Frequency (MHz) Max tune-up conducted power # (dBm) Max tune-up conducted power # (mW) Distance (mm) Calculated value Threshold (1-g SAR) SAR Test Exclusion BLE 2402-2480 1.00 1.26 5 0.40 3 Yes Result: Compliant

Test Report

Antenna Specification SpecificationsSummary Antenna Photo & Length 天线类型 / FPC 天线型号 / dl RIC700ANT MAX. GAIN -5.58 dBi 制造商 / Mf Yeasound (Xiamen) Hearing Technology Co., LtdN 668 H ' R d H li Di i Xi Chi ITEM SPEC. 2.4GHz Center Frequency 2402 MHz -6.14 dBi2442 MHz -5.86 dBi2484 MHz -5.58 dBi ANT T yp e: FPC ANT Model: RIC700ANT 天线图 /ANT Photo Manufactory: N o.668 Hu'an Road, Huli District, Xiamen Chin a 2402MHz 3D Antenna Pattern 2442MHz 3D Antenna Pattern 2484MHz 3D Antenna Pattern Point Values Minimum Gain (dBi) Maximum Gain (dBi) Average Gain (d Bi) Frequency (MHz) 2402 -20.42 -6.14 -9.27 2442 -19.11 -5.86 -8.77 2484 -19.89 -5.58 -8.02

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF003 Page 1 of 56 Version 3.0 TEST REPORT Applicant Name: Yeasound (Xiamen) Hearing Technology Co., Ltd Address: No.668 Hu'an Road, Huli District, Xiamen China Report Number: 2401W49073E-RF-00 FCC ID: 2BFVL-RIC700 Test Standard (s) FCC PART 15.247 Sample Description Product Type: Hearing Aids Model No.: RIC700 Multiple Model(s) No.: RIC700 MP, RIC700 HP, RIC700 LP Trade Mark: Date Received: 2024/08/16 Issue Date: 2024/08/29 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Kungfumaster Liang Michelle Zeng RF Engineer RF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401W49073E-RF-00 TR-EM-RF003 Page 2 of 56 Version 3.0 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................... 9 TEST EQUIPMENT LIST ......................................................................................................................................... 10 FCC§15.247 (I), §1.1307 (B) (1) &§2.1093 - RF EXPOSURE ...................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 MEASUREMENT RESULT ............................................................................................................................................ 11 FCC §15.203 - ANTENNA REQUIREMENT ........................................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 12 FCC §15.209, §15.205 & §15.247(D) – UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS13 APPLICABLE STANDARD ............................................................................................................................................ 13 EUT SETUP ................................................................................................................................................................ 13 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP .............…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alina Zeng
[email protected]0592-5702000Fax: 0592-5702000

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Well Wang
[email protected]86-755-33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Yeasound (Xiamen) Hearing Technology Co., Ltd

2BFVL-CIC60L

Hearing aids (CIC)

Aug 11, 2026

Equipment Class

DTS - Digital Transmission System
2BFVL-CIC-01

Hearing aids (CIC)

Aug 11, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2BFVL-CIC60R

Hearing aids (CIC)

Aug 11, 2026

Equipment Class

DTS - Digital Transmission System