Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Guide Starplug Tips & Tricks Discover more exciting feature s starpower.world Power On and Network Confi gurati on Get More Safety Information Legal Notices Privacy Protection Please ensure a stable network connection to prevent interruptions that could affect earnings. When connected to power for the first time, the indicator lights up and automatically enters the working state. Press and hold for 2-3 seconds to initiate the network pairing process. At this point, it should be synchronized with the Starpower app, leading you into the wonderful Web3 energy journey. Before using and operating the device, please review and follow all safety information to ensure optimal performance and to avoid hazards or illegal situations. Refer to the nameplate information to ensure that the power source connected to the plug matches the voltage and current requirements specified on the product label. The plug is designed with moisture and dust resistance, but please avoid direct exposure to rain or humidity. Before first use, please ensure that the plug is connected to a power source. Activate the plug according to the instruction manual, and connect it using the APP. The mobile APP allows remote control of the plug, ensure a stable network connection. The front of the plug is equipped with a manual control button for immediate switching. This product complies with relevant safety and electromagnetic compatibility standards, but unauthorized modifications may lead to safety hazards. This guide is for reference only and does not constitute any form of commitment. Please refer to the actual product. If there is any inconsistency between this guide and the official website description, please refer to the official website description without prior notice. To understand how we protect your personal information, please review the privacy policy in the mobile APP. Scan the QR code or visit https://www.starpower.world/user-guide for the latest user guides, information about Starpower products, and the rules. Download the Starpower APP from the app store and follow the guide for operation. ① ② IOSAndroidAptoide FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Starpower Network Co., Ltd. 7 Qibao Street, San Po Kong, Kowloon Hong Kong China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-6-28 To whom it may concern: We, Starpower Network Co., Ltd., hereby certify that the equipment for which authorization is sought (FCC ID: 2BG5R-SP2405US) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Chao Qian Manager Starpower Network Co., Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-6-28> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BG5R-SP2405US SP-2405-US For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Chao Qian/Manager Company: Starpower Network Co., Ltd. Address: 7 Qibao Street, San Po Kong, Kowloon Hong Kong China Phone: 13603034005 Fax: N/A E-Mail: [email protected]
Starpower Network Co., Ltd. 7 Qibao Street, San Po Kong, Kowloon Hong Kong China Date: 2024-6-28 FCC ID: 2BG5R-SP2405US Model Number: SP-2405-US To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, Starpower Network Co., Ltd., declare that this EUT (FCC ID: 2BG5R-SP2405US) doesn’t have Ad Hoc mode function on “non-US/Canada frequencies”. In addition. The frequency selection feature is disabled by firmware for devices marked to the US/Canada. For DTS part of this device, only channels 1-11 will be used in North America, Country code selection is disabled. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Name/Title: Chao Qian/Manager Company: Starpower Network Co., Ltd. Address: 7 Qibao Street, San Po Kong, Kowloon Hong Kong China Phone: 13603034005 Fax: N/A E-Mail: [email protected]
Starpower Network Co., Ltd. 7 Qibao Street, San Po Kong, Kowloon Hong Kong China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-6-28 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BG5R-SP2405US including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Chao Qian/Manager Company: Starpower Network Co., Ltd. Address: 7 Qibao Street, San Po Kong, Kowloon Hong Kong China Phone: 13603034005 Fax: N/A E-Mail: [email protected]
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202406214 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 3 Product Name: StarPlug Model No.: SP-2405-GER EUT Constructional Details External Photo Report No.: HTT202406214 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 3 Report No.: HTT202406214 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 3 of 3 ------End------
Label and Location Size: L: 3.0cm*W: 2.0cm Label and Location FCC ID : 2BG5R-SP2405US
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202406214 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 2 Product Name: StarPlug Model No.: SP-2405-GER EUT Constructional Details Internal Photo Report No.: HTT202406214 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 2 ------End------
RF Exposure evaluation FCC ID: 2BG5R-SP2405US Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Mobile Device 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Antenna Information SP-2405-US can only use antennas certificated as follows provided by manufacturer; Antenna No. Model No. of antenna: Type of antenna: Gain of the antenna (Max.) Frequency range: BT/2.4GWIFI / PCB antenna 4.16dBi for 2400-2500MHz; 5. Manufacturing Tolerance BLE GFSK(Peak) Channel Channel 00 Channel 19 Channel 39 Target (dBm) 2.0 2.0 0.0 Tolerance ±(dB) 1.0 1.0 1.0 2BLE GFSK(Peak) Channel Channel 00 Channel 19 Channel 39 Target (dBm) 2.0 2.0 -1.0 Tolerance ±(dB) 1.0 1.0 1.0 WIFI(Peak) Frequency (MHz) 11b 2412 2437 2462 Target (dBm) 21.0 25.0 20.0 Tolerance ± (dB) 1.0 1.0 1.0 Frequency (MHz) 11g 2412 2437 2462 Target (dBm) 21.0 25.0 21.0 Tolerance ± (dB) 1.0 1.0 1.0 Frequency (MHz) 11n(HT20) 2412 2437 2462 Target (dBm) 20.0 24.0 20.0 Tolerance ± (dB) 1.0 1.0 1.0 Frequency (MHz) 11n(HT40) 2422 2437 2452 Target (dBm) 22.0 24.0 21.0 Tolerance ± (dB) 1.0 1.0 1.0 6. Standalone MPE Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna is 4.16dBi, the RF power density can be obtained. Modulation Type Output power Antenna Gain (dBi) Antenna Gain (linear) MPE (mW/cm 2 ) MPE Limits (mW/cm 2 ) dBm mW BLE 3.0 1.9953 4.16 2.6062 0.0010 1.0000 2.4GWIFI 26.0 398.1072 4.16 2.6062 0.2065 1.0000 Remark: 1. Output power (Peak) including turn-up tolerance; 2. MPE evaluate distance is 20cm from user manual provide by manufacturer. 7. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. ----------------THE END OF REPORT---------------
OTA TEST REPORT TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2008. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Prepared by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 Applicant Espressif System (Shanghai) Co.,Ltd Product ESP32-C3-MINI-1 Model ESP-ANT D-H Report No. Y2102A0260-T2 Issue Date March 9, 2021 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. Test Laboratory .............................................................................................................................. 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test facility ........................................................................................................................ 3 1.3. Testing Location ................................................................................................................ 3 1.4. Laboratory Environment .................................................................................................... 4 2. General Description of Equipment under Test ............................................................................... 5 2.1. Applicant and Manufacturer Information ............................................................................ 5 2.2. General information ........................................................................................................... 5 2.3. Test Date ........................................................................................................................... 5 2.4. Receiving Date .................................................................................................................. 5 2.5. Applied Standards ............................................................................................................. 6 3. Test Conditions .............................................................................................................................. 7 3.1. Test Configuration ............................................................................................................. 7 3.2. Test Measurement ............................................................................................................. 7 4. Test Results ................................................................................................................................... 8 4.1. Gain and Efficiency ............................................................................................................ 8 5. Equipment List ............................................................................................................................... 9 ANNEX A 3-D Pattern Plots ................................................................................................................... 10 ANNEX B:The EUT Appearance and Test Configuration ...................................................................... 12 B.1 EUT Appearance ................................................................................................................... 12 B.2 Test Configuration ................................................................................................................. 13 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform measurement. 1.3. Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1.4. Laboratory Environment Temperature Min. =19°C,Max. = 25°C Relative humidity Min. =40%,Max. =72% Shield effect 0.7-6GHz > 100dB Ground resistance <0.5 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 5 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment under Test 2.1. Applicant and Manufacturer Information Applicant Name Espressif System (Shanghai) Co.,Ltd Applicant address Suite 204 Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China Manufacturer Name Espressif System (Shanghai) Co.,Ltd Manufacturer address Suite 204 Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China 2.2. …
Text truncated - open the document above for the full version.
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202406214F01 This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 37 TEST Report Applicant: Starpower Network Co., Ltd. Address of Applicant: 7 Qibao Street, San Po Kong, Kowloon, Hong Kong Manufacturer : Hangzhou GreenPalm Technology Co.,Ltd. Address of Manufacturer : 2nd Floor, Baoxing Building, No. 4368, Jianshe 4th Road, Xiaoshan District, Hangzhou City, Zhejiang Province Equipment Under Test (EUT) Product Name: StarPlug Model No.: SP-2405-US Series model: N/A Trade Mark: STARPOWER FCC ID: 2BG5R-SP2405US Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: Jun. 11, 2024 Date of Test: Jun. 11, 2024 ~ Jun. 17, 2024 Date of report issued: Jun. 17, 2024 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: HTT202406214F01 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 2 of 37 1. Version Version No. Date Description 00 Jun. 17, 2024 Original Tested/ Prepared By Date: Jun. 17, 2024 Project Engineer Check By: Date: Jun. 17, 2024 Reviewer Approved By : Date: Jun. 17, 2024 Authorized Signature Report No.: HTT202406214F01 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 3 of 37 2. Contents Page 1. VERSION ........................................................................................................................................................ 2 2. CONTENTS .................................................................................................................................................... 3 3. TEST SUMMARY ........................................................................................................................................... 4 4. GENERAL INFORMATION ............................................................................................................................ 5 4.1. GENERAL DESCRIPTION OF EUT ................................................................................................................ 5 4.2. TEST MODE ............................................................................................................................................... 7 4.3. DESCRIPTION OF SUPPORT UNITS .............................................................................................................. 7 4.4. DEVIATION FROM STANDARDS .................................................................................................................... 7 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................... 7 4.6. TEST FACILITY ........................................................................................................................................... 7 4.7. TEST LOCATION ......................................................................................................................................... 7 4.8. ADDITIONAL INSTRUCTIONS ........................................................................................................................ 7 5. TEST INSTRUMENTS LIST ........................................................................................................................... 7 6. TEST RESULTS AND MEASUREMENT DATA ........................................................................................... 9 6.1. CONDUCTED EMISSIONS ............................................................................................................................ 9 6.2. CONDUCTED PEAK OUTPUT POWER ......................................................................................................... 12 6.3. CHANNEL BANDWIDTH .............................................................................................................................. 13 6.4. POWER SPECTRAL DENSITY ..................................................................................................................... 16 6.5. BAND EDGE ............................................................................................................................................. 19 6.5.1. Conducted Emission Method ......................................................................................................... 19 6.5.2. Radiated Emission Method ............................................................................................................ 22 6.6. SPURIOUS EMISSION ................................................................................................................................ 24 6.6.1. Conducted Emission Method ......................................................................................................... 24 6.6.2. Radiated Emission Method ............................................................................................................ 29 6.7. ANTENNA REQUIREMENT .......................................................................................................................... 36 7. TEST SETUP PHOTO .................................................................................................................................. 37 8. EUT CONSTRUCTIONAL DETAILS ........................................................................................................... 37 Report No.: HTT202406214F01 Shenzhen HTT Technology C…
Text truncated - open the document above for the full version.
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202406214F02 This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 33 TEST Report Applicant: Starpower Network Co., Ltd. Address of Applicant: 7 Qibao Street, San Po Kong, Kowloon, Hong Kong Manufacturer : Hangzhou GreenPalm Technology Co.,Ltd. Address of Manufacturer : 2nd Floor, Baoxing Building, No. 4368, Jianshe 4th Road, Xiaoshan District, Hangzhou City, Zhejiang Province Equipment Under Test (EUT) Product Name: StarPlug Model No.: SP-2405-US Series model: N/A Trade Mark: STARPOWER FCC ID: 2BG5R-SP2405US Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: Jun. 11, 2024 Date of Test: Jun. 11, 2024 ~ Jun. 17, 2024 Date of report issued: Jun. 17, 2024 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: HTT202406214F02 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 2 of 33 1. Version Version No. Date Description 00 Jun. 17, 2024 Original Tested/ Prepared By Date: Jun. 17, 2024 Project Engineer Check By: Date: Jun. 17, 2024 Reviewer Approved By : Date: Jun. 17, 2024 Authorized Signature Report No.: HTT202406214F02 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 3 of 33 2. Contents Page 1. VERSION ........................................................................................................................................................ 2 2. CONTENTS .................................................................................................................................................... 3 3. TEST SUMMARY ........................................................................................................................................... 4 4. GENERAL INFORMATION ............................................................................................................................ 5 4.1. GENERAL DESCRIPTION OF EUT ................................................................................................................ 5 4.2. TEST MODE ............................................................................................................................................... 7 4.3. DESCRIPTION OF SUPPORT UNITS .............................................................................................................. 7 4.4. DEVIATION FROM STANDARDS .................................................................................................................... 7 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................... 7 4.6. TEST FACILITY ........................................................................................................................................... 7 4.7. TEST LOCATION ......................................................................................................................................... 7 4.8. ADDITIONAL INSTRUCTIONS ........................................................................................................................ 7 5. TEST INSTRUMENTS LIST ........................................................................................................................... 8 6. TEST RESULTS AND MEASUREMENT DATA ........................................................................................... 9 6.1. CONDUCTED EMISSIONS ............................................................................................................................ 9 6.2. CONDUCTED OUTPUT POWER ...........................................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 342.80 mW |

Ziea One
Equipment Class
DTS - Digital Transmission System