Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Thank you for using this product, To make it easier for you to use this product correctly. Please read the User's Guide carefully and keep all the information in a safe place. Smart Toilet Cover Seat With Remote Control Product Manual Warning ● This product must be used correctly. If it is incorrect, it will cause electric shock when failing and leakage. (Construction and confirmation of ground connection, please entrust professionals to do it) ● Do not power the product through an external switch device. (For example: timer or connect to a regular and disconnected circuit that is connected to the general component) ● Be sure to scrub the detergent after cleaning the machine, avoid it remain on the surface of the machine or on the gap between the toilet and the machine. - Do be sure to use the power cord and power plug correctly - If it is improper, it will cause fire or electric shock - Feem the rated 10A. AC 220V power socket. - Please confirm whether the power plug is actually inserted to the end before use. - When you need to unplug the power plug, you must hold the plug body with your hand and unplug it. Do not pull the power cord directly to pull out the power plug. - Do not insert the power plug with a wet hand. - Pay the dust on the power plug regularly. - Reward the power cord and power plug scratching, processing, close to high temperature, forcibly bending, holding, stretching, and laying heavy objectspower cable - At the power plug when you need to repair it, please contact customer service. ● If the soft line of the power supply is damaged in order to avoid danger, it must be replaced by professionals in the manufacturer, its maintenance department or similar department. ● Except for professional maintenance technicians authorized by the company, you must not be transformed, disassembled, and repaired without authorization to avoid causing electric shock, fire, and injury due to abnormal work. ● When the following abnormalities occur in this product, they must be stopped immediately when the failure, and the power plug is removed, the water inlet valve is turned off, and the after -sales service personnel are connected immediately. - The body or casual seat has cracks or damage. - The abnormal sound or scorching smell. - In the power line, the power supply is intermittent. - The power plug or power cord is abnormal. - The body or operation department is hot and abnormal. ● Do not put the lit cigarettes and other combustion into the toilet. ● Do not use tap water and drinking water sources other than water (groundwater). - It will cause water leakage due to impurities in the water or foreign body adhesion. - Cycitis and skin inflammation will cause cystitis and skin inflammation because water contains microorganisms such as bacteria. ● When using the following populations, the temperature of the seat circle should be adjusted to low (long -term contact with the stool and the skin will cause low temperature burns). - Those who are sensitive or slow for children and elderly people, who cannot take temperature regulators, take hypnotic drugs (such as sleeping pills), drunk and extreme fatigue. Notice ● Before using it, confirm whether the leakage protection device is working properly; when the leakage protection device is faulty, the product is used. ● Do not insert it into the opening of this product, so as not to cause electric shock. ● When you do not use this product for a long time, please discharge the water on the water side of the product (please refer to "maintained maintenance"), and then unplug the power plug. ● If the remaining water is discharged the deterioration of water will cause skin inflammation. ● Please abide by the following precautions to avoid injuries. - When handling, you must hold the body with both hands. If you hold the seat or cover with one hand, the body will be injured away from the body. - When the stool and the stool are opened and closed, please be careful not to pinch your fingers. - Do not rely on the cover, it will fall or injury due to the rupture of the stool. - Do not sit above the cover or exert impact, it will fall and injury due to the rupture of the stool. - Do not support the body's control panel to sit down, stand up or sit directly on the control panel, which will cause falling and injury. - When operating the control panel button or closing the toilet cover, do not use brute force, it will cause injuries due to damage. - Do not continue to use it when the body's part is falling off, causing injuries to fall or cause injuries due to rupture. ● Do not let children play this product and accessories, so as not to cause injuries and suffocation. ● People with disabilities and people who lacks experience or common sense (including children) need to use this product under special personnel. ● To connect water source appliances from detachable hose components, it is necessary to replace it with a new hose component. The old hose component cannot be reused. Maintenance instruction 1. Daily maintenance method ● Make sure the power supply is disconnected. ● Do not let the water enter the product inside during the maintenance process. ● Be sure to scrub the detergent after clean the machine, avoid it remain on the surface of the machine or on the gap between the toilet and the machine. 2. Maintenance points ● lean on the surface of the machineC Wipe the machine with a wet and soften cloth. If the machine surface is dirty, you can dip a little of neutral washing detergent on the soften cloth to wipe on it again. ● aintenance of the spray rod (under power supply)M 1. Press the sprinkler self -cleaning key on the remote control without seat on, and the spray rod will extend on automatically. 2. Use a soften wet cloth or brush to wipe on the surface and outlet of the spray rod, be careful the deformation of the spray rod damaged or deformation. 3. Touch the stop button after maintenance, the spray rod will recover to the interior of the machine …
Text truncated - open the document above for the full version.
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: UGK-LVM UNITED INC FRN: 0033476375 Contact Name: Jimmychen Address: 6547NAcademyBlvd#2266,ColoradoSprings,CO80918 Telephone No: 001-323-51 04660 Email: [email protected] Applicant: Company name: Landun Intelligent Home Appliance(Shenzhen) Co.,ltd Grantee code: 2BGOG FCC ID: 2BGOG-LASC405L FRN: 0035483304 Contact Name: mr roh Address: A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China Telephone: 17841021884 Fax: 17841021884 E-mail: [email protected] [Landun Intelligent Home Appliance(Shenzhen) Co.,ltd] certifies that, as of the date of this filing of the application with the TCB, [UGK-LVM UNITED INC] is our designated US agent for service of process for the above referenced FCC ID. [Landun Intelligent Home Appliance(Shenzhen) Co.,ltd] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [UGK-LVM UNITED INC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/05/28 Applicant’s Name: mr roh US Agent for Service of Process’s Name: Jimmychen Title: Manager Title: Manager Signature Signature
C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Landun Intelligent Home Appliance(Shenzhen) Co.,ltd Grantee code: 2BGOG FCC ID: 2BGOG-LASC405L FRN: 0035483304 Contact Name: mr roh Address: A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China Telephone: 17841021884 Fax: 17841021884 E-mail: [email protected] i. [Landun Intelligent Home Appliance(Shenzhen) Co.,ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Landun Intelligent Home Appliance(Shenzhen) Co.,ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Landun Intelligent Home Appliance(Shenzhen) Co.,ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] identified on the Covered List as an entity producing “covered”equipment . Date: 2024/05/28 Applicant’s Name: mr roh Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
Landun Intelligent Home Appliance(Shenzhen) Co.,ltd Product Similarity Declaration Company: Landun Intelligent Home Appliance(Shenzhen) Co.,ltd Address: A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China Product Name: Smart Toilet Cover Seat With Remote Control Model Number: L-ASC-405L L-MSC403-L, L-MSC403-S, L-ASC405-S FCC Identifier: 2BGOG-LASC405L We (Landun Intelligent Home Appliance(Shenzhen) Co.,ltd) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name and appearance color. Client’s signature Name: mr roh Date: 2024-05-28 Title: Manager Signature of applicant:
Landun Intelligent Home Appliance(Shenzhen) Co.,ltd 1/1 Letter of Authorization Company: Landun Intelligent Home Appliance(Shenzhen) Co.,ltd Address: A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China Product Name: Smart Toilet Cover Seat With Remote Control Model Number: L-ASC-405L L-MSC403-L, L-MSC403-S, L-ASC405-S FCC Identifier: 2BGOG-LASC405L We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: mr roh Date: 2024-05-30 Title: Manager Signature of applicant:
Landun Intelligent Home Appliance(Shenzhen) Co.,ltd 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-05-28 Subject: Request for Confidentiality FCC ID: 2BGOG-LASC405L To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual No ☐ Internal Photos No ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Name: mr roh Date: 2024-05-28 Title: Manager Signature of applicant:
Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※
Size:16*8mm Model: L-ASC-405L FCC ID: 2BGOG-LASC405L Label location
Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. ANT Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※
FCC ID: 2BGOG-LASC405L RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=E Meas +20log(d Meas )-104.7 EIRP is the equivalent isotropically radiated power, in dBm E Meas is the field strength of the emission at the measurement distance, in dBμV/m d Meas is the measurement distance, in m Here, Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Frequency (MHz) Min. distance(mm) Calc. thresholds limit 66.04 -29.12 0.00122 315 5 0.00014 3.0 So a SAR test is not required
Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20240424053E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 25 FCC Part 15C Test Report FCC ID: 2BGOG-LASC405L Applicant: Landun Intelligent Home Appliance(Shenzhen) Co.,ltd Address: A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China Manufacturer: Shenzhen Landun Environmental Technology Co.,Ltd Address: A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China EUT: Remote controller for Smart Toilet Cover Seat Trade Mark: WELLBLUE Model Number: L-ASC-405L L-MSC403-L, L-MSC403-S, L-ASC405-S Date of Receipt: Apr. 24, 2024 Test Date: Apr. 24, 2024 - Jun. 03, 2024 Date of Report: Jun. 03, 2024 Prepared By: Shenzhen DL Testing Technology Co., Ltd. (CAB ID:CN0118) Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China Applicable Standards: FCC PART 15 C 15.231 ANSI C63.10:2013 Test Result: Pass Report Number: DL-20240424053E Prepared (Test Engineer): Alisa Song Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20240424053E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 25 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 5 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 6 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 6 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 7 3 . EMC EMISSION TEST 8 3.1 CONDUCTED EMISSION MEASUREMENT 8 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 8 3.1.2 TEST PROCEDURE 8 3.1.3 DEVIATION FROM TEST STANDARD 8 3.1.4 TEST SETUP 9 3.1.5 EUT OPERATING CONDITIONS 9 3.1.6 TEST RESULTS 9 3.2 RADIATED EMISSION MEASUREMENT 10 3.2.1 RADIATED EMISSION LIMITS 10 3.2.2 TEST PROCEDURE 11 3.2.3 DEVIATION FROM TEST STANDARD 11 3.2.4 TEST SETUP 12 3.2.5 EUT OPERATING CONDITIONS 13 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 14 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 15 3.2.8 TEST RESULTS (1GHZ~25GHZ) 18 4 . BANDWIDTH TEST 19 4.1 APPLIED PROCEDURES / LIMIT 19 4.1.1 TEST PROCEDURE 19 4.1.2 DEVIATION FROM STANDARD 19 4.1.3 TEST SETUP 19 4.1.4 EUT OPERATION CONDITIONS 19 4.1.5 TEST RESULTS 20 5 . CALCULATION OF AVERAGE FACTOR 21 5.1 APPLIED PROCEDURES / LIMIT 21 5.1.1 TEST PROCEDURE 21 5.1.2 TEST SETUP 21 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20240424053E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 25 Table of Contents Page 5.1.3 EUT OPERATION CONDITIONS 21 5.1.4 TEST RESULTS 22 6 . DWELL TIME 23 6.1 APPLIED PROCEDURES / LIMIT 23 6.1.1 TEST PROCEDURE 23 6.1.2 DEVIATION FROM STANDARD 23 6.1.3 TEST SETUP 23 6.1.4 EUT OPERATION CONDITIONS 23 6.1.5 TEST RESULTS 24 7 . ANTENNA REQUIREMENT 25 7.1 STANDARD REQUIREMENT 25 7.2 EUT ANTENNA 25 8 . TEST SEUUP PHOTO 25 9 . EUT PHOTO 25 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20240424053E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 25 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.231) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.209,15.231b Fundamental &Radiated Spurious Emission Measurement PASS 15.231a Dwell time PASS 15.231c 20dB Bandwidth PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-20240424053E Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 25 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: Remote controller for Smart Toilet Cover Seat Trademark WELLBLUE Model No.: L-ASC-405L L-MSC403-L, L-MSC403-S, L-ASC405-S Test Model: L-ASC-405L Model Difference The product's different for model number and appearance color. Operation Frequency: 315MHz Channel numbers: 1 Channels Modulation technology: ASK Antenna Type: Internal Antenna Antenna gain: 0 dBi Power supply: RX: 120V~ 60Hz 1300W TX: DC 3V Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2.2 DESCRIPTION OF TEST MODES Note: (1) New battery is used during the test To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectivel…
Text truncated - open the document above for the full version.
Antenna Specifications Manufacturer Shenzhen Landun Environmental Technology Co.,Ltd Address A3-402 Yingzhan Technology Park, No. 8 Longtian Tongfu Road, Longtian Community, Longtian Street, Pingshan District, Shenzhen, China Antenna Type PCB Antenna Gain 0 dBi Test Frequency 315MHz Test Standard ANSI/IEEE Std 149-1979 38.00 mm 9.15 mm 7.30 mm
Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos ※※※※※ END OF REPORT ※※※※※
Shenzhen, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |