FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fontem US LLC/
  3. 2BGWXBLUC

2BGWXBLUCBLU C

Fontem US LLC

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 04, 2024
Application Purpose
Original Equipment
Date of Application
Aug 04, 2024
Equipment Note
BLU C
Frequency Range
2402.00000000 - 2480.00000000
Company
Fontem US LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

ID Label/Location Info

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

628 Green Valley Road, Suite 500, Greensboro, NC 27408 Fontem US LLC To: Federal Communications Commission Date: 2024-07-23 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) Fontem US LLC (โ€œthe applicantโ€) certifies that the equipment for which authorization is sought is not โ€œcoveredโ€ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) Fontem US LLC (โ€œthe applicantโ€) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing โ€œcoveredโ€ equipment. Type of Equipment subject to FCC Certification: BLU C FCC ID: 2BGWXBLUC If you have any questions, please feel free to contact me Contact Person: Anuschka Merson Position in the Company: Director, Regulatory and Scientific Affairs Date of Signature: 2024-07-23 ___________________________ Signatory (signature of the applicant)

Attestation Statements

628 Green Valley Road, Suite 500, Greensboro, NC 27408 Fontem US LLC Certification Designating a U.S. Agent for Service of Process Date: 2024-07-23Ref: Section 2.911(d)(7) filing FCC ID: 2BGWXBLUC To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Fontem US LLC (โ€œthe applicantโ€) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID: 2BGWXBLUC. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. U. S. Agent Information: Contact Person: Anuschka Merson Company Name: Fontem US LLC FRN: 0035370402 Company Address: 628 Green Valley Road, Suite 500, Greensboro, NC 27408 Email: [email protected] Sincerely yours, Applicant Company (grantee): Fontem US LLC Contact Person : Anuschka Merson FRN : 0035370402 Company Address : 628 Green Valley Road, Suite 500, Greensboro, NC 27408 Email : [email protected]

Cover Letter(s)

628 Green Valley Road, Suite 500, Greensboro, NC 27408 Confidential Date:2024-07-23 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: Fontem US LLC, the undersigned, hereby authorizes Mrs. Wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Fontem US LLC solely in matters relating to the application for an FCC equipment authorization for FCC ID: 2BGWXBLUC including the signing of documents in connection with this Application. Necessary acts carried out Shenzhen Morlab Communications Technology Co., Ltd. on our behalf of the Fontem US LLC in connection with the Application shall have the same effect as acts of the Fontem US LLC. Fontem US LLC also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti- Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely, Signatory: Contact name : Anuschka Merson Tel : +1 (336) 707-3273 Email : [email protected] Company name : Fontem US LLC

Cover Letter(s)

628 Green Valley Road, Suite 500, Greensboro, NC 27408 Confidential Date: 2024-07-23 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality for FCC ID: 2BGWXBLUC To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionโ€™s Rules (CFR 47), and Section 552(b)(4) of the Freedom of Information Act, Fontem US LLC hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days from grant date as outlined in Public Notice DA04-1705. This provision will give Fontem US LLC temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description PERMANENT 1 Block Diagram 2 Operational Description 3 Schematics SHORT-TERM 4 External Photos 5 Internal Photos 6 Test-Setup Photos 7 User Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Signatory๏ผš Contact name : Anuschka Merson Tel : +1 (336) 707-3273 Email : [email protected] Company name : Fontem US LLC

ID Label/Location Info

I F4 Nino Xu 50** 53** 20240627 A0 A4 Device Housing lased ratio Paper Size ๅทฅ่‰บ๏ผš้“ๆŒค+CNC+ๅ–ท150#็ ‚+้˜ณๆžๆฐงๅŒ–+้•ญ้›•Logo&ๅญ—็ฌฆ Finish:extruding+CNC+sandblasting150#+anodizing+laser engraving Logo&character ้•ญ้›•ๅ›พๆกˆไฝ็ฝฎๅ…ฌๅทฎ+/-0.3mm,ๅฐบๅฏธๅ…ฌๅทฎ+/-0.3mm Postional tolerance of laser carved patterns+/-0.3mm,length and width dimensional tolerance+/-0.3mm ๆ ทๅ“ๆ•ˆๆžœไปฅ็ญพๆ ทไธบๅ‡† 5 . 0 0 m m 8 . 3 5 m m 5 . 0 0 m m 7.10 mm 6 . 5 7 m m 1 . 2 3 m m 2.00 mm 4.03 mm 1 . 2 3 m m 2.00 mm 4.03 mm C3J2111ED FCC ID:2BGWXBLUC 380 380 C3J2111ED 3 . 8 8 m m ๅค–ๅฝขไธญๅฟƒ็บฟ Outline centreline 3.55ใ€10.50mmๆ˜ฏLogoไฝ็ฝฎๅ…ณ้”ฎๅฐบๅฏธ๏ผŒไธบไบ†ๆ”นๅ–„Logoๅฑ…ไธญ๏ผŒ ่ฆๆฑ‚3.55ใ€10.50mm้ฆ–ไปถ่ฐƒๆœบๅฐบๅฏธๅšๅˆฐ+/-0.10mmๅ†…ใ€‚ 3.55 mm 3.55 mm 1 0 . 5 0 m m 1 0 . 5 0 m m 380 C3J2111ED 3 . 6 7 m m FCC ID:2BGWXBLUC 1 . 2 3 m m 2.00 mm 4.03 mm 1 . 2 3 m m 2.00 mm 4.03 mm FCC ID:2BEX2BLUC 380 C3J2111ED 3 . 8 8 m m 3.55 mm 1 . 2 6 m m FCC ID:2BGWXBLUC

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 9 REPORT No.๏ผšSZ23100241S01 RF EXPOSURE EXEMPT REPORT APPLICANT : Fontem US LLC PRODUCT NAME : BLU C MODEL NAME :2.1 BRAND NAME : blu FCC ID : 2BGWXBLUC STANDARD(S) : 47 CFR Part 2(2.1093) RECEIPT DATE : 2023-10-30 TEST DATE :2023-11-26 to 2023-11-30 ISSUE DATE : 2024-07-31 Edited by: Su Xiaoxian (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 9 REPORT No.๏ผšSZ23100241S01 DIRECTORY 1. Technical Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 3 1.1 Applicant and Manufacturer Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 3 1.2 Equipment Under Test (EUT) Description โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 3 1.3 Applied Reference Documents โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 4 2. Device Category and RF Exposure Limit โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 5 3. Maximum Average Power Summary โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 6 4. RF Exposure Assessment โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 7 Annex A Testing Laboratory Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 9 Change History Version Date Reason for change 1.0 2024-07-31 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 9 REPORT No.๏ผšSZ23100241S01 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Fontem US LLC Applicant Address: 628 Green Valley Road, Greensboro, NC 27408 Manufacturer: Shenzhen First Union Technology Co. Ltd Manufacturer Address: Building C,Tangwei High-Technology Park, Fuyong Street, Bao'an District, Shenzhen, Guangdong Province, China 1.2 Equipment Under Test (EUT) Description Product Name: BLU C Sample No.: 5# Hardware Version: V0.20 Software Version: V1.02 Equipment Type: Bluetooth classic Operating Frequency Range: 2402MHz-2480MHz Modulation Type: GFSK Antenna Type: FPC Antenna Antenna Gain: -6.64dBi MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 9 REPORT No.๏ผšSZ23100241S01 1.3 Applied Reference Documents Leading reference documents for testing: Identity Document Title Method Determination /Remark 47 CFR Part 2(2.1093) Radio Frequency Radiation Exposure Assessment: Portable devices No deviation KDB 447498 D04v01 RF Exposure Procedures and Equipment Authorization Policies for Mobile and Portable Devices No deviation Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 2: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 9 REPORT No.๏ผšSZ23100241S01 2. Device Category and RF Exposure Limit Per user manual, based on 47 CFR 2.1093, this device belongs to portable device category with General Population/Uncontrolled exposure. Portable Devices: 47 CFR 2.1093(b) For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. General Population/Uncontrolled Exposure: 47 CFR 2.1093(d) (2) Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the general public may be exposed, or when persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or do not exercise control over their exposure. Warning labels placed on consumer devices such as cellular telephones will not be sufficient reason to allow these devices to be evaluated subject toโ€ฆ

Text truncated - open the document above for the full version.

Test Report

4th Floor, Building B5, Taohuayuan Technology Innovation Ecological Park, Tiegang Community, Xixiang Street, Bao'an District, Shenzhen, China

Test Report

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 72 REPORT No.๏ผšSZ23100241W01 TEST REPORT APPLICANT : Fontem US LLC PRODUCT NAME : BLU C MODEL NAME : 2.1 BRAND NAME : blu FCC ID :2BGWXBLUC STANDARD(S) :47 CFR Part 15 Subpart C RECEIPT DATE : 2023-10-30 TEST DATE : 2023-11-26 to 2023-11-30 ISSUE DATE : 2024-07-31 Edited by: Su Xiaoxian (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 72 REPORT No.๏ผšSZ23100241W01 DIRECTORY 1. Summary of Test Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1.1. Testing Applied Standards ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.2. Test Equipment List ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 1.3. Measurement Uncertainty ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 1.4. Testing Laboratory ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 2. General Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.1. Information of Applicant and Manufacturer ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.2. Information of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.3. Channel List of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 2.4. Test Configuration of EUT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 2.5. Test Conditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 2.6. Test Setup Layout Diagram ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 3. Test Results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 3.1. Antenna Requirement ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 3.2. Duty Cycle of Test Signal ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 3.3. Maximum Peak Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 3.4. Maximum Average Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 3.5. 6 dB Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 3.6. Conducted Spurious Emissions and Band Edge ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 3.7. Power Spectral Density ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 20 3.8. Conducted Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 3.9. Restricted Frequency Bands ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 3.10. Radiated Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 Annex A Test Data and Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 72 REPORT No.๏ผšSZ23100241W01 Change History Version Date Reason for change 1.0 2024-07-31 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 72 REPORT No.๏ผšSZ23100241W01 1. Summary of Test Result No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Nov. 27, 2023 Su Xiaoxian PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Nov. 27, 2023 Su Xiaoxian PASS No deviation 4 15.247(b) Maximum Average Conducted Output Power Nov. 27, 2023 Su Xiaoxian PASS No deviation 5 15.247(a) Bandwidth Nov. 27, 2023 Su Xiaoxian PASS No deviation 6 15.247(d) Conducted Spurious Emission and Band Edge Nov. 27, 2023 Su Xiaoxian PASS No deviation 7 15.247(e) Power Spectral Density Nov. 27, 2023 Su Xiaoxian PASS No deviation 8 15.207 Conducted Emission Nov. 29, 2023 Wang Deyong PASS No deviation 9 15.247(d) Restricted Frequency Bands Nov. 24, 2023 Lin Hanbin PASS No deviation 10 15.209, 15.247(d) Radiated Emission Nov. 24, 2023 Lin Hanbin PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSIC 63.10-2013 and KDB558074 D01 v05r02. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncertainty give the judgment resโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Anuschka Merson(Director, Regulatory and Scientific Affairs)
[email protected]336-707-3273Fax: N/A

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.49 mW
Confidentiality
Long Term
Grant Notes
Output power is maximum peak conducted.