FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fosler trade company limited/
  3. 2BG4J-V261

2BG4J-V261BLUETOOTH FM Speaker

Fosler trade company limited
BLUETOOTH FM Speaker - FCC ID 2BG4J-V261 - Fosler trade company limited
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 01, 2024
Application Purpose
Original Equipment
Date of Application
Jul 01, 2024
Equipment Note
BLUETOOTH FM Speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
Fosler trade company limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

●PC/USBconnectioninsertUSBlineconnectedwiththecomputer,havetorestartthe shutdown,eventhecomputercan'thaveinUdishonboardwithrandom,theUSBlinePCprivide withthisplayer,PCwillbevisibletothemobilediskchoosewindow,selectthefoldereachother copyfiles ●Headset:insertheadsetwillenterthestereooutput.MODEisUdisk,card,EMfunctionkey switch. ●PlayedMusic:presslkey,theplay/stop;presslvol-key, ●chooseasong;press/VOL+key,selectthenextsong;longpresskeyvolumereduction;longpress lkeyvolumetoadd. ●FMmode:inFMstate,thelkeyonachannel,pressthelkeynextchannel,presslKeyforautomatic searchplatform. ●LINEinput:LongpresskeyswitchtoLINEmode,Andthentakeoutrandomwithstandarddata lineinsertedintotheholeontheUSB,Andthentakeacorrespondingmediaintothemachine,can listentoheadphonesholeyouwanttolistentothespngs. ISED Statement English:This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B). French: Cet appareil contient des Ă©metteurs/rĂ©cepteurs exempts de licence qui sont conformes aux RSS exemptĂ©s de licence d'Innovation, Sciences et DĂ©veloppement Ă©conomique Canada. L'exploitation est soumise aux deux conditions suivantes : (1) Cet appareil ne doit pas provoquer d'interfĂ©rences. (2) Cet appareil doit accepter toute interfĂ©rence, y compris les interfĂ©rences susceptibles de provoquer un fonctionnement indĂ©sirable de l'appareil. l'appareil numĂ©rique du ciem conforme canadien peut - 3 (b) / nmb - 3 (b). This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure and compliance. cet appareil est conforme Ă  l'exemption des limites d'Ă©valuation courante dans la section 2.5 du cnr - 102 et conformitĂ© avec rss 102 de l'exposition aux rf, les utilisateurs peuvent obtenir des donnĂ©es canadiennes sur l'exposition aux champs rf et la conformitĂ©. This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. Cet Ă©quipement est conforme aux limites d'exposition aux rayonnements du Canada Ă©tablies pour un environnement non contrĂŽlĂ©. The device has been evaluated to meet general RF exposure requirement. This equipment should be installed and operated with minimum distance 0mm between the radiator & your body. L'appareil a Ă©tĂ© Ă©valuĂ© pour rĂ©pondre aux exigences gĂ©nĂ©rales d'exposition aux RF. Cet Ă©quipement doit ĂȘtre installĂ© et utilisĂ© avec une distance minimale de 0 mm entre le radiateur et votre corps. FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

External Photos

Page2of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9

Internal Photos

Page2of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 BluetoothAntenna

RF Exposure Info

Page2of3FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ‱Theresultisroundedtoonedecimalplaceforcomparison ‱3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≀50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportablehost platformexposureconditions.ThegranteeisresponsiblefordocumentingthisaccordingtoClassI permissivechangerequirements.AntennasthatqualifyforstandaloneSARtestexclusionmust applytheestimatedstandaloneSARtodeterminesimultaneoustransmissiontestexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantennaconfiguration, adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≀1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≀0.04,andthe[∑ofMPEratios]is≀ 1.0. 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortableDevices RFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices 4.ConductedPowerResults <BT> ModeChannel Frequency(MHz)PeakConductedOutputPower(dBm) GFSK 024020.15 3924410 782480-0.63 π/4DQPSK 024020.55 3924410.15 7824800.09 5.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 π/4DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 Page3of3FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.EvaluationResults 6.1StandaloneEvaluation Band/Mode f (GHz) Antenna Distance (mm) RFoutputpower SARTest Exclusion Threshold SARTest Exclusion dBmmW BT GFSK2.40251.0 1.2589 0.3902<3.0Yes π/4DQPSK2.40251.0 1.2589 0.3902<3.0Yes Remark: 1.Outputpowerincludingtuneuptolerance; 2.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmaccordingtof)insection 4.1isappliedtodetermineSARtestexclusion. 6.2SimultaneousTransmissionforSARExclusion ThesamplesupportoneBTmodular.Noneedconsidersimultaneoustransmission. 7.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRF ExposureandSARExclusionThresholdperKDB447498v06. .......................THEENDOFREPORT.........................

Test Report

Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dBi) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dBi) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test LabsAttestation of Global Compliance Co., Ltd.

Test Report

Page 2 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dBBandwidth ConditionModeFrequency(MHz)Antenna-20 dB Bandwidth(MHz)Limit -20 dB Bandwidth(MHz)Verdict NVNT1-DH52402Ant10.951N/APass NVNT1-DH52441Ant11.012N/APass NVNT1-DH52480Ant11.003N/APass NVNT2-DH52402Ant11.283N/APass NVNT2-DH52441Ant11.289N/APass NVNT2-DH52480Ant11.318N/APass Page 3 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page 4 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page 5 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page 6 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.2 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99% OBW (MHz) NVNT1-DH52402Ant10.881 NVNT1-DH52441Ant10.891 NVNT1-DH52480Ant10.867 NVNT2-DH52402Ant11.191 NVNT2-DH52441Ant11.193 NVNT2-DH52480Ant11.197 Page 7 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT1-DH52402MHzAnt1 OBW NVNT1-DH52441MHzAnt1 Page 8 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity OBW NVNT1-DH52480MHzAnt1 OBW NVNT2-DH52402MHzAnt1 Page 9 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity OBW NVNT2-DH52441MHzAnt1 OBW NVNT2-DH52480MHzAnt1 Page 10 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.3 MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit (dBm)Verdict NVNT1-DH52402Ant10.1521Pass NVNT1-DH52441Ant1021Pass NVNT1-DH52480Ant1-0.6321Pass NVNT2-DH52402Ant10.5521Pass NVNT2-DH52441Ant10.1521Pass NVNT2-DH52480Ant10.0921Pass EIRP ConditionModeFrequency(MHz)Antenna Gain(dBi) EIRP (dBm)Limit (dBm)Verdict NVNT1-DH52402-0.58-0.4336Pass NVNT1-DH52441 -0.58-0.58 36Pass NVNT1-DH52480-0.58-1.2136Pass NVNT2-DH52402 -0.58-0.03 36Pass NVNT2-DH52441-0.58-0.4336Pass NVNT2-DH52480 -0.58-0.49 36Pass Page 11 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page 12 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page 13 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page 14 of 46FCC ID: 2BG4J-V261ReportNo.: LCSA06074048EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.4 CarrierFrequenciesSeparation ConditionModeAntennaHoppingFreq1(MHz)Hoppi


Text truncated - open the document above for the full version.

Test Report

Page 2 of 37 FCCID:2BG4J-V261ReportNo.:LCSA06074048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA06074048EA DateofIssue.......................................:June26,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................: Foslertradecompanylimited Address................................................: FLAT/RM1804BEVERLYHOUSE93-107LOCKHARTROAD WANCHAIHK TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:BLUETOOTHFMSpeaker TradeMark..........................................:N/A TestModel...........................................:V26 Ratings................................................. : Input:5V500mA Result..................................................:Positive Compiledby:Supervisedby:Approvedby: LiHuan/Administrator CaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 37 FCCID:2BG4J-V261ReportNo.:LCSA06074048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA06074048EA June26,2024 Dateofissue TestModel.............................. : V26 EUT......................................... : BLUETOOTHFMSpeaker Applicant...............................:Foslertradecompanylimited Address...................................:FLAT/RM1804BEVERLYHOUSE93-107LOCKHART ROADWANCHAIHK Telephone...............................:/ Fax..........................................:/ Manufacturer.........................: Foslertradecompanylimited Address...................................: FLAT/RM1804BEVERLYHOUSE93-107LOCKHARTROAD WANCHAIHK Telephone...............................: Fax..........................................: Factory...................................: Foslertradecompanylimited Address...................................: FLAT/RM1804BEVERLYHOUSE93-107LOCKHARTROAD WANCHAIHK Telephone...............................:/ Fax..........................................:/ Page 4 of 37 FCCID:2BG4J-V261ReportNo.:LCSA06074048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000June26,2024InitialIssue--- Page 5 of 37 FCCID:2BG4J-V261ReportNo.:LCSA06074048EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION................................................................................................................6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList................................................................................................................................7 1.3.ExternalI/OCable.......................................................................................................................................7 1..............................................................................................................................................................................7 1.4DescriptionofTestFacility..........................................................................................................................7 1.5StatementoftheMeasurementUncertainty.............................................................................................7 1.6MeasurementUncertainty...........................................................................................................................8 1.7DescriptionofTestModes...........................................................................................................................8 2.TESTMETHODOLOGY......................................................................................................................9 2.1EUTConfiguration........................................................................................................................................9 2.2EUTE


Text truncated - open the document above for the full version.

Test Setup Photos

Page2of2FCCID:2BG4J-V261 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3

Contact Information

Applicant

Guangdong Tong
[email protected]075525452114Fax: 075525452114

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.