FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shunhetai (Shenzhen) Technology Co., Ltd./
  3. 2BHMG-T33B

2BHMG-T33BPower Pod Max

Shunhetai (Shenzhen) Technology Co., Ltd.
Power Pod Max - FCC ID 2BHMG-T33B - Shunhetai (Shenzhen) Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Dec 04, 2024
Application Purpose
Original Equipment
Date of Application
Dec 04, 2024
Equipment Note
Power Pod Max
Frequency Range
0.36000000 - 0.36000000
Company
Shunhetai (Shenzhen) Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.

Attestation Statements

(Shunhetai (Shenzhen) Technology Co., Ltd.) (2024.11.28) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BHMG-T33B) [Shunhetai (Shenzhen) Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Client’s signature: Client’s name : Gary Ye (Shunhetai (Shenzhen) Technology Co., Ltd.) (2024.11.28) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BHMG-T33B) [Shunhetai (Shenzhen) Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Client’s signature: Client’s name : Gary Ye

Attestation Statements

Attestation Statements (2024/11/ 2 8} TO: Federal Communications Commis sion Authorization and Evaluation Division 7435 Oakland Mills Roa d Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2BHMG-T33B) (Shunhetai (Shenzhen) Technology Co., Ltd.), the undersigned, hereby authorize ANTEK SERVICE INC t o act as our designated U.S. agent for service of process, (Shunhetai (Shenzhen) Technology Co., Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related p roceeding imrnlving the equipment. ANTEK SERVICE INC a ccepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company Name: Shunhetai (Shenzhen) Technology Co., Ltd. Address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajing Road, Xitou, Songgang Street, Bao'an, Shenzhen, China Contact Name: Gary Ye FRN:0035694009 Telephone No: 13423732628 Email: [email protected] 知j·Je Signature [Gary Ye] U.S. Agent Information: Company Name: ANTEK SERVICE INC Address:901 N PENNSYLVANIA ST STE O DENVER, CO 80203 United States FRN:0033437609 Contact Name: Shirley Kwok Telephone No: 01 303-8006306 Email:[email protected] 三 Signature [Shirley Kwok/Manager)

Cover Letter(s)

Shunhetai (Shenzhen) Technology Co., Ltd. 2024.11.28 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : Gary Ye/ Compliance Engineer Contact information / address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajing Road, Xitou, Songgang Street, Bao’an, Shenzhen, China

Cover Letter(s)

Shunhetai (Shenzhen) Technology Co., Ltd. 2024.11.28 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Power Pod Max Trademark: N/A MODEL: T33B FCC ID: 2BHMG-T33B To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : Gary Ye/ Compliance Engineer Contact information / address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajing Road, Xitou, Songgang Street, Bao’an, Shenzhen, China

