2BHJW-MD-F01Multi-functional Drying Cabinet

Shenzhen MINGDA TECHNOLOGY CO.,LTD
Multi-functional Drying Cabinet - FCC ID 2BHJW-MD-F01 - Shenzhen MINGDA TECHNOLOGY CO.,LTD
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Nov 23, 2025
Application Purpose
Original Equipment
Equipment Note
Multi-functional Drying Cabinet
Company
Shenzhen MINGDA TECHNOLOGY CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MD-F01FilamentFeedingCabinetUserManual V1.0 1. ProductOverview The MD-F01SmartDry Cabinetis an intelligentdryingand filamentmanagement systemdesignedspecificallyfor 3D printingmaterials.Integrating temperature/humiditymonitoring,auto-dehumidification,filamentdetection, automaticfeeding/retracting,and auto-replenishmentcapabilities,thissystem effectivelyaddressesfilamentmoistureabsorption,breakage,and supply interruptions,ensuringenhancedprintqualityand workflowefficiency. 2. FunctionalFeatures 2.1AutomaticDrying& Dehumidification Real-timemonitoringof internaltemperatureand humidity. Auto-dehumidification:Adjustsheatingand fan operationsbasedon humidity levels. Smartdryingcycle:Sequentialphases(40minheating→30mindehumidification → 10minreheating → 30minfinaldehumidification). 2.2FilamentManagement 6 filamentslots(3 left,3 right). Filamentpresencedetectionfor eachslot. Weightmonitoring:Alertswhenfilamentweightdropsbelowpresetthresholds. Multi-distancefeeding/retracting:Supportsshort(50mm,100mm,500mm)and long-distance(3000mm)operations. 2.3Auto-Replenishment Detectsfilamentbreaksduringprinting. Automaticallyswitchesto availablespools. Prioritizesspoolswithsufficientweight. 2.4Auto-Feeding Detectsfilamentshortagesin realtime. Proactivelyfeedsfilamentto the printer. 2.5SmartFilamentSwitching Automatedretractionand feeding. Success/failuredetectionwithtimeoutprotection. 2.6LightingControl Autoon/off: Activateswhendooropens/closes. Manualoverridevia settings. 2.7AlarmSystem Door-openalarm. Filamentabsencealarm. Lowfilamentweightalarm. 3. InterfaceGuide 3.1StatusBar Displays: Mingdalogo. Currenttemperature/humidity. Heating/fanstatus. Screen-mainboardconnectionstatus. Doorstatus. Filamentdetection(leftto right). 3.2TabBar Left-sidetabs: FilamentManagement. FeedingControl. SystemSettings. 3.3FilamentInformationInterface Detailsinclude: Filamentcolor. Materialtype(e.g.,PLA). Weight. SlotID (1–6). 3.4FilamentSettingsInterface Adjustments:a.Materialtype(dropdownmenu).b.Spoolweight(numericinput).c. Colorselection(colorblocks). Tarefunction:Zeroweightcalibration. Swipeto switchbetweenslotIDs. 3.5Feeding/RetractingControl Functions: Feed/retractwithadjustabledistances. SwitchbetweenpresetslotIDs (1 – 6). 3.6SystemSettings Configurableoptions: Language(English/Chinese). Screentimeout: Tap to wake,pressknobto sleep. Auto-feedingsettings. Lightingcontrol. Buzzeralarms. Heaterfunction. Firmwareversioncheck. 4. UserGuide 4.1Power-On& Initialization 1.Connectpower;systemauto-initializes. 2.Post-initializationstatuscheck. 3.Verifyfilamentslotstatus/weightduringfirstuse. 4.2DryingFunction Humidity> 20%:Fulldryingcycle(40/30/10/30mins). 15%< Humidity≤20%:Fan + heateractivation. Humidity ≤ 15% : Idlemode.Note:Doormustbe closedfor drying. 4.3Feeding/RetractingOperations Steps: 1.Disableauto-feedingin settings. 2.SelectslotID (1–6). 3.Choosedistance(50mm – 3000mm). 4.Startfeed/retract.Clickreversebuttonto halt. Notes: Directionchangesrequiremotionstop. Occupiedslotstriggerauto-switching. Manualoperationsdisabledduringprinting. 4.4Auto-Replenishment 1.Enablefeature. 2.Systemretriesfeedingor switchesfilamentsuponbreakage. 3.Alarmsif unresolvedaftermultipleattempts. 4.5Auto-Feeding 1.Enablefeature. 2.Systemdetectsshortagesand feedsproactively. 4.6FilamentSwitching 1.Selecttargetslotand click"Feed". 2.If occupied,systemexecutesretract-feedsequence. 3.Updatesactiveslotpost-switch. Notes: Leftslots(1 – 3) and rightslots(4 – 6) are independent. Cutfilamentfromnozzlebeforeswitching. Timeoutprotectionincluded. 4.7LightingControl Autoon/offwithdoor. Manualtogglevia settings. 4.8AlarmSystem Monitors: Opendoor. Missingfilamentduringprinting. Low filamentweight.Adjustbuzzervolumein settings. 5. FAQs& Troubleshooting 5.1SystemUnresponsive Checkpower/cableconnections. Restart. 5.2PoorDrying Ensuredoorclosure. Verifyheater/fanfunctionality. Inspectsensors. 5.3FeedingIssues Clearjams/tangles. Checksensorsand motors. 5.4Auto-ReplenishmentFailure Confirmavailablespools/sufficientweight. Inspectsensors. 5.5WeightDisplayErrors Calibratescale. Ensurestableplacement. Reboot. 6. Maintenance 6.1RegularCleaning Cleaninteriorfor dryness. Wipesensorsand scalesurfaces. 6.2SensorCalibration Temp/humiditysensors:No calibrationneeded. Scale:Periodiccalibration(referto manual). 7. SafetyPrecautions Avoidcontactwithheatedcomponents. Do notuse in humidenvironments. No disassembly/modification. Disconnectpowerduringprolongedinactivity. Keepawayfromchildren. 8. Contact& Support For assistance: TechSupport:(+86)13530306290(WhatsApp). Email:<[email protected]>. Website: https://www.3dmingda.com. Thankyou forchoosingMD-F01.Happyprinting! This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving an…

