2BH88AILENS-ONEAiLens

THINKAR PTE. LTD.
AiLens - FCC ID 2BH88AILENS-ONE - THINKAR PTE. LTD.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 05, 2024
Application Purpose
Original Equipment
Date of Application
Sep 05, 2024
Equipment Note
AiLens
Frequency Range
2402.00000000 - 2480.00000000
Company
THINKAR PTE. LTD.
Country
Singapore

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AiLens Installation of Refractive Frame Note:Requires in-store prescription lenses fitting. 1.Manually pull out the decorative piece at the indicated angle and remove it. 2.Align the integrated lens with the installation hole and press firmly into the frame. � Function Indicators Microphone Charging Indicator Light Bottom View Top View Power Button Charging Port SpeakerSpeaker Microphone Vent HoleVent Hole Packing List After unpacking the box,you shall see the following items: -AiLens -2-Pin Magnetic Charging Cable -Nose Pads -Carrying Glasses Case -Cleaning Cloth -User Manual -Refractive Frame � 1 2 Temple Adjustment - Adaptive range: 20 degrees. - Can be adjusted according to different head sizes. 10° 10° Touchbar - Single click: Confirm - Double click: Return - Swipe: Switch options Power Button � Single clickReturn/Screen On Double clickScreen Off Long press 1sWake up AI voice Long press 3sPower On/Off Long press 10sForce restart LED Indicator Nose Pad Adjustment - The nose pad bracket is made of memory metal. - The height of the nose pad can be adjusted by replacing the nose pad or adjusting the nose pad slot as shown. - Adjust the nose pad width by gently pressing it to a comfortable position. Charging Indicator Light Status Charging (Orange light on) Fully Charged (Green light on) Not Charging (Light off) Usage Notes All rights reserved by ThinkAR. This manual is for reference purposes only and does not constitute any form of commitment. The actual product (including, but not limited to, color, weight, size, screen display, etc.) may vary. Thank you for purchasing this product. The information in this manual may include safety notices as well as relevant rights and responsibilities. ThinkAR reserves the right to update this manual on our official website. For the latest product information and manual, please visit the product’s official page on the website. By using this product, you and your guest users acknowledge that you have carefully read this manual, understand its contents, and agree to abide by its terms and conditions. You and your guest users accept full responsibility for your actions and their consequences while using this product. The product should be used in a normal and reasonable manner. You and your guest users agree to use this product for appropriate purposes only, in compliance with all applicable local laws, regulations, rules, and all terms, precautions, practices, policies, and guidelines set or to be set for this product. ThinkAR shall not be held liable for any obligations or responsibilities arising from your or your guest users' access to or use of third-party content, any content or features contained within third-party content, or any loss of life, property, or other damages caused by improper or non-compliant use of this product, or by the connection to or use of any third-party tools or apps with this product. You and your guest users are responsible for complying with all recommendations and guidelines for using third-party software to avoid potential dangers. Your obligations and rights while using or accessing third-party content, apps, and devices are governed by the agreements between you and the third party. Legal Statement � Specification Product NameAiLens Battery TypeRechargeable Lithium-ion Battery Battery Capacity175mAh Charging Input5V1A -Due to incomplete visual development, minors under 18 should not use this product. User Group Notice Safety & Warranty Before using this product, users must thoroughly read the manual and familiarize themselves with the product's features and risks. Unusual, unsafe, or irresponsible use of this product may result in injury to oneself or others, or damage to the product or other property. By using the product, you agree to waive all rights and claims against ThinkAR and its affiliates. - Users with sensitive skin that will come into contact with the product should not use this product. Some people may be allergic to materials such as plastic, leather, and fibers. Prolonged contact may lead to redness and inflammation. Discontinue the use of the product and consult a doctor if you experience similar symptoms. - This product does not support adjustments for myopia. If you have myopia, hyperopia, or astigmatism, you may experience unclear screen visibility. It is recommended to use this product with refractive clip lenses or contact lenses for optimal viewing. For the use of refractive clip lenses, please consult your local optometrist. Before wearing this product, carefully inspect for any damage, such as cracks or gaps in the frame, lenses, or nose pads. Do not use the product if any damage is found at any time. People with a history of epilepsy, high blood pressure, heart disease, acrophobia, severe myopia, mental illness, pregnant women, or those unsuitable for 3D immersive and stimulating experiences should not use this product. If you experience dizziness, eye fatigue, visual abnormalities (such as double vision, distorted vision, eye discomfort, or pain) while using the product, discontinue use immediately and consult with your doctor. To avoid radio wave interference, keep this product at least 15 centimeters away from implanted medical devices or personal medical devices (such as pacemakers, cochlear implants, and hearing aids). Consult the device manufacturer regarding usage restrictions. � -Do not use this product in environments with unknown external factors or during nighttime driving, as it may pose additional dangers and Safety Information Before using the product, ensure the safety of the environment to avoid serious injury or death. Ensure there are no obstacles, furniture, pits, slippery surfaces, people, or pets in the path while using this product. Stay away from stairs, balconies, open doors, windows, and open flames. Note that using this product outdoors may introduce other uncontrollable and unpredictable dangers such as traffic, pedestrians, noise, or changes in lighting that may af…

Text truncated - open the document above for the full version.

Attestation Statements

UNITED STATES DESIGNATED AGENT LETTER Date: 16-08-2024 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Applicant U.S. designated agent Company Name: THINKAR PTE. LTD. Company Name: United Consulting Technology Services Co., Ltd. Grantee Code: 2BH88 FRN 0033495714 Contact Name: Joe Ye Contact Name: David Wu Address: 346C KING GEORGE'S AVENUE KING GEORGE'S BUILDING Address: 17800 CASTLETON ST STE 665 CITY OF INDUSTRY CA 91748 United States City/Province/Zip: SINGAPORE (208577) City/Province/Zip: Telephone: (886) 935650621Telephone: (626 ) 2 17- 4022 Fax: (886 ) 2 87723233Fax: United Consulting Technology Services Co., Ltd. Email: [email protected] Email: [email protected] Applicable Equipment: FCC ID: 2BH88AILENS-ONE ATTN: Director of Certification: We, THINKAR PTE. LTD. and United Consulting Technology Services Co., Ltd. understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e-mail of the designated agent listed above. We, THINKAR PTE. LTD. and United Consulting Technology Services Co., Ltd. acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Applicant U.S. designated agent Name (Printed): Joe Ye Name (Printed): David Wu Title: Director Title: General Manager Signature: Signature:

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.1 Jan 17, 2024 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name THINKAR PTE. LTD. Address 346C KING GEORGE'S AVENUE KING GEORGE'S BUILDING SINGAPORE (208577) FRN 0035797455 Grantee Code 2BH88 FCC ID 2BH88AILENS-ONE Authorized Contact Name Joe Ye Contact Email [email protected] Contact Phone +886935650621 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List THINKAR PTE. LTD. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. THINKAR PTE. LTD. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. Applicant Signature: Date: 2024-08-19 Print Name: Joe Ye Title: Director *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Cover Letter(s)

THINKAR PTE. LTD. Date: 16-08-2024 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2BH88AILENS-ONE To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with THINKAR PTE. LTD. This authorization is valid until further written notice from the applicant. Print Name: Joe Ye Title: Director Signature: On behalf of Company: THINKAR PTE. LTD. Telephone: +886935650621 E-mail: [email protected]

Cover Letter(s)

THINKAR PTE. LTD. TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: Confidentiality Request regarding application for FCC ID: 2BH88AILENS-ONE LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby requests confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Tune up procedure The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY(Remark:如下资料需要短期保密请选择天数0,45,90或者180天,注意短期保密期间产品不能在市场上售卖或者能查 到产品已经发布的信息,) Additionally, the applicant requests the following documents be held confidential until the device is marketed or 0 days from the grant date, whichever is less. If the device is marketed within 0 days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. Delete any document that is NOT included in your application External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Joe Ye Title: Director Signature: On behalf of Company: THINKAR PTE. LTD. Telephone: +886935650621 E-mail: [email protected]

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 1 of 4 Internal Photos for SZCR2407002901AT FCC ID: 2BH88AILENS-ONE SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 2 of 4 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 4 of 4 Antenna location: - End of the Appendix -

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01-A03 Rev. A/0 Aug 16,2024 Report No.: SZCR240700290104 Page: 1 of 2 Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 2450 MHz Head Date: 2024-08-27Test Laboratory: SGS-SAR Lab System Performance Check 2450MHz Head D2450V2-SN 733 Communication System: D2450; Frequency: 2450.000 Medium: HSL. Medium parameters used: f= 2450.000 MHz; σ= 1.80 S/m; ε r = 40.2 DASY8 Configuration: - Probe: EX3DV4 - SN7838; ConvF(7.4, 7.32, 7.42); Calibrated: 2023-09-11 - Sensor-Surface: 1.4 mm - Electronics: DAE4ip Sn1803; Calibrated: 2024-08-08 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2146 - Measurement Software: cDASY8 V16.2.4.2524 Area Scan (96.0 mm x 120.0 mm): Measurement Grid: 12.0 mm x 12.0 mm SAR (1g) = 12.9 W/kg; SAR (10g) = 5.91 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 5.0 mm Power Drift = -0.03 dB SAR (1g) = 13.3 W/kg; SAR (10g) = 6.26 W/kg;

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01-A04 Rev. A/0 Aug 16,2024 Report No.: SZCR240700290104 Page: 1 of 2 Appendix B Detailed Test Results BT for Head Date: 2024-08-27Test Laboratory: SGS-SAR Lab Bluetooth Ble 1M 39CH Left side 0mm Communication System: ISM 2.4 GHz Band; Frequency: 2480.000 Medium: Head Simulating Liquid. Medium parameters used: f= 2480.000 MHz; σ= 1.82 S/m; ε r = 40.1 DASY8 Configuration: - Probe: EX3DV4 - SN7838; ConvF(7.4, 7.32, 7.42); Calibrated: 2023-09-11 - Sensor-Surface: 1.4 mm - Electronics: DAE4ip Sn1803; Calibrated: 2024-08-08 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2146 - Measurement Software: cDASY8 V16.2.4.2524 Area Scan (96.0 mm x 168.0 mm): Measurement Grid: 12.0 mm x 12.0 mm SAR (1g) = 0.130 W/kg; SAR (10g) = 0.053 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 5.0 mm Power Drift = -0.03 dB SAR (1g) = 0.154 W/kg; SAR (10g) = 0.060 W/kg;

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01-A01 Rev. A/1 Aug 16,2024 Report No.: SZCR240700290104 Page: 1 of 34 Appendix C Calibration certificate 1. Dipole D2450V2-SN 733 2.DAE DAE4ip-S N 1803 3. Probe EX3DV4-SN 7838

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR240700290104 Page: 1 of 31 Keny Xu EMC Laboratory Manager FCC SAR TEST REPORT Application No.: SZCR2407002901AT Applicant: THINKAR PTE. LTD. Manufacturer: THINKAR PTE. LTD. EUT Description: AiLens Model No.: AiLens One FCC ID: 2BH88AILENS-ONE Standards: FCC 47CFR §2.1093 Date of Receipt: 2024-08-26 Date of Test: 2024-08-27 Date of Issue: 2024-08-30 Test Result : PASS * * In the configuration tested, the EUT detailed in this report complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR240700290104 Page: 2 of 31 Revision Record Version Description Date Remark 01 / 2024-08-30 Original Authorized for issue by: Benson Wang/Project Engineer Eric Fu / Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR240700290104 Page: 3 of 31 Test Summary Frequency Band Maximum Reported SAR1g(W/kg) Head BT 0.30 SAR Limited(W/kg) 1.6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR240700290104 Page: 4 of 31 Contents 1 General Information ..................................................................................................... 5 1.1 Details of Client ........................................................................................................ 5 1.2 Test Location ............................................................................................................ 5 1.3 Test Facility ............................................................................................................... 5 1.4 General Description of EUT .................................................................................... 6 1.5 Test Specification ..................................................................................................... 8 1.6 RF exposure limits ................................................................................................... 9 2 Laboratory Environment ........................................................................................... 10 3 SAR Measurements System Configuraion ............................................................ 11 3.1 The SAR Measurement System ........................................................................... 11 3.2 Isotropic E-field Proble EX3DV4 ........................................................................... 12 3.3 Data Acquisition Electronics (DAE) ...................................................................... 13 3.4 SAM Twin Phantom ............................................................................................... 13 3.5 ELI Phantom ........................................................................................................... 14 3.6 Device Holder for Transmitters ............................................................................. 15 3.7 Measurement Procedure ....................................................................................... 16 4 SAR measurement variability and uncertainty ..................................................... 20 4.1 SAR measurement variability................................................................................ 20 4.2 SAR measurement uncertainty ............................................................................. 20 5 Desciption of Test Position ...................................................................................... 21 5.1 The Test Position ................................................................................................... 21 6 SAR System Verificaion Procedure ........................................................................ 22 6.1 Tissue Simulate Liquid .......................................................................................... 22 6.2 SAR System Check ............................................................................................... 24 7 Test Configuration ...................................................................................................... 27 7.1 Bluetooth Test Configuration ................................................................................ 27 8 Test Result ................................................................................................................... 28 8.1 Measurement of RF Conducted Power................................................................ 28 8.2 Measurement of SAR Data ................................................................................... 29 9 Equipment list ............................................................................................................. 30 10 Calibration certificate ................................................................................................. 31 11 Photographs ................................................................................................................ 31 Appendix A: Detailed System Check Results .................................................................... 31 Appendix B: Detailed Test Results ....................................................................................... 31 Appendix C: Calibration certificate ...................................................................................... 31 Appendix D: Photographs ...................................................................................................... 31 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR240700290104 Page: 5 of 31 1 General Information 1.1 Details of Client Applicant: THINKAR PTE. LTD. Address of Applicant: 346C KING GEORGE’S AVENUE, KING GEORGE’S BUILDING, SINGAPORE 208577 Manufacturer: THINKAR PTE. LTD. Address of Manufacturer: 346C KING GEORGE’S AVENUE, KING GEORGE’S BUI…

Text truncated - open the document above for the full version.

Test Report

FreqEfficiency_dBGainEfficiency_Pcent 2400-9.27-2.1511.83 2410-8.58-1.5313.86 2420-8.1-1.2715.5 2430-7.67-1.1117.1 2440-7.14-0.9119.33 2450-6.88-1.0820.52 2460-6.67-1.3421.51 2470-6.53-1.7622.22 2480-6.49-2.0222.46 2490-6.43-2.0522.73 2500-6.44-2.1622.68 Shenzhen Sunway Communication Co., Ltd 1013, Xihuan Rd., Shajing Town, Bao'an District, Shenzhen, P.R. China, Zip 518104 Model: 3100036710

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR240700290102 Page: 1 of 98 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2407002901AT Applicant: THINKAR PTE. LTD. Address of Applicant: 346C KING GEORGE’S AVENUE, KING GEORGE’S BUILDING, SINGAPORE 208577 Manufacturer: THINKAR PTE. LTD. Address of Manufacturer: 346C KING GEORGE’S AVENUE, KING GEORGE’S BUILDING, SINGAPORE 208577 Equipment Under Test (EUT): EUT Name: AiLens Model No.: AiLens One FCC ID: 2BH88AILENS-ONE Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2024-07-25 Date of Test: 2024-07-31 to 2024-08-09 Date of Issue: 2024-08-28 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR240700290102 Page: 2 of 98 Revision Record Version Chapter Date Modifier Remark 01 2024-08-28 Original Authorized for issue by: Benson Wang/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR240700290102 Page: 3 of 98 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence N/A 47 CFR Part 15, Subpart C 15.247(a)(1),(g),(h) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 7.8.5 47 CFR Part 15, Subpart C 15.247(b)(1) Pass 20dB Bandwidth ANSI C63.10 (2013) Section 7.8.7 47 CFR Part 15, Subpart C 15.247(a)(1) Pass Carrier Frequencies Separation ANSI C63.10 (2013) Section 7.8.2 47 CFR Part 15, Subpart C 15.247a(1) Pass Hopping Channel Number ANSI C63.10 (2013) Section 7.8.3 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Dwell Time ANSI C63.10 (2013) Section 7.8.4 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 7.8.6 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 7.8.8 47 CFR Part 15, Subpart C 15.247(d) Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR240700290102 Page: 4 of 98 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Test Summary ..................................................................................................................................... 3 3 Contents ............................................................................................................................................. 4 4 General Information............................................................................................................................ 6 4.1 Details of E.U.T. ........................................................................................................................... 6 4.2 Description of Support Units ......................................................................................................... 7 4.3 Measurement Uncertainty ............................................................................................................ 7 4.4 Test Location ............................................................................................................................... 8 4.5 Test Facility .................................................................................................................................. 8 4.6 Deviation from Standards ............................................................................................................. 8 4.7 Abnormalities from Standard Conditions ....................................................................................... 8 5 Equipment List ................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ..........................................................................................12 6.1 Antenna Requirement .................................................................................................................12 6.1.1 Test Requirement: ..................................................................................................................12 6.1.2 Conclusion ..............................................................................................................................12 6.2 Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence ...............13 6.2.1 Test Requirement: ..................................................................................................................13 7 Radio Spectrum Matter Test Results ................................................................................................14 7.1 Conducted Emissions at AC Power Line (150kHz-30MHz) ..........................................................14 7.1.1 E.U.T. Operation .....................................................................................................................14 7.1.2 Test Mode Description ................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A04 Rev.A/0 Page: 1 of 3 Setup Photos for SZCR2407002901AT FCC ID: 2BH88AILENS-ONE SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A04 Rev.A/0 Page: 2 of 3 Test Setup Photo Conducted Emissions at AC Power Line (150kHz-30MHz) Radiated Spurious Emissions Below 1GHz SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A04 Rev.A/0 Page: 3 of 3 Radiated Spurious Emissions Above 1GHz - End of the Appendix -

Test Setup Photos

SGS-CSTC Standards Technical Services Co., …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Joe Ye
[email protected]+886935650621Fax: +886287723233

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]075525328629

No.1 Workshop, M-10, Middle Section Science & Tech · Shenzhen · China

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]+86 (0)755 2532 8629

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz10.80 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. SAR compliance for portable use conditions has been evaluated as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. The highest reported SAR values for head is 0.30W/kg.