FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.
Shenzhen STARTRC Technology Co. Ltd. No.401,Block 4,Zhonghaixin Industrial Park, No.2,Shengbao Road,Nanwan,Longgang,Shenzhen China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-8-8 To whom it may concern: We, Shenzhen STARTRC Technology Co. Ltd., hereby certify that the equipment for which authorization is sought (FCC ID: 2BH6A-1139167) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Lin Jiang Manager Shenzhen STARTRC Technology Co. Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
Shenzhen STARTRC Technology Co. Ltd. No.401, Block 4, Zhonghaixin Industrial Park, No.2, Shengbao Road, Nanwan, Longgang, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024/08/05 U.S. Agent Designation Shenzhen STARTRC Technology Co. Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BH6A-1139167): Name and company of U.S. agent: GSS SERVICE INC Physical U.S. address of agent: 6547 N Academy Blvd #2266 Colorado Springs COLORADO 80918 United States FRN of U.S. agent: 0033402082 Email address of U.S. agent: [email protected] GSS SERVICE INC acknowledges their obligation to accept service of process on behalf of Shenzhen STARTRC Technology Co. Ltd. Shenzhen STARTRC Technology Co. Ltd. with the FRN [0035779727] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Lin Jiang Manager Shenzhen STARTRC Technology Co. Ltd. Signature Michoux Logan PM GSS SERVICE INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
Shenzhen STARTRC Technology Co. Ltd. Add: No.401,Block 4,Zhonghaixin Industrial Park, No.2,Shengbao Road,Nanwan,Longgang,Shenzhen China Date: 2024-8-8 FCC ID: 2BH6A-1139167 Dear Sir/Madam, We, Shenzhen STARTRC Technology Co. Ltd. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: DRONE UNIVERSAL ALARM SYSTEM Model no.: 1139167, 1145571 Sincerely, Name/Title: Lin Jiang/Manager Company: Shenzhen STARTRC Technology Co. Ltd. Address: No.401,Block 4,Zhonghaixin Industrial Park, No.2,Shengbao Road,Nanwan,Longgang,Shenzhen China Phone: 18824666862 Fax: N/A E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-8-8> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BH6A-1139167 1139167 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Lin Jiang/Manager Company: Shenzhen STARTRC Technology Co. Ltd. Address: No.401,Block 4,Zhonghaixin Industrial Park, No.2,Shengbao Road,Nanwan,Longgang,Shenzhen China Phone: 18824666862 Fax: N/A E-Mail: [email protected]
Shenzhen STARTRC Technology Co. Ltd. No.401,Block 4,Zhonghaixin Industrial Park, No.2,Shengbao Road,Nanwan,Longgang,Shenzhen China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-8-8 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BH6A-1139167 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Lin Jiang/Manager Company: Shenzhen STARTRC Technology Co. Ltd. Address: No.401,Block 4,Zhonghaixin Industrial Park, No.2,Shengbao Road,Nanwan,Longgang,Shenzhen China Phone: 18824666862 Fax: N/A E-Mail: [email protected]
FCC ID: 2BH6A-1139167 External Photos of the EUT FCC ID: 2BH6A-1139167 FCC ID: 2BH6A-1139167
Label and Location Size: L: 2.0cm*W: 1.5cm Label and Location FCC ID : 2BH6A-1139167
FCC ID: 2BH6A-1139167 Internal Photos of the EUT FCC ID: 2BH6A-1139167 ANT
RF Exposure evaluation FCC ID: 2BH6A-1139167 1.1. Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure requirement KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 1.2. Requirement According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 “ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 1.3. Manufacturing tolerance GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) -2.0 -2.0 -1.0 Tolerance ±(dB) 1.0 1.0 1.0 Page 2 of 2 2. E v a l u a t i o n R e s u l t Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power (including tune-up tolerance) SAR Test Exclusion Threshold SAR Test Exclusion dBm mW BLE 2.450 5 0.0 1.000 0.3130<3.0 Yes 3. C o n c l u s i o n The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06 .....................End of Report.........................
Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL INFORMATION 1.1 Test Environment Condition Ambient Temperature 19 to 25 °C Ambient Relative 45 to 55 % Humidity Ambient Pressure N/A (Not applicable) 1.2 Announce (1) The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report. (2) The test report is invalid if there is any evidence and/or falsification. (3) The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. (4) This document may not be altered or revised in any way unless done so and all revisions are duly noted in the revisions section. (5) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PRODUCT INFORMATION 2.1 Applicant Applicant Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Contact Person Tony Telephone Number +86 0755-82031775;25332530 Fax Number +86 0755-82713604 E-mail Address [email protected] 2.2 Manufacturer Manufacturer Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Shenzhen City, Guangdong Province, China Contact Person N/A Telephone Number N/A Fax Number N/A E-mail Address N/A 2.3 General Description for Equipment under Test (EUT) EUT Type Bluetooth Antenna Model Name PCB Antenna Antenna Type PCB Antenna Hardware Version N/A Serial Number N/A Dimensions N/A 2.4 Technical Information Frequency Range 2400MHz~ 2500MHz Test Frequencies 2402MHz, 2441MHz, 2480MHz Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 IEEE149-1979 IEEE Standard Test Procedures for Antennas 3.2 Test Verdict Report Section Description Remark ANNEX A.1 Gain And Efficiency -- ANNEX B Radiation Pattern -- 3.3 Test Uncertainty The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Item Uncertainty VSWR(S11) 0.4 Gain -0.21dBi Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL TEST CONFIGURATIONS 4.1 Test Condition Environment Parameter Selected Values During Tests Temperature Voltage Relative Humidity Normal Temperature, Normal Voltage 25°C N/A 51% (NTNV) 4.2 Test Equipment List Description Manufacturer Model Serial No. Cal. Date Cal. Due Vector Network Agilent E5071C MY46103472 2014.09.07 2015.09.06 Analyzer 5*5*5 Full Anechoic SATIMO 5*5*5 N/A 2014.09.05 2015.09.04 Chamber SG24 Multi-probe Antenna Measurement SATIMO SG24-L 1101855-0001 2014.10.25 2015.10.24 System 4.3 Test Setup Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX A TEST RESULTS A.1 Gain and Efficiency Frequency Gain (dBi) Efficiency (%) 2402MHz -0.08 0.99 2441MHz -0.21 1.06 2480MHz -0.18 1.12 ANNEX B RADIATION PATTERN 3DPattern 2402MHZ Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China 2480MHZ 1D Radiation Pattern PHI =0 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PHI =90 THETA = 90 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX C TEST SETUP PHOTO ANNEX D EUT PHOTO Antenna shape
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID. ............................................ : CTA24072301401 2BH6A-1139167 Compiled by ( position+printed name+signature) .. : File administrators Jinghua Xiao Supervised by ( position+printed name+signature) .. : Project Engineer Xudong Zhang Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Jul. 30, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Shenzhen STARTRC Technology Co. Ltd. Address ............................................ : No.401, Block 4, Zhonghaixin Industrial Park, No.2, Shengbao Road, Nanwan, Longgang, Shenzhen, China Test specification ...........................: Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description...................: DRONE UNIVERSAL ALARM SYSTEM Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen STARTRC Technology Co. Ltd. Model/Type reference....................... : 1139167 Listed Models .................................. : 1145571 Modulation ....................................... : GFSK Frequency .......................................... From 2402MHz to 2480MHz Ratings ............................................. : DC 3.7V From battery and DC 5.0V From external circuit Result................................................ : PASS Report No.: CTA24072301401 Page 2 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : DRONE UNIVERSAL ALARM SYSTEM Model /Type : 1139167 Listed Models : 1145571 Applicant : Shenzhen STARTRC Technology Co. Ltd. Address : No.401, Block 4, Zhonghaixin Industrial Park, No.2, Shengbao Road, Nanwan, Longgang, Shenzhen, China Manufacturer : Shenzhen STARTRC Technology Co. Ltd. Address : No.401, Block 4, Zhonghaixin Industrial Park, No.2, Shengbao Road, Nanwan, Longgang, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24072301401 Page 3 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description* 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 6 2.6 Block Diagram of Test Setup 6 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 11 4.1 AC Power Conducted Emission 11 4.2 Radiated Emissions and Band Edge 14 4.3 Maximum Peak Output Power 21 4.4 Power Spectral Density 22 4.5 6dB Bandwidth 24 4.6 Out-of-band Emissions 26 4.7 Antenna Requirement 30 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 31 6 P H O T O S O F T H E E U T ........................................................... 32 Report No.: CTA24072301401 Page 4 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 V05r02: Guidance for Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating Under §15.247 Report No.: CTA24072301401 Page 5 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:cta…
Text truncated - open the document above for the full version.
FCC ID: 2BH6A-1139167 Test Setup Photos of the EUT
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |

MINI Wireless Controller
Equipment Class
DTS - Digital Transmission System