FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD/
  3. 2BGUD-LQ

2BGUD-LQWireless Switch Ceiling Light

ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD
Wireless Switch Ceiling Light - FCC ID 2BGUD-LQ - ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 24, 2024
Application Purpose
Original Equipment
Date of Application
Jun 24, 2024
Equipment Note
Wireless Switch Ceiling Light
Frequency Range
433.92000000 - 433.92000000
Company
ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5UKAIELEC SKU: UBCL01B Wireless Switch Ceiling Light If you have any problems or questions, please contact our Consumer Care. 、 WARNING! To prevent serious injury,including temporary or permanent loss of sight do not stare into the light,shine light into eyes or focus the beam using an additional lens. Keep away from infants and toddlers as this product contains small parts. This product is not a toy! Use this light only as it is intended. Inspect before every use. Do not use if parts are damaged, loose or missing. MOUNT THE CEILING LIGHT 1. Turn the mounting plate on the back of the unit counterclockwise and detach it from the light. 2. Position the flat side of the mounting plate against the desired surface. Use a pencil to mark four points inside the raised screw holes. Insert screws and secure them into the mounting plate with a screwdriver. If mounting to drywall, make sure to use the provided anchors. 3. Align the light over the mounting plate, ensuring the locking tab is in the center of the slot on the back edge of the light. Twist the light clockwise until it securely locks in place. 3 1 2 MOUNT THE WALL SWITCH 1. Install the mounting plate using included screws through the mounting plate. Do not overtighten. 2. Mount the wall switch onto the mounting plate by gently sliding it downward to secure it in place. OPERATION Motion Actived Mode 1. Turn the switch on the back of the light to “AUTO”. 2. The light activates upon detecting motion and automatically turns off after 20 seconds of no motion. Remote Control Mode 1. Turn the switch on the back of the light to “ON”. 2. Press up on the switch to turn the light ON, press down to turn the light OFF. 3. Press and hold the upper of the switch to brighten the light, press and hold the lower of the switch to dim the light. NOTE: There is a 60min. timeout feature that will turn the light OFF to conserve battery life. The wall switch remote will control the light within a 50-foot range. 1 2 CEILING LIGHT BATTERY REPLACEMENT 1. Rotate the light counterclockwise and detach it from the mounting plate. Pull back on both latches of the battery compartment cover and lift it off. 2. Take out the depleted batteries and substitute them with 4 D alkaline batteries, adhering to the diagram inside for proper placement. Reattach the cover and snap it securely into place. Proceed to step 3 in the installation section to re-mount the light onto the mounting plate. Caution: Please replace all batteries simultaneously. Avoid installing batteries backwards, charging, or exposing them to fire. Refrain from mixing old and new batteries. Additionally, do not mix different types of batteries such as alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh, etc.), as this may lead to leakage or explosions. Properly recycle or dispose of old or discharged batteries according to local regulations. WALL SWITCH BATTERY REPLACEMENT 1. To replace the switch’s battery, slide and remove the battery door. 2. Replace with one A23 battery, noting polarity. 3. Replace the battery door and ensure it is firmly closed. SPECIFICATIONS - Model No.: LQ-GY047-R - Battery: 4*D-cell (Not Included) - Remote Range: 50ft (Free Area) - Frequency: 433.92 MHz - Remote Battery: 12V 23A (Included) - Detect Distance: 26ft - Detect Time: 20s - Lumens: 300lm - CCT: 6500K PACKAGE CONTENTS Ceiling Light x 1 Screw & Anchor x 6 Wall Switch x 1 User Manual x 1 FCC Warning Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to whichthe receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement.

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: Companyname:HOPEKCORPORATIONINC FRN:0034562900 ContactName:PeterDavis Address:4358SBANNOCKSTENGLEWOOD,CO80110UnitedStates TelephoneNo:561-235-6113 Email:[email protected] Applicant: Companyname:ZHENGZHOURANYINETWORKTECHNOLOGYCO.,LTD GranteeCode:2BGUD FCCID:2BGUD-LQ FRN:0035518794 ContactName:JinboWei Address:Room916,BuildingB,No.8ShenglongCity,ErqiDistrict,Zhengzhou, HenanProvince,China TelephoneNo: +86-18566010695 FaxNo: / Email: [email protected] ZHENGZHOURANYINETWORKTECHNOLOGYCO.,LTD.certifiesthat,asofthedateofthis filingoftheapplicationwiththeTCB,[HOPEKCORPORATIONINC]isourdesignatedUS agentforserviceofprocessfortheabovereferencedFCCID.ZHENGZHOURANYI NETWORKTECHNOLOGYCO.,LTD.acceptstomaintainanagentfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionofany commissionrelatedproceedinginvolvingequipment.[HOPEKCORPORATIONINC]accepts, asofthedateofthefilingoftheapplication,theobligationofthedesignatedUSagentfor serviceofprocessfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,and clause§2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2024-06-13 Applicant’sName:JinboWeiUSAgent’sName:PeterDavis Title:ProductManagerTitle:CEO Signature:Signature:

Attestation Statements

ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD 6/13/2024 Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province, China RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BGUD-LQ ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Name: Jinbo Wei Title: Product Manager ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD 6/13/2024 Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province, China RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BGUD-LQ ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Name: Jinbo Wei Title: Product Manager

Cover Letter(s)

ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD 6/13/2024 Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province, China RE: CONFIDENTIALITY REQUEST FOR Product Name: Wireless Switch Ceiling Light FCC ID: 2BGUD-LQ Model(s): LQ-GY047-R To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Schematic Diagram, Block Diagram, Operational Description) required to be submitted with this application be permanently withheld from public review. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market Please contact me if there is any information you may need. Sincerely, Signature: June 13, 2024 Name Jinbo Wei Position Product Manager Company Name ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD Address Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province,China Tel +86-18566010695 Fax / Email [email protected]

Cover Letter(s)

ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD 6/13/2024 Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province, China RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen PSI Testing Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: June 13, 2024 Name Jinbo Wei Position Product Manager Company Name ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD Address Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province,China Tel +86-18566010695 Fax / Email [email protected]

External Photos

Page 1 of 3 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix II external photos FCC ID: 2BGUD-LQ Page 2 of 3 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 3 of 3 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------

ID Label/Location Info

Label Location FCC ID: 2BGUD-LQ Model No.: LQ-GY047-R

Internal Photos

Page 1 of 3 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix III internal photos FCC ID: 2BGUD-LQ Page 2 of 3 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TX ANT Page 3 of 3 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------

RF Exposure Info

FCC ID: 2BGUD-LQ Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China RF Exposure evaluation According to 447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison For Worst case Mode: 433.92MHz Field strength =68.15dBuV/m @3m Ant gain 0 dBi; so Ant numeric gain=1 So pt= {[10 (68.15/20) /10 6 x3] 2 /30x1} x 1000 mW =0.0020 mW So (0.0020mW/5mm) x √0.43392 GHz = 0.0003< 3 for 1-g SAR Then SAR evaluation is not required

Test Report

产品规格承认书 Product specifications acknowledgment 承认厂商: (Recognized manufacturers) 制 造 厂 商 : NINGBO BEIMING LIGHTING AND ELECTRONICS TECHNOLOGY CO.,LTD (Manufacturer) 产 品 名 称 : Wireless Switch Ceiling Light (Description) 产品选型表: (Product Type) 型号 说明 备注 LQ-GY047-R 频率为433.92MHZ. 433板载天线 供应商承认签栏 制表者 审核者 核准者 杨妮琴 杨妮琴 第 1 页 共 3 页 1.2 Antenna Picture --我司提供 上图型号:LQ-GY047-R * 第 2 页 共 3 页 産 品 型 號 : DESC LQ-GY047-R 版本 Rev:4.0 一、尺寸 DIMENSION:(mm) 二、原理图 SCHEMATIC DIAGRAM:已有 单位 MM 比列 1:1 。 第 3 页 共 3 页

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao’an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2BGUD-LQ On Behalf of ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD Wireless Switch Ceiling Light Model No.: LQ-GY047-R Prepared for : ZHENGZHOU RANYI NETWORK TECHNOLOGY CO.,LTD Address : Room 916, Building B, No.8 Shenglong City, Erqi District, Zhengzhou, Henan Province, China Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao’an District, Shenzhen, Guangdong, China Report Number : psi2405020-C01-R02 Date of Receipt : May 08, 2024 Date of Test : May 09, 2024- May 14, 2024 Date of Report : May 14, 2024 Version Number : V0 Page 2 of 26 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao’an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Page 1. Summary of Standards And Results ............................................................................................. 5 1.1. Description of Standards and Results .................................................................................... 5 2. General Information ......................................................................................................................... 6 2.1. Description of Device (EUT) ................................................................................................... 6 2.2. Accessories of Device (EUT).................................................................................................. 7 2.3. Tested Supporting System Details ......................................................................................... 7 2.4. Block Diagram of connection between EUT and simulators .................................................. 7 2.5. Test Mode Description ............................................................................................................ 7 2.6. Test Conditions ....................................................................................................................... 8 2.7. Test Facility ............................................................................................................................ 8 2.8. Measurement Uncertainty ...................................................................................................... 8 2.9. Test Equipment List ................................................................................................................ 9 3. Power Line Conducted Emission Test ........................................................................................ 10 3.1. Block Diagram of Test Setup ................................................................................................ 10 3.2. Test Limits ............................................................................................................................ 10 3.3. Configuration of EUT on Test ............................................................................................... 11 3.4. Operating Condition of EUT ................................................................................................. 11 3.5. Test Procedure ..................................................................................................................... 11 3.6. Test Results .......................................................................................................................... 12 4. Radiated Emission Test and Band Edge Test............................................................................. 13 4.1. Block Diagram of Test Setup ................................................................................................ 13 4.2. Test Limit .............................................................................................................................. 14 4.3. Configuration of EUT on Test ............................................................................................... 15 4.4. Operating Condition of EUT ................................................................................................. 15 4.5. Test Procedure ..................................................................................................................... 15 4.6. Test Results .......................................................................................................................... 16 5. Occupied Bandwidth Test ............................................................................................................. 22 5.1. Block Diagram of Test Setup ................................................................................................ 22 5.2. Test Limit .............................................................................................................................. 22 5.3. Test Procedure ..................................................................................................................... 22 5.4. Test Results .......................................................................................................................... 22 6. Transmission time ......................................................................................................................... 23 6.1. Standard Requirement Test limit .......................................................................................... 23 6.2. Method of measurement ....................................................................................................... 23 6.3. Test Setup ...........................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 Report No.: psi2405020-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix I Test Setup Photo FCC ID: 2BGUD-LQ Spurious Radiation Emissions Test (<1G) Spurious Radiation Emissions Test (>1G) ------End------

Contact Information

Applicant

Jinbo Wei(Product Manager)
[email protected]+86-18566010695Fax: /

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]+86 0755-23019820

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term