Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Vision Future Technology Co., Ltd. U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: March 20, 2026 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BGI8-SMART Shenzhen Vision Future Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, CLF Import and Export Limited (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. CLF Import and Export Limited ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: CLF Import and Export Limited FRN: 0033489683 Address: 1312 17th Street #692, Denver, CO 80202, United States Signature: Contact Person: David Chen Tel: +1 949 254 2565 Email: [email protected] Applicant Company Name: Shenzhen Vision Future Technology Co., Ltd. FRN: 0035451152 Address: 3F, Building D, Jinchi Technology Park, No. 3 Jiuwei 1st Road, Hangcheng St., Baoan Dist., Shenzhen, China Signature: Contact Person: Lemon feng Tel: 18211307641 Email: [email protected]
Rev 1/26/2023 Shenzhen Vision Future Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03-20-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BGI8-SMART [Shenzhen Vision Future Technology Co., Ltd.] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Shenzhen Vision Future Technology Co., Ltd.] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Lemon feng Rev 1/26/2023 Shenzhen Vision Future Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03-20-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BGI8-SMART [Shenzhen Vision Future Technology Co., Ltd.] ce8rtifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Lemon feng
Shenzhen Vision Future Technology Co., Ltd. Date: March 20, 2026 Product Model Number: Smart locator, S7, S20, S21, S22, S23, S24, S25, S26, S27, S28, S29, Smart card, Item locator, Smart tag FCC ID: 2BGI8-SMART To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Lemon feng Contact Listed on FCC Wesbite Title: Sales Manager Tel.: 18211307641 Email: [email protected] On behalf of: Shenzhen Vision Future Technology Co., Ltd.
Shenzhen Vision Future Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: March 26, 2026 Subject; Request for Confidentiality FCC ID: 2BGI8-SMART To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Lemon feng Title: Sales Manager
Shenzhen Vision Future Technology Co., Ltd. (3F, Building D, Jinchi Technology Park, No. 3 Jiuwei 1st Road, Hangcheng St., Baoan Dist., Shenzhen, China) Model Difference Statement DATE: March 20, 2026 Product Model Number: Smart locator, S7, S20, S21, S22, S23, S24, S25, S26, S27, S28, S29, Smart card, Item locator, Smart tag FCC ID: 2BGI8-SMART Dear Sir/Madam, Added models S7, S20, S21, S22, S23, S24, S25, S26, S27, S28, S29, Smart card, Item locator, Smart tag basis of the original product Smart locator The color of appearance and model name of series models listed are different from the main model, but the circuit and the electronic construction are the same, declared by the manufacturer. Sincerely, Name: Lemon feng Title: Manager Company name: Shenzhen Vision Future Technology Co., Ltd. Address: 3F, Building D, Jinchi Technology Park, No. 3 Jiuwei 1st Road, Hangcheng St., Baoan Dist., Shenzhen, China
Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report Annex A. EUT External Photos EUT View 1 Model: Smart locator EUT View 2 Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report EUT View 3 EUT View 4 Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report EUT View 5 EUT View 6
Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report Annex D. Label and Information FCC Label Sample FCC Label Specifications Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Where the EUT is constructed in two or more sections connected by wires and marketed together, the above statement is required to be affixed only to the main control unit. When the EUT is so small or for such use that it is not practicable to place the statement on it, the above information shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. FCC Label Location
Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report Annex B. EUT Internal Photos EUT Internal View 1 EUT Internal View 2 PCB Antenna ANT Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report EUT Internal View 3 EUT Internal View 4 Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report EUT Internal View 5
FCC ID: 2BGI8-SMART RF Exposure Evaluation According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. For BLE Max Conducted Power(dBm) Tune-up Power(dBm) Max Tune-up Power(dBm) Max Power(mW) Frequency(MHz) Min. distance(mm) Calc. thresholds limit -2.13 -2(±1) -1 0.79 2402 5 0.2448745 3.0 So a SAR test is not required
Report No: SSP26020169-1E FCC Test Report Page 1 of 29 FCC TEST REPORT FCC ID: 2BGI8-SMART Report No. : SSP26020169-1E Applicant : Shenzhen Vision Future Technology Co., Ltd. Product Name : Wireless locator Model Name : Smart locator Test Standard : FCC Part 15.247 Date of Issue : 2026-03-02 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.ccuttest.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. Report No: SSP26020169-1E FCC Test Report Page 2 of 29 Test Report Basic Information Applicant..................................: Shenzhen Vision Future Technology Co., Ltd. Address of Applicant...............: 3F, Building D, Jinchi Technology Park, No. 3 Jiuwei 1st Road, Hangcheng St., Baoan Dist., Shenzhen, China Manufacturer..........................: Shenzhen Vision Future Technology Co., Ltd. Address of Manufacturer........: 3F, Building D, Jinchi Technology Park, No. 3 Jiuwei 1st Road, Hangcheng St., Baoan Dist., Shenzhen, China Product Name.........................: Wireless locator Brand Name.............................: - Main Model..............................: Smart locator Series Models..........................: S7, S20, S21, S22, S23, S24, S25, S26, S27, S28, S29, Smart card, Item locator, Smart tag Test Standard..........................: FCC Part 15 Subpart C KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.4-2014 ANSI C63.10-2020 Date of Test .............................: 2026-02-10 to 2026-02-11 Test Result...............................: PASS Tested By ................................: (Colin Chen) Reviewed By............................: (Lorzix Luo) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. Report No: SSP26020169-1E FCC Test Report Page 3 of 29 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Compliance Standards ...........................................................................................................................................7 1.4 Test Facilities ........................................................................................................................................................7 1.5 List of Measurement Instruments ..........................................................................................................................8 1.6 Measurement Uncertainty .....................................................................................................................................9 2. Summary of Test Results ........................................................................................................................................... 10 3. Antenna Requirement ............................................................................................................................................... 11 3.1 Standard and Limit.............................................................................................................................................. 11 3.2 Test Result .......................................................................................................................................................... 11 4. Radiated Emissions ................................................................................................................................................... 12 4.1 Standard and Limit.............................................................................................................................................. 12 4.2 Test Procedure.................................................................................................................................................... 12 4.3 Test Data and Results .......................................................................................................................................... 14 5. Band-edge Emissions(Radiated) ............................................................................................................................... 18 5.1 Standard and Limit.............................................................................................................................................. 18 5.2 Test Procedure.................................................................................................................................................... 18 5.3 Test Data and Results .......................................................................................................................................... 18 6. Maximum Peak Conducted Output Power ................................................................................................................ 20 6.1 Standard and Limit.............................................................................................................................................. 20 6.2 Test Procedure.................................................................................................................................................... 20 6.3 Test Data and Results ................…
Text truncated - open the document above for the full version.
Summary Inverted F Antenna Specification ITEM ANT SPEC Model Name 2.4G ANT Center Frequency Horizontal Vertical 2400MHz 2400MHz 2500MHz 2400MHz 2400MHz 2500MHz -1.26-0.76-0.58-5.25-2.46-1.86 MAX. Gain -0.58dBi Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Antenna type PCB Antenna Impedance 50 Ohm Manufacture Shenzhen Vision Future Technology Co., Ltd. Address 3F, Building D, Jinchi Technology Park, No. 3 Jiuwei 1st Road, Hangcheng St., Baoan Dist., Shenzhen, China unit:mm Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency (MHz) Gain(dBi) Max Min Avg 2400 -1.26174-30.0801-7.18716 2450 -0.765802-36.5604-7.48023 2500 -0.585582-22.0315-6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dBi) Max Min Avg 2400 -5.2537-22.1424-12.4294 2450 -2.4652-24.5837-10.4702 2500 -1.86120-29.5214-9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.
Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report Annex C. Test Photos Radiated Emission Test View Below 1GHz Radiated Emission Test View Above 1GHz Report No: SSP26020169-1E FCC ID: 2BGI8-SMART Annex of Test Report
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |

Wireless locator
Equipment Class
DTS - Digital Transmission System
Acteril item locator
Equipment Class
DTS - Digital Transmission System
Locator
Equipment Class
DTS - Digital Transmission System