FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Robefactory LLC/
  3. 2BGG3-PIXEL

2BGG3-PIXEL18943 Minecraft Black LED Smart Light Pixel Light

Robefactory LLC

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 01, 2024
Application Purpose
Original Equipment
Date of Application
Jun 30, 2024
Equipment Note
18943 Minecraft Black LED Smart Light Pixel Light
Frequency Range
2402.00000000 - 2480.00000000
Company
Robefactory LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

2024-6-20

ID Label/Location Info

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2BGG3-PIXEL 30 mm FCC ID 5 mm

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FM2405WDG0319 RF EXPOSURE REPORT Applicant Robefactory LLC Address 1725 Chaparral Road, Suit 110 Henderson, Las Vegas, Nevada 89044, United States Manufacturer or Supplier Robefactory LLC Address 1725 Chaparral Road, Suit 110 Henderson, Las Vegas, Nevada 89044, United States Product 18943 Minecraft Black LED Smart Light Pixel Light Brand Name N/A Model 18943 Additional Model & Model Difference N/A Date of tests May 28, 2024 ~ Jun. 14, 2024 FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Loren Luo Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Jun. 27, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FM2405WDG0319 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE DEFINE ................................................................................. 5 3. CLASSIFICATION ........................................................................................... 5 4. CALCULATED RESULT OF MAXIMUM CONDUCTED POWER .................... 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FM2405WDG0319 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2405WDG0319 Original release Jun. 27, 2024 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FM2405WDG0319 1. CERTIFICATION FCC ID: 2BGG3-PIXEL PRODUCT: 18943 Minecraft Black LED Smart Light Pixel Light BRAND NAME: N/A MODEL NO.: 18943 ADDITIONAL NO.: N/A APPLICANT: Robefactory LLC STANDARDS: FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FM2405WDG0319 2. RF EXPOSURE DEFINE The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[ √f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where   f(GHz) is the RF channel transmit frequency in GHz   Power and distance are rounded to the nearest mW and mm before calculation   The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GH…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 42 Report Version A Test Report No.: RF2405WDG0319 TEST REPORT Applicant Robefactory LLC Address 1725 Chaparral Road, Suit 110 Henderson, Las Vegas, Nevada 89044, United States Manufacturer or Supplier Robefactory LLC Address 1725 Chaparral Road, Suit 110 Henderson, Las Vegas, Nevada 89044, United States Product 18943 Minecraft Black LED Smart Light Pixel Light Brand Name N/A Model 18943 Additional Model & Model Difference N/A Date of tests May 28, 2024 ~ Jun. 14, 2024 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Loren Luo Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Jun. 27, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 42 Report Version A Test Report No.: RF2405WDG0319 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ...................................................................................... 6 3.2 DESCRIPTION OF TEST MODES ........................................................................................ 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ........................................................... 7 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ..................................................... 10 3.4 DESCRIPTION OF SUPPORT UNITS ................................................................................ 10 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................................. 10 3.6 DUTY CYCLE OF TESET SIGNAL ....................................................................................... 11 4 TEST TYPES AND RESULTS ...................................................................................................... 12 4.1 CONDUCTED EMISSION MEASUREMENT ...................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS .............................................................................................................. 15 4.2 RADIATED EMISSION MEASUREMENT ........................................................................... 17 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 17 4.2.2 TEST INSTRUMENTS ..................................................................................................... 18 4.2.3 TEST PROCEDURES .................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 13 Report Version B Test Report No.: AN2405WDG0319 ANTENNA TEST REPORT Applicant Robefactory LLC Address 1725 Chaparral Road, Suit 110 Henderson, Las Vegas, Nevada 89044, United States Manufacturer or Supplier Robefactory LLC Address 1725 Chaparral Road, Suit 110 Henderson, Las Vegas, Nevada 89044, United States Product Antenna Brand Name N/A Model 18943 Max. Peak Gain 0.35 dBi Date of tests Jun. 11, 2024 Tested by Andy Zhu Supervisor / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Jun. 27, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 13 Report Version B Test Report No.: AN2405WDG0319 TABLE OF CONTENTS 1. MEASUREMENTS SETUP ................................................................................................ 3 1.1 TEST PROCEDURE ............................................................................................... 3 2. MEASUREMENT UNCERTAINTY ..................................................................................... 4 3. SIZE OF THE ANTENNA ................................................................................................... 4 4. TEST INSTRUMENTS ....................................................................................................... 5 5. TEST RESULTS ................................................................................................................. 6 6. PHOTOGRAPHS OF THE TEST CONFIGURATION ....................................................... 13 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 13 Report Version B Test Report No.: AN2405WDG0319 1. MEASUREMENTS SETUP 1.1 TEST PROCEDURE a. The EUT was placed on the rotating table 1.5 meters above the ground at a Fully Anechoic Room, the table was rotated 360 degrees. b. The EUT was set 3 meters away from the receiving antenna, which was mounted on the top of a antenna tower. c. The antenna is 1.5 meters above the ground. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 13 Report Version B Test Report No.: AN2405WDG0319 2. MEASUREMENT UNCERTAINTY Expanded Uncertainty for Measurement (k=2 or 95% confidence level) at Passive antenna test over frequency range 1000MHz-6000MHz is +/- 1.86dB. 3. SIZE OF THE ANTENNA Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 13 Report Version B Test Report No.: AN2405WDG0319 4. TEST INSTRUMENTS Equipment Manufacturer Model No. Serial No. Next Cal. Signal Generator Agilent N5183A MY50140980 Jul. 11, 24 Spectrum Analyzer Rohde&Schwarz FSV40 101003 Jan. 01, 25 Broad-Band Horn Antenna SCHWARZBECK BBHA 9120 D 9120D-1247 Apr. 13, 25 Broad-Band Horn Antenna SCHWARZBECK BBHA 9120 B 00740 Jul. 20, 24 Turn Table MF MF-7802 MF780208191 N/A Controller MF MF-7802 MF780208243 N/A Test Software BV ADT BV ADT Antenna Pattern V6.2 N/A NOTE: 1. The test was performed in Fully Anechoic Room. 2. Equipment are calibrated by calibration laboratory accredited to ISO/IEC 17025 by a mut…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Leon Xie(Quality Manager)
[email protected]13826580795Fax: 075526929902

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.17 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.