FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangzhou Nanyi Information Technology Co., LTD/
  3. 2BGPT-NY-LED-I55

2BGPT-NY-LED-I55Touch all-in-one machine

Guangzhou Nanyi Information Technology Co., LTD
Touch all-in-one machine - FCC ID 2BGPT-NY-LED-I55 - Guangzhou Nanyi Information Technology Co., LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 24, 2024
Application Purpose
Original Equipment
Date of Application
Jun 24, 2024
Equipment Note
Touch all-in-one machine
Frequency Range
2412.00000000 - 2462.00000000
Company
Guangzhou Nanyi Information Technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn Touchall-in-onemachine Productinstructionmanual GuangzhouNanyiInformationTechnologyCo.,LTD GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 目录 1.Productoverview...............................................................................................1st 2.Productpackagingandaccessorieslist......................................................1st 3.Deviceinstallationprocedure......................................................................2nd 4.Usagemethod..................................................................................................2nd 5.Equipmentmaintenanceguide....................................................................6th 6.Precautionsandtaboos..................................................................................6th 7.Troubleshootingandresolution..................................................................7th GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 1st 1.Productoverview Thisproductisahigh-performancelandingdisplaydevicedesignedtomeetthehigh-definition displayneedsofusersinpublicplaces,withthefollowingsignificantfeatures: (1)Slimandbeautifulstructuredesign,streamlinemodeling,sophisticatedtechnology,host systemintegrationultra-thindesign. (2)Usinghigh-performancemaincontrolsystem+HDTFT-LEDLCDscreen,itcanperfectly displaythedetailsofthedisplayscreen. (3)Aluminumalloy+sheetmetalmaterial,takingintoaccountthelightandstructuralstrength ofthewholemachine;Thewholemachineadoptswear-resistantanti-corrosionspraying process,thefrontpaneladoptsexplosion-proofglass,theproductissafeanddurable. 2.Productpackagingandaccessorieslist Serial number NameProductpictureQuantity 1Airframe1piece 2PowercordApieceof 3 WiFiantenna stick Apieceof 4 Product specification /1part 5 Hexagon socketbolt 1 1pack Pleaseensurethatwhenyoureceivetheproduct,theaboveaccessoriesarecompleteandintact. Ifthereisanymissingordamaged,pleasecontacttheafter-salesserviceintime. GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 2nd 3.Deviceinstallationprocedure (1)Takeoutthedeviceandgentlyplaceitonthetable. (2)Takeoutthebase.Onepersonisholdingthebasetoaligntheboltholesatthebasewith thoseatthebottomofthedevice,andanotherpersonisassemblinghexagonalboltsto securethebasetothedevice. (3)ConnecttheWiFiantennasticktotheWiFiantennabaseatthebottomofthebackofthe device. (4)Gentlyliftthefixeddeviceontothegroundandmoveittotheplacewhereitis placed. 4.Usagemethod (1)Beforeusingtheproduct,pleasereadtheproductmanualindetailtounderstandthe functionsandoperationmethodsoftheproduct. (2)Connectthepowercabletothepowersupplyportatthebottomoftherearofthedevice. (3)Ifthedeviceispoweredon,findthepowerswitchatthebottomofthebackofthe device,Adjustthepowerswitchtotheonstate。 (4)ConnecttheHDMIoutputcableofthevideosourcedevicetotheHDMIINportofthe videosourcedevice.Ensurethatthecableistightlyconnected.Thisinterfacesupports HDMI1.4/2.0. Deviceinterfacesaredescribedasfollows: GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 3rd (5)Networkconnection.Beforeconnectingtothenetwork,ensurethattheWiFiantennais installedandthenetworkcableisconnected. 1)IfthedeviceneedstoconnecttoWiFiwirelessnetwork,pleasefollowthestepsshown below GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 4th 2)Ifthedeviceneedstobeconnectedtoawirednetwork,pleasefollowthestepsshown below GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 5th GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 6th 5.Equipmentmaintenanceguide (1)Cleanthesurfaceofthedeviceregularlytoavoidtheaccumulationofdustanddirt. (2)Periodicallycheckthedeviceconnectioncablesandportstoensurestableandreliable connections. (3)Avoidexposingthedevicetohumidity,hightemperature,ordirectsunlight;otherwise,the deviceperformanceandservicelifemaybeaffected. (4)Ifthedeviceisfaultyorabnormal,contacttheafter-salesserviceintime. 6.Precautionsandtaboos (1)Donotdisassembleorrepairthedevicewithoutauthorizationtoavoiddamagetothe deviceorsecurityrisks. (2)Donotexposethedevicetointerferencesourcessuchasstrongmagneticfieldsandstatic electricity.Otherwise,deviceperformancemaybeaffected. (3)Donotusemismatchedpoweradaptersordatacablesonthedevicetoavoiddevice GuangzhouNanyiInformationTechnologyCo.,LTD Add:4/F,No.18-20,RunkeRoad,ZhongxinTown,ZengchengDistrict,Guangzhou Tel:400-0570-898PC:510665Officialwebsite:http://www.southwing.cn 7th damageorsecurityaccidents. (4)Donotexposethedevicetoplaceseasilyaccessibletochildrentoavoidaccidents. 7.Troubleshootingandresolution (1)Ifthedevicefailstobestartedorrunsabnormally,checkwhetherthepowercableis datacableandinterfacearelooseordamaged. (3)Incaseofotherfaultsorabnormalconditions,pleasecontacttheafter-salesservic properlyconnectedandwhetherthepowerswitchisturnedon. (2)Ifthedeviceconnectionisunstableorthedatatransmissionisabnormal,checkwhetherthe e departmentforconsultationandmaintenance. Whentroubleshootingandtroubleshooting,pleaseremaincalmandfollow theinstructions intheproductdescriptiontoavoidfurtherdamagetotheproduct. …

Text truncated - open the document above for the full version.

External Photos

FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55

Internal Photos

FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55 FCCID:2BGPT-NY-LED-I55

RF Exposure Info

Report No.: PTC24111615301E-FC02 Page 1 of 7 FCC TEST REPORT FCC ID: 2BGPT-NY-LED-I55 Product : Touch all-in-one machine Model Name : NY-LED-I55,NY-LED-*** (“ * “represents any value in” A-Z, 0-9 “, only used to distinguish sales regions and sales channels) Brand : Southwing Report No. : PTC24111615301E-FC02 Prepared for Guangzhou Nanyi Information Technology Co., Ltd 4 / F, No. 18-20, Runke Road, Zhongxin Town, Zengcheng District, Guangzhou Prepared by Precise Testing & Certification Co., Ltd. Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China. Report No.: PTC24111615301E-FC02 Page 2 of 7 TEST RESULT CERTIFICATION Applicant’s name : Guangzhou Nanyi Information Technology Co., Ltd Address : 4 / F, No. 18-20, Runke Road, Zhongxin Town, Zengcheng District, Guangzhou Manufacture's name : Guangzhou Nanyi Information Technology Co., Ltd Address : 4 / F, No. 18-20, Runke Road, Zhongxin Town, Zengcheng District, Guangzhou Product name : Touch all-in-one machine Model name : NY-LED-I55,NY-LED-*** (“ * “represents any value in” A-Z, 0-9 “, only used to distinguish sales regions and sales channels) Test procedure : FCC CFR47 Part 1.1307(b)(1) Test Date : Apr. 16, 2024 to Jun. 11, 2024 Date of Issue : Jun. 13, 2024 Test Result : PASS This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Jack zhou / Engineer Technical Manager: Simon Pu / Manager Report No.: PTC24111615301E-FC02 Page 3 of 7 Contents Page 2 TEST SUMMARY .............................................................................................................................................. 4 3 GENERAL INFORMATION ............................................................................................................................. 5 3.1 GENERAL DESCRIPTION OF E.U.T. ......................................................................................................... 5 4 RF EXPOSURE ................................................................................................................................................. 6 4.1 REQUIREMENTS ....................................................................................................................................... 6 4.2 THE PROCEDURES / LIMIT ........................................................................................................................ 6 4.3 MPE CALCULATION METHOD ................................................................................................................. 7 4.4 TEST RESULT .......................................................................................................................................... 7 Report No.: PTC24111615301E-FC02 Page 4 of 7 2 Test Summary Test Items Test Requirement Result Maximum Permissible Exposure (Exposure of Humans to RF Fields) 15.247 (i) PASS Remark: N/A: Not Applicable Report No.: PTC24111615301E-FC02 Page 5 of 7 3 General Information 3.1 General Description of E.U.T. Product Name : Touch all-in-one machine Model Name : NY-LED-I55 Additional model : NY-LED-*** (“ * “represents any value in” A-Z, 0-9 “, only used to distinguish sales regions and sales channels) Specification : 802.11b/g/n HT20/HT40 Operation Frequency : 2412-2462MHz for 802.11b/g/ n(HT20) 2422-2452MHz for 802.11 n(HT40) Number of Channel : 11 channels for 802.11b/g/ n(HT20) 7 channels for 802.11n(HT40) Type of Modulation : DSSS with DBPSK/DQPSK/CCK for 802.11b; OFDM with BPSK/QPSK/16QAM/64QAM for 802.11g/n; Antenna installation : External antenna Antenna Gain : 5.87 dBi Power supply : Input: AC 100-240V~50/60Hz 60A Hardware Version : N/A Software Version : N/A Report No.: PTC24111615301E-FC02 Page 6 of 7 4 RF Exposure Test Requirement : FCC Part 1.1307(b)(1) Evaluation Method : KDB 447498 D01 General RF Exposure Guidance v06 4.1 Requirements Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device. 4.2 The procedures / limit (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm2) Averaging Time |E|2,|H|2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz ; *Plane-wave equivalent power density Report No.: PTC24111615301E-FC02 Page 7 of 7 4.3 MPE Calculation Method E (V/m) = d G P   30 Power Density: Pd (W/m²) = 377 2 E E = Electric field (V/m) P = Peak RF output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = 2 377 30 d G P    θφ From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained 4.4 Test Result Test Mode Test Frequency(M Hz) Antenna Gain (numeric) Max. Peak Output Power (dBm) Tu…

Text truncated - open the document above for the full version.

Test Report

1/4 AntennaSpecification Product:ExternalANT ModelName:NY-LED-I55 Manufacture:GuangzhouNanyiInformationTechnologyCo.,Ltd TestItem:Antennagain;Radiationpatternandefficiency AntennaType:ExternalAntenna FrequencyRange:2400MHz-2500MHz TestData Frequency/MHzEfficiency/dBEfficiency/%MaxGain/dBiAvgGain/dBi 2400-1.4172.284.89-1.41 2410-0.9879.85.87-0.98 2420-1.374.134.81-1.3 2430-0.9580.355.81-0.95 2440-1.1177.454.96-1.11 2450-1.0179.255.48-1.01 2460-0.9779.985.11-0.97 2470-1.0179.255.4-1.01 2480-0.8881.665.2-0.88 2490-1.0877.985.13-1.08 2500-0.8282.795.59-0.82 2/4 (1)X-ZPlane: VPhi=0 (2)Y-ZPlane: VPhi=90 (3)X-YPlane: HTheta=90 3/4 3DPatternfor2400MHz 3DPatternfor2450MHz 4/4 3DPatternfor2500MHz

Test Report

Page 1 of 81 FCC TEST REPORT FCC ID: 2BGPT-NY-LED-I55 Product : Touch all-in-one machine Model Name : NY-LED-I55,NY-LED-*** (“ * “represents any value in” A-Z, 0-9 “, only used to distinguish sales regions and sales channels) Brand : Southwing Report No. : PTC24111615301E-FC01 Prepared for Guangzhou Nanyi Information Technology Co., Ltd 4 / F, No. 18-20, Runke Road, Zhongxin Town, Zengcheng District, Guangzhou Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC24111615301E-FC01 Page 2 of 81 1 TEST RESULT CERTIFICATION Applicant’s name : Guangzhou Nanyi Information Technology Co., Ltd Address : 4 / F, No. 18-20, Runke Road, Zhongxin Town, Zengcheng District, Guangzhou Manufacture's name : Guangzhou Nanyi Information Technology Co., Ltd Address : 4 / F, No. 18-20, Runke Road, Zhongxin Town, Zengcheng District, Guangzhou Product name : Touch all-in-one machine Model name : NY-LED-I55,NY-LED-*** (“ * “represents any value in” A-Z, 0-9 “, only used to distinguish sales regions and sales channels) Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10:2013 Test Date : Apr. 16, 2024 to Jun. 11, 2024 Date of Issue : Jun. 13, 2024 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Jack zhou / Engineer Technical Manager: Simon Pu / Manager Report No.: PTC24111615301E-FC01 Page 3 of 81 Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 5 3 GENERAL INFORMATION ........................................................................................................................................ 6 3.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 6 3.2 CHANNEL LIST .................................................................................................................................................... 7 3.3 TEST SITE ........................................................................................................................................................... 8 4 EQUIPMENT DURING TEST ..................................................................................................................................... 9 4.1 EQUIPMENTS LIST............................................................................................................................................... 9 4.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 11 4.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 5 CONDUCTED EMISSION ......................................................................................................................................... 13 5.1 E.U.T. OPERATION ........................................................................................................................................... 13 5.2 EUT SETUP ...................................................................................................................................................... 13 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................................. 14 5.4 MEASUREMENT PROCEDURE ........................................................................................................................... 14 5.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 5.6 MEASUREMENT DESCRIPTION .......................................................................................................................... 14 5.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 6 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 17 6.1 EUT OPERATION .............................................................................................................................................. 17 6.2 TEST SETUP ..................................................................................................................................................... 18 6.3 SPECTRUM ANALYZER SETUP .......................................................................................................................... 19 6.4 TEST PROCEDURE ............................................................................................................................................ 20 6.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 21 7 CONDUCTED SPURIOUS EMISSION ................................................................................................................... 28 7.1 TEST PROCEDURE ............................................................................................................................................ 28 7.2 TEST SETUP .........................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BGPT-NY-LED-I55 ConductedEmissions RadiatedSpuriousEmissions From30MHz-1000MHz FCCID:2BGPT-NY-LED-I55 Testfrequencyfrom1GHz

Contact Information

Applicant

Peichun Xu(Qualified specialist)
[email protected]+86-17727234203Fax: (8620)85672049

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz109.90 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.