External Photos

External Photos

ID Label/Location Info

Location Label FCC ID: 2BHMG-T33B

Internal Photos

Internal Photos Antenna

RF Exposure Info

No.:BCTC/RF-EMC-005 Page 1 of 16 Edition:B.2 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2410515911-2E Applicant: Shunhetai (Shenzhen) Technology Co., Ltd. Product Name: Power Pod Max Test Model: T33B Tested Date: 2024-10-15 to 2024-10-21 Issued Date: 2024-10-21 Report No.: BCTC2410515911-2E No.:BCTC/RF-EMC-005 Page 2 of 16 Edition:B.2 FCC ID: 2BHMG-T33B The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Power Pod Max Trademark: N/A Model/Type Reference: T33B Prepared For: Shunhetai (Shenzhen) Technology Co., Ltd. Address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajiang Road, Xitou, Songgang Street, Bao’an, Shenzhen, China Manufacturer: Shunhetai (Shenzhen) Technology Co., Ltd. Address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajiang Road, Xitou, Songgang Street, Bao’an, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2024-10-15 Sample Tested Date: 2024-10-15 to 2024-10-21 Issue Date: 2024-10-21 Report No.: BCTC2410515911-2E Test Standards: FCC CFR 47 part1, 1.1307(b), 1.1310 Test Results: PASS Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2410515911-2E No.:BCTC/RF-EMC-005 Page 3 of 16 Edition:B.2 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 4 2. Product Information ............................................................................................... 5 2.1 Product Information ............................................................................................... 5 2.2 Support Equipment ............................................................................................... 5 2.3 Test Mode ............................................................................................................. 5 3. Test Facility And Test Instrument Used ................................................................. 6 3.1 Test Facility ........................................................................................................... 6 3.2 Test Instrument Used ............................................................................................ 6 4. Method Of Measurement ....................................................................................... 7 4.1 Applicable Standard .............................................................................................. 7 4.2 Block Diagram Of Test Setup ................................................................................ 7 4.3 Limit ...................................................................................................................... 8 4.4 Test procedure ...................................................................................................... 8 4.5 Equipment Approval Considerations ..................................................................... 9 4.6 E and H field Strength ......................................................................................... 10 5. Photographs Of Test Set-Up ............................................................................... 15 (Note: N/A Means Not Applicable) Report No.: BCTC2410515911-2E No.:BCTC/RF-EMC-005 Page 4 of 16 Edition:B.2 1. Version Report No. Issue Date Description Approved BCTC2410515911-2E 2024-10-21 Original Valid Report No.: BCTC2410515911-2E No.:BCTC/RF-EMC-005 Page 5 of 16 Edition:B.2 2. Product Information 2.1 Product Information Model/Type Reference: T33B (Test color is black) Model Differences: N/A Hardware Version: N/A Software Version: N/A Modulation: ASK Operation Frequency: 115kHz-205kHz, 360kHz Antenna installation: loop coil antenna Ratings: Type-C 1: DC 5V/3A, DC 9V/2.22A, DC 12V/1.67A Type-C 2: DC 5V/3A, DC 9V/2.22A, DC 12V/1.67A Wireless charging: 15W (Max) Battery: DC 7.2V 2.2 Support Equipment No. Device Type Brand Model Series No. Note E-1 Power Pod Max N/A T33B N/A EUT E-2 ADAPTER Hoco. N18 N/A Auxiliary E-3 Dummy load N/A DL01 N/A Auxiliary Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. 2.3 Test Mode AC Mode Mode 1 Charging+Full Load(115-205kHz, 5W) DC Mode Mode 2 Full Load(360kHz, 15W) Mode 3 Half Load(115-205kHz, 7.5W) Mode 4 Null Load(115-205kHz) Note: All test mode were tested and passed, only shows the worst case mode which were recorded in this report. Report No.: BCTC2410515911-2E No.:BCTC/RF-EMC-005 Page 6 of 16 Edition:B.2 3. Test Facility And Test Instrument Used 3.1 Test Facility All measurement facilities used to collect the measurement data are located at Shenzhen BCTC Testing Co., Ltd. Address:1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. The site and apparatus are constructed in conformance with the requirements of ANSI C63.4 and CISPR 16-1-1 other equivalent standards. FCC Test Firm Registration Number: 712850 A2LA certificate registration number is: CN1212 ISED Registered No.: 23583 ISED CAB identifier: CN0017 3.2 Test Instrument Used EMF Test Equipment Manufacturer Model# Serial# Last Cal. Next Cal. Electromagnet -ic radiation tester Wavecontrol SMP160 19SN0980 May 25, 2024 May 24, 2025 Electromagnet -ic field probe Wavecontrol WP400-3 20WP120082 M…

Text truncated - open the document above for the full version.

Test Report

FY-GZ001 深圳市立诚兴科技有限公司 承认书 客戶: CUSTOMER: SPECIFICATIONFORAPPROVAL 深圳市星之豪科技有限公司(KH268) 客戶料號: CUSTP/N: 内部料號: LCXP/N: 産品型號: DESC: 日期: DATE: 版本: Version: 30900134 LCX-KH268TX001 Φ21.7*40-0.08*72P-11TS-65-42.42L065C+1808C-BJ 2024/10/30 A.0 制作 PREPAREDBY 审核 CHECKEDBY 批准 APPROVEDBY 客戶承认 CUSTOMERAPPROVE 杨文俊 2024/10/30 高应洪 2024/10/30 地址:深圳市龙华区观澜街道牛湖社区新湖路365号四楼 电话:13828741697 E-mail:[email protected] FY-GZ001 产品规格书SPECIFICATION 图纸编号:LCX-GCQP001239 版本 A/0 制作:杨文俊 2024/10/30 审核:高应洪 2024/10/30 页码:2/4客户代码:CUST KH268 规格型号 Φ21.7*40-0.08*72P-11TS-65- 42.42L065C+1808C-BJ 客户料号:CUSTP/N 30900134 内部料号:INP/N LXC-KH268TX002 版本变更履历 VersionChangeHistory 版本 Rev 变更前 BeforeChange 变更后 AfterChange 更改日期 ChangeDate 批准 ApprovedBy A/0新发行-----2024/10/30高应洪 物料清单 Billofmaterial 序号物料名称内部料号物料规格单位用量备注 1 线圈多股漆包线 0.08*80P 克 4.41 2 硬磁片Φ42.4*1.0材质PN40 PCS1 双槽不带孔一面黑 膜 3 硬磁片Φ18*0.8材质PN40 PCS1 4 普通双面胶Φ 42*0.05 PCS1双面背胶带手撕位 5 高温胶带 5*15*0.03PCS1 6 透明热缩管 15*0.8PCS1 7 无铅锡条 Su99.3Cu0.7 克 8 黄胶 405 克 以下空白 FY-GZ001 产品规格书SPECIFICATION 图纸编号:LCX-GCQP001239 版本 A/0 制作:杨文俊 2024/10/30 审核:高应洪 2024/10/30 页码:3/4客户代码:CUST KH268 规格型号 Φ21.7*40-0.08*72P-11TS-65- 42.42L065C+1808C-BJ 客户料号:CUSTP/N 30900134 内部料号:INP/NLXC-KH268TX002 ABCDEFGHH1H2-------------- 21.7 ±0.5 40 ±1 42.4 ±0.5 17.7 Ref 2.2 Ref 65 ±2 3 ±1 0.65 ±0.1 0.8 ±0.1 1.65 ±0.15 --------------- 一、尺寸DIMENSION:(mm)绕线模具:Φ21.7线圈单重:4.41 备注: 1.线圈如图一所示顺时针绕线,线圈不能散线,松线,引线不交叉出线,出线单线包5mm宽高温胶带一到两圈, 起始线套一15*0.8透明热缩管,套到线根部。注意线圈打线时两引线不能硬化 2.磁片如图二所示,规格:42.4*0.65双槽不带孔,磁片正面贴同磁片规格的黑膜(此面贴线圈) 3.线圈如图三所示居中贴合线圈反贴,内线从磁片槽位出线,外线对磁片小口。 4.线圈正面磁片中间贴小磁片,规格:18*0.8,反面贴普通双面胶,带手撕位。 二、原理图SCHEMATICDIAGRAM: 三、绕线参数WindingSpecification: 序号 NO 端子 TERMINAL 线径 WIRE 线材分解温度 Temperature 圈数 Turns 绕线方向 WindingDirection L1SF 多股漆包线线0.08*72P 180-250度 11TS 顺时针 四、电气特性ELECTRICALCHARACTERISTIC:: 温度TEMPERATURE:25±10°C,湿度RELATIVEHUMIDITY:65±20% 序 号 磁片材质 Diskmaterial 电感量 LS 阻抗 DCR 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS 1 / 4.6uH±0.5%(单线 圈) 85mΩ ±10% 100KHz/1.0VU2832 2硬磁片 8.1±0.5UH(贴合磁 片) 85mΩ±10% 100KHz/1.0V U2832 FY-GZ001 产品规格书SPECIFICATION 图纸编号:LCX-GCQP001239 版本 A/0 制作:杨文俊 2024/10/30 审核:高应洪 2024/10/30 页码:4/4 客户代码:CUST KH268 规格型号 Φ21.7*40-0.08*72P-11TS-65- 42.42L065C+1808C-BJ 客户料号:CUSTP/N 30900134 内部料号:INP/NLXC-KH268TX002 六、包装方式Packingway: 泡棉盒包装

Test Report

No.:BCTC/RF-EMC-005 Page 1 of 29 Edition:B.2 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2410515911-1E Applicant: Shunhetai (Shenzhen) Technology Co., Ltd. Product Name: Power Pod Max Test Model: T33B Tested Date: 2024-10-15 to 2024-10-21 Issued Date: 2024-10-21 Report No.: BCTC2410515911-1E No.:BCTC/RF-EMC-005 Page 2 of 29 Edition:B.2 FCC ID: 2BHMG-T33B The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Power Pod Max Trademark: N/A Model/Type Reference: T33B Prepared For: Shunhetai (Shenzhen) Technology Co., Ltd. Address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajiang Road, Xitou, Songgang Street, Bao’an, Shenzhen, China Manufacturer: Shunhetai (Shenzhen) Technology Co., Ltd. Address: 201-302, 1th Building, Jiayu Environmental Protection Factory, No. 162, Shajiang Road, Xitou, Songgang Street, Bao’an, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2024-10-15 Sample Tested Date: 2024-10-15 to 2024-10-21 Issue Date: 2024-10-21 Report No.: BCTC2410515911-1E Test Standards: FCC Part15.209 ANSI C63.10-2013 Test Results: PASS Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2410515911-1E No.:BCTC/RF-EMC-005 Page 3 of 29 Edition:B.2 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 4 2. Test Summary ....................................................................................................... 5 3. Measurement Uncertainty ..................................................................................... 6 4. Product Information And Test Setup ..................................................................... 7 4.1 Product Information ............................................................................................... 7 4.2 Support Equipment ............................................................................................... 7 4.3 Test Setup Configuration ...................................................................................... 8 4.4 Test Mode ............................................................................................................. 9 5. Test Facility And Test Instrument Used ............................................................... 10 5.1 Test Facility ......................................................................................................... 10 5.2 Test Instrument Used .......................................................................................... 10 6. Conducted Emissions .......................................................................................... 12 6.1 Block Diagram Of Test Setup .............................................................................. 12 6.2 Limit .................................................................................................................... 12 6.3 Test procedure .................................................................................................... 12 6.4 EUT operating Conditions ................................................................................... 12 6.5 Test Result .......................................................................................................... 13 7. Radiated Emissions ............................................................................................. 15 7.1 Block Diagram Of Test Setup .............................................................................. 15 7.2 Limit .................................................................................................................... 16 7.3 Test procedure .................................................................................................... 16 7.4 Test Result .......................................................................................................... 17 8. Bandwidth Test .................................................................................................... 23 8.1 Test Procedure ................................................................................................... 23 8.2 Test Setup ........................................................................................................... 23 8.3 Test Result .......................................................................................................... 24 9. Antenna Requirements ........................................................................................ 25 9.1 Limit .................................................................................................................... 25 9.2 Test Result .......................................................................................................... 25 10. EUT Photographs ................................................................................................ 26 11. EUT Test Setup Photographs.............................................................................. 27 (Note: N/A Means Not Applicable) Report No.: BCTC2410515911-1E No.:BCTC/RF-EMC-005 Page 4 of 29 Edition:B.2 1. Version Report No. Issue Date Description Approved BCTC2410515911-1E 2024-10-21 Original Valid Report No.: BCTC2410515911-1E No.:BCTC/RF-EMC-005 Page 5 of 29 Edition:B.2 2. Test Summary The Product has been tested according to the following specifications: No. Test Parameter Clause No. Results 1 Conducted Emission 15.207 PASS 2 Radiated Emission 15.209 PASS 3 20dB…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted emissions Radiated Measurement Photos 9kHz-30MHz 30MHz-1GHz

Contact Information

Applicant

Gary Ye
[email protected]13423732628Fax: /

Technical Contact

Shenzhen BCTC Testing Co., Ltd.Alan Mei
[email protected]+86-755-36882589

1-2/F., Building B, Pengzhou Industrial Park, · Bao'an District, Dongguan City, Guangdong Provinc · China

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
215C0.36 MHz - 0.36 MHz-
Confidentiality
Long Term

Other Applications from Shunhetai (Shenzhen) Technology Co., Ltd.

Magnetic Wireless Power Bank - FCC ID 2BHMG-T8 - Shunhetai (Shenzhen) Technology Co., Ltd.
2BHMG-T8

Magnetic Wireless Power Bank

Sep 17, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Wireless Power Bank - FCC ID 2BHMG-T16 - Shunhetai (Shenzhen) Technology Co., Ltd.
2BHMG-T16

Magnetic Wireless Power Bank

Sep 17, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Wireless Power Bank - FCC ID 2BHMG-T11 - Shunhetai (Shenzhen) Technology Co., Ltd.
2BHMG-T11

Magnetic Wireless Power Bank

Sep 17, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Wireless Power Bank - FCC ID 2BHMG-T6 - Shunhetai (Shenzhen) Technology Co., Ltd.
2BHMG-T6

Magnetic Wireless Power Bank

Sep 17, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Wireless Power Bank - FCC ID 2BHMG-T3A - Shunhetai (Shenzhen) Technology Co., Ltd.
2BHMG-T3A

Magnetic Wireless Power Bank

Sep 17, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz