FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. BEDGEAR LLC/
  3. 2BHT9BG102

2BHT9BG102Control Box

BEDGEAR LLC

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 16, 2026
Application Purpose
Original Equipment
Equipment Note
Control Box
Frequency Range
2402.00000000 - 2480.00000000
Company
BEDGEAR LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Control Box MODEL NUMBER: BG102 FCC ID: 2BHT9BG102 REPORT NUMBER: 4792059993-1-RF-2-V2 ISSUE DATE: January 9, 2026 Prepared for BEDGEAR LLC 200 Sea Lane Farmingdale NY 11735 USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792059993-1-RF-2-V2 Page 2 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 January 9, 2026 Initial Issue V1 February 12, 2026 Updated section 4 Fanny Huang V2 February 13, 2026 Tune up updated. Fanny Huang REPORT NO.: 4792059993-1-RF-2-V2 Page 3 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS .................................................................................... 4 2. TEST METHODOLOGY ........................................................................................................ 5 3. FACILITIES AND ACCREDITATION .................................................................................... 5 4. REQUIREMENT .................................................................................................................... 6 REPORT NO.: 4792059993-1-RF-2-V2 Page 4 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: BEDGEAR LLC Address: 200 Sea Lane Farmingdale NY 11735 USA Manufacturer Information Company Name: BEDGEAR LLC Address: 200 Sea Lane Farmingdale NY 11735 USA EUT Information EUT Name: Control Box Model: BG102 Brand: BEDGEAR Sample Received Date: December 12, 2025 Sample Status: Normal Sample ID: 9239714 Date of Tested: January 4, 2026 to January 9, 2026 APPLICABLE STANDARDS STANDARD TEST RESULTS 447498 D04 Interim General RF Exposure Guidance v01 PASS Prepared By: Checked By: Fanny Huang Kebo Zhang Project Engineer Operations Leader Approved By: Stephen Guo Operations Manager REPORT NO.: 4792059993-1-RF-2-V2 Page 5 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR FCC Part 1 Subpart I, section 1.1307 and KDB 447498 D04 Interim General RF Exposure Guidance v01. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note 1: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. Note 3: For below 30 MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. And these measurements below 30 MHz had been correlated to measurements performed on an OFS. REPORT NO.: 4792059993-1-RF-2-V2 Page 6 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIMIT AND CALCULATION METHOD According to 447498 D04 Interim General RF Exposure Guidance v01, 2.1.4 MPE-Based Exemption An alternative to the SAR-based exemption is provided in § 1.1307(b)(3)(i)(C), for a much wider frequency range, from 300 kHz to 100 GHz, applicable for separation distances greater or equal to λ/2π, where λ is the free-space operating wavelength in met…

Text truncated - open the document above for the full version.

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART C ISED RSS-247 Issue 4 TEST REPORT For Control Box MODEL NUMBER: BG102 REPORT NUMBER: 4792059993-1-RF-1-V2 ISSUE DATE: January 9, 2026 FCC ID:2BHT9BG102 IC:32777-BG102 Prepared for BEDGEAR LLC 200 Sea Lane Farmingdale NY 11735 USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792059993-1-RF-1-V2 Page 2 of 89 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 January 9, 2026 Initial Issue V1 February 12, 2026 Updated page 15 Fanny Huang V2 February 13, 2026 Updated page 15 and AV power added Fanny Huang REPORT NO.: 4792059993-1-RF-1-V2 Page 3 of 89 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) RSS-GEN Clause 6.8 Pass AC Power Line Conducted Emission ANSI C63.10-2020, Clause 6.2 FCC Part 15.207 RSS-GEN Clause 8.8 Pass Conducted Output Power ANSI C63.10-2020, Clause 11.9.1.2 FCC Part 15.247 (b)(3) RSS-247 Clause 6.3.2 Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2020, Clause 11.8.1 FCC Part 15.247 (a)(2) RSS-247 Clause 6.3.1 (a) RSS-Gen Clause 6.7 Pass Power Spectral Density ANSI C63.10-2020, Clause 11.10.2 FCC Part 15.247 (e) RSS-247 Clause 6.3.1 (b) Pass Conducted Band edge and spurious emission ANSI C63.10-2020, Clause 11.11 FCC Part 15.247(d) RSS-247 Clause 6.6 Pass Radiated Band edge and Spurious Emission ANSI C63.10-2020, Clause 11.12 FCC Part 15.247 (d) FCC Part 15.205/15.209 RSS-247 Clause 6.6 RSS-GEN Clause 8.9 Pass Duty Cycle ANSI C63.10-2020, Clause 11.6 None; for reporting purposes only. Pass Note: 1. For ISED, it’s also performed according to ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 standards. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <FCC 47 CFR PART 15 SUBPART C ISED RSS-247 Issue 4> when <Simple Acceptance> decision rule is applied. REPORT NO.: 4792059993-1-RF-1-V2 Page 4 of 89 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ...................................................................................... 6 2. TEST METHODOLOGY .......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ...................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ..................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ............................................................ 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................. 8 5. EQUIPMENT UNDER TEST .................................................................................................... 9 5.1. DESCRIPTION OF EUT ............................................................................................. 9 5.2. CHANNEL LIST .......................................................................................................... 9 5.3. MAXIMUM POWER .................................................................................................... 9 5.4. TEST CHANNEL CONFIGURATION ....................................................................... 10 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 10 5.6. DESCRIPTION OF AVAILABLE ANTENNAS .......................................................... 10 5.7. SUPPORT UNITS FOR SYSTEM TEST .................................................................. 11 6. MEASURING EQUIPMENT AND SOFTWARE USED ......................................................... 12 7. ANTENNA PORT TEST RESULTS ...................................................................................... 15 7.1. CONDUCTED OUTPUT POWER ............................................................................ 15 7.2. 6DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ........................................ 16 7.3. POWER SPECTRAL DENSITY ............................................................................... 18 7.4. CONDUCTED BAND EDGE AND SPURIOUS EMISSION...................................... 20 7.5. DUTY CYCLE ........................................................................................................... 22 8. RADIATED TEST RESULTS ................................................................................................ 23 8.1. RESTRICTED BANDEDGE ..................................................................................... 31 8.2. SPURIOUS EMISSIONS(1 GHZ~3 GHZ) .........................................…

Text truncated - open the document above for the full version.

Test Report

1 电连技术股份有限公司 http://www.ectsz.com 用科技改变生活 Changing life with science and technology Antenna Evaluation Report Onboard Bluetooth Antenna & 2024.03.20 Issued By Wu Yujie Approved By Fu Feng ID & Reversion P0 2 电连技术股份有限公司 http://www.ectsz.com Summar y Antenna Picture Matching Network Test Method and Requirement Testing equipment List Testing Configuration Testing environment The definition of coordinate system Results Re s u l t s – V S W R Re s u l t s – E f f i c i e n c y a n d G a i n Ta b l e Re s u l t s – 2 D a n d 3 D R a d i a t i o n Pa t t e r n Conclusion Design histor y Index 3 电连技术股份有限公司 http://www.ectsz.com Summary 1. Antenna operating frequency band:2400-2500MHz 2. Antenna types: PCB On-board Antenna 3. The following data is the test report。 4 电连技术股份有限公司 http://www.ectsz.com Antenna Picture Antenna please refer to the internal photos. 5 电连技术股份有限公司 http://www.ectsz.com Matching Network Matching Circuits E2 Antenna RF Module E1 E3 Element Value E1 E2 E3 NC NC NC 6 电连技术股份有限公司 http://www.ectsz.com Test Method and Requirement Test Description Test Method Test Requirement VSWR The antenna is located on the RF motherboard, which is placed inside the machine, After calibrating the Agilent E5071C, use the RF cable to connect the whole machine to the Agilent E5071C for measurement. 2400~2500MHz<2.0 Efficiency The antenna is located on the RF motherboard, which is placed inside the machine, then, put the whole machine in the Microwave Anechoic Chamber Test System for testing. Follow the picture on page 11 shows the test status of the antenna been put in the microwave anechoic chamber. 2400~2500MHz>60% Gain 2400~2500MHz>2.5dBi 7 电连技术股份有限公司 http://www.ectsz.com Testing equipment List Test Description Test Equipment Test Software Equipment Model Diagram Calibration Date VSWR Agilent E5071C Network Analyzer E5071C 2023-06-25 N/A 8 电连技术股份有限公司 http://www.ectsz.com Test Description Test Equipment Test Software Equipment Model Diagram Calibration Date Passive test (Efficiency & Gain & Radiation Pattern) Microwave Anechoic Chamber SATIMO- SG24 2024-01-18 PMS (Passive Measurement System) Testing equipment List 9 电连技术股份有限公司 http://www.ectsz.com Testing equipment List Test Description Test Equipment Test Software Equipment Model Diagram Calibration Date Passive test (Efficiency & Gain & Radiation Pattern) Agilent E5071C Network Analyzer E5071C 2023-06-25 PMS ( Passive Measurement System) 10 电连技术股份有限公司 http://www.ectsz.com Testing Configuration DUT ANT PROBE 1~23 POWER(UPS) PC TESTER PASSIVE Agilent E5071C Network Analyzer SWITCH TESTER ACTIVE USB GPIB GPIB I O O I OUT IN OUT IN PASSIVE OUT ACTIVE OUT Control the work of probe1~23 Date collected by probe1~23 Issue control commands Assign values to the PC :The direction of the signal during the Passive Test TX RX (Components inside Microwave Anechoic Chamber) 11 电连技术股份有限公司 http://www.ectsz.com Testing environment Position in the chamber during the test Test setup photo: please refer to the antenna setup photo. 12 电连技术股份有限公司 http://www.ectsz.com The definition of coordinate system The coordinate system of chamber 13 电连技术股份有限公司 http://www.ectsz.com Results – VSWR Frequency VSWR Before Optimization After Optimization 2400MHz-2500MHz <4.0 <2.0 Before Optimization After Optimization 14 电连技术股份有限公司 http://www.ectsz.com Results – Efficiency and Gain Table Before Optimization After Optimization Frequency Efficiency (%) Gain(dBi) Efficiency (%) Gain(dBi) 2400MHz 39% 0.60 68% 2.63 2410MHz 38% 0.63 66% 2.74 2420MHz 43% 1.02 68% 2.79 2430MHz 45% 1.35 67% 2.81 2440MHz 44% 1.28 65% 2.65 2450MHz 45% 1.09 67% 2.55 2460MHz 46% 1.06 69% 2.57 2470MHz 50% 1.51 69% 2.62 2480MHz 54% 1.96 68% 2.69 2490MHz 55% 2.21 65% 2.69 2500MHz 53% 2.19 63% 2.73 AVG 47% 1.36 67% 2.68 Test status: Complete machine testing 15 电连技术股份有限公司 http://www.ectsz.com Results – 2D and 3D Radiation Pattern Before Optimization After Optimization 2D 3D XOY YOZ XOZ XOY YOZ XOZ 16 电连技术股份有限公司 http://www.ectsz.com Conclusion D a te C o n c l u s i o n: Test status Frequency antenna VSWR Efficiency Gain Complete machine 2400MHz-2500MHz Before Optimization <4.0 47% 1.36dBi After Optimization <2.0 67% 2.68dBi T h e VS W R of t h e o r i g i n a l a n te n n a i s l e s s t h a n 4 . 0 a t 2400- 2 5 0 0 M H z . A f te r t h e a n te n n a i s o p t i m i z e d , t h e VS W R i s l e s s t h a n 2 . 0 , t h e E f f i c i e n c y i s g re a te r t h a n 6 0 % , a n d t h e G a i n i s g re a te r t h a n 2 . 5 d B i . 17 电连技术股份有限公司 http://www.ectsz.com Design History Date Action Designed by 2024.03.20 Active Evaluation Report Wu Yujie 18 电连技术股份有限公司 http://www.ectsz.com 电连通向世界 服务成就未来 END Address: Jinxiu Industrial Park, Xitian Community, Gongming Street, Guangming New District, Shenzhen TEL:0755-81735688 Fax:0755-81735699 Mail:[email protected] Web:http://www.ectsz.com

Contact Information

Applicant

Eugene Alletto(CEO)
[email protected]Fax: 631.414.7766

Technical Contact

BEDGEAR LLCEugene Alletto
[email protected]

200 Sea Lane · Farmingdale, 11735 · United States

Test Firm

UL Verification Services (Guangzhou) Co., Ltd.Stephen Guo
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz8.30 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.