Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
INTRODUCTION The Portable Electronic Key Finder is a device that makes finding keys simple. The everyday hassle of finding lost keys is eliminated with the touch of a button. You can count on an alarm to direct you to your keys. Whether your keys are lying close by or up to 45 feet away, the Portable Electronic Key Finder’s wireless transmitter will locate your keys while being carried in-hand with ease. This package includes a remote transmitter, two key ring fobs, and a tabletop cradle for storage. SAFETY INFORMATION AND WARNINGS All of the safety and operating instructions should be read, understood and followed before the unit is operated. SAFETY WARNINGS- PLEASE READ CAREFULLY • This is not a children’s product. • Small parts, especially the button cell batteries, pose a choking hazard to young children. • If the product appears cracked or broken in any manner, discontinue use and discard immediately. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. PORTABLE ELECTRONIC KEY FINDER IMPORTANT: KEEP THIS INSTRUCTION MANUAL FOR REFERENCE AS IT CONTAINS IMPORTANT SAFETY INFORMATION. INSTRUCTIONS 1 23 45 CONTENTS Safety Information and Warnings . . . . . . . . . . . . . .1 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installing Batteries . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Battery Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 CR2032 LITHIUM BATTERY 3V Fob Front Cover Closing Direction Figure A Figure B INSTALLING BATTERIES FOBS Each requires one CR2032 (3V) button cell battery (included). NOTE: There are four CR2032 button cell batteries included. Two must be installed prior to your first use and the other two are replacements. Follow these steps for first time installation or if the batteries need to be replaced. 1. Grasp the back cover and screw off counterclockwise. See Figure A. 2. Insert a new battery into the metal slot, ensuring the “+” side of the battery is facing up. The FOB will make its characteristic beeping sound as it is inserted into the slot. 3. Replace the back cover by screwing it clockwise back onto the FOB. See Figure B. NOTE: Be sure that the "OPEN" markings are facing the bottom as you screw on the cover. This will ensure that the pieces are properly aligned. OPERATION 1. Attach the number-coded fobs to key rings or other appropriate devices to be located. 2. Press the corresponding number-coded button on the Remote Transmitter in order to locate the desired fob. 3. If the fob is in range (45 feet in an open area), it will emit an audible beep for a few seconds. 4. If no beep is heard, intermittently press the corresponding button. You may have to change your location if beep is still not heard and continue to intermittently press the corresponding button. NOTE: The Remote Transmitter is portable, it can be removed from the provided Tabletop Cradle and carried with you to locate devices attached to a fob. PARTS 1. Remote Transmitter 2. Transmitter Cradle 3. Key Fobs (2) 4. CR2032 Button Cell Batteries (4) (Not pictured) 2 1 3 3 INSTALLING BATTERIES REMOTE TRANSMITTER Requires 2 AAA batteries (not included). 1. Grasp the back cover of the transmitter and firmly slide it down to access the battery compartment inside. 2. Insert 2 “AAA” 1.5V batteries into the transmitter, aligning the polarity (+/-) of the batteries to match the labels provided inside the battery compartment. 3. Reattach the back cover of the transmitter. Start by positioning the cover on the device with the top edge aligned at the level of the top-most screws, and then firmly push the entire cover up. KEEP THIS PACKAGING FOR REFERENCE AS IT CONTAINS IMPORTANT INFORMATION. BATTERY WARNING: • Do not mix old and new batteries. • Do not mix alkaline, standard (carbon-zinc), or rechargeable batteries. • Ensure all batteries are installed correctly according to polarity (+ and -). Do not short-circuit the supply terminal. • Remove batteries when not in use. Recycle or dispose of exhausted batteries according to federal, state, and local laws. Do NOT dispose of batteries in household trash or incinerate. • Only use manufacturer specified battery(ies), charger(s) and/or adapter, if applicable, specified by the manufacturer. • Always use, replace, and recharge (if applicable) batteries under adult supervision. • Non rechargeable batteries are not to be recharged. • Do not force discharge, recharge, disassemble, heat above 70 °C …
Text truncated - open the document above for the full version.
One Distribution Center Circle, Suite 1 Littleton, MA 01460 Tel: +1 978 486 8880 Email: certification@ bureauveritas.com Page 1 of 2 SCS-F235 Attestation of Covered List Rev 1.0 Attestation of Covered List Reason for Amendment Revision # Approved Date To Initial Release 1.0 Jul-01-2024 Guangdong Longde S&T Technology Co., Ltd. Letter of Attestation of Covered List Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date:08-05-2024 FCC ID: 2BGZG2024A11 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing [Guangdong Longde S&T Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing [Guangdong Longde S&T Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] identified on the Covered List as an entity producing “covered” equipment. Cover List Link: (https://www.fcc.gov/supplychain/coveredlist) Applicant: Guangdong Longde S&T Technology Co., Ltd. Address: No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China Contact Person: Teresa Xia Tel.: 0760-23820470 Email: [email protected] Sincerely,
One Distribution Center Circle, Suite #1 Littleton, MA 01460 Tel: +1 978 486 8880 Email: [email protected] Website: https://www.cps.bureauveritas.com/ Page 1 of 2 SCS-F236 Attestation of US Agent for Service Process Rev 1.0 Attestation of US Agent for Service Process Reason for Amendment Revision # Approved Date To Initial Release 1.0 Jul-01-2024 Guangdong Longde S&T Technology CO., LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA FCC ID: 2BGZG2024A11 Date of Filing to TCB: 08-01-2024 Ref: Attestation Statements Part 2.911(d)(7) Filing Guangdong Longde S&T Technology CO., LTD (“the applicant”) certifies that, as of the date of the filing of the application, [FCC US Agent, LLC] is our designated U.S. agent for service of process for the above referenced FCC ID. Guangdong Longde S&T Technology CO., LTD accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment and will notify the TCB/FCC in a timely manner if the US Processing Agent changes. [FCC US Agent, LLC] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Tel.: 708-571-3148 Email: [email protected] Sincerely, (Applicant printed name) Teresa Xia (Applicant signature) (US Local Agent printed name) Tim Payne (US Local Agent signature)
One Distribution Center Circle, Suite 1 Littleton, MA 01460 Tel: +1 978 486 8880 Email: [email protected] Website: https://www.cps.bureauveritas.com/ SCS-F019: Confidentiality Request Letter Page 1 of 2 Rev 9.0 Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 Updated References and Contact Info 6.0 7.0 Aug-30-2020 Updated BV Company Address 7.0 8.0 Nov-28-2023 FCC - Added SDR Software/Security Information, replaced word permanent with Long-Term ISED – added SDR Software and Security Info 8.0 9.0 May-15-2024 Guangdong Longde S&T Technology Co., Ltd. SCS-F019: Confidentiality Request Letter Page 2 of 2 Rev 9.0 (2024.8.1) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 Cc: Bureau Veritas Consumer Products Services Inc. One Distribution Center Circle, Suite 1 Littleton, MA 01460 Subject: Confidentiality Request for FCC ID: 2BGZG2024A11 Pursuant to CFR 47 sections 0.457 and 0.459, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application be held confidential: Type of Confidentiality Requested Exhibit Short Term Long Term Block Diagram Short Term External Photos Short Term Long Term *** Internal Photos Short Term Long Term Operational Description/Theory of Operation Short Term Long Term Parts List Short Term Long Term Tune-Up Procedure Short Term Long Term Schematics Short Term Test Setup Photos Short Term Long Term *** User’s Manual Long Term ** SDR Software/Security Information **Automatically held Long Term Confidential *** Long Term confidentiality may be requested in accordance with FCC KDB 726920 The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: To avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 days; or for a specified date of not to exceed 180 days from the Grant Date The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name: Teresa Xia Title :Sales Manager Contact information / address : No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China
Guangdong Longde S&T Technology Co., Ltd. Declaration of Identical Product Hereby, Name of manufacturer: Guangdong Longde S&T Technology Co., Ltd. Address: No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China City: Zhongshan Country: China declares that: Product description: Auto Keyfinder Type designation(s): 1014884, 101XXXX (where XXXX can be digits 0000-9999 which represent different customers) Trademark: SHARPER IMAGE Family name is technically identical to: Product description: Auto Keyfinder Type designation: 1010308 Trademark: SHARPER IMAGE Certificate number (if applicable) They are identical with the test model 1010308 except the color of the appearance and model number for trading purpose. Date: 2024.8.1 City: Zhongshan Name: Teresa Xia Signature
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version A Reference No.:2406WDG0120 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version A Reference No.:2406WDG0120 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version A Reference No.:2406WDG0120
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version A Reference No.: 2406WDG0120 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version A Reference No.: 2406WDG0120 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version A Reference No.: 2406WDG0120 TX ANT
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version A Test Report No.: FM2406WDG0120 RF EXPOSURE REPORT Applicant Guangdong Longde S&T Technology Co., Ltd. Address No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China Manufacturer or Supplier Guangdong Longde S&T Technology Co., Ltd. Address No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China Product Auto Keyfinder Brand Name SHARPER IMAGE Model 1010308 Additional Model & Model Difference 1014884, 101XXXX (where XXXX can be digits 0000-9999 which represent different customers), see item 1 Date of tests Jun. 14, 2024 ~ Jun. 27, 2024 FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Loren Luo Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Aug. 01, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version A Test Report No.: FM2406WDG0120 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE DEFINE ................................................................................. 5 3. CLASSIFICATION ........................................................................................... 5 4. SAR TEST EXCLUSION THRESHOLDS ........................................................ 6 Test Report No.: FM2406WDG0120 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2406WDG0120 Original release Aug. 01, 2024 Test Report No.: FM2406WDG0120 1. CERTIFICATION FCC ID: 2BGZG2024A11 PRODUCT: Auto Keyfinder BRAND NAME: SHARPER IMAGE MODEL NO.: 1010308 ADDITIONAL NO.: 1014884, 101XXXX (where XXXX can be digits 0000-9999 which represent different customers) APPLICANT: Guangdong Longde S&T Technology Co., Ltd. STANDARDS: FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 Note: Additional models (see above table) are identical with the test model 1010308 except the color of the appearance and model number for trading purpose. Test Report No.: FM2406WDG0120 2. RF EXPOSURE DEFINE The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where ➢ f(GHz) is the RF channel transmit frequency in GHz ➢ Power and distance are rounded to the nearest mW and mm before calculation ➢ The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SA…
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 27 Report Version 1 Test Report No.: RF2406WDG0120 TEST REPORT Applicant Guangdong Longde S&T Technology Co., Ltd. Address No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China Manufacturer or Supplier Guangdong Longde S&T Technology Co., Ltd. Address No.33 Middle Industrial, Avenue, Xiaolan Town, Zhongshan City, Guangdong Province, China Product Auto Keyfinder Brand Name SHARPER IMAGE Model 1010308 Additional Model & Model Difference 1014884, 101XXXX (where XXXX can be digits 0000-9999 which represent different customers), see item 3.1 Date of tests Jun. 14, 2024 ~ Jun. 27, 2024 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.231 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Luo Loren Projet Engineer / EMC Department Approved by Glyn He Supervisor / EMC Department Date: Aug. 01, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 27 Report Version 1 Test Report No.: RF2406WDG0120 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................................ 4 1 SUMMARY OF TEST RESULTS ....................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ................................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................... 6 3.2 DESCRIPTION OF TEST MODES ................................................................................................. 7 3.3 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ................................................. 7 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ................................................................ 9 3.5 DESCRIPTION OF SUPPORT UNITS ........................................................................................... 9 3.6 CONFIGURATION OF SYSTEM UNDER TEST ............................................................................ 9 4. TEST TYPES AND RESULTS ......................................................................................................... 10 4.1 RADIATED EMISSION MEASUREMENT .................................................................................... 10 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ............................................................. 10 4.1.2 TEST INSTRUMENTS ............................................................................................................. 11 4.1.3 TEST PROCEDURES ............................................................................................................. 12 4.1.4 TEST SETUP ........................................................................................................................... 13 4.1.5 DEVIATION FROM TEST STANDARD .................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS ............................................................................................ 14 4.1.7 TEST RESULTS ...................................................................................................................... 15 4.2 20DB BANDWIDTH MEASUREMENT ........................................................................................ 20 4.2.1 LIMITS OF 20DB BANDWIDTH MEASUREMENT ............................................................. 20 4.2.2 TEST INSTRUMENTS ........................................................................................................ 20 4.2.3 TEST PROCEDURE ................…
Text truncated - open the document above for the full version.
Length:54.6mm Antenna Type: ASK Antenna Gain:0dBi Antenna operates frequency range: 315MHz Only radiated measurements are used to show compliance with FCC limits for fundamental and spurious emissions.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 2 Report Version A Reference No.: 2406WDG0120 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 2 Report Version A Reference No.: 2406WDG0120 Frequency Range< Above 1GHz >
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |