2BHWD-700Tire pressure monitor

Shenzhen Baoan District Tesda Electronics Co., Ltd.
Tire pressure monitor - FCC ID 2BHWD-700 - Shenzhen Baoan District Tesda Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 10, 2024
Application Purpose
Original Equipment
Date of Application
Aug 07, 2024
Equipment Note
Tire pressure monitor
Frequency Range
433.92000000 - 433.92000000
Company
Shenzhen Baoan District Tesda Electronics Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: REP America LLC FRN: 0034192500 Contact Name: Ben XU Address: Address: 6510 S Academy Blvd, Ste A #523, Colorado Springs, CO 80906 Telephone No: 719 201 3314 Email: [email protected] Applicant: Company name: Shenzhen Baoan District Tesda Electronics Co., Ltd. Grantee code: 2BHWD FRN: 0035732981 FCC ID: 2BHWD-700 Contact Name: Kang Lixia Address: 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Telephone No: 13592917292 Fax No: / Email: [email protected] [Shenzhen Baoan District Tesda Electronics Co., Ltd. ] certifies that, as of the date of this filing of the application with the TCB, [REP America LLC] is our designated US agent for service of process for the above referenced FCC ID. [Shenzhen Baoan District Tesda Electronics Co., Ltd. ] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [REP America LLC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicantis aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/08/01 Applicant’s Name:Kang Lixia US Agent’s Name: Ben XU Title: PM Title: President Signature Signature

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Baoan District Tesda Electronics Co., Ltd. Grantee code: 2BHWD FRN: 0035732981 FCC ID: 2BHWD-700 Contact Name: Kang Lixia Address: 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Telephone No: 13592917292 Fax No: / Email: [email protected] i. [Shenzhen Baoan District Tesda Electronics Co., Ltd. ] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Baoan District Tesda Electronics Co., Ltd. ]] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not](as a specifically named entity or any of its subsidiaries or affiliates)identified on the Covered List as an entity producing “covered” equipment. Theapplicantmustsignthiscertification. [Shenzhen Baoan District Tesda Electronics Co., Ltd. ] (“the applicant”) certifies that, as of the date of the filing of theapplication, the applicant [is not] identified on the Covered List as an entity producing “covered”equipment . Date: 2024/08/01 Applicant’s Name:Kang Lixia Title: PM Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen Baoan District Tesda Electronics Co., Ltd. Company: Shenzhen Baoan District Tesda Electronics Co., Ltd. Address: 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Product Name: Tire pressure monitor Model Number: 700 FCC Identifier: 2BHWD-700 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: : Kang Lixia Date: 2024-08-01 Title: PM Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Shenzhen Baoan District Tesda Electronics Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-08-01 Subject: Request for Confidentiality FCC ID: 2BHWD-700 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ■☐ Schematics ■☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ■ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long‐Term Confidentiality may be permitted under special conditions (See II. LONG‐TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short‐Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Name: : Kang Lixia Date: 2024-08-01 Title: PM Signature of applicant:

External Photos

Page 1 of 4 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn FCC ID:2BHWD‐700 External Photos Page 2 of 4 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn Page 3 of 4 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn Label&location Page 4 of 4 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn

ID Label/Location Info

FCC ID LABELING AND LOCATION FCC ID Label FCC ID: 2BHWD-700 FCC ID Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Page 1 of 3 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn FCC ID: 2BHWD‐700 External Photos PCB Antenna Page 2 of 3 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn Page 3 of 3 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn

RF Exposure Info

FCC ID: 2BHWD-700 RF Exposure Evaluation According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1091,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation 433.92MHz Field strength =86.94dBuV/m @3m Ant gain =-22.23 dBi ;so Ant numeric gain= 0.01 So EIRP=86.94-95.2=-8.26dBm So a SAR test is not required Frequency MHz Output power to antenna (dBm) Target power W/tolera nce (dBm) Max Output power to antenna (dBm) Max Output power to antenna (mW) Power Density at R=20cm (mW/cm2) Limit (mW/c m2) Result 433.92 -8.26 -8±1 -7 0.200 0.0004 0.289 PASS

Test Report

Page 1 of 27 FCC TEST REPORT FCC ID:2BHWD-700 Product : Tire pressure monitor Model Name : 700 Brand : N/A Report No. : NCT24029472E Prepared for Shenzhen Baoan District Tesda Electronics Co., Ltd. 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Prepared by Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, People’s Republic of China TEL: 400-8868-419 FAX: 86-755-27790922 Report No.: NCT24029472E Page 2 of 27 1 TEST RESULT CERTIFICATION Applicant’s name : Shenzhen Baoan District Tesda Electronics Co., Ltd. Address : 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Manufacture's name : Shenzhen Baoan District Tesda Electronics Co., Ltd. Address : 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Product name : Tire pressure monitor Model name : 700 Standards : FCC CFR47 Part 15 Section 15.231 Test procedure : ANSI C63.10:2013 Date of test : Jul. 12, 2024- Jul. 26, 2024 Date of Issue : Jul. 26, 2024 This device described above has been tested by NCT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NCT, this document may be altered or revised by NCT, personal only, and shall be noted in the revision of the document. Test Engineer: Keven Wu / Engineer Technical Manager: Henry Wang / Manager Report No.: NCT24029472E Page 3 of 27 Table of Contents Page 1 TEST RESULT CERTIFICATION 2 2. SUMMARY OF TEST RESULTS 5 2.1 TEST FACILITY 6 2.2 MEASUREMENT UNCERTAINTY 6 3. GENERAL INFORMATION 7 3.1 GENERAL DESCRIPTION OF EUT 7 3.2 DESCRIPTION OF TEST MODES 8 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 3.4 DESCRIPTION OF SUPPORT UNITS 8 3.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 9 4. EMC EMISSION TEST 11 4.1 CONDUCTED EMISSION MEASUREMENT 11 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 11 4.1.2 TEST PROCEDURE 12 4.1.3 DEVIATION FROM TEST STANDARD 12 4.1.4 TEST SETUP 12 4.1.5 EUT OPERATING CONDITIONS 12 4.1.6 TEST RESULTS 12 THE EUT WITH DC 3.0V FORM BATTERY. SO THIS TEST ITEM NOT APPLICABLE 12 4.2 RADIATED EMISSION MEASUREMENT 13 4.2.1 RADIATED EMISSION LIMITS 13 4.2.2 TEST PROCEDURE 14 4.2.3 TEST SETUP 15 4.2.4 EUT OPERATING CONDITIONS 16 4.2.5 TEST RESULTS 16 5. BANDWIDTH TEST 20 5.1 APPLIED PROCEDURES / LIMIT 20 5.2 TEST PROCEDURE 20 5.3 DEVIATION FROM STANDARD 20 5.4 TEST SETUP 20 5.5 EUT OPERATION CONDITIONS 20 5.6 TEST RESULTS 21 6. CALCULATION OF AVERAGE FACTOR 22 7. TRANSMISSION CEASE TIME 25 7.1 APPLICABLE STANDARD 25 Report No.: NCT24029472E Page 4 of 27 Table of Contents Page 7.2 TEST PROCEDURE 25 7.3 DEVIATION FROM STANDARD 25 7.4 TEST SETUP 25 7.5 EUT OPERATION CONDITIONS 25 7.6 TEST RESULTS 25 8. ANTENNA REQUIREMENT 27 9. TEST SETUP PHOTO 27 Report No.: NCT24029472E Page 5 of 27 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.231) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.209,15.231b Fundamental &Radiated Spurious Emission Measurement PASS 15.231c Occupy Bandwidth PASS 15.203 Antenna Requirement PASS 15.231(a) Transmission cease time PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.: NCT24029472E Page 6 of 27 2.1 TEST FACILITY Site Description EMC Lab. : Accredited by CNAS, 2022-09-27 The certificate is valid until 2028.01.07 The Laboratory has been assessed and proved to be in compliance with CNAS-CL01:2006 (identical to ISO/IEC 17025:2017) The Certificate Registration Number is L8251 Designation Number: CN1347 Test Firm Registration Number: 894804 Accredited by A2LA, June 14, 2023 The Certificate Registration Number is 6837.01 Accredited by Industry Canada, November 09, 2018 The Conformity Assessment Body Identifier is CN0150 Company Number: 30806 Name of Firm : Shenzhen NCT Testing Technology Co., Ltd. Site Location : A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, People’s Republic of China 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 Paramete r Uncertainty RF output power, conducted ±1.0dB Power Spectral Density, conducted±2.2dB Radio Frequency ± 1 x 10 -6 Bandwidth ± 1.5 x 10 -6 Time ±2% Duty Cycle ±2% Te mperature ±1°C Humidity ±5% DC and low frequency voltages ±3% Conducted Emissions (150kHz~30MHz)3.64dB Radiated Emission(below 30MHz) ±4.02dB Radiated Emission(30MHz~1GHz)5.03dB Radiated Emission(1GHz~25GHz)4.74dB Remark: The coverage Factor (k=2), and measurement Uncertainty for a level of Confidence of 95% Report No.: NCT24029472E Page 7 of 27 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Product Name : Tire pressure monitor Model Name : 700 Sample ID : NCT24029472-001# Sample(s) Status: : Engineer sample Series Model : N/A Model Different.: : N/A Operating frequency : 433.92 MHz Type of Modulation : FSK Antenna installation : PCB Antenna Antenna Gain : -22.23dBi Power supply : 3.0Vd.c Report No.: NCT24029472E Page 8 of 27 3.2 DESCRIPTION OF TEST MODES For All Emission Final Test Mode Description Transmitting mode Keep the EUT in continuously transmitting mode Note: (1) Fully-charged battery is used during the test 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Conducted Emission Test Spurious emissions 3.4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during t…

Text truncated - open the document above for the full version.

Test Report

Antenna Specification Manufacture: Shenzhen Baoan District Tesda Electronics Co., Ltd. Address: 201, Building B, Shanggaotian Industrial Zone, Gushu Community, Xixiang Street, Bao'an District, Shenzhen Model Name: 700 ANT STANDARD(S) : IEEE Std 149‐2021 Test frequency band: 433.92MHz Antenna installation: PCB ANT Gain(dBi) Frequency Gain(dBi) 433.87MHz ‐22.24 433.92MHz ‐22.25 433.97MHz ‐22.23 Tes t Setup Photos Antenna Photo

Test Setup Photos

Page 1 of 1 Shenzhen NCT Testing Technology Co., Ltd. A101&2F B2, Fuqiao 6th Area, Xintian Community, Fuhai Street, Baoan District, Shenzhen, China Hotline: 400-8868-419 Fax: 86-755-27790922 http://www.ncttesting.cn FCC ID:2BHWD‐700 Test Photo

Contact Information

Applicant

Kang Lixia
[email protected]13592917292Fax: 13592917292

Technical Contact

Shenzhen NCT Testing Technology Co., Ltd.Brown lu
[email protected]

Shenzhen · China

Test Firm

SHENZHEN NCT TESTING TECHNOLOGY CO., LTD.Henry Wang
[email protected]0755-27790922

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.