FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Kangchengtai Industrial Co.,Ltd./
  3. 2BGFV-SPF-PB-01-C

2BGFV-SPF-PB-01-CMicrochip Pet Feeder

Shenzhen Kangchengtai Industrial Co.,Ltd.
Microchip Pet Feeder - FCC ID 2BGFV-SPF-PB-01-C - Shenzhen Kangchengtai Industrial Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 08, 2024
Application Purpose
Original Equipment
Date of Application
Jul 08, 2024
Equipment Note
Microchip Pet Feeder
Frequency Range
0.12500000 - 0.12500000
Company
Shenzhen Kangchengtai Industrial Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modi fications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. .

Attestation Statements

Shenzhen Kangchengtai Industrial Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 6/26/2024 U.S. Agent Designation S henzhen Kangchengtai Industrial Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BGFV-SPF-PB-01-C): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Shenzhen Kangchengtai Industrial Co., Ltd.. Shenzhen Kangchengtai Industrial Co., Ltd. with the FRN 0035433473 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature Qiang Liu Project manager Shenzhen Kangchengtai Industrial Co., Ltd. Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Shenzhen Kangchengtai Industrial Co., Ltd. Address: No. 128, Dayang Road, Fuyong, Baoan District, Shenzhen, Guangdong 518000, China Phone: +86-755-61573588 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-27 Name / Title: Qiang Liu / Project Manager Company: Shenzhen Kangchengtai Industrial Co., Ltd. Address: No. 128, Dayang Road, Fuyong, Baoan District, Shenzhen, Guangdong 518000, China Phone: +86-755-61573588 Fax: +86-755-61573588 E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BGFV-SPF-PB-01-C SPF-PB-01-C We, applicant Company Name: Shenzhen Kangchengtai Industrial Co., Ltd. Address: No. 128, Dayang Road, Fuyong, Baoan District, Shenzhen, Guangdong 518000, China Phone: +86-755-61573588 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-27 Name / Title: Qiang Liu / Project Manager Company: Shenzhen Kangchengtai Industrial Co., Ltd. Address: No. 128, Dayang Road, Fuyong, Baoan District, Shenzhen, Guangdong 518000, China Phone: +86-755-61573588 Fax: +86-755-61573588 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BGFV-SPF-PB-01-C SPF-PB-01-C For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-27 Name / Title: Qiang Liu / Project Manager Company: Shenzhen Kangchengtai Industrial Co., Ltd. Address: No. 128, Dayang Road, Fuyong, Baoan District, Shenzhen, Guangdong 518000, China Phone: +86-755-61573588 Fax: +86-755-61573588 E-Mail: [email protected]

External Photos

Page1of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig8 Page5of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig9 Fig10 Page6of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig11 Fig12 Page7of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig13 Fig14 Page8of8FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig15

ID Label/Location Info

Page1of1FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L8.0cmxW4.0cm) LabelLocation MicrochipPetFeeder Model:SPF-PB-01-C FCCID:2BGFV-SPF-PB-01-C

Internal Photos

Page1of3FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 125KAntenna

RF Exposure Info

RFExposureEvaluationReport 1.ProductInformation FCCID 2BGFV-SPF-PB-01-C Productname MicrochipPetFeeder TestModel SPF-PB-01-C PowerSupply Input:5V1000mA HardwareVersion/ SoftwareVersion/ 125KHz OperatingFrequency125KHz ChannelNumber1channel ModulationTypeASK AntennaDescription InternalAntenna ,0dBi(Max.) ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevices 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)WirelesspowertransferdevicesmustcomplywithRFexposurerequirementsforalldesign configurationsinwhichtheycanoperate.Ataminimum,RFexposuremustbeevaluatedforthe worst-casescenario,typicallywhenthetransmitter,whiledeliveringenergytoaclientdevice,is operatingatmaximumoutputpower.RFexposurecomplianceforequipmentauthorizationmustbe determinedfollowingtheguidanceofKDB447498,whichincludesconsiderationofthedifferenttest requirementsforMobileDeviceandPortableDeviceexposurecategories,asdefinedin§§2.1091and 2.1093oftheRules. 2)TheRFexposurelimits,assetforthin§1.1310,donotcoverthefrequencyrangebelow100kHzfor SpecificAbsorptionRate(SAR)andbelow300kHzforMaximumPermittedExposure(MPE).Inaddition, presentlimitationsofRFexposureevaluationsystemspreventanaccurateevaluationofSARbelow4 MHz.Forthesereasons,aspecificMPE-basedRFExposurecomplianceprocedurefordevicesoperating intheaforementionedlow-frequencyrangeshasbeensetinplace.Thisprocedureisapplicableto EquipmentAuthorizationofallRFdevices,thusincluding,butnotlimitedto,Part18andWPTdevices. Accordingly,for§2.1091-Mobiledevices,theMPElimitsbetween100kHzto300kHzaretobe consideredthesameasthoseat300kHzinTable1of§1.1310,thatis,614V/mand1.63A/m,forthe electricfieldandmagneticfield,respectively.For§2.1093-Portabledevicesbelow4MHzanddownto 100kHz,theMPElimitsin§1.1310(withthe300kHzlimitapplicableallthewaydownto100kHz)can beusedforthepurposeofequipmentauthorizationinlieuofSARevaluations. Furthermore,consistentwithFCC’sequipmentauthorizationRFexposureguidance,anydevice(both portableandmobile)operatingatfrequenciesbelow100kHzisconsideredcompliantforthepurposeof equipmentauthorizationwhentheexternal(unperturbed)temporalpeakfieldstrengthsdonotexceedthe followingreferencelevels: 83V/mfortheelectricfieldstrength(E) and90A/mforthemagneticfieldstrength(H) Thesedatamaybeprovidedthroughmeasurementsand/ornumericalsimulations,andforallthepositions inspacerelevantforanypossiblebodyexposure. 3)“Largesize”probesmaypreventthemeasurementofE-and/orH-fieldsnearthesurfaceofthe radiatingstructure(e.g.,aWPTsourcecoil),asintheexampleshowninFigure1. Ifthecenteroftheprobesensingelementislocatedmorethan5mmfromtheprobeoutersurface,the fieldstrengthsneedtobeestimatedthroughmodelingforthosepositionsthatarenotreachable.The estimatesmaybedoneeithervianumericalcalculation,orviaanalyticmodel:e.g.,approximatedformulas forcircularcoils,dipoles,etc.,maybeacceptableifitisshownthatthemodelisapplicableforthedesign parametersconsidered.Atypicalexampleistheuseofaquasi-staticapproximationformulafora low-frequencymagneticfieldsource.Theseestimatesshallincludepointsspacednomorethan2cmfrom eachother.Thus,intheexampleof Figure1,atleasttheestimatesat0cmand2cmarerequired,whileonlyonepointwouldnotbesufficient. Inaddition,themodelneedstobevalidatedthroughtheprobemeasurementsforthetwoclosestpointsto thedevicesurface,andwith2-cmincrements,asindicatedinFigure1.Inthatexample,thesamemodel mustalsobeappliedtothe4cmand6cmpositions,andthencomparedwiththemeasureddata,for validationpurposes.Thevalidationisconsideredsufficientifa30%agreementbetweenthemodelandthe (E-and/orH-field)probemeasurementsisdemonstrated.Ifsuchalevelofagreementcannotbeshown,a moreaccuratemodel(and/orasmallerprobe)shallbeused. 4)Part18WirelessPowerTransferuptoOne-MeterDistance.ThissectionappliesonlytoWPT transmittersthat,bydesign,canprovidepowertoaloadlocatedatadistancenogreaterthanone meter.Thisdistanceshallbemeasuredbetweentheclosestpointsbetweenthetransmitterandthe receiverenclosuresurfaces.Forinstance,twocoilspositionedasinFigure2-amaybeoperatedand consideredundertheprovisionsofthissection,becausebothreceiversarewithinone-meterdistance fromthetransmitter.However,thecaseinFigure2-bcannotbeconsideredinthesameway,anditis treatedaccordingtotheprescriptionofSection5.3. ForWPTdesignswithmorethanoneradiatingstructurethedistancetotheloadshallbeconsideredasin Figure3,thusmeasuredbetweenthereceiverandtheclosesttransmittingstructure. 3.EvaluationLimit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposureConsiderations forLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCKDBpublication447498D04InterimGeneralRFExposureGuidancev01:RFExposureProcedures andEquipmentAuthorizationPoliciesforMobileandPortableDevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3theEmission-Limits inthefrequencyrangefrom100KHzto300KHzshouldbeassessedversusthelimitsat300KHzin Table1ofCFR47–Section1.310asfollowing(measureddistanceshallbe15cmfromthecenterof theprobetotheedgeofthedevice): E-Fi…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Kangchengtai Industrial Co., Ltd. No. 128, Dayang Road, Fuyong, Baoan District, Shenzhen, Guangdong 518000, China Product Name: Microchip Pet Feeder Model: SPF-PB-01-C We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required.

Test Report

Page1of26FCCID:2BGFV-SPF-PB-01-CReportNo.:LCSA04254014EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR ShenzhenKangchengtaiIndustrialCo.,Ltd. MicrochipPetFeeder TestModel:SPF-PB-01-C Preparedfor:ShenzhenKangchengtaiIndustrialCo.,Ltd. Address:No.128,DayangRoad,Fuyong,BaoanDistrict,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample: April26,2024 Numberoftestedsamples: 2 Samplenumber: A240425021-1,A240425021-2 Samplenumber: Prototype DateofTest: April26,2024~May10,2024 DateofReport:May11,2024 Page2of26FCCID:2BGFV-SPF-PB-01-CReportNo.:LCSA04254014EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA04254014EA DateofIssue.......................................:May11,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:ShenzhenKangchengtaiIndustrialCo.,Ltd. Address................................................:No.128,DayangRoad,Fuyong,BaoanDistrict,Shenzhen,China TestSpecification Standard..............................................:FCCCFR47PART15C/ANSIC63.10:2013 TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription........................:MicrochipPetFeeder TradeMark..........................................: N/A TestModel...........................................: SPF-PB-01-C Ratings.................................................: Input:5V1000mA Result...................................................:Positive Compiledby:Supervisedby:Approvedby: JokerHu/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page3of26FCCID:2BGFV-SPF-PB-01-CReportNo.:LCSA04254014EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA04254014EA May11,2024 Dateofissue TestModel..............................:SPF-PB-01-C EUT.........................................:MicrochipPetFeeder Applicant...............................:ShenzhenKangchengtaiIndustrialCo.,Ltd. Address..................................:No.128,DayangRoad,Fuyong,BaoanDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenKangchengtaiIndustrialCo.,Ltd. Address...................................:No.128,DayangRoad,Fuyong,BaoanDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Factory..................................:ShenzhenKangchengtaiIndustrialCo.,Ltd. Address..................................:No.128,DayangRoad,Fuyong,BaoanDistrict,Shenzhen,China Telephone..............................:/ Fax.........................................:/ Page4of26FCCID:2BGFV-SPF-PB-01-CReportNo.:LCSA04254014EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000May11,2024InitialIssue-- Page5of26FCCID:2BGFV-SPF-PB-01-CReportNo.:LCSA04254014EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.................................................................................................6 1.1.DescriptionofDevice(EUT)......................................................................................................6 1.2.HostSystemConfigurationListandDetails............................................................................7 1.3.ExternalI/O..................................................................................................................................7 1.4.DescriptionofTestFacility..............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2BGFV-SPF-PB-01-C ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotoofLineConductedEmissionsMeasurement Fig.3

Contact Information

Applicant

Qiang Liu
[email protected]0755-61573588Fax: 0755-61573588

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term
Grant Notes
The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing.