Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Realtek1295 series Octa core Thanks very much for choosing our Android TV BOX . In order to make it more convenient for you to use proficiently, we provide you with a user guide. Please read it carefully before using and properly keep it for reference. Preface We do not grant any guarantees as to the contents of the present instruction manual and disclaim contained here is an instruction intended to enable the correct usage and maintenance of the device. We have made every effort to provide the most current information about the product. We reserve itself the right to introduce amendments, changes or translations of the user manual without prior notification thereof. For this reason, we recommend you regularly visit our website in order to obtain the latest information. Statements 1 1 1 1 1 PiecePicture Media Player IR Remote Control Power Adaptor HDMI cable User Guide NameNO. 1 2 3 4 5 Package Contents ★ All new aluminum housing for best cooling ★ Amlogic S905X3, Quad core ARM Coretex-A53 CPU up 750MHz+(DVFS) , ARM G31 MP2 GPU. Powered by Android 9.0 ★ 2G DDR ,16G EMMC ★VP9-10 Profile-2 up to 4Kx2K&60fps ★ H.265 HEVC MP-10@ L5.1 up to 4KX2K@60fps, ★ HDMI 2.0 supported ★Ethernet 10/100/1000Mbps RJ45 port and internal 2.4GHz/5.8GHz Dual Band WiFi. S ★ Composite Audio/Video output, support all television pecification 1 Connection 3 4 Smart your TV,enjoy the life! Audio trackSubtitle Power on/off Eject key Zoom in/out Alphanumeric key Delete Stop Home menu Menu Return Cursor/IR Kodi shortcuts 3D switch during video playback Settings shortcuts Playback shortcuts Forward Next Repeat 0~9 Screen Ratio 16:9 Rewind Previous Arrow keys: up/down/left/right operation Play/Pause Last channel Next channel Volume Up Volume Down Decimal Resolution ratio Mute on/off Information Remote control 2 No signal on the TV Remote control does not respond Some TV cannot display entire screen Cannot turn on your media player Cannot connect to network Problem 1) Check if the HDMI or AV cable is securely connected. 2) Check if you have selected the correct input source on the TV. 1) Check if the power connector is completely plugged into the DC socket of your media player. 2) Check if the power supply is stable. 1) Make sure that the network cable is securely connected and the Ethernet works well. 2) Make sure that WiFi network is connected and the security key for the encrypted network is correct. 3) Make sure that you select the correct IP address settings. 1) Make sure that the batteries are good. 2) Make sure that the distance between the remote control and your media player is no longer than 12 meters. Setup the screen display position of your media player.Used the zoom key on the remote control to select it. Solution Under any circumstances, never try to repair the box by yourself, this will invalidate warranty. Do not open the box due to electric shock risk. If any fault occurs, first check the following instruction before taking the box for repairing. If you are unable to remedy a problem by following hits, consult your dealer for help . Warning Troubleshooting 6 45 Connect the product to the TV Note: Please turn off the TV when you connect the product to TV Connecting the product via HDMI cable Connecting the product via AV cable Connect the power adaptor Setting up the video source Setting up the network Setting up the Wi-Fi network Setting up the ethernet network 16:9 Quickly User Guide Quickly User Guide FCC Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498.
Page1of1FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION Material:tagboard Gule:adhesivesticker Fontcolor:black Labelcolor:white&silverpolyester (Size:L4.0cmxW2.0cm) LabelLocation AndroidTVBox Model:StreamGenie FCCID:2BG9E-STREAMGENIE
Page1of6FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of6FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of6FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of6FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of6FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Page6of6FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11
Page1of9FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation EUT:AndroidTVBox TestModel:StreamGenie AdditionalModelNo.:MAXUltra ModelDeclaration:PCBboard,structureandinternalofthesemodel(s)arethesame,So noadditionalmodelsweretested PowerSupply: Input:5V2A ForACAdapterInput:100-240V~,50/60Hz,0.4AMAX AdapterOutput:5V2000mA HardwareVersion:/ SoftwareVersion:/ WIFI(2.4GBand) FrequencyRange:2412MHz~2462MHz ChannelNumber:11Channelsfor20MHzbandwidth(2412~2462MHz) 7Channelsfor40MHzbandwidth(2422~2452MHz) ChannelSpacing:5MHz ModulationType:IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaDescription:Ant0:ExternalAntenna,2.29dBi(Max.) Ant1:ExternalAntenna,2.29dBi(Max.) WIFI(5.2GBand) FrequencyRange:5180MHz~5240MHz ChannelNumber:4channelsfor20MHzbandwidth(5180MHz~5240MHz) 2channelsfor40MHzbandwidth(5190MHz~5230MHz) 1channelsfor80MHzbandwidth(5210MHz) ModulationType:IEEE802.11a:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11ac:OFDM(256QAM,64QAM,16QAM,QPSK,BPSK) AntennaDescription:Ant0:ExternalAntenna,2.79dBi(Max.) Ant1:ExternalAntenna,2.79dBi(Max.) WIFI(5.8GBand) FrequencyRange:5745MHz~5825MHz ChannelNumber:5channelsfor20MHzbandwidth(5745MHz~5825MHz) 2channelsfor40MHzbandwidth(5755MHz~5795MHz) 1channelsfor80MHzbandwidth(5775MHz) ModulationType:IEEE802.11a:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11ac:OFDM(256QAM,64QAM,16QAM,QPSK,BPSK) AntennaDescription:Ant0:ExternalAntenna,2.79dBi(Max.) Ant1:ExternalAntenna,2.79dBi(Max.) Page2of9FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Exposurecategory : Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthe sumoftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoes notapplywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalent conditions.Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimum testseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmission operations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic, andElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. Page3of9FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatype andantenna number OperatefrequencybandMaximumantennagainNotes External External Antenna 2412MHz~2462MHz 5180MHz~5240MHz 5745MHz~5825MHz 2412MHz~2462MHz,2.29dBi 5180MHz~5240MHz,2.79dBi 5745MHz~5825MHz,2.79dBi WIFI Ant0 External External Antenna 2412MHz~2462MHz 5180MHz~5240MHz 5745MHz~5825MHz 2412MHz~2462MHz,2.29dBi 5180MHz~5240MHz,2.79dBi 5745MHz~5825MHz,2.79dBi WIFI Ant1 Page4of9FCCID:2BG9E-STREAMGENIE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,Shaj…
Text truncated - open the document above for the full version.
QR/RD-P01-06B SPECIFICATION ShenzhenGuandetongElectronicLimited ShenzhenGuandetongElectronicCo.,Ltd. WIFI antenna 2.4G + 5G dual-band, black omnidirectional 2DB antenna, mother (ROHS) ProductSpecification connection frequency range Frequenc 2400-2500MHz 5000-6000MHZ y bandwire name editionA1 Customer partnumber Guandetong partnumber Guandeton gNo RFdesign肖彬 RFManager 刘亮 Structural design 王栋 Structure Manager 王华 Technical Director 叶定坤Date2024-6-19 Customerconfirmation: Doestheassemblymeetyourcompany'srequirements:□OK□NG ConfidentialityrequirementsofShenzhenGuanditongElectronicCo.,Ltd..Thecompany hasproprietarytechnologytoprovidetheinformation,whichshouldbestrictly confidential,itshallnotbedisclosedtoanypersonorcompanywithoutthepriorwritten consentofShenzhenGuanditongElectronicCo.,Ltd.. Address:3/F,TowerD,HuanguanNanmaoyuanIndustrialPark,GuanhuStreet, LonghuaDistrict,Shenzhen.Tel:0755-88298396fax:0755-89733896 http://www.szgdtrf.com catalogue Cover ....................................................................................................... 1 catalogue...................................................................................................... 2 一、 Product pictures ...................................................................................... 3 二、 Product parameters ............................................................................. 3 三、 S11(VSWR 、 Return 、 Smith) ......................................................... 4 四、 Structural drawings........................................................................... 4 五、 Antenna gain and efficiency ........................................................... 5 六、APPLE Chart ....................................................................................... 6 七、 Environmental performance test...................................................... 7 ConfidentialityrequirementsofShenzhenGuanditongElectronicCo.,Ltd..Thecompany hasproprietarytechnologytoprovidetheinformation,whichshouldbestrictly confidential,itshallnotbedisclosedtoanypersonorcompanywithoutthepriorwritten consentofShenzhenGuanditongElectronicCo.,Ltd.. Address:3/F,TowerD,HuanguanNanmaoyuanIndustrialPark,GuanhuStreet, LonghuaDistrict,Shenzhen.Tel:0755-88298396fax:0755-89733896 http://www.szgdtrf.com 一、Productpictures 二、 Productparameters 三、S11(VSWR、Return、Smith) Producttestingparameters Productname Ultrasonicantenna (ModelType) GDT-P2.4-5.8 (ElectricalSpecifications) (FrenquencyRange) (Polarization) perpendicular (Impedance) Radiatio 2400-2500MHz 5000-6000MHZ 50 Ωn Omnidirectional (VSWR) ≦2.0 (Power)50W (Gain)(Bandwidt 2400-2500MHz, 2.29dBi(MAX) 5000-6000MHz, 2.79dBi(MAX) h100M (MechanicalSpecifications) (Dimensions) 108MM±2mm (ChassisColor) Black (Connector) SMA(K) (CableLength) // (ChassisMaterial) ABS+TPE (WorkingTemperature) -40°C-+85°C (LimitTemperature) -40°C-+85°C ConfidentialityrequirementsofShenzhenGuanditongElectronicCo.,Ltd..Thecompany hasproprietarytechnologytoprovidetheinformation,whichshouldbestrictly confidential,itshallnotbedisclosedtoanypersonorcompanywithoutthepriorwritten consentofShenzhenGuanditongElectronicCo.,Ltd.. Address:3/F,TowerD,HuanguanNanmaoyuanIndustrialPark,GuanhuStreet, LonghuaDistrict,Shenzhen.Tel:0755-88298396fax:0755-89733896 http://www.szgdtrf.com 四、 Structuraldrawings ConfidentialityrequirementsofShenzhenGuanditongElectronicCo.,Ltd..Thecompany hasproprietarytechnologytoprovidetheinformation,whichshouldbestrictly confidential,itshallnotbedisclosedtoanypersonorcompanywithoutthepriorwritten consentofShenzhenGuanditongElectronicCo.,Ltd.. Address:3/F,TowerD,HuanguanNanmaoyuanIndustrialPark,GuanhuStreet, LonghuaDistrict,Shenzhen.Tel:0755-88298396fax:0755-89733896 http://www.szgdtrf.com 五. Antennagainandefficiency ConfidentialityrequirementsofShenzhenGuanditongElectronicCo.,Ltd..Thecompany hasproprietarytechnologytoprovidetheinformation,whichshouldbestrictly confidential,itshallnotbedisclosedtoanypersonorcompanywithoutthepriorwritten consentofShenzhenGuanditongElectronicCo.,Ltd.. Address:3/F,TowerD,HuanguanNanmaoyuanIndustrialPark,GuanhuStreet, LonghuaDistrict,Shenzhen.Tel:0755-88298396fax:0755-89733896 http://www.szgdtrf.com 六、 APPLEChart 2400MHZ 2450MHZ 2500MHZ 5000MHZ 5500MHZ 5800MHZ ConfidentialityrequirementsofShenzhenGuanditongElectronicCo.,Ltd..Thecompany hasproprietarytechnologytoprovidetheinformation,whichshouldbestrictly confidential,itshallnotbedisclosedtoanypersonorcompanywithoutthepriorwritten consentofShenzhenGuanditongElectronicCo.,Ltd.. Address:3/F,TowerD,HuanguanNanmaoyuanIndustrialPark,GuanhuStreet, LonghuaDistrict,Shenzhen.Tel:0755-88298396fax:0755-89733896 http://www.szgdtrf.com 七、 Environmentalperformancetest projectProjecttestconditionsSpecifications Storageenvironment Thetesttemperature,humidityandairpressureareasfollowswhenthereis nospecificcondition: 1.Thetemperatureis-30°C~+80°C 2.Relativehumidity:45%-85% 3.Theairpressureis86kpa-106kpa Normalelectricalandmechanical performance Highandlowtemperaturetest 5cyclesbetween70°Cand40°C,thenundernormalconditions1-2H,checktheappearance quality. Thesizeshallmeetthe requirementsand Mechanicalandelectrical performance Constantdampheatresistance test Relativehumidity:95±3%,testtemperature:40°C.Afterlastingfor2h, Theelectricalperformanceshallbemeasuredwithin5minutesafterthetestobjectistaken out,andthetestobjectshallbewithinthenormalrange Part1-2H,checktheappearancequality Thesizeshallmeetthe requirementsand Mechanicalandelectrical performance vibrationtest Vibrationfrequencyrange:10-55HZ,displacementamplitude:0.35MM,accelerationamplitude: 50.0M/s,frequencysweepcycles:30times Normalelectricalandmechanical performance DroptestFreefallfor3timesinthedirectionofmutuallyperpendicularaxesataheightof1M Normalelectricalandmechanical performance
Page1 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity AppendixA RFTestDatafor2.4GWIFI(ConductedMeasurement) ProductName:AndroidTV Box Test Model:StreamGenie EnvironmentalConditions Temperature: 23.8 C RelativeHumidity:52.1% ATM Pressure:10 0.0 kPa Test Engineer:PaddiChen Supervisedby:Nick Peng Page2 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.1-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6 dBBandwidth(MHz)Limit-6 dBBandwidth(MHz)Verdict NVNTb2412Ant09.555>=0.5Pass NVNTb2437Ant09.519>=0.5Pass NVNTb2462Ant09.998>=0.5Pass NVNTg2412Ant016.285>=0.5Pass NVNTg2437Ant013.83>=0.5Pass NVNTg2462Ant015.019>=0.5Pass NVNTn202412Ant015.93>=0.5Pass NVNTn202437Ant014.997>=0.5Pass NVNTn202462Ant015.066>=0.5Pass NVNTn402422Ant035.147>=0.5Pass NVNTn402437Ant035.074>=0.5Pass NVNTn402452Ant033.876>=0.5Pass Page3 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTb 2412MHzAnt0 -6dBBandwidthNVNTb 2437MHzAnt0 Page4 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTb 2462MHzAnt0 -6dBBandwidthNVNTg 2412MHzAnt0 Page5 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTg 2437MHzAnt0 -6dBBandwidthNVNTg 2462MHzAnt0 Page6 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTn20 2412MHzAnt0 -6dBBandwidthNVNTn20 2437MHzAnt0 Page7 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTn20 2462MHzAnt0 -6dBBandwidthNVNTn40 2422MHzAnt0 Page8 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTn40 2437MHzAnt0 -6dBBandwidthNVNTn40 2452MHzAnt0 Page9 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity ConditionModeFrequency(MHz)Antenna-6 dBBandwidth(MHz)Limit-6 dBBandwidth(MHz)Verdict NVNTb2412Ant19.091>=0.5Pass NVNTb2437Ant19.613>=0.5Pass NVNTb2462Ant110.019>=0.5Pass NVNTg2412Ant116.308>=0.5Pass NVNTg2437Ant116.296>=0.5Pass NVNTg2462Ant116.086>=0.5Pass NVNTn202412Ant115.896>=0.5Pass NVNTn202437Ant116.037>=0.5Pass NVNTn202462Ant115.29>=0.5Pass NVNTn402422Ant135.006>=0.5Pass NVNTn402437Ant135.363>=0.5Pass NVNTn402452Ant133.83>=0.5Pass Page10 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTb 2412MHzAnt1 -6dBBandwidthNVNTb 2437MHzAnt1 Page11 of 97FCCID: 2BG9E-STREAMGENIEReportNo.: LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTb 2462MHzAnt1 -6dBBandwidthNVNTg 2412MHzAnt1 Page12 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTg 2437MHzAnt1 -6dBBandwidthNVNTg 2462MHzAnt1 Page13 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto…
Text truncated - open the document above for the full version.
Page40 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs BandEdgeNVNTb 2412MHzAnt1 Ref BandEdgeNVNTb 2412MHzAnt1 Emission Page41 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTb 2462MHzAnt1 Ref BandEdgeNVNTb 2462MHzAnt1 Emission Page42 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTg 2412MHzAnt1 Ref BandEdgeNVNTg 2412MHzAnt1 Emission Page43 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTg 2462MHzAnt1 Ref BandEdgeNVNTg 2462MHzAnt1 Emission Page44 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTn20 2412MHzAnt1 Ref BandEdgeNVNTn20 2412MHzAnt1 Emission Page45 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTn20 2462MHzAnt1 Ref BandEdgeNVNTn20 2462MHzAnt1 Emission Page46 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTn40 2422MHzAnt1 Ref BandEdgeNVNTn40 2422MHzAnt1 Emission Page47 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity BandEdgeNVNTn40 2452MHzAnt1 Ref BandEdgeNVNTn40 2452MHzAnt1 Emission Page48 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.5ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTb2412Ant0-51.2-20Pass NVNTb2437Ant0-51.58-20Pass NVNTb2462Ant0-51.02-20Pass NVNTg2412Ant0-44.88-20Pass NVNTg2437Ant0-46.28-20Pass NVNTg2462Ant0-44.9-20Pass NVNTn202412Ant0-45.19-20Pass NVNTn202437Ant0-45.2-20Pass NVNTn202462Ant0-44.71-20Pass NVNTn402422Ant0-38.24-20Pass NVNTn402437Ant0-40.79-20Pass NVNTn402452Ant0-39.91-20Pass Page49 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA06244062EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add:101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs Tx. SpuriousNVNTb 2412MHzAnt0 Ref Tx. SpuriousNVNTb 2412MHzAnt0 Emission Page50 of 97FCCID: 2BG9E-STREAMGENIEReportNo. : LCSA0624…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 42.20 mW |