Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AIRSPOT PTY LTD Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 8/19/2024 U.S. Agent Designation A IRSPOT PTY LTD acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BHSX-A1): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of AIRSPOT PTY LTD. AIRSPOT PTY LTD with the FRN 0035723105 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature Robert Hackett Founder AIRSPOT PTY LTD Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
AIRSPOT PTY LTD. To: Federal Communications Commission Date: 2024/08/20 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) AIRSPOT PTY LTD. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) AIRSPOT PTY LTD. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [ is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification: AIRSPOT FCC ID: 2BHSX-A1 If you have any questions, please feel free to contact me. Contact Person: Robert Hackett Position in the Company: Founder Date of Signature: 2024/08/20 ___________________________ Signatory (signature of the applicant)
AIRSPOT PTY LTD. Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Date: 20 August 2024 Product Certification Königswinkel 10 D 32825 Blomberg FCC ID: 2BHSX-A1 To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☒ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☒ for an initial period of 180 days ☐ until: ☐ not applicable ☒ External Photos ☒ Test Setup Photos ☒ Internal Photos ☒ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Signatory Printed Name: Robert Hackett Position: Founder
Page1of1FCCID:2BHSX-A1 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L3.0cmxW2.0cm) LabelLocation AIRSPOT Model:A1 FCCID:2BHSX-A1
Page1of4FCCID:2BHSX-A1 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID:2BHSX-A1 Productname:AIRSPOT TestModel:A1 PowerSupply: Input:5V1A DC3.7Vby552223Battery,300mAh HardwareVersion:2024-5-17 SoftwareVersion1.1.0 Bluetooth:2402MHz~2480MHz ChannelNumber:79channelsforBluetooth7.2.0(DSS) 40channelsforBluetooth7.2.0(DTS) ChannelSpacing:1MHzforBluetooth7.2.0(DSS) 2MHzforBluetooth7.2.0(DTS) ModulationType:GFSK,π/4-DQPSKforBluetooth7.2.0(DSS) GFSKforBluetooth7.2.0((DTS) BluetoothVersion:7.2.0 AntennaType:PCBAntenna AntennaGain:-1.04dBi Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:PortableDevice 2.EvaluationmethodandLimit AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSAR testexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDB procedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulation exposureconditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition,listedbelow,issatisfied.Thesetest exclusionconditionsarebasedonsource-basedtime-averagedmaximumconductedoutputpower oftheRFchannelrequiringevaluation,adjustedfortune-uptolerance,andtheminimumtest separationdistancerequiredfortheexposureconditions.22Theminimumtestseparationdistance isdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresoroutersurfaceof thedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements,toany partofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbythe operatingconfigurationsandexposureconditionsofthetransmitterandapplicablehostplatform requirements,typicallyintheSARmeasurementorSARanalysisreport,accordingtotherequired publishedRFexposureKDBprocedures.WhennootherRFexposuretestingorreportingis required,astatementofjustificationandcompliancemustbeincludedintheequipmentapproval,in lieuoftheSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfiedbefore applyingtheseSARtestexclusionprovisions;forexample,handheldPTTtwo-wayradios,handsets, laptops&tabletsetc.“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: Page2of4FCCID:2BHSX-A1 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportablehost platformexposureconditions.ThegranteeisresponsiblefordocumentingthisaccordingtoClassI permissivechangerequirements.AntennasthatqualifyforstandaloneSARtestexclusionmust applytheestimatedstandaloneSARtodeterminesimultaneoustransmissiontestexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantennaconfiguration, adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≤1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≤0.04,andthe[∑ofMPEratios]is≤ 1.0. 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortableDevices RFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices Page3of4FCCID:2BHSX-A1 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.ConductedPowerResults <BT> ModeChannel Frequency(MHz)PeakConductedOutputPower(dBm) GFSK 02402 0.2 3924410.24 782480 0.14 [BLE1M] ModeChannel Frequency (MHz) PeakConductedOutputPower (dBm) GFSK 024020.08 1924400.1 3924800 [BLE2M] ModeChannel Frequency (MHz) PeakConductedOutputPower (dBm) GFSK 024020.5 1924400.59 3924800.58 5.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 [BLE1M] GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 [BLE2M] GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 Page4of4FCCID:2BHSX-A1 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.EvaluationResults 6.1StandaloneEvaluation Band/Mode f (GHz) Antenna Distance (mm) RFoutputpower SARTest Exclusion Threshold SARTest Exclusion dBmmW BT GFSK 2.48 5 1.0 1.25890.3965<3.0Yes π/4DQPS…
Text truncated - open the document above for the full version.
深圳市亿圣邦科技有限公司 1 TestReport Applicant : ShenzhenYishengbangTechnologyCo.,LtdAntenna Productname : PCBantenna Modelname : TB3106 Address:437/34GlenferrieDriveRobinaQueensland4226Australia 1.ProductOverview 深圳市亿圣邦科技有限公司 2 2.TestResult 深圳市亿圣邦科技有限公司 3 BTAntennaVSWR 2.TestResult 深圳市亿圣邦科技有限公司 4 BTAntennaGain/Efficiency/3DDATA 2.TestResult 深圳市亿圣邦科技有限公司 5 2.TestResult 深圳市亿圣邦科技有限公司 6 BTAntennaGain/Efficiency/3DDATA 2.TestResult 深圳市亿圣邦科技有限公司 7 BTAntennaGain/Efficiency/3DDATA 2.TestResult 深圳市亿圣邦科技有限公司 8 BTAntennaGain/Efficiency/3DDATA 3.Conclusions 8 深圳市亿圣邦科技有限公司 谢谢!
Page 1 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBT(ConductedMeasurement) ProductName:AIRSPOT TestModel:A1 EnvironmentalConditions Temperature: 23.8C RelativeHumidity:52.1% ATMPressure:100.0kPa TestEngineer:JerryChu Supervisedby:NickPeng Page 2 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-20dBBandwidth ConditionModeFrequency(MHz)Antenna-20dBBandwidth(MHz)Limit-20dBBandwidth(MHz)Verdict NVNT1-DH52402Ant10.949N/APass NVNT1-DH52441Ant10.946N/APass NVNT1-DH52480Ant10.947N/APass Page 3 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page 4 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 Page 5 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNT1-DH52402Ant10.200.221Pass NVNT1-DH52441Ant10.2400.2421Pass NVNT1-DH52480Ant10.1400.1421Pass Page 6 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page 7 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT1-DH52480MHzAnt1 Page 8 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3CarrierFrequenciesSeparation ConditionModeAntennaHoppingFreq1(MHz)HoppingFreq2(MHz)HFS(MHz)Limit(MHz)Verdict NVNT1-DH5Ant12402.0162402.9920.9760.633Pass Page 9 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs CFSNVNT1-DH52402MHzAnt1 Page 10 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.4DwellTime ConditionModeFrequency (MHz) AntennaPulseTime (ms) TotalDwellTime (ms) Burst Count PeriodTime (ms) Limit (ms) Verdict NVNT1-DH52402Ant12.878267.6549331600400Pass Page 11 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs DwellNVNT1-DH52402MHzAnt1OneBurst DwellNVNT1-DH52402MHzAnt1Accumulated Page 12 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.5NumberofHoppingChannel ConditionModeAntennaHoppingNumberLimitVerdict NVNT1-DH5Ant17915Pass Page 13 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs HoppingNo.NVNT1-DH52402MHzAnt1 Page 14 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.6BandEdge ConditionModeFrequency(MHz)AntennaHoppingModeMaxValue(dBc)Limit(dBc)Verdict NVNT1-DH52402Ant1No-Hopping-43.83-20Pass NVNT1-DH52480Ant1No-Hopping-55.89-20Pass Page 15 of 29 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd…
Text truncated - open the document above for the full version.
Page 1 of 36 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR AIRSPOTPTYLTD AIRSPOT TestModel:A1 Preparedfor:AIRSPOTPTYLTD Address:437/34GlenferrieDriveRobinaQueensland4226Australia Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:June03,2024 Numberoftestedsamples:2 SampleNo.:A240628117-1,A240628117-2 Serialnumber:Prototype DateofTest:June03,2024~July16,2024 DateofReport:July17,2024 Page 2 of 36 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA07014159EA DateofIssue.......................................:July17,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:AIRSPOTPTYLTD Address................................................:437/34GlenferrieDriveRobinaQueensland4226Australia TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:TRF-4-E-148A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:AIRSPOT TradeMark..........................................:AirSpot TestModel...........................................:A1 Ratings.................................................: Input:5V1A DC3.7Vby552223Battery,300mAh Result..................................................:Positive Compiledby:Supervisedby:Approvedby: JokerHu/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 36 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA07014159EA July17,2024 Dateofissue TestModel.............................. : A1 EUT......................................... : AIRSPOT Applicant...............................:AIRSPOTPTYLTD Address...................................:437/34GlenferrieDriveRobinaQueensland4226Australia Telephone...............................: / Fax..........................................:/ Manufacturer.........................: AIRSPOTPTYLTD Address...................................:437/34GlenferrieDriveRobinaQueensland4226Australia Telephone...............................: / Fax..........................................:/ Factory...................................: AIRSPOTPTYLTD Address...................................:437/34GlenferrieDriveRobinaQueensland4226Australia Telephone...............................:/ Fax..........................................:/ Page 4 of 36 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July17,2024InitialIssue--- Page 5 of 36 FCCID:2BHSX-A1ReportNo.:LCSA07014159EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION..........................................................................................................6 1.1DescriptionofDevice(EUT)................................................................................................................6 1.2SupportequipmentList.........................................................................................................................7 1.3ExternalI/OCable.................................................................................................................................7 1.4DescriptionofTestFacility...................................................................................................................7 1.5StatementoftheMeasurementUncertainty.......................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |