FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Legami S.p.A. SB/
  3. 2BGCL-CTR0001

2BGCL-CTR0001SMART TRACKER

Legami S.p.A. SB
SMART TRACKER - FCC ID 2BGCL-CTR0001 - Legami S.p.A. SB
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 05, 2026
Application Purpose
Original Equipment
Equipment Note
SMART TRACKER
Frequency Range
2402.00000000 - 2480.00000000
Company
Legami S.p.A. SB
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:HOPEKCORPORATIONINC Address:16755CoyoteBushDrUnit84,SanDiego,CA92127UnitedStates FRN:0034562900 ContactName:YangyangXu TelephoneNo:(561)875-9826 E-mail:[email protected] ThisletteristoconfirmthattheUSAgentforServiceofProcessacceptsresponsibilitytoactas alocalrepresentativeonbehalfofLegamiS.p.A.SB TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. Applicant: CompanyName:LegamiS.p.A.SB ProductDescription:SMARTTRACKER FRN:0035406479 GranteeCode:2BGCL FCCID:2BGCL-CTR0001 ContactName:NicolaAlessioPascarella Address:ViaStezzano,18AzzanoSanPaolo24052Italy TelephoneNo:+39035534168 E-mail:[email protected] TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. ThisAgreementisvaliduntil(Permanentlyvalid). Date:2026/7/30 Applicant’sName: LegamiS.p.A.SB USAgentforServiceofProcess’sName: HOPEKCORPORATIONINC Title:ManagerTitle:Manager SignatureSignature

Attestation Statements

Rev 1/26/2023 Legami S.p.A. SB Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: June 23, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BGCL-CTR0001 [Legami S.p.A. SB] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Legami S.p.A. SB] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Nicola Alessio Pascarella Rev 1/26/2023 Legami S.p.A. SB Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: June 23, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BGCL-CTR0001 [Legami S.p.A. SB] certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Nicola Alessio Pascarella

Cover Letter(s)

Legami S.p.A. SB Family models declaration letter June 23, 2026 We Legami S.p.A. SB Of Via Stezzano, 18 Azzano San Paolo 24052 Italy Declare under our sole responsibility that the product FCC ID: 2BGCL-CTR0001 Product: SMART TRACKER Model Number: CTR0002, CTR0001, CTR0003, CTR0004, CTR0005, CTR0006 All the models are the same circuit and module, except the appearance and model No.. Nicola Alessio Pascarella/ Manager E-mail : [email protected] Phone : +39 035534168 Fax : +39 035536973 Address : Via Stezzano, 18 Azzano San Paolo 24052 Italy

Cover Letter(s)

Legami S.p.A. SB Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 30, 2026 Subject; Request for Confidentiality FCC ID: 2BGCL-CTR0001 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Nicola Alessio Pascarella Title: Manager

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Legami S.p.A. SB Date: June 23, 2026 Product Model Number: CTR0002, CTR0001, CTR0003, CTR0004, CTR0005, CTR0006 FCC ID: 2BGCL-CTR0001 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: ď‚· Testing ď‚· Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Title: Manager Email: [email protected] Telephone: +39 035534168 On behalf of: Legami S.p.A. SB

External Photos

Ext Photos Model: CTR0002 Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8

ID Label/Location Info

2632DZJDG0626CN

Internal Photos

Int Photos Model: CTR0002 Photo 1 Photo 2 ANT Photo 3 Photo 4 Photo 5

RF Exposure Info

- Page 1 of 9 - Report No.: HB20260615003E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com RF EXPOSURE Test Report Product: SMART TRACKER Trade Mark: LEGAMI Model Number: CTR0002 FCC ID: 2BGCL-CTR0001 Prepared for Legami S.p.A. SB Via Stezzano, 18 Azzano San Paolo 24052 Italy Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 9 - Report No.: HB20260615003E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 6 2.1 TEST LABORATORY ..................................................................................................................................................... 6 2.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 6 2.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 6 2.4 TEST SOFTWARE ........................................................................................................................................................ 6 3 LIST OF TEST EQUIPMENT .................................................................................................................................. 7 4 RF EXPOSURE..................................................................................................................................................... 8 4.1 STANDALONE SAR TEST EXCLUSION CONSIDERATIONS........................................................................................................ 8 4.1.1. Limit ............................................................................................................................................................ 8 4.1.2. Test Procedures ........................................................................................................................................... 8 4.1.3. Test Result ................................................................................................................................................... 9 - Page 3 of 9 - Report No.: HB20260615003E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com TEST RESULT CERTIFICATION Applicant’s Name ................. : Legami S.p.A. SB Address ................................. : Via Stezzano, 18 Azzano San Paolo 24052 Italy Manufacturer's Name .......... : Legami S.p.A. SB Address ................................. : Via Stezzano, 18 Azzano San Paolo 24052 Italy Product description Product name ........................ : SMART TRACKER Model Number ....................... : CTR0002 Standards ............................. : FCC CFR 47 PART 1 , 1.1310 Test procedure ....................... : KDB 447498 D01 General RF Exposure Guidance v06 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report. Date of Test ........................................... : Date (s) of performance of tests ............. : June 16, 2026~June 23, 2026 Test Result .............................................. : Pass Testing Engineer : ( Z o e Su) Technical Manager : (M i n g L i u) Authorized Signatory : (L e o S u) - Page 4 of 9 - Report No.: HB20260615003E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Revision History Revised No. Date of Issue Description 01 June 23, 2026 Original - Page 5 of 9 - Report No.: HB20260615003E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com 1 General Description 1.1 Description of EUT Product name: SMART TRACKER Model name: CTR0002 Series Model: CTR0001, CTR0003, CTR0004, CTR0005, CTR0006 Different of series model: All the models are the same circuit and module, except the appearance and model No.. Operation …

Text truncated - open the document above for the full version.

Test Report

- Page 1 of 61 - Report No.: HB20260615003E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Test Report Product: SMART TRACKER Trade Mark: LEGAMI Model Number: CTR0002 FCC ID: 2BGCL-CTR0001 Prepared for Legami S.p.A. SB Via Stezzano, 18 Azzano San Paolo 24052 Italy Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 61 - Report No.: HB20260615003E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 6 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 6 1.2 TEST MODE .............................................................................................................................................................. 6 1.3 OPERATION CHANNEL LIST ........................................................................................................................................... 6 1.4 TEST SETUP .............................................................................................................................................................. 7 1.5 POWER SETTING CONFIGURATION PARAMETERS ............................................................................................................... 7 1.6 ANCILLARY EQUIPMENT .............................................................................................................................................. 7 2 SUMMARY OF TEST RESULT ............................................................................................................................... 8 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 9 3.1 TEST LABORATORY ..................................................................................................................................................... 9 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 9 3.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 9 3.4 TEST SOFTWARE ...................................................................................................................................................... 10 4 LIST OF TEST EQUIPMENT .................................................................................................................................11 5 TEST ITEM AND RESULTS ...................................................................................................................................13 5.1 ANTENNA REQUIREMENT .......................................................................................................................................... 13 5.1.1 Standard Requirement ............................................................................................................................. 13 5.1.2 Test Result ................................................................................................................................................. 13 5.2 CONDUCTED EMISSION ............................................................................................................................................. 14 5.2.1 Limits ........................................................................................................................................................ 14 5.2.2 Test Procedures ......................................................................................................................................... 14 5.2.3 Test Setup .................................................................................................................................................. 15 5.2.4 Test Result ................................................................................................................................................. 15 5.3 RADIATED EMISSION ................................................................................................................................................ 18 5.3.1 Limits ........................................................................................................................................................ 18 5.3.2 Test Procedures ......................................................................................................................................... 18 5.3.3 Test Setup .................................................................................................................................................. 18 5.3.4 Test Result ................................................................................................................................................. 19 5.3.5 Band Edge - Radiated ............................................................................................................................... 27 5.4 PEAK OUTPUT POWER ............................................................................................................................................. 35 5.4.1 Limit .....................…

Text truncated - open the document above for the full version.

Test Report

Summary Inverted F Antenna Specification ANT Type Chip Antenna Model Name 2.4G ANT Center Frequency 2400MHz 2500MHz 2500MHz 2.12 2.18 2.20 MAX. Gain 2.20 dBi Azimuth Beam Pattern Omni-directional Manufacture Impedance 50 Ohm 2400 MHz 2450 MHz 2500 MHz Max: 2.3dBi Min: -1.7dBi Scale: 0.5/div Legami S.p.A. SB Via Stezzano, 18 Azzano San Paolo 24052 Italy 2.3 dBi 1.8 dBi 1.3 dBi 0.8 dBi 0.3 dBi - 0.2 dBi - 0.7 dBi - 1.2 dBi - 1.7 dBi Frequency (MHz) Gain (dBi) Max Min 2400 2.12 -0.60 2450 2.18 -1.60 2500 2.20 0.10

Test Setup Photos

- Page 1 of 2 - Photographs of the Test Setup Model: CTR0002 Radiated Emission Below 1GHz Radiated Emission Above 1GHz - Page 2 of 2 - Conducted Emission

Contact Information

Applicant

Nicola Alessio Pascarella
[email protected]Fax: +39 035536973

Technical Contact

HOPEK CORPORATION INCYangyang Xu
[email protected]

16755 Coyote Bush Dr Unit 84, · United States

Test Firm

Shenzhen HongBiao Certification& Testing Co., LtdLeo Su
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.