Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Bello™ Home User Manual We meet at last. Explore our Capsules03Maintenance Clean the Water Tank 19 Safety Instructions05Clean the Machine Exterior19 Clean the Rubber Sleeve20 Mobile Application07 Auto-cleaning Cycle21 What’s in the Box09 Technical Specifications22 Buttons & Lights11 Troubleshooting23 Prepare your initial beverages Install or Replace the Filter14Return Policy25 Make Filtered Water16 Make Flavoured Drinks18Warranty26 Bello™ reserves the right to alter the product to enhance its reliability, functionality, or design. Images in the user manual may not precisely depict the product. Bello™ advises customers to reach out to customer service for further details. Summary Watch the tutorial video MATCHALEMON GINGERMANGO TURMERICBERRIES ANTIOXYDANTPEACH BLACK TEA MATCHA - GREEN TEA - LEMON Servings: 15 cups LEMON - GINGER - SEA SALT Servings: 18 cups MANGO - TURMERIC - LIME Servings: 15 cups BLACKCURRANT - VITAMIN C Servings: 15 cups PEACH - BLACK TEA FLAVOUR Servings: 15 cups WELLNESS ICED TEA Start your healthy hydration routine. There are moments when you desire a quick refreshment, and others when you prefer to take your time and savour. With Bello™, your hydration experience transforms into an exploration of flavours and styles inspired by the world. Discover the benefits of the Bello™ filter in the taste of your water, and let yourself be charmed by the perfect harmony of our natural flavour infusions. Our wide range of options offers you a refreshing and varied pleasure throughout the day. 3 54mg of natural caffeine MINT GREEN TEALIME CUCUMBERLEMON BLUEBERRYPEACH MANGOHIBISCUS CHERRY MINT - GREEN TEA FLAVOUR Servings: 15 cups LIME - CUCUMBER - WATER Servings: 50 cups LEMON - BLUEBERRY - WATER Servings: 50 cups PEACH - MANGO - WATER Servings: 50 cups HIBISCUS - CHERRY - WATER Servings: 50 cups 0 CALORIES HOW DOES THE CAPSULE WORK? RECYCLING ADDS TO THE FEEL-GOOD FACTOR Each capsule contains a concentrated blend. When inserted into the Bello™ machine, the capsule releases its contents, which are then diluted with filtered water to create a refreshing drink. Bello™ ensures precise mixing and optimal flavor, allowing you to enjoy a perfectly balanced beverage every time. Bello's multi-serving glass capsules are designed with sustainability in mind. After using the contents, recycle them according to your local recycling guidelines. These durable glass capsules can be reused multiple times, reducing waste and promoting eco-friendly practices. By recycling, you're helping to protect the environment while enjoying your favorite beverages. 4 General Safety Instructions - PLEASE READ CAREFULLY BEFORE USE – FOR HOUSEHOLD USE ONLY The device should only be operated by individuals who have read and understood these operating instructions and/or have been instructed in the operation of the device. This device can be used by children aged 8 years and older, as well as persons with reduced physical, sensory, or mental capabilities, or even those who lack experience and knowledge, provided they have been given supervision or instruction concerning the safe use of the device and understand the associated hazards. Children should not be allowed to operate with the device without the supervision of an adult. Cleaning and user maintenance should not be performed by children without supervision. Only perform activities described in this manual. Before each use, be alert of any unusual noise. Ensure that the device is working properly, as this could be the start of a malfunction that could lead to a dangerous situation. The Bello™ Home machine should only be used with accessories sold exclusively by Bello™. Unplug your Bello™ Home machine when cleaning it manually or changing the filter. Avoid unplugging it by pulling on the power cord, and never do so with wet hands. If the power cord is damaged, discontinue use of the device. A damaged power cord must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid hazards. Do not use abrasive sponges or cleaners. Only place parts of the machine in the dishwasher if explicitly indicated in this user manual. To prevent fire, electric shock, and injury, do not immerse the power supply cord, plugs, or the machine in water or other liquids. Only fill the water tank with clean water. Using other liquids will damage the product and pose additional safety risks. Do not overfill the water tank. Fill water only up to the "Max" line, and do not store food in the water tank. Do not fill the water tank with hot or boiling water. Do not invert the machine upside down. Always remove the water filter before transporting it in a vehicle. Never operate the machine without a properly fitted water filter. After the first use, always keep the machine connected to the power supply to allow it to run proper cleaning cycles. Avoid removing the water tank during operation or moving the machine while it is switched on. 5 Safety Instructions Environmental Conditions The Bello™ Home should only be operated in a dry, indoor environment. Use it in an upright position, on a flat, stable, and clean surface. Temperature range: 4 – 40°C Relative humidity: 40 – 60% Ensure the supporting surface can bear a minimum weight of 8kg. Avoid exposing the appliance to direct sunlight and keep it away from fireplaces or heaters. Do not use the machine outdoors. Checking the Appliance After removing the packaging, ensure the product is complete, undamaged, and that all accessories are included. Do not use the appliance if it shows visible damage. Contact us at bellowater.com for assistance. Power Supply Cord Instruction A short power supply cord is provided to minimize risks associated with becoming entangled in or tripping over a longer cord. Longer detachable power supply cords or extension cords may be used with caution. If using a long detachable power supply cord or extension cord: The marked electrical rating of the detachable power supply cord or extensio…
Text truncated - open the document above for the full version.
BelloWater Managenent Inc. 300-150 boul. de la Cote-Vertu Montreal, Quebec H4N1C6 Canada Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-8-29 To whom it may concern: We, BelloWater Managenent Inc., hereby certify that the equipment for which authorization is sought (FCC ID: 2BHWI-BELLOHOME) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Clement Bouland President BelloWater Managenent Inc. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03
BelloWaterManagenentInc. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 8/27/24 U.S.AgentDesignation BelloWaterManagenentInc.acknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatesto actastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2BHWI- BELLOHOME): NameandcompanyofU.S.agent:AmericasComplianceConsultingLLCdbaiCertifi PhysicalU.S.addressofagent:2445NEDivisionSt,ste202Bend,OR97703UnitedStates FRNofU.S.agent:0033399411 EmailaddressofU.S.agent:[email protected] AmericasComplianceConsultingLLCdbaiCertifiacknowledgestheirobligationtoacceptserviceofprocess onbehalfofBelloWaterManagenentInc.. BelloWaterManagenentInc.withtheFRN0035733211acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature ClementBouland President BelloWaterManagenentInc. Signature PaulAPreston President AmericasComplianceConsultingLLCdbaiCertifi 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-8-29> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BHWI-BELLOHOME Bello Home For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Clement Bouland /President Company: BelloWater Managenent Inc. Address: 300-150 boul. de la Cote-Vertu Montreal, Quebec H4N1C6 Canada Phone: +514 973 0502 Fax: E-Mail: [email protected]
BelloWater Managenent Inc. 300-150 boul. de la Cote-Vertu Montreal, Quebec H4N1C6 Canada Date: 2024-8-29 FCC ID: 2BHWI-BELLOHOME Model Number: Bello Home To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, BelloWater Managenent Inc., declare that this EUT (FCC ID: 2BHWI-BELLOHOME) doesn’t have Ad Hoc mode function on “non-US/Canada frequencies”. In addition. The frequency selection feature is disabled by firmware for devices marked to the US/Canada. For DTS part of this device, only channels 1-11 will be used in North America, Country code selection is disabled. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Name/Title: Clement Bouland /President Company: BelloWater Managenent Inc. Address: 300-150 boul. de la Cote-Vertu Montreal, Quebec H4N1C6 Canada Phone: +514 973 0502 Fax: E-Mail: [email protected]
BelloWater Managenent Inc. 300-150 boul. de la Cote-Vertu Montreal, Quebec H4N1C6 Canada Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-8-29 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BHWI-BELLOHOME including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Clement Bouland /President Company: BelloWater Managenent Inc. Address: 300-150 boul. de la Cote-Vertu Montreal, Quebec H4N1C6 Canada Phone: +514 973 0502 Fax: E-Mail: [email protected]
Page1of4FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7
Page1of1FCCID:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:8.0cmxW:4.95cm) LabelLocation L W
Page1of6FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of6FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 NFCAntenna Page3of6FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of6FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 WIFIANT Page5of6FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Page6of6FCC:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.10
Page 1 of 5 FCCID:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID:2BHWI-BELLOHOME EUT:BelloHome TestModel:BelloHome PowerSupply: ForACAdapter:Input:100-240V~,50/60Hz,1.0AMax Output:12V2.5A HardwareVersion:Home_Mainboard_Gerbers_V4.4 SoftwareVersion:V1.20 2.4GWLAN: FrequencyRange:2412MHz~2462MHz ChannelSpacing:5MHz ChannelNumber:11Channelsfor20MHzbandwidth(2412MHz~2462MHz) 7Channelsfor40MHzbandwidth(2422MHz~2452MHz) ModulationType:IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaDescription:InternalAntenna3.42dBi(Max.) NFC: OperatingFrequency:13.56MHz ModulationType:ASK AntennaDescription:InternalAntenna0dBi(Max.) Exposurecategory : Generalpopulation/uncontrolledenvironment EUTType : ProductionUnit DeviceType : MobileDevices Page 2 of 5 FCCID:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page 3 of 5 FCCID:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation CeramicsAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Note AntennaInternalAntenna2400MHz-2500MHz3.42dBiWIFiAntenna AntennaInternalAntenna13.56MHz0dBiNFCAntenna 6.ConductedPower [2.4GWLAN] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) IEEE802.11b 1 2412 15.18 6 2437 15.36 11 2462 15.67 IEEE802.11g 1 2412 14.56 6 2437 14.57 11 2462 14.53 IEEE802.11n HT20 1 2412 13.11 6 2437 13.74 11 2462 13.21 IEEE802.11n HT40 3 2422 12.16 6 2437 12.4 9 2452 12.61 Mode Frequency (MHz) Field Strength(dBuV/m@3m) ASK13.56MHz43.08 Note:NFC:dBuV/m=20loguV/m Page 4 of 5 FCCID:2BHWI-BELLOHOME ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 7.ManufacturingTolerance IEEE802.11b(Peak) ChannelChannel01Channel06Channel11 Target(dBm)15.015.015.0 Tolerance±(dB)1.01.01.0 IEEE802.11g(Peak) ChannelChannel01Channel06Channel11 Target(dBm)14.014.014.0 Tolerance±(dB)1.01.01.0 IEEE802.11n20(Peak) ChannelChannel01Channel06Channel11 Target(dBm)13.013.013.0 Tolerance±(dB)1.01.01.0 IEEE802.11n40(Peak) ChannelChannel03Channel06Channel09 Target(dBm)12.012.012.0 Tolerance±(dB)1.01.01.0 8.MeasurementResults 8.1StandaloneMPE AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast…
Text truncated - open the document above for the full version.
Prepared by: Xu Ying Approved by: Xu Kai TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 OTA TEST REPORT TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2021. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Applicant Espressif Systems Product ESP ANT B Model ESP ANT B Report No. Y2302A0204-T1 Issue Date March 22, 2023 OTA Test Report Report No: Y2302A0204-T1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 19 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. Test Laboratory .............................................................................................................................. 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test Facility ....................................................................................................................... 3 1.3. Testing Location ................................................................................................................ 3 1.4. Laboratory Environment .................................................................................................... 3 2. General Description of Equipment Under Test .............................................................................. 4 2.1. Applicant and Manufacturer Information ............................................................................ 4 2.2. General Information ........................................................................................................... 4 2.3. Test Date ........................................................................................................................... 4 2.4. Received Date ................................................................................................................... 4 2.5. Applied Standards ............................................................................................................. 5 3. Test Conditions .............................................................................................................................. 6 3.1. Test Configuration ............................................................................................................. 6 3.2. Test Measurement ............................................................................................................. 6 4. Test Results ................................................................................................................................... 7 4.1. Gain and Efficiency ............................................................................................................ 7 4.2. Voltage Standing Wave Ratio (VSWR) .............................................................................. 8 4.3. Antenna S11 ...................................................................................................................... 9 5. Equipment List ............................................................................................................................. 10 ANNEX A: 2-D Pattern Plots .................................................................................................................... 11 ANNEX B: The EUT Appearance and Test Configuration........................................................................ 17 B.1 EUT Appearance ................................................................................................................... 17 B.2 Test Configuration ................................................................................................................. 19 OTA Test Report Report No: Y2302A0204-T1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 19 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test Facility A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform measurement. 1.3. Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] 1.4. Laboratory Environment Temperature Min. =19°C,Max. = 25°C Relative humidity Min. =40%,Max. =72% Shield effect 0.7-6GHz > 100dB Ground resistance <0.5Ω OTA Test Report Report No: Y2302A0204-T1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 19 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment Under Test 2.1. Applicant and Manufacturer Information Applicant Name Espressif Systems Applicant address #101, Block 2, 690 Bibo Road, Zhang Jiang High-Tech Park, Shanghai, China Manufacturer Name Espressif Systems Manufacturer address #101, Block 2, 690 Bibo Road, Zhang Jiang High-Tech Park, Shanghai, China 2.2. General Information EUT Description Product N…
Text truncated - open the document above for the full version.
Page1 of 55FCCID:2BHWI-BELLOHOMEReportNo.: LCSA04014061EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity AppendixA RF Test Data for 2.4GWIFI(ConductedMeasurement) ProductName:Bello Home Test Model:Bello Home EnvironmentalConditions Temperature: 23.1C RelativeHumidity:52.3% ATM Pressure:100.0kPa Test Engineer:PaddiChen Supervisedby:Nick Peng Page2 of 55FCCID:2BHWI-BELLOHOMEReportNo.: LCSA04014061EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.1 -6dB Bandwidth ConditionModeFrequency(MHz)Antenna-6 dB Bandwidth(MHz)Limit -6 dB Bandwidth(MHz)Verdict NVNTb2412Ant19.53>=0.5Pass NVNTb2437Ant110.063>=0.5Pass NVNTb2462Ant110.078>=0.5Pass NVNTg2412Ant116.303>=0.5Pass NVNTg2437Ant114.988>=0.5Pass NVNTg2462Ant115.041>=0.5Pass NVNTn202412Ant115.008>=0.5Pass NVNTn202437Ant117.24>=0.5Pass NVNTn202462Ant113.826>=0.5Pass NVNTn402422Ant135.141>=0.5Pass NVNTn402437Ant135.105>=0.5Pass NVNTn402452Ant135.064>=0.5Pass Page3 of 55FCCID:2BHWI-BELLOHOMEReportNo.: LCSA04014061EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTb 2412MHzAnt1 -6dBBandwidthNVNTb 2437MHzAnt1 Page4 of 55FCCID:2BHWI-BELLOHOMEReportNo.: LCSA04014061EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 BldgC, Juji IndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTb 2462MHzAnt1 -6dBBandwidthNVNTg 2412MHzAnt1 Page5 of 55FCCID:2BHWI-BELLOHOMEReportNo.: LCSA04014061EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 B…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 36.90 mW |