Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Fangpai Electronic Products Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 27, 2024 FCC ID: 2BH53-FPQL01 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing Shenzhen Fangpai Electronic Products Co., Ltd. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing Shenzhen Fangpai Electronic Products Co., Ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Applicant: Shenzhen Fangpai Electronic Products Co., Ltd. Address: 502, Building C, Hongwan Business Center, Xixiang Street, Bao'an District, Shenzhen City, China Contact Person: Fanyi Tel.: +86-14775573408 Email: [email protected] Sincerely, Signature:
Shenzhen Fangpai Electronic Products Co., Ltd. U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: September 27 2024 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BH53-FPQL01 Shenzhen Fangpai Electronic Products Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, CLF Import and Export Limited (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. CLF Import and Export Limited ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: CLF Import and Export Limited FRN: 0033489683 Address: 1312 17th Street #692, Denver, CO 80202, United States Signature: Contact Person: David Chen Tel: +1 949 254 2565 Email: [email protected] Applicant Company Name: Shenzhen Fangpai Electronic Products Co., Ltd. FRN: 0035779131 Address: 502, Building C, Hongwan Business Center, Xixiang Street, Bao'an District, Shenzhen City, China Signature: Contact Person: Fanyi Tel: +86-14775573408 Email: [email protected]
CCUT Testing & Certification Report No: SSP24090076-2A Antenna Test Report Page 1 of 5 Antenna Test Report Report No. : SSP24090076-2A Manufacturer : Shenzhen Fangpai Electronic Products Co., Ltd. Product Name : 2.4GHz Antenna Model Name : FPQL01 Test Standard : IEEE 149-1979 Tested Date : 2024-07-15 Issued Date : 2024-07-16 Tested By : William Liu(Engineer) Approved By : Lahm Peng (Manager) Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.ccuttest.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. CCUT Testing & Certification Report No: SSP24070311-2A Antenna Test Report Page 2 of 5 1. General Inf ormation 1.1 Product Information Manufacturer: Shenzhen Fangpai Electronic Products Co., Ltd. Address of Manufacturer: 502, Building C, Hongwan Business Center, Xixiang Street, Bao'an District, Shenzhen City, China Product Name: 2.4GHz Antenna Model Name: FPQL01 Frequency Range: 2402MHz - 2480MHz Type of Antenna: PCB Antenna Antenna Gain: 0dBi (Max.) Impedance: 50 ohm Antenna View: Length * Width (1.2mm * 3mm) 1.2 Test Facilities Laboratory Name: Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China All measurement facilities used to collect the measurement data are located at 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China. CCUT Testing & Certification Report No: SSP24070311-2A Antenna Test Report Page 3 of 5 1.3 List of Measurement Instruments Description Manuf acturer Model Serial Number Cal. Date Due. Date Horn Antenna SCHWARZBECK BBHA 9120D 02553 2023-08-05 2024-08-04 Spectrum Analyzer KEYSIGHT N9020A MY48030972 2023-07-31 2024-07-30 Amplifier Agilent 8449B 3008A01520 2023-07-31 2024-07-30 Vector Network Analyzer Agilent E5071B MY42404001 2023-07-31 2024-07-30 1.4 Measurement Uncertainty Parameter Conditions Uncertainty Radiated Emissions Power 100MHz ~ 6GHz ±3.38 dB 1.5 Test Methodology All measurements contained in this report were conducted with standards IEEE 149-1979 for IEEE Standard Test Procedures for Antennas. 1.6 Test Setup CCUT Testing & Certification Report No: SSP24070311-2A Antenna Test Report Page 4 of 5 2. OTA Test 2.1 Gain Frequency Peak Gain (dBi) Polarity 2402MHz 0 Horizontal 2402MHz -0.37 Vertical 2442MHz -0.58 Horizontal 2442MHz -1.09 Vertical 2480MHz -1.52 Horizontal 2480MHz -1.71 Vertical CCUT Testing & Certification Report No: SSP24070311-2A Antenna Test Report Page 5 of 5 2.2 Radiation Pattern View ***** END OF REPORT *****
Shenzhen Fangpai Electronic Products Co., Ltd. Date:September 27, 2024 Product Model Number: FPQL01, FPQL02 FCC ID:2BH53-FPQL01 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: Testing Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Fanyi Contact Listed on FCC Wesbite Title: Manager Email: [email protected] Telephone: +86-14775573408 On behalf of: Shenzhen Fangpai Electronic Products Co., Ltd.
Shenzhen Fangpai Electronic Products Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 27, 2024 Subject; Request for Confidentiality FCC ID: 2BH53-FPQL01 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Fanyi Title: Manager
Shenzhen Fangpai Electronic Products Co., Ltd. Model Difference Statement Dear Sir/Madam, Added models FPQL02 basis of the original product FPQL01. The color of appearance and model name of series models listed are different from the main model, but the circuit and the electronic construction are the same, declared by the manufacturer. Sincerely, Name: Fanyi Title: Manager Company name: Shenzhen Fangpai Electronic Products Co., Ltd. Address: 502, Building C, Hongwan Business Center, Xixiang Street, Bao'an District, Shenzhen City, China
Report No: SSP24090076-1E FCC ID: 2BH53-FPQL01 Annex of Test Report Annex A. EUT External Photos EUT View 1 EUT View 2 Report No: SSP24090076-1E FCC ID: 2BH53-FPQL01 Annex of Test Report EUT View 3 EUT View 4 Report No: SSP24090076-1E FCC ID: 2BH53-FPQL01 Annex of Test Report EUT View 5 EUT View 6 Report No: SSP24090076-1E FCC ID: 2BH53-FPQL01 Annex of Test Report EUT View 7
Report No: SSP24090076-1E FCC ID: 2BH53-FPQL01 Annex of Test Report Annex D. Label and Inf ormation FCC Label Sample FCC Label Specifications Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Where the EUT is constructed in two or more sections connected by wires and marketed together, the above statement is required to be affixed only to the main control unit. When the EUT is so small or for such use that it is not practicable to place the statement on it, the above information shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. FCC Label Location
FCC ID: 2BH53-FPQL01 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation BLE mode Mode Output power to antenna (dBm) Tune-up Power(dBm) Max Tune-up Power(dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 2480 -2.14 -2(±1) -1 0.79 0.0002 1.0 PASS Remark: antenna gain=0dBi
CCUT Testing & Certification Report No: SSP24090076-1E FCC Test Report Page 1 of 33 FCC TEST REPORT FCC ID: 2BH53-FPQL01 Report No. : SSP24090076-1E Applicant : Shenzhen Fangpai Electronic Products Co., Ltd. Product Name : Quantum lamp Model Name : FPQL01 Test Standard : FCC Part 15.247 Date of Issue : 2024-09-14 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.ccuttest.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. CCUT Testing & Certification Report No: SSP24090076-1E FCC Test Report Page 2 of 33 Test Report Basic Information Applicant..................................: Shenzhen Fangpai Electronic Products Co., Ltd. Address of Applicant...............: 502, Building C, Hongwan Business Center, Xixiang Street, Bao'an District, Shenzhen City, China Manufacturer..........................: Shenzhen Fangpai Electronic Products Co., Ltd. Address of Manufacturer........: 502, Building C, Hongwan Business Center, Xixiang Street, Bao'an District, Shenzhen City, China Product Name.........................: Quantum lamp Brand Name.............................: - Main Model..............................: FPQL01 Series Models..........................: FPQL02 Test Standard..........................: FCC Part 15 Subpart C KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.4-2014 ANSI C63.10-2013 Date of Test .............................: 2024-09-09 to 2024-09-12 Test Result...............................: PASS Tested By ................................: (Walker Wu) Reviewed By............................: (Lieber Ouyang) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. CCUT Testing & Certification Report No: SSP24090076-1E FCC Test Report Page 3 of 33 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Compliance Standards ...........................................................................................................................................7 1.4 Test Facilities ........................................................................................................................................................7 1.5 List of Measurement Instruments ..........................................................................................................................8 1.6 Measurement Uncertainty .....................................................................................................................................9 2. Summary of Test Results ........................................................................................................................................... 10 3. Antenna Requirement ............................................................................................................................................... 11 3.1 Standard and Limit.............................................................................................................................................. 11 3.2 Test Result .......................................................................................................................................................... 11 4. Conducted Emissions ................................................................................................................................................ 12 4.1 Standard and Limit.............................................................................................................................................. 12 4.2 Test Procedure.................................................................................................................................................... 12 4.3 Test Data and Results .......................................................................................................................................... 13 5. Radiated Emissions ................................................................................................................................................... 16 5.1 Standard and Limit.............................................................................................................................................. 16 5.2 Test Procedure.................................................................................................................................................... 16 5.3 Test Data and Results .......................................................................................................................................... 18 6. Band-edge Emissions(Radiated) ............................................................................................................................... 22 6.1 Standard and Limit.............................................................................................................................................. 22 6.2 Test Procedure.................................................................................................................................................... 22 6.3 Test Data and Results ............................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |

Vase Lamp
Equipment Class
DTS - Digital Transmission System