Technical Specifications
| # | Rule Parts | Frequency Range | Power Output |
|---|
| 2 | 15E | 5.75 GHz - 5.83 GHz | 103.04 mW |
Grant NotesOutput power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 0.73 W/kg.The highest simultaneous reported SAR value for body-worn accessory is 1.43W/kg.
The device contains 20MHz, 40MHz and 80MHz bandwidth.
Device is a 2x2 MIMO as described in the filing.