FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Three Tigers Trading Co., Ltd./
  3. 2BHCY-X100

2BHCY-X100Mobile Phone

Shenzhen Three Tigers Trading Co., Ltd.
Mobile Phone - FCC ID 2BHCY-X100 - Shenzhen Three Tigers Trading Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 16, 2024
Application Purpose
Original Equipment
Date of Application
Jul 16, 2024
Equipment Note
Mobile Phone
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Three Tigers Trading Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harm full interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Specific Absorption Rate (SAR) information: This Device meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information and Statement the SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: Device has also been tested against this SAR limit. This device was tested for typical body-worn operations with the back of the device kept 10mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain an 10mm separation distance between the user's body and the back of the device. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.

Attestation Statements

Shenzhen Songya Technology Co., Ltd. 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-7-17 To whom it may concern: We, Shenzhen Songya Technology Co., Ltd. , hereby certify that the equipment for which authorization is sought (FCC ID: 2BHCY-X100) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Yuehu Chen Manager Shenzhen Songya Technology Co., Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03

Cover Letter(s)

Shenzhen Songya Technology Co., Ltd. Add: 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Date: 2024-7-17 FCC ID: 2BHCY-X100 Dear Sir/Madam, We, Shenzhen Songya Technology Co., Ltd. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Mobile Phone Model no.: X100, x10, X20, x30, x50, x60, x70, x80, x90, x11, x12, X13, x15, x16, x17, x18, x19, x21, x22, x23, x25 Sincerely, Name/Title: Yuehu Chen/Manager Company: Shenzhen Songya Technology Co., Ltd. Address: 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Phone: 13603034005 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-7-17> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BHCY-X100 X100 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Yuehu Chen/Manager Company: Shenzhen Songya Technology Co., Ltd. Address: 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Phone: 13603034005 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Shenzhen Songya Technology Co., Ltd. 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-7-17 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BHCY-X100 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Yuehu Chen/Manager Company: Shenzhen Songya Technology Co., Ltd. Address: 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Phone: 13603034005 Fax: N/A E-Mail: [email protected]

External Photos

FCC ID: 2BHCY-X100 External Photos of the EUT FCC ID: 2BHCY-X100 FCC ID: 2BHCY-X100

ID Label/Location Info

Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BHCY-X100

Internal Photos

FCC ID: 2BHCY-X100 Internal Photos of the EUT LTE ANT BT/WIFI ANT DIV LTE ANT FCC ID: 2BHCY-X100 FCC ID: 2BHCY-X100 FCC ID: 2BHCY-X100 FCC ID: 2BHCY-X100 FCC ID: 2BHCY-X100

