Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Digital China (China) Co., Ltd 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Digital China (China) Co., Ltd Address: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Product Name: Integrated Forklifts RFID Reader FCC ID: 2BHQW-YKFR Model(s): YKFR-2ESK,YKFR-3ESK,YKFR-2ESK Slim, YKFR-3ESK Slim,YKFR-2ESK Pro,YKFR-3ESK Pro 2.911(d)(5)(i) Equipment Type We, [Digital China (China) Co., Ltd] certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Dongdong Zhang Date: Aug.16, 2024 Title and Company name: Program Manager / Digital China (China) Co., Ltd NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Digital China (China) Co., Ltd 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List) Company name: Digital China (China) Co., Ltd Address: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Product Name: Integrated Forklifts RFID Reader FCC ID: 2BHQW-YKFR Model(s): YKFR-2ESK,YKFR-3ESK,YKFR-2ESK Slim, YKFR-3ESK Slim,YKFR-2ESK Pro,YKFR-3ESK Pro 2.911(d)(5)(ii) Applicant filing We, [Digital China (China) Co., Ltd] certify that, as of the date of the filing of the application, the applicant is not identified on the “Covered List” NOTE 1 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Dongdong Zhang Date: Aug.16, 2024 Title and Company name: Program Manager / Digital China (China) Co., Ltd NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Digital China (China) Co., Ltd 2.911 (d)(7)USA Agent v1.5 Section 2.911(d)(7) USA Agent for Service of Process Company name: Digital China (China) Co., Ltd Address: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Product Name: Integrated Forklifts RFID Reader FCC ID: 2BHQW-YKFR Model(s): YKFR-2ESK,YKFR-3ESK,YKFR-2ESK Slim, YKFR-3ESK Slim,YKFR-2ESK Pro,YKFR-3ESK Pro 2.911(d)(7) USA Designated Agent for Service of Process We, [ Digital China (China) Co., Ltd] (“the applicant”) designate [Electronic Mac, Inc.] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Electronic Mac, Inc. USA Address: 6525 Crown Blvd, # 20805, San Jose, CA 95120 FRN Number: 0033414541 Contact Name: Ray Sia Telephone No: 408-332-2399 Email: [email protected] Applicant Company name: Digital China (China) Co., Ltd Address: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Grantee FRN Number: 0035707967 FCC Grantee Code: 2BHQW Contact Name: Dongdong Zhang Telephone No: 18520825668 Email: [email protected] Signature: Title: Manger Signature: Digital China (China) Co., Ltd 2.911 (d)(7)USA Agent v1.5 Title: Program Manager Date: Aug.16, 2024 Date: Aug.16, 2024 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
Digital China (China) Co., Ltd Agent Authorization Company: Digital China (China) Co., Ltd Address: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Product Name: Integrated Forklifts RFID Reader Model Number(s): YKFR-2ESK,YKFR-3ESK,YKFR-2ESK Slim, YKFR-3ESK Slim,YKFR-2ESK Pro,YKFR-3ESK Pro Product Description: Integrated Forklifts RFID Reader We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Aug.16, 2024 Name: Dongdong Zhang Title: Program Manager Company: Digital China (China) Co., Ltd
Digital China (China) Co., Ltd Family models declaration letter. Date: August 16, 2024 We Digital China (China) Co., Ltd Of No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Product: Integrated Forklifts RFID Reader Model Name: YKFR-2ESK,YKFR-3ESK,YKFR-2ESK Slim, YKFR-3ESK Slim,YKFR-2ESK Pro,YKFR-3ESK Pro Difference description of series models: All the model are the same circuit and RF module, except the model names and colors Thanks Sincerely Signature Name: Dongdong Zhang Date: Aug.16, 2024 Title: Program Manager
Digital China (China) Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 16, 2024 Subject; Request for Confidentiality FCC ID: 2BHQW-YKFR To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Dongdong Zhang Title: Program Manager
1 / 1 铭牌长50mm 宽40mm Label
FCC ID: 2BHQW-YKFR RF Exposure Evaluation Limits According to 447498 D01 General RF Exposure Guidance v06 The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. FCC ID: 2BHQW-YKFR Test Result of RF Exposure Evaluation The source of the evaluation data results is based on the test report ET-24070885E01/02 BT Antenna gain=0.00dBi RFID Antenna gain=-1dBi/5.82dBi FOR BLE Mode Output power (dBm) Output power (mW) Numeric antenna gain Power Density at R=20cm (mW/cm2) Limit (mW/cm2) Result GFSK 0.96 1.25 1.00 0.00025 1.0 PASS FOR RFID ANT1 Fre.(GHz) Output power (dBm) Output power (mW) Numeric antenna gain Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 0.91525 22.04 159.96 0.79 0.02515 1.0 PASS FOR RFID ANT2 Fre.(GHz) Output power (dBm) Output power (mW) Numeric antenna gain Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 0.92725 22.21 166.34 3.82 0.12650 1.0 PASS FOR RFID ANT3 Fre.(GHz) Output power (dBm) Output power (mW) Numeric antenna gain Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 0.92725 22.46 176.20 3.82 0.13400 1.0 PASS If BT and RFID work simultaneously BLE+RFID, the total power density is 0.00025/1+0.02515/1+0.12650/1+0.13400/1=0.2859<1. Then SAR evaluation is not require .
SPECIFICATION FOR APPROVAL CUSTOMER CUSTOMER PART NO: DESCRIPTION NO. T757513 / 4dBi UHF RFID PRESENT DAY : 2020/06/13 DRAWING CUSTOMER APPROVE MADE CHECKED APPROVED Berry Boby Henry DATE:2020/06/13 DATE: ShenZhen Fuwit Technology Co., Ltd. ST-R03-10 www.fuwit.com ShenzhenQuanshunHongTechnologyCo,LtG .cn 400-833-1258 1.PUoGuctimages 2.PUoGuctapplicationaUeas T757513 itisauniveUsal4GBiciUculaUlypolaUizeGantennasuitablefoUUHF RFIDapplications,GesigneGusingthefouUaUmspiUalpUinciple,withgooGfUont tobackUatioanGexcellentwiGebeamciUculaUlypolaUizeGchaUacteUistics ThisantennahasawiGefUequencyUange,smallsize,lightweight,highgain,low stanGingwave,gooGGiUectionalsymmetUy,anGlowaxialUatioItcanbe convenientlyapplieGtoUHFbanGRFIDhanGhelGGevices,compactsmallall-in-one Gevices,anGotheUequipment 3.TechnicalpaUameteU: 902MHz~fUequencyUange(MHz)928MHz PolaUizationmoGe CiUculaUpolaUization >gain(dBi)4dBi <AxisUatio(dB)3dB H - f a c e HPBW 120° E- f a c e HPBW 120° impeGance(Ω)50Ω Voltagestandingwave ratio(VSWR)≤1.3:1 IPEX、MMCX、SMATypeofconnectoUOptional Jointposition Si d e fee d 75mm×75mm×1PUoGuctsize(mm)3mm 2 weight 7g colouU g r een InstallationmethoG Sc r ew fixation o r a d hesive backing -40°C ~+working temperature (°C)85°C www.fuwit.com.cn 400-833-1258 902Mhz ~ 928Mhz G 4. Darkroom testing 3D Gain & Efficiency ain H-face d i r ectional d iag r am (ho r izontal lobe d i r ectional d iag r am) E-face Directional diagram (vertical lobe directional diagram) www.fuwit.com.cn 400-833-1258 Retu r n loss 928 MHz:-29.4dB 922 MHz:-24.7dB 915 MHz:-27.4dB 902 MHz:-21.7dB dB(S11) -15 -20 -25 -30 -35 -40 -45 930925 920915910905900 FREQ(MHz) Voltagestan d ing wave r atio VSW R 928 MHz:1.07 922 MHz:1.12 915 MHz:1.09 902 MHz:1.18 FREQ (MHz) VSWR 8 7 6 5 4 3 2 1 930925920915910905900 www.fuwit.com.cn 400-833-1258 5、Product structure size parameters ape r tu r e thickness
CUSTOMER SPECIFICATION FOR APPROVAL T182004 CUSTOMER PART NO: DESCRIPTION NO . PRESENT DAY : 2014-12-6 DRAWING CUSTOMER APPROVE MADECHECKEDAPPROVED DenceBobyHenry DATE: 2014.12.6 DATE: Shenzhen Fuwit Technology Co., Ltd. :ST-R03-10 UHFRFIDReaderMicrostripCeramicsAntenna PRODUCTSPECIFICATION T182004 FEATURES UHFRFIDReaderCircularPolarizationAntenna MicrostripceramicsAntennawithRHCP Smallantennaelement LowWeight,CompactSize Lowinteractionwithplatform Negligibledetuningclosetousers EasyapplicationandSavedevelopmenttime SPECIFICATIONS 1OperatingFrequency(MHz) 922.5MHz±2MHz 2V.S.W.R1.5:1 3TypeMicrostripCeramicsAntenna 4BandWidth(MHz)>4.0 5PeakGain(dBic)-1 6PolarizationRHCP 7AxialRatio(db)<2.0 ■DIMENSIONS ■Radiationpattern
Report No.: ET-24070885E01 This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen ETR Standard Technology Co., Ltd. TEST REPORT Applicant: Digital China (China) Co., Ltd Address of Applicant: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Manufacturer: Digital China (China) Co., Ltd Address of Manufacturer: No. 304, 3rd Floor, No. 9 Shangdi 9th Street, Haidian District, Beijing Product Name: Integrated Forklifts RFID Reader Model No.: YKFR-2ESK,YKFR-3ESK,YKFR-2ESK Slim, YKFR-3ESK Slim,YKFR-2ESK Pro,YKFR-3ESK Pro Trade Mark: FCC ID: 2BHQW-YKFR Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.249 Date of Test: Jul.11,2024-Aug.24,2024 Date of report issued: Aug.25,2024 Remark: The results shown in this test report refer only to the sample(s) tested , this test report cannot be reproduced, except in full without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver Prepared By Shenzhen ETR Standard Technology Co., Ltd. Address: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Compiled by: Reviewed by: Approved by: Project Engineer Project Manager Authorized Signature - Page 2 of 46 - Report No.: ET-24070885E01 Report Revision History Report No. Description Issue Date ET-24070885E01 Original Aug.25,2024 - Page 3 of 46 - Report No.: ET-24070885E01 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Contents Page 1 TEST SUMMARY ......................................................................................................................................4 2 GENERAL INFORMATION .......................................................................................................................5 2.1 GENERAL DESCRIPTION OF EUT ..........................................................................................................5 2.2 TEST MODE .........................................................................................................................................7 2.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................................7 2.4 DEVIATION FROM STANDARDS ..............................................................................................................7 2.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................7 2.6 TEST FACILITY.....................................................................................................................................7 2.7 TEST LOCATION...................................................................................................................................7 2.8 ADDITIONAL INSTRUCTIONS ..................................................................................................................7 3 TEST INSTRUMENTS LIST ......................................................................................................................8 4 TEST RESULTS AND MEASUREMENT DATA .......................................................................................9 4.1 ANTENNA REQUIREMENT ......................................................................................................................9 4.2 CONDUCTED EMISSIONS ....................................................................................................................10 4.3 CONDUCTED PEAK OUTPUT POWER ...................................................................................................11 4.4 20DB EMISSION BANDWIDTH ..............................................................................................................13 4.5 CARRIER FREQUENCIES SEPARATION .................................................................................................17 4.6 HOPPING CHANNEL NUMBER .............................................................................................................21 4.7 DWELL TIME ......................................................................................................................................23 4.8 BAND EDGE.......................................................................................................................................26 4.8.1 Conducted Emission Method ......................................................................................................26 4.8.2 Radiated Emission Method .........................................................................................................33 4.9 SPURIOUS EMISSION .........................................................................................................................34 4.9.1 Conducted Emission Method ......................................................................................................34 4.9.2 Radiated Emission Method .........................................................................................................38 5 TEST SETUP PHOTO .............................................................................................................................46 6 EUT CONSTRUCTIONAL DETAILS .......................................................................................................46 - Page 4 of 46 - Report No.: ET-24070885E01 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 1 Test Summary Test Item Section in CFR 47 Result Test by Antenna Requirement 15.203/15.247 (c) Pass / AC Power Line Conducted Emission 15.207 NA/ / Conducted Peak Output Power …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902 MHz - 928 MHz | 176.20 mW |