Text truncated - open the document above for the full version.

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Herland International Trading Inc FRN: 0036324101 Contact Name: Jianfeng Gao Address: 1370 Valley Vista Dr Ste 200 Diamond Bar California 91765-3921 Telephone No: 001-909-772-1888 Email: [email protected] Applicant: Company name: Shenzhen MINGDA TECHNOLOGY CO.,LTD Product Description: Multi-functional Drying Cabinet Grantee code: 2BHJW FCC ID: 2BHJW-MD-F01 FRN: 0035676014 Contact Name: Jack bu Address: 301, Building 2, No. 19, Dahe Industrial Zone, Guanhu Street, Longhua District, Shenzhen Telephone No: 18906679427 Email: [email protected] [Shenzhen MINGDA TECHNOLOGY CO.,LTD] certifies that, as of the date of this filing of the application with the TCB, [Herland International Trading Inc] is our designated US agent for service of process for the above referenced FCC ID. [Shenzhen MINGDA TECHNOLOGY CO.,LTD] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Herland International Trading Inc] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2025/11/07 Applicant’s Name: Jack bu US Agent’s Name: Jianfeng Gao Title: Manager Title: Manager Signature Signature

Attestation Statements

Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 Shenzhen MINGDA TECHNOLOGY CO.,LTD TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen MINGDA TECHNOLOGY CO.,LTD Grantee code: 2BHJW FCC ID: 2BHJW-MD-F01 FRN: 0035676014 Contact Name: Jake bu Address: 301, Building 2, No. 19, Dahe Industrial Zone, Guanhu Street, Longhua District, Shenzhen Telephone No: 18906679427 Fax No: 18906679427 Email: [email protected] i. [Shenzhen MINGDA TECHNOLOGY CO.,LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen MINGDA TECHNOLOGY CO.,LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen MINGDA TECHNOLOGY CO.,LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2025/11/07 Applicant’s Name: Jack bu Title: Manager Signature: 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

Shenzhen MINGDA TECHNOLOGY CO.,LTD Code 00018768 Ed. 1 Item 1. The device is able to install software/program installation? ☐ Yes, go to Item 2. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A Device Multi-functional Drying Cabinet Company name Shenzhen MINGDA TECHNOLOGY CO.,LTD Grantee code 2BHJW FCC ID 2BHJW-MD-F01 FRN 0035676014 Contact name Jack bu Address 301, Building 2, No. 19, Dahe Industrial Zone, Guanhu Street, Longhua District, Shenzhen Telephone number 18906679427 E-mail [email protected] Chipset/module information STM32F103RBT6 Operating System (if applicable) N/A Storage Capacity (hard drive or other permanent memory storage, if applicable) N/A 2 # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: Android™ 10 – 14 N/A 3 Screen Resolution: Minimum resolution of 320 x 480 N/A # General Requirements (for iOS devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A # General Requirements (For Linux system) Yes / No or N/A Comments 3 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher N/A 3 RAM: 1 GB N/A 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; N/A After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? ☐ Yes, go to Item 3. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software Item 3. Connectivity Capabilities: 4 # Physical Interface Purpose Justification 1 1 # Wireless Interface Purpose Justification 1 1 After the review of this items, the device: ☒ Cannot support installation of any cybersecurity or anti-virus software on the covered list. ☐ Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third- party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies ignature: Name: Jack bu Date:2025-11-07 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications.

Attestation Statements

TCB CALL página 1 File FCC ID: 2BHJW-MD-F01 Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : Search | California Secretary of State TCB CALL página 2 TCB CALL página 3 TCB CALL página 4 TCB CALL página 5 TCB CALL página 6 TCB CALL página 7 TCB CALL página 8 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter" >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Shenzhen MINGDA TECHNOLOGY CO.,LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2025.11.07 Subject: Request for Confidentiality FCC ID: 2BHJW-MD-F01 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name: Jack bu Title: Manager 2025.11.07

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen MINGDA TECHNOLOGY CO.,LTD Company: Shenzhen MINGDA TECHNOLOGY CO.,LTD Address: 301, Building 2, No. 19, Dahe Industrial Zone, Guanhu Street, Longhua District, Shenzhen Product Name: Multi-functional Drying Cabinet Model Number: MD-F01 FCC Identifier: 2BHJW-MD-F01 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jack bu Date: 2025.11.07 Title: Manager Signature of applicant:

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size: 35*30mm M/N: MD-F01 FCC ID: 2BHJW-MD-F01 Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-250110004ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 14 FCC TEST REPORT FCC ID: 2BHJW-MD-F01 Applicant: Shenzhen Mingda Technology Co.,Ltd Address: 301, Building 2, No. 19, Dahe Industrial Zone, Guanhu Street, Longhua District, Shenzhen Manufacturer: Shenzhen Mingda Technology Co.,Ltd Address: 301, Building 2, No. 19, Dahe Industrial Zone, Guanhu Street, Longhua District, Shenzhen EUT: Multi-functional Drying Cabinet Trade Mark: MINGDA Model Number: MD-F01 Date of Receipt: Mar. 20, 2025 Test Date: Mar. 20, 2025 - Mar. 28, 2025 Date of Report: Mar. 28, 2025 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC Part 15 Subpart B ANSI C63.4:2014 Test Result: Pass Report Number: DL-250110004ER Prepared (Test Engineer): Ken Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-250110004ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 14 TABLE OF CONTENT Test Report Declaration Page 1. VERSION .................................................................................................................................. 3 2. TEST SUMMARY .................................................................................................................... 3 3. ENERAL INFORMATION ...................................................................................................... 4 4. TEST INSTRUMENT USED .................................................................................................. 5 5. CONDUCTED EMISSION TEST .......................................................................................... 6 6. RADIATION EMISSION TEST ............................................................................................ 10 7. TEST SEUUP PHOTO.......................................................................................................... 14 8. EUT PHOTOGRAPHS.......................................................................................................... 14 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-250110004ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 14 1. VERSION Version No. Date Description 00 Mar. 28, 2025 Original 2. TEST SUMMARY EMC Emission Standard Test Item Limit Result Remark FCC PART 15 B Conducted Emission at power ports Class B PASS Radiated Emission below 1GHz Class B PASS Radiated Emission above 1GHz Class B N/A NOTE: (1)” N/A” denotes test is not applicable in this Test Report (2) Test Facility: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China (3) The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the lssuing DL Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the DL Testing, responsible for this Test Report. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-250110004ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 14 3. ENERAL INFORMATION 3.1 Description of Device (EUT) EUT: Multi-functional Drying Cabinet Trade Mark: MINGDA Model Number: MD-F01 Test Model: MD-F01 Model difference: N/A Power Supply: 100-240V~ 50/60Hz Working Frequency: Below 108MHz NOTE: (1) For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. (2) The EUT’s all information provided by client. 3.2 Tested System Details None. 3.3 Block Diagram of Test Set-up 3.4 Test Mode Description Mode1. : On Mode 3.5 Test Auxiliary Equipment None. 3.6 Test Uncertainty Conducted Emission Uncertainty : ±2.56dB Radiated Emission Uncertainty : ±3.24dB AC Mains EUT Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-250110004ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 14 4. TEST INSTRUMENT USED For Conducted Emission Test (843 Shielded Room) Equipment Manufacturer Model Serial Last Cal. Next Cal. 843 Shielded Room YIHENG 843 Room 843 Nov. 05, 2023 Nov. 04, 2026 EMI Receiver R&S ESR 101421 Nov. 01, 2024 Oct. 31, 2025 LISN R&S ENV216 102417 Nov. 01, 2024 Oct. 31, 2025 Clamp COM-POWER CLA-050 431072 Nov. 02, 2024 Nov. 01, 2025 3-Loop Antenna DAZE ZN30401 13021 Nov. 02, 2024 Nov. 01, 2025 ISN T8 Schwarzbeck NTFM 8158 101135 Nov. 01, 2024 Oct. 31, 2025 ISN T5 Schwarzbeck NTFM 8158 101136 Nov. 01, 2024 Oct. 31, 2025 843 Cable 1# ChengYu CE Cable 001 Nov. 01, 2024 Oct. 31, 2025 843 Cable 1# ChengYu CL Cable 002 Nov. 01, 2024 Oct. 31, 2025 For Radiated Emission Test (966 chamber) Other Equipment Manufacturer Model Serial Last Cal. Next Cal. 966 chamber YIHENG 966 Room 966 Nov. 06, 2023 Nov. 05, 2026 Spectrum Analyzer Agilent E4408B MY50140780 Nov. 01, 2024 Oct. 31, 2025 EMI Receiver R&S ESRP7 101393 Nov. 01, 2024 Oct. 31, 2025 Amplifier Schwarzbeck BBV9743B 00153 Nov. 01, 2024 Oct. 31, 2025 Amplifier EMEC EM01G8GA 00270 Nov. 01, 2024 Oct. 31, 2025 Broadband Trilog Antenna Schwarzbeck VULB9162 00306 Nov. 02, 2024 Nov. 01, 2025 Horn Antenna Schwarzbeck BBHA9120D 02139 Nov. 02, 2024 Nov. 01, 2025 966 Cable 1# ChengYu 966 004 Nov. 01, 2024 Oct. 31, 2025 966 Cable 2# ChengYu 966 003 Nov. 01, 2024 Oct. 31, 2025 Name Manufacturer Model Software vers…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos Conducted Emission Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

jack bu
[email protected]Fax: 18906679427

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from Shenzhen MINGDA TECHNOLOGY CO.,LTD

3D Printer - FCC ID 2BHJW-RAPTOR450 - Shenzhen MINGDA TECHNOLOGY CO.,LTD
2BHJW-RAPTOR450

3D Printer

Aug 14, 2026

Equipment Class

DTS - Digital Transmission System