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China TEST REPORT Report Reference No. ..................... : FCC ID ............................................ : CTA24061201218 2BHCY-X100 Compiled by ( position+printed name+signature) .. : File administrators Jinghua Xiao Supervised by ( position+printed name+signature) .. : Project Engineer Lushan Kong Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : June 22, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Shenzhen ThreeTigers Trading co..Ltd. Address ............................................ : 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Test specification ........................... : Standard ........................................... : IEC 62209-2:2010; IEEE 1528:2013; FCC 47 CFR Part 2.1093; ANSI/IEEE C95.1:2005; Reference FCC KDB 447498; KDB 248227; KDB 616217; KDB 941225; KDB 865664 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ...................... : Mobile Phone Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen ThreeTigers Trading co..Ltd. Model/Type reference ....................... : X100 Listed Models .................................. : x10, X20, x30, x50, x60, x70, x80, x90, x11, x12, X13, x15, x16, x17, x18, x19, x21, x22, x23, x25 Rating ............................................... : DC 3.8V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA24061201218 Page 2 of 160 T E S T R E P O R T Equipment under Test : Mobile Phone Model /Type : X100 Listed Models : x10, X20, x30, x50, x60, x70, x80, x90, x11, x12, X13, x15, x16, x17, x18, x19, x21, x22, x23, x25 Applicant : Shenzhen ThreeTigers Trading co..Ltd. Address : 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Manufacturer : Shenzhen ThreeTigers Trading co..Ltd. Address : 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24061201218 Page 3 of 160 Contents 1 Statement of Compliance ............................................................................................................................. 6 2 General Information ..................................................................................................................................... 7 2.1 General Remarks ............................................................................................................................................. 7 2.2 Description of Equipment Under Test (EUT) ..................................................................................................... 7 2.3 Device Category and SAR Limits ..................................................................................................................... 8 2.4 Applied Standard .............................................................................................................................................. 8 2.5 Test Facility ....................................................................................................................................................... 9 2.6 Environment of Test Site ................................................................................................................................... 9 2.7 Test Configuration ............................................................................................................................................. 9 3 Specific Absorption Rate (SAR) ................................................................................................................. 10 3.1 Introduction ..................................................................................................................................................... 10 3.2 SAR Definition ................................................................................................................................................ 10 4 SAR Measurement System ........................................................................................................................ 11 4.1 E-Field Probe ................................................................................................................................................... 11 4.2 Data Acquisition Electronics (DAE) ................................................................................................................. 12 4.3 Robot .............................................................................................................................................................. 13 4.4 Measurement Server ......................................................................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: CTA24061201218 Page 116 of 160 Report No.: CTA24061201218 Page 117 of 160 Report No.: CTA24061201218 Page 118 of 160 Report No.: CTA24061201218 Page 119 of 160 Report No.: CTA24061201218 Page 120 of 160 Report No.: CTA24061201218 Page 121 of 160 Report No.: CTA24061201218 Page 122 of 160 Report No.: CTA24061201218 Page 123 of 160 Report No.: CTA24061201218 Page 124 of 160 Report No.: CTA24061201218 Page 125 of 160 Report No.: CTA24061201218 Page 126 of 160 Report No.: CTA24061201218 Page 127 of 160 Report No.: CTA24061201218 Page 128 of 160 Report No.: CTA24061201218 Page 129 of 160 Report No.: CTA24061201218 Page 130 of 160 Report No.: CTA24061201218 Page 131 of 160 Report No.: CTA24061201218 Page 132 of 160 Report No.: CTA24061201218 Page 133 of 160 Report No.: CTA24061201218 Page 134 of 160 Report No.: CTA24061201218 Page 135 of 160 Report No.: CTA24061201218 Page 136 of 160 Report No.: CTA24061201218 Page 137 of 160 Report No.: CTA24061201218 Page 138 of 160 Report No.: CTA24061201218 Page 139 of 160 Report No.: CTA24061201218 Page 140 of 160 Report No.: CTA24061201218 Page 141 of 160

RF Exposure Info

Report No.: CTA24061201218 Page 142 of 160 Report No.: CTA24061201218 Page 143 of 160 Report No.: CTA24061201218 Page 144 of 160 Report No.: CTA24061201218 Page 145 of 160 Report No.: CTA24061201218 Page 146 of 160 Report No.: CTA24061201218 Page 147 of 160 Report No.: CTA24061201218 Page 148 of 160 Report No.: CTA24061201218 Page 149 of 160 Report No.: CTA24061201218 Page 150 of 160 Report No.: CTA24061201218 Page 151 of 160 Report No.: CTA24061201218 Page 152 of 160 Report No.: CTA24061201218 Page 153 of 160 Report No.: CTA24061201218 Page 154 of 160 Report No.: CTA24061201218 Page 155 of 160 Report No.: CTA24061201218 Page 156 of 160 Report No.: CTA24061201218 Page 157 of 160 Report No.: CTA24061201218 Page 158 of 160 Report No.: CTA24061201218 Page 159 of 160 Report No.: CTA24061201218 Page 160 of 160 *****END OF REPORT*****

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID............................................. : CTA24061201202 2BHCY-X100 Compiled by ( position+printed name+signature) . : File administrators Jinghua Xiao Supervised by ( position+printed name+signature) . : Project Engineer Lushan Kong Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jun. 19, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Shenzhen ThreeTigers Trading co..Ltd. Address ............................................ : 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Mobile Phone Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen ThreeTigers Trading co..Ltd. Model/Type reference ...................... : X100 Listed Models .................................. : x10, X20, x30, x50, x60, x70, x80, x90, x11, x12, X13, x15, x16, x17, x18, x19, x21, x22, x23, x25 Modulation ....................................... : GFSK, Π/4DQPSK, 8DPSK Frequency ......................................... From 2402MHz to 2480MHz Rating ............................................... : DC 3.8V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA24061201202 Page 2 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Mobile Phone Model /Type : X100 Listed Models : x10, X20, x30, x50, x60, x70, x80, x90, x11, x12, X13, x15, x16, x17, x18, x19, x21, x22, x23, x25 Applicant : Shenzhen ThreeTigers Trading co..Ltd. Address : 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Manufacturer : Shenzhen ThreeTigers Trading co..Ltd. Address : 14C-25Rainbow Building, RainbowXindu, No.3002 Caitian South Road, Gangxia Community, Futian District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24061201202 Page 3 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 6 2.6 Block Diagram of Test Setup 6 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 11 4.1 AC Power Conducted Emission 11 4.2 Radiated Emission 14 4.3 Maximum Peak Output Power 20 4.4 20dB Bandwidth 21 4.5 Frequency Separation 25 4.6 Number of hopping frequency 27 4.7 Time of Occupancy (Dwell Time) 29 4.8 Out-of-band Emissions 33 4.9 Pseudorandom Frequency Hopping Sequence 42 4.10 Antenna Requirement 43 5 T E S T SE T U P P H O T O S O F T H E E U T ......................................... 44 6 P H O T O S O F T H E E U T ........................................................... 45 Report No.: CTA24061201202 Page 4 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices Report No.: CTA24061201202 Page 5 of 45 Shenz…

Text truncated - open the document above for the full version.

Test Report

Report No.: CTA24061201202 Page 35 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn GFSK(CH78) π/4DQPSK (CH00) reference reference 30MHz-1G 30MHz-1G 1G-25G 1G-25G Report No.: CTA24061201202 Page 36 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn π/4DQPSK (CH39) π/4DQPSK (CH78) reference reference 30MHz-1G 30MHz-1G 1G-25G 1G-25G Report No.: CTA24061201202 Page 37 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 8DPSK (CH00) 8DPSK (CH39) reference reference 30MHz-1G 30MHz-1G 1G-25G 1G-25G Report No.: CTA24061201202 Page 38 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 8DPSK (CH78) reference 30MHz-1G 3G-25G Report No.: CTA24061201202 Page 39 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Band-edge Measurements for RF Conducted Emissions: GFSK Left Band edge hoping off Right Band edge hoping off Left Band edge hoping on Right Band edge hoping on Report No.: CTA24061201202 Page 40 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn π/4DQPSK Left Band edge hoping off Right Band edge hoping off Left Band edge hoping on Right Band edge hoping on Report No.: CTA24061201202 Page 41 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 8DPSK Left Band edge hoping off Right Band edge hoping off Left Band edge hoping on Right Band edge hoping on Report No.: CTA24061201202 Page 42 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 4.9 Pseudorandom Frequency Hopping Sequence TEST APPLICABLE For 47 CFR Part 15C section 15.247 (a) (1) requirement: Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hop-ping channel, whichever is greater. Alternatively, frequency hopping systems operating in the 2400–2483.5 MHz band may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater, provided the systems operate with an output power no greater than 125 mW. The system shall hop to channel frequencies that are selected at the system hopping rate from a pseudo randomly ordered list of hopping frequencies. Each frequency must be used equally on the average by each transmitter. The system receivers shall have input bandwidths that match the hop-ping channel bandwidths of their corresponding transmitters and shall shift frequencies in synchronization with the transmitted signals. EUT Pseudorandom Frequency Hopping Sequence Requirement The pseudorandom frequency hopping sequence may be generated in a nice-stage shift register whose 5 th and 9 th stage outputs are added in a modulo-two addition stage. And the result is fed back to the input of the first stage. The sequence begins with the first one of 9 consecutive ones, for example: the shift register is initialized with nine ones. ● Number of shift register stages:9 ● Length of pseudo-random sequence:29-1=511 bits ● Longest sequence of zeros:8(non-inverted signal) An example of pseudorandom frequency hopping sequence as follows: Each frequency used equally one the average by each transmitter. The system receiver have input bandwidths that match the hopping channel bandwidths of their corresponding transmitter and shift frequencies in synchronization with the transmitted signals. Report No.: CTA24061201202 Page 43 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 4.10 Antenna Requirement Standard Applicable For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And according to FCC 47 CFR Section 15.247 (c), if transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi. Refer to statement below for compliance The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to intentional radiators that must be professionally installed. Antenna Connected Construction The maximum gain of antenna was 1.25 dBi. Remark:The antenna gain is provided by the customer , if the data provided by the customer is not accurate, Shenzhen CTA Testing Technology Co., Ltd. does not a…

Text truncated - open the document above for the full version.

Test Report

1. Antenna Description: Antenna type PIFA antenna Model X100-BT Frequency range 2400-2500MHz Manufacturer Shenzhen Sanzhi Tiger Trading Co.,Ltd. ANT Peak Gain 1.25 dBi 2. Antenna Photo: Length :25.99mm Width:14.59mm 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz

Test Setup Photos

FCC ID: 2BHCY-X100 Test Setup Photos of the EUT

Contact Information

Applicant

Yuehu Chen
[email protected]13603034005Fax: /

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]+86 755 2322 5875

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.