
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Lumirah Pty Ltd Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 6/25/2024 U.S. Agent Designation Lumirah Pty Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BGL6IVI001): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Lumirah Pty Ltd. Lumirah Pty Ltd with the FRN 0035466036 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. S incerely, Signature Michael Winlo Director Lumirah Pty Ltd Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
Page 1 of 4 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page1of1FCCID:2BGL6IVI001 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:3.0cmxW:2.0cm) LabelLocation iViIntelligentVisualInterface Model:myIVI FCCID:2BGL6IVI001
Page 1 of 3 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2BGL6IVI001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Coil Antenna
Page 1 of 13 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information FCC ID: 2BGL6IVI001 Product Name iVi Intelligent Visual Interface Model Number myIVI Power Supply Input: 12.0V6.0A For AC Adapter: Input:100-240V~, 50/60Hz, 1.8A Output: 12.0V6.0A, 72.0W Wireless charging Input: 5V2A, 9V2A, 12V2A Wireless charging output power: 5W, 7.5W, 10W Modulation Type ASK Frequency Range 110.0~205.0KHz Antenna Type Coil Antenna Hardware version / Software version / Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Wireless power transfer devices must comply with RF exposure requirements for all design configurations in which they can operate. At a minimum, RF exposure must be evaluated for the worst-case scenario, typically when the transmitter, while delivering energy to a client device, is operating at maximum output power. RF exposure compliance for equipment authorization must be determined following the guidance of KDB447498, which includes consideration of the different test requirements for Mobile Device and Portable Device exposure categories, as defined in §§ 2.1091 and 2.1093 of the Rules. 2) The RF exposure limits, as set forth in § 1.1310, do not cover the frequency range below 100 kHz for Specific Absorption Rate (SAR) and below 300 kHz for Maximum Permitted Exposure (MPE). In addition, present limitations of RF exposure evaluation systems prevent an accurate evaluation of SAR below 4 MHz. For these reasons, a specific MPE-based RF Exposure compliance procedure for devices operating in the aforementioned low-frequency ranges has been set in place. This procedure is applicable to Equipment Authorization of all RF devices, thus including, but not limited to, Part 18 and WPT devices. Accordingly, for § 2.1091-Mobile devices, the MPE limits between 100 kHz to 300 kHz are to be considered the same as those at 300 kHz in Table 1 of § 1.1310, that is, 614 V/m and 1.63 A/m, for the electric field and magnetic field, respectively. For § 2.1093-Portable devices below 4 MHz and down to 100 kHz, the MPE limits in § 1.1310 (with the 300 kHz limit applicable all the way down to 100 kHz) can be used for the purpose of equipment authorization in lieu of SAR evaluations. Furthermore, consistent with FCC’s equipment authorization RF exposure guidance, any device (both portable and mobile) operating at frequencies below 100 kHz is considered compliant for the purpose of equipment authorization when the external (unperturbed) temporal peak field strengths Page 2 of 13 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity do not exceed the following reference levels: 83 V/m for the electric field strength (E) and 90 A/m for the magnetic field strength (H) These data may be provided through measurements and/or numerical simulations, and for all the positions in space relevant for any possible body exposure. 3) “Large size” probes may prevent the measurement of E- and/or H-fields near the surface of the radiating structure (e.g., a WPT source coil), as in the example shown in Figure 1. If the center of the probe sensing element is located more than 5 mm from the probe outer surface, the field strengths need to be estimated through modeling for those positions that are not reachable. The estimates may be done either via numerical calculation, or via analytic model: e.g., approximated formulas for circular coils, dipoles, etc., may be acceptable if it is shown that the model is applicable for the design parameters considered. A typical example is the use of a quasi-static approximation formula for a low-frequency magnetic field source. These estimates shall include points spaced no more than 2 cm from each other. Thus, in the example of Figure 1, at least the estimates at 0 cm2 and 2 cm are required, while only one point would not be sufficient. In addition, the model needs to be validated through the probe measurements for the two closest points to the device surface, and with 2-cm increments, as indicated in Figure 1. In that example, the same model must also be applied to the 4 cm and 6 cm positions, and then compared with the measured data, for validation purposes. The validation is considered sufficient if a 30% agreement between the model and the (E- and/or H-field) probe measurements is demonstrated. If such a level of agreement cannot be shown, a more accurate model (and/or a smaller probe) shall be used. 4) Part 18 Wireless Power Transfer up to One-Meter Distance. This section applies only to WPT transmitters that, by design, can provide power to a load located at a distance no greater than one meter. This distance shall be measured between the closest points between the transmitter and the receiver enclosure surfaces. For instance, two coils positioned as in Figure 2-a may be operated and considered under the provisions of this section, because both receivers are within one-meter distance from the transmitter. However, the case in Figure 2-b cannot be considered in the same way, and it is treated according to the prescription of Section 5.3. For WPT designs with more than one radiating structure the distance to the load shall be Page 3 of 13 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: …
Text truncated - open the document above for the full version.
承 认 书 SPECIFICATION FOR APPROVAL 客户名称(CUSTOM 科 技 有 限 公 司 客户料号(CUSTOMER P/N): 品名( DESCRIPTION) : DATE:2023-8-8 规格(SPECIFICATION) :MPA2开槽+背胶引线长12mm REV.NO.:A0 鸿日昇威科技承认签 核、 盖 章 部门 确认/日期审核/日期批准/日期 (盖公司公 章) 品质 董晚红 2023-8-8 吕惠 2023-8-8 韦函满 2023-8-8 工程何伟华 2023-8-8 韦立红 2023-8-8 韦立红 2023-8-8 备注: 科技承认签核、盖章 部门 确认/日期审核/日期批准/日期 (盖公司公 章) 开发工 程 采购 品质 备注: 深 圳 市 鸿 日 昇 威 科 技 有 限 公 司 HRSW ELECTRONICS CO.,LTD ADD :深圳市龙华新区观澜环观中路 48 号 1 栋 2 楼 TEL:+86-755-23461055 FAX:+86-0755-28015170 page:1/3 SPECIFICATION FOR APPROVAL 1.MECHANICAL DIMENSION (UNIT:mm) 2.SCHEMATICS: 1.线圈贴磁片,磁片尺寸 50±1mm, 开L线槽。 2.线圈出线位置 缠胶纸 1-2Ts; 3.隔磁片底部要贴背胶 ABC D2EH 50±1.019.5±0.50.9±0.112±34±22.8MAX 3.WINDING: STE P START-FINISHWIRE TYPETURNSTAPE REMAR K N1S-F 丝包线 ⌀0.08*105mm 2UEW12TS (Ref) 4.ELECTRICAL SPECIFICATION: ITEMLDCRLQ值HI-POT TES T CON 线圈加磁片 S-F 100KHz,0.25V AT 25°C SPEC9.6uH±10% 90mΩ Max 5.BILF OF MATERIAL: NO.ITEMMATERIAL SPECIFICATIONMANUFACTURER SGS NO. 1 丝包线0.08*105股丙酮丝包线0.08*105股NANJINGJINNINGCO,LTD 2 无铅锡条无铅锡条 QIAODO 3 磁片 ⌀50锰锌硬磁片开L槽TAIYI CO.,LTD 4 胶水 黄胶9999LIANCHENG CO.,LTD 5 高温胶纸 8mm 宽高温胶纸 CUDAK CO.,LTD 6 背胶 ⌀48.5*0.1CUDAK CO.,LTD HRSW ELECTRONICS CO.,LTD PART NO TITLE MPA2开槽+背胶引线长12mm DRAWN BYCHECKED BY APPROVED BY 何伟华韦立红韦立红 page:2/3 SPECIFICATION FOR APPROVAL 6.SAMPLE TEST DATA 6.1DIMENSION TEST(UNIT:mm) TEST ITEMABCDEH SPEC 50±1.0 19.5±0.50.8±0.0512±3 4±22.8MAX 149.819.80.85123.59 2.45 249.919.980.86113.68 2.48 349.519.90.8711.63.79 2.43 45019.890.8411.73.89 2.41 549.8619.820.8312.034.02 2.40 6 7 8 9 10 MAX50.00 19.98 0.87 12.03 4.02 2.48 MIN49.50 19.80 0.83 11.00 3.59 2.40 AVERAGE49.81 19.88 0.85 11.67 3.79 2.43 6.2ELECTRICAL TEST TEST ITEM LDCRIDC QHI-POT S-FS-F TEST COND100KHz/0.25vAT 25°C SPEC 9.6uH ±10% 90mΩ(Max) 110.04 57.00 29.98 59.00 39.80 59.80 49.96 60.00 59.95 58.50 6 7 8 9 10 MAX10.04 60.00 MIN9.80 57.00 AVERAGE9.95 58.86 HRSW ELECTRONICS CO.,LTD PART NO TITLE MPA2开槽+背胶引线 长12mm DRAWN BYCHECKED BYAPPROVED BY 何伟华韦立红韦立红 page:3/
Page 1 of 27 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Lumirah Pty Ltd iVi Intelligent Visual Interface Test Model: myIVI Prepared for : Lumirah Pty Ltd Address : 61 Stanley Street Nedlands, Western Australia 6009 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 21, 2024 Number of tested samples : 2 Sample No. : A240425061-1, A240425061-2 Serial number : Prototype Date of Test : May 21, 2024 ~ May 29, 2024 Date of Report : May 30, 2024 Page 2 of 27 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. ................. : LCSA05064315EA Date Of Issue ................................. : May 30, 2024 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Lumirah Pty Ltd Address .......................................... : 61 Stanley Street Nedlands, Western Australia 6009 Test Specification Standard ......................................... : FCC CFR 47 PART 15C Test Report Form No...................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : iVi Intelligent Visual Interface Trade Mark ..................................... : N/A Test Model ...................................... : myIVI Power Supply ................................. : Input: 12.0V6.0A For AC Adapter: Input:100-240V~, 50/60Hz, 1.8A Output: 12.0V6.0A, 72.0W Wireless charging Input: 5V2A, 9V2A, 12V2A Wireless charging output power: 5W, 7.5W, 10W Result ........................................... : Positive Compiled by: Supervised by: Approved by: Nadia Zhou/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 27 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA05064315EA May 30, 2024 Date of issue Test Model.......................... : myIVI EUT.................................... : iVi Intelligent Visual Interface Applicant........................... : Lumirah Pty Ltd Address.............................. : 61 Stanley Street Nedlands, Western Australia 6009 Telephone.......................... : / Fax..................................... : / Manufacturer..................... : M-Tek Limited Address.............................. : Unit 1504,15/F., Concordia Plaza, 1 Science Museum Rd..TST East, KIn., Hong Kong Telephone.......................... : / Fax..................................... : / Factory.............................. : / Address.............................. : / Telephone.......................... : / Fax..................................... : / Page 4 of 27 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 30, 2024 Initial Issue --- Page 5 of 27 FCC ID: 2BGL6IVI001 Report No.: LCSA05064315EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION ....................................................................................... 6 1.1 Description of Device (EUT) ........................................................................................... 6 1.2 Su…
Text truncated - open the document above for the full version.
Page1of2FCCID:2BGL6IVI001 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz-ACadapterchargemode Page2of2FCCID:2BGL6IVI001 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RadiatedEmissionbelow1GHz-ACadapterchargemode
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |