Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CPSeriesDigitalHolterAnalysissystem User’sManual SuzhouBenewareMedicalEquipmentCo.,Ltd. DocumentNo.:BHYL-BZ-SM-0601 Version:V1.0 Time:Aug.2017 RevisionHistory DateVersionChangescomparedtopreviousissue Aug.20171.0Baseversion Statement Firstofall,thankyouforchoosingthisproduct.Beforeapplyingthisinstrument,pleasereadthis instructionmanualcarefullyandmakesuretoobservesafetyprecautions. Thismanualisreferencematerialforproductoperating,maintainingandrepairing.Usersshould strictlyobserveitsinstructions,incaseanylossbecausedbyincorrectinstallationorimproper operation,SuzhouBenewareMedicalEquipmentCo.,Ltd.(Beneware)willnotshoulderanylegal liability. Benewarereservescopyrightofallcontentsinthismanual,withoutexplicitwrittenpermitofour company,nooneisallowedtophotocopy,copyortranslateitintootherlanguages. Thisproductmanualcontainsspecialmaterialsprotectedbycopyrightlaw,includingbutlimited totechnicalsecrets,patentinformationandothercommercialsecrets.Theuserisobligedtokeepit confidentialandnodisclosureofanycontentinthismanualshouldbemadetoanirrelevantthird Party. User’spossessionofthismanualdoesn’tmeanauthorizationofcontainedintellectualproperty rightsonthepartofBeneware. SuzhouBenewareMedicalEquipmentCo.,Ltd.reservesrevisionright,updatingrightandfinal interpretationrightofthismanual. ProductInformation Productname:CardioTrakDigitalHolterRecorder Producttype:CP-022,CP-025 LiabilityoftheManufacturer Benewareisresponsibleforsafety,reliabilityandperformanceoftheinstrumentonlyunderthe followingcircumstances,namely:assemblyoperations,expansion,readjustment,improvement andmaintenanceareallconductedbypersonnelrecognizedbyBeneware,electricalinstallation environmentofcorrespondingroomsshouldbeinaccordancewithnationalstandards,and instrumentsareappliedaccordingtooperatinginstructions. Ifrequiredbytheuser,Benewarewillprovidepaidcircuitdiagramandotherinformationtohelp theuserresorttoappropriateandqualifiedtechnicalpersonneltorepairinstrumentpartsprovided byBeneware. Contents 1BRIEFINTRODUCTION..................................................................................1 1.1FunctionalCharacteristics.......................................................................................................1 1.2SafetyStandardRequirements................................................................................................3 1.3SymbolDescription...................................................................................................................3 1.4EnvironmentalRequirements..................................................................................................4 1.5SoftwareInformation.............................................................................错误!未定义书签。 2APPLICATIONCAUTIONS..............................................................................5 3STRUCTURECHARACTERISTICSANDWORKINGPRINCIPLE........8 3.1ElectricalSchematicDiagramandCompendiumofthePrinciple.......................................8 3.2NameandFunctionofEachPart............................................................................................9 4OPERATINGINSTRUCTION........................................................................11 4.1InsertorremoveECGcable...................................................................................................11 4.2TurnontheRecorder..............................................................................................................11 4.3StartRecording........................................................................................................................11 4.4MarkaPatientEvent..............................................................................................................11 4.5StopRecording........................................................................................................................11 4.6TurnofftheRecorder.............................................................................................................12 4.7Rechargethebattery...............................................................................................................12 5USESTEP..........................................................................................................13 5.1InitializetheRecorder............................................................................................................13 5.2PatientPreparation.................................................................................................................13 5.3TurnontheRecorder..............................................................................................................13 5.4StartRecording.......................................................................................................................13 5.5StopRecording........................................................................................................................13 5.6RemovetheElectrodes............................................................................................................13 5.7Datatransmission....................................................................................................................13 5.8ReferenceElectrodesPlacement............................................................................................14 6CAREANDDAILYMAINTENANCE...........................................................18 6.1MaintenanceCycle..................................................................................................................18 6.2MaintenanceMeasures...........................................................................................................18 7NORMALFAULTSANDTROUBLESHOOTING.......................................19 7.1ACInterference.......................................................................................................................19 7.2UnstableBaseline........................................................................................…
Text truncated - open the document above for the full version.
Suzhou Beneware Medical Equipment Co., Ltd. 7F, No.8 Building, Software Park, Suzhou Science and Technology Town Suzhou Jiangsu 215163 China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-7-30 To whom it may concern: We, Suzhou Beneware Medical Equipment Co., Ltd., hereby certify that the equipment for which authorization is sought (FCC ID: 2BG66-CP-025) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Yezi Lv RA Suzhou Beneware Medical Equipment Co., Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
Suzhou Beneware Medical Equipment Co., Ltd. Add: 7F, No.8 Building, Software Park, Suzhou Science and Technology Town Suzhou Jiangsu 215163 China Date: 2024-7-30 FCC ID: 2BG66-CP-025 Dear Sir/Madam, We, Suzhou Beneware Medical Equipment Co., Ltd. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: CardioTrak Digital Holter Analysis System Model no.: CP-025, CP-022 Sincerely, Name/Title: Yezi Lv/RA Company: Suzhou Beneware Medical Equipment Co., Ltd. Address: 7F, No.8 Building, Software Park, Suzhou Science and Technology Town Suzhou Jiangsu 215163 China Phone: 0512-66806855 Fax: N/A E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-7-30> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BG66-CP-025 CP-025 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Yezi Lv/RA Company: Suzhou Beneware Medical Equipment Co., Ltd. Address: 7F, No.8 Building, Software Park, Suzhou Science and Technology Town Suzhou Jiangsu 215163 China Phone: 0512-66806855 Fax: N/A E-Mail: [email protected]
Suzhou Beneware Medical Equipment Co., Ltd. 7F, No.8 Building, Software Park, Suzhou Science and Technology Town Suzhou Jiangsu 215163 China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-7-30 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BG66-CP-025 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Yezi Lv/RA Company: Suzhou Beneware Medical Equipment Co., Ltd. Address: 7F, No.8 Building, Software Park, Suzhou Science and Technology Town Suzhou Jiangsu 215163 China Phone: 0512-66806855 Fax: N/A E-Mail: [email protected]
Page1of5FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9
Page1of1FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L4.0cmxW2.0cm) LabelLocation CardioTrakDigitalHolterAnalysisSystem Model:CP-025 FCCID:2BG66-CP-025
Page1of3FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 BTAntenna
Page1of4FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation Productname:CardioTrakDigitalHolterAnalysisSystem TestModel:CP-025 AdditionalModelNo.:CP-022 ModelDeclaration:PCBboard,structureandinternalofthesemodel(s)arethe same,Sonoadditionalmodelsweretested Powersupply:Input:DC5V100mA Battery:3.7V300mAh HardwareVersion:Ver2.1 SoftwareVersion:Tv511u BluetoothFrequencyRange:2402MHz~2480MHz ChannelNumber:40channelsforBluetoothV5.0(DTS) ChannelSpacing:2MHzforBluetoothV5.0(DTS) ModulationType:GFSKforBluetoothV5.0(DTS) BluetoothVersion:V5.0 AntennaDescription:PCBAntenna,-0.89dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:PortableDevice 2.EvaluationmethodandLimit AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSAR testexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDB procedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulation exposureconditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition,listedbelow,issatisfied.Thesetest exclusionconditionsarebasedonsource-basedtime-averagedmaximumconductedoutputpower oftheRFchannelrequiringevaluation,adjustedfortune-uptolerance,andtheminimumtest separationdistancerequiredfortheexposureconditions.22Theminimumtestseparationdistance isdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresoroutersurfaceof thedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements,toany partofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbythe operatingconfigurationsandexposureconditionsofthetransmitterandapplicablehostplatform requirements,typicallyintheSARmeasurementorSARanalysisreport,accordingtotherequired publishedRFexposureKDBprocedures.WhennootherRFexposuretestingorreportingis required,astatementofjustificationandcompliancemustbeincludedintheequipmentapproval,in lieuoftheSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfiedbefore applyingtheseSARtestexclusionprovisions;forexample,handheldPTTtwo-wayradios,handsets, laptops&tabletsetc.“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison Page2of4FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportablehost platformexposureconditions.ThegranteeisresponsiblefordocumentingthisaccordingtoClassI permissivechangerequirements.AntennasthatqualifyforstandaloneSARtestexclusionmust applytheestimatedstandaloneSARtodeterminesimultaneoustransmissiontestexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantennaconfiguration, adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≤1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≤0.04,andthe[∑ofMPEratios]is≤ 1.0. 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortableDevices RFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices Page3of4FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.ConductedPowerResults [BTLE] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) BTLE 02402 0.62 192440-0.17 392480 0.91 [BT2LE] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) BTLE 02402 -0.89 192440 -0.77 392480 0.31 5.ManufacturingTolerance [BTLE] BTLE(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 [BT2LE] BTLE(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 6.EvaluationResults 6.1StandaloneEvaluation [BTLE] Modef(GHz) Antenna Distance (mm) RFoutputpower SARTest Exclusion Threshold SARTest Exclusion dBmmW BTLE2.48051.01.25890.3965<3.0Yes BT2LE2.48051.01.25890.3965<3.0Yes Remark: 1.Outputpowerincludingtuneuptolerance; 2.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmaccordingtof)insection 4.1isappliedtodetermineSARtestexclusion. Page4of4FCCID:2BG66-CP-025 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-8259133…
Text truncated - open the document above for the full version.
ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page1of10 TestingReport CustomerName:ShenZhenRfstarTechnologyCo.,Ltd ProductName:BluetoothModule SampleModel:RSBRS02ABR ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2021.11.16 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02021.11.16Forthefirsttime,formulateJacksonEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4DUTsetupphotooffreespaceOTAtesting........................................................................6 3.TestResults......................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1S11parameters...........................................................................................................8 3.3.2VSWRdata................................................................................................................8 3.3.3Typicalfreespaceefficiencyandgain......................................................................8 3.3.4Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment Alltheequipmentusedinthereportisfixedin 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date 16probe microwave chamber 3*3*2.5 RFI-LAB-RF -A00 SUNYIELD2021.3.152023.3.14 Network Analyzer E5071C RFI-LAB-RF -A02 Agilent 2021.5.142022.5.13 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2021.5.142022.5.13 1.4Testenvironment Temperature 24.0°C Humidity 55%RH Pressure 100.04kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page5of10 2.SampleInformation 2.1Clientinformation Name ShenZhenRfstarTechnologyCo.,Ltd Address Room601,BlockC,SkyworthBuilding,High-techPark,NanShan District,ShenZhen,China Contacts Mr.Xie Tel 13580115040 E-mail [email protected] 2.2DescriptionofEUT(S) ProductName BluetoothModule SampleModel RSBRS02ABR Size / SerialNo. / TestItem VSWR;Antennagain;Efficiency;Radiationpattern FrequencyRange 2400-2500MHz ReceivedDate 2021.11.15 TestDate 2021.11.15 Remark ThelengthoftheRFcableis65mm ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page6of10 2.3EUTappearance 2.4DUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern VSWR Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty VSWR±0.3 Antennagain ± 1dB Radiationefficiency±10% ReportNo.:RFI-LAB-RF-202111-K01-1 QP030-E11 Page8of10 3.3 Testdata 3.3.1S11parameters 3.3.2VSWRdata 3.3.3Typicalfreespaceefficiencyandgain Frequency/MHz 240024502500 VSWR 1.68881.32641.9040 Frequency/MHz 24002410242024302440245024602470248024902500 PeakGain/dBi -2.16-1.83-1.52-1.13-1.19-0.89-1.01-1.01-1.07-0.94-1.17 E…
Text truncated - open the document above for the full version.
Page1of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity AppendixA RF Test Data for BLE (ConductedMeasurement) ProductName:CardioTrakDigitalHolterAnalysisSystem Test Model:CP-025 EnvironmentalConditions Temperature: 23.8C RelativeHumidity: 52.1% ATM Pressure: 10 0.0 kPa Test Engineer: Jay Luo Supervisedby: Nick Peng Page2of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.1 -6dB Bandwidth ConditionModeFrequency(MHz)Antenna-6 dB Bandwidth(MHz)Limit -6 dB Bandwidth(MHz)Verdict NVNTBLE 1M2402Ant10.661>=0.5Pass NVNTBLE 1M2440Ant10.653>=0.5Pass NVNTBLE 1M2480Ant10.66>=0.5Pass NVNTBLE 2M2402Ant11.163>=0.5Pass NVNTBLE 2M2440Ant11.134>=0.5Pass NVNTBLE 2M2480Ant11.164>=0.5Pass Page3of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTBLE 1M 2402MHzAnt1 -6dBBandwidthNVNTBLE 1M 2440MHzAnt1 Page4of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTBLE 1M 2480MHzAnt1 -6dBBandwidthNVNTBLE 2M 2402MHzAnt1 Page5of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTBLE 2M 2440MHzAnt1 -6dBBandwidthNVNTBLE 2M 2480MHzAnt1 Page6of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.2 MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit (dBm)Verdict NVNTBLE 1M2402Ant10.6230Pass NVNTBLE 1M2440Ant1-0.1730Pass NVNTBLE 1M2480Ant10.9130Pass NVNTBLE 2M2402Ant1-0.8930Pass NVNTBLE 2M2440Ant1-0.7730Pass NVNTBLE 2M2480Ant10.3130Pass Page7of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs PowerNVNTBLE 1M 2402MHzAnt1 PowerNVNTBLE 1M 2440MHzAnt1 Page8of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PowerNVNTBLE 1M 2480MHzAnt1 PowerNVNTBLE 2M 2402MHzAnt1 Page9of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PowerNVNTBLE 2M 2440MHzAnt1 PowerNVNTBLE 2M 2480MHzAnt1 Page10of34FCCID: 2BG66-CP-025ReportNo. : LCSA06034347EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |