ApexToolGroup,LLC FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 8/27/24 U.S.AgentDesignation ApexToolGroup,LLCacknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatestoact astheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2BGBLA140): NameandcompanyofU.S.agent:ApexToolGroup,LLC PhysicalU.S.addressofagent:ApexToolGroup,LLC910RidgebrookRd.Suite200Sparks Maryland21152UnitedStates FRNofU.S.agent:0035404995 EmailaddressofU.S.agent:[email protected] ApexToolGroup,LLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofApexTool Group,LLC. ApexToolGroup,LLCwiththeFRN0035404995acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature JarrettWolf SeniorProductManager ApexToolGroup,LLC Signature JarrettWolf SeniorProductManager ApexToolGroup,LLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
Page1of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8
Page1of1FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L25.5mmxW29.45mm) LabelLocation VehicleCommunicationInterface Model:GWSMARTBT FCCID:2BGBLA140
Page1of3FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 BTAntenna
Page1of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID2BGBLA140 Productname VehicleCommunicationInterface TestModel GWSMARTBT RatingsInput:DC9-36V HardwareVersion/ SoftwareVersion/ BluetoothFrequencyRange 2402MHz~2480MHz ChannelNumber79channelsforBluetoothV5.0(DSS) ChannelSpacing1MHzforBluetoothV5.0(DSS) ModulationTypeGFSK,π/4-DQPSK,8-DPSKforBluetoothV5.0(DSS) BluetoothVersionV5.0 AntennaDescriptionInternalAntenna,3.95dBi(Max.) ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. Page2of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/ ExternalIdentif ication Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Note InternalInternalAntenna2400MHz-2500MHz3.95dBi(Max.)BTAntenna Page3of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.ConductedPower <BT> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 024020.69 3924410.56 782480-0.16 π/4DQPSK 024020.66 3924411.1 7824801.06 8DPSK 02402-0.04 392441-0.02 782480-0.68 7.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 π/4DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)01.01.0 Tolerance±(dB)1.01.01.0 8DPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 Page4of4FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 8.MeasurementResults 8.1StandaloneMPE AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypartoftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparation distance,r=20cm,aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensity canbeobtained. <BT> Band/Mode RFoutputpower AntennaGain (dBi) Antenna Gain (linear) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW GFSK1.01.25893.952.48310.00061.0000 π/4DQPSK2.01.58493.952.48310.00081.0000 8DPSK1.01.25893.952.48310.00061.0000 Remark: 1.Outputpowerincludingtune-uptolerance; 2.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer; 8.2SimultaneousTransmissionMPE 9.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1091fortheuncontrolledRFExposureof mobiledevice. ..…
Text truncated - open the document above for the full version.
1 ShanghaiShangyuanCommunication TechnologyCo.,LTD Antennaadmissionbook Customername:YunjiaProjectname:A200/A140 Workingfrequencyband:BT Hardwareversion:PA200_MB_V0.1_20240228 Shangyuanmaterialspecifications specificationsandmodelsShangYuanmaterialnumberCustomermaterialnumber BTantenna SZ24165IA70 2.1.09.12.010401 Changetheresume Preparation/changedateChangethecontentChangethe person edition 2024.05.09AnewreleaseYangXinA ShangYuanwillsignthecolumn researchand development structure:XuWei examineand verify:ChenMin Quality Engineer:ChenXiaoping ratify:LiBin radio frequency:HeJinzhu examineand verify:HuangXiong Thecustomerwillsignthecolumn electronicengineerprojectmanagerconstructionengineerQualityengineer 2 catalogue AntennaRecognitionLetter.......................................................................................................................................................................2 1、projectinformation......................................................................................................................................................................................2 1.1、Prototypediagram..............................................................................................................................................................................2 1.2、Antennaproductdiagram................................................................................................................................................................3 2、Antennamatchingcircuit.......................................................................................................................................................................3 3、Overalltestdata........................................................................................................................................................................................4 3.1、S11TestMethodDescription...........................................................................................................................................................4 3.2、TestingEnvironment..........................................................................................................................................................................4 3.3、Passivetestingparameters..............................................................................................................................................................5 3.4、ActiveTestData...................................................................................................................................................................................8 4、Prototypeenvironmentprocessingmethod.....................................................................................................................................9 5、Antennainstallationposition.................................................................................................................................................................10 6、Massproductionantennaindicators..................................................................................................................................................10 7、EngineeringDrawing...............................................................................................................................................................................11 8、ReliabilityTestReport..............................................................................................................................................................................12 9、ROHSEnvironmentalProtectionTestReport.................................................................................................................................13 10、Packagingmethod.................................................................................................................................................................................14 3 1、iteminformation 1.1、Prototypediagram 1.2、Antennaproductdiagram 2、Antennamatchingcircuit Nochangeinmatchingcircuit 4 3、Overalltestdata 3.1S11TestMethodDescription TestEquipment:NetworkAnalyzer(AgilentE5071C) Testmethod:Exporta50OhmCABLEcablefromtheinstrumenttestport,connecttheSMAconnectorofthe testdeviceafterthecalibrator,andrecordtheecholossandstandingwaveratiocorrespondingto therelevantfrequencypoint. Thetestschematicdiagramisasfollows: Schematicdiagramofthetest 3.2TestingEnvironment TestSystem:MPS6450Multi-sensorOTAMeasurementSystem(XH-IoT) Testenvironment:temperature22°C±3°C,humidity50%±15% Testequipment:UsethenetworkanalyzerR&SZND/AgilentE5071Cwhentestingthepassivedata Whentestingactivedata,usethecomprehensivemeterAgilent8960/CMW500/SP9500E/SP8315 Network analyzer Testfixture 5 3.3 Passivetestingparameters ReturnLoss-BT frequency(GHZ) 240024502500 VSWR 1.21.11.2 Passiveefficiency-BT Frequency/MhzMaxGain/dBiEfficiency/% 24003.8949.08 24103.9548.58 24203.7846.24 24303.0647.83 24403.0549.46 24503.1849.72 24603.9347.33 24703.2849.21 24803.3249.72 24903.3648.7 25003.0447.21 6 Passivedirectiondiagram-BT RadiationAppleFigure2.4G 4、Prototypeenvironmentprocessingmethod Environmentaltreatmentwithoutunchanged 7 6、Massproductionantennaindicators Whentheantennaisinmassproduction,thestandingwaveratioisusedastheteststandard formassproduction. Basedonthedifferencesoftheprojectitself,thefollowingcriteriaaregiven: Frequency(MHz) Massproductionstandards 2400-2450MHzVSWR(massproductionperformance) <VSWR(recognizedperformance)+0.5 8 7、EngineeringDrawing 9 8、ReliabilityTestReport 10 9、ROHSEnvironmentalProtectionTestReport 11 10、Packagingmethod
Page 1 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity AppendixA RF Test Data for BT (ConductedMeasurement) ProductName:VehicleCommunicationInterface Test Model:GWSMARTBT EnvironmentalConditions Temperature: 23.8 C RelativeHumidity:52.1% ATM Pressure:100.0 kPa Test Engineer:Can Kun Supervisedby:Nick Peng Page 2 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dBBandwidth ConditionModeFrequency(MHz)Antenna-20 dB Bandwidth(MHz)Limit -20 dB Bandwidth(MHz)Verdict NVNT1-DH52402Ant11.019N/APass NVNT1-DH52441Ant10.946N/APass NVNT1-DH52480Ant11.014N/APass NVNT2-DH52402Ant11.29N/APass NVNT2-DH52441Ant11.28N/APass NVNT2-DH52480Ant11.289N/APass NVNT3-DH52402Ant11.293N/APass NVNT3-DH52441Ant11.287N/APass NVNT3-DH52480Ant11.296N/APass Page 3 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page 4 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page 5 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page 6 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT3-DH52402MHzAnt1 -20dBBandwidthNVNT3-DH52441MHzAnt1 Page 7 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT3-DH52480MHzAnt1 Page 8 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.2 MaximumPeak ConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit (dBm)Verdict NVNT1-DH52402Ant10.6921Pass NVNT1-DH52441Ant10.5621Pass NVNT1-DH52480Ant1-0.1621Pass NVNT2-DH52402Ant10.6621Pass NVNT2-DH52441Ant11.121Pass NVNT2-DH52480Ant11.0621Pass NVNT3-DH52402Ant1-0.0421Pass NVNT3-DH52441Ant1-0.0221Pass NVNT3-DH52480Ant1-0.6821Pass Page 9 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page 10 of 60 FCC ID: 2BGBLA140ReportNo.: LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page 11 of 60 FCC ID: 2BGBLA140ReportNo. : LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page 12 of 60 FCC ID: 2BGBLA140ReportNo.: LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT3-DH52402MHzAnt1 PowerNVNT3-DH52441MHzAnt1 Page 13 of 60 FCC ID: 2BGBLA140ReportNo.: LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT3-DH52480MHzAnt1 Page 14 of 60 FCC ID: 2BGBLA140ReportNo.: LCSA07094051EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Ad…
Text truncated - open the document above for the full version.
Page 1 of 35 FCCID:2BGBLA140ReportNo.:LCSA07094051EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR ApexToolGroup,LLC VehicleCommunicationInterface TestModel:GWSMARTBT Preparedfor:ApexToolGroup,LLC Address:910RidgebrookRoad,Suite200Sparks,Maryland21152 Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:July09,2024 Numberoftestedsamples:2 SampleNo. : A240709016-1,A240709016-2 Serialnumber:Prototype DateofTest:July09,2024~July12,2024 DateofReport:July17,2024 Page 2 of 35 FCCID:2BGBLA140ReportNo.:LCSA07094051EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA07094051EA DateofIssue.......................................:July17,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ApexToolGroup,LLC Address................................................:910RidgebrookRoad,Suite200Sparks,Maryland21152 TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:TRF-4-E-148A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnotassume liabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................: VehicleCommunicationInterface TradeMark..........................................:GEARWRENCH TestModel...........................................: GWSMARTBT Ratings.................................................: Input:DC9-36V Result...................................................: Positive Compiledby:Supervisedby:Approvedby: LiHuan/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 35 FCCID:2BGBLA140ReportNo.:LCSA07094051EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA07094051EA July17,2024 Dateofissue TestModel.............................. : GWSMARTBT EUT......................................... : VehicleCommunicationInterface Applicant...............................:ApexToolGroup,LLC Address...................................:910RidgebrookRoad,Suite200Sparks,Maryland21152 Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:ShenzhenXtooltechIntelligentCo.,Ltd. Address...................................: 17&18/F,A2Building,CreativeCity,LiuxianAvenue, NanshanDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Factory..................................: Bao'anBranchofShenzhenXtooltechIntelligentCo., Ltd Address...................................: 2,3,4/F,Building12,TangtouThirdIndustrialZone,Shiyan street,Bao'anDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Page 4 of 35 FCCID:2BGBLA140ReportNo.:LCSA07094051EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July17,2024InitialIssue--- Page 5 of 35 FCCID:2BGBLA140ReportNo.:LCSA07094051EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION................................................................................................................6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList................................................................................................................................7 1.3ExternalI/OCable.........................................................................................................................................7 1.4DescriptionofTestFaci…
Text truncated - open the document above for the full version.
Page1of1FCCID:2BGBLA140 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |