2BHXR-YMX-WR01Wireless Charger

Shenzhen Yimeixin Electronics Co., LTD
Wireless Charger - FCC ID 2BHXR-YMX-WR01 - Shenzhen Yimeixin Electronics Co., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Aug 18, 2024
Application Purpose
Original Equipment
Date of Application
Aug 18, 2024
Equipment Note
Wireless Charger
Frequency Range
0.36000000 - 0.36000000
Company
Shenzhen Yimeixin Electronics Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Product Manual 1 EASY TO APPLY QI2 Wireless charger 1 Magnetic wireless charging area fbr iPhone 2 Power supply: TYPE-C. 2 Compatible Devices: This wireless charging pad is compatible with iPhone 14/13/12 Pro Max Plus as well as AirPods models with a wireless charging case. [ warm tip : 15W fast charging requires the system of iphone13-15 series models to upgraded to IOS17.2 or above, and the iphone12 series mobile phones need to upgrade the system to IOS17.4 or above ] 3 Specifications: Product name Wireless charger model YMX-WR01 Product Size 56mm*56mm*9.5mm Product weight 100g Input 5V/2A, 9V/2.2A output 15W/10W/7.5W/5W Wireless charger effortlessly aligns and securely attaches to your iPhone Please use a 20W or higher power wall charger to connect the Wireless charger 4 Matters needing attention: ①Please use a qualified fast charging power adapter (recommended to use PD 18W or higher power), otherwise it may cause unstable charging ②Please do not place metal debris or magnetic cards on this product as it may cause damage or abnormal charging ③Do not forcefully pull the charging cable to avoid the power cord breaking or falling off ④Please do not disassemble or put this product into fire or water by yourself to avoid short circuit and leakage ⑤Do not use this product in severely high-temperature, humid, or corrosive environments to avoid damaging the circuit and causing leakage 5 FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance between 20cm the radiator your body.

Attestation Statements

Shenzhen Yimeixin Electronics Co., LTD

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Yimeixin Electronics Co., LTD Grantee code: 2BHXR FRN: 0035741925 FCC ID: 2BHXR-YMX-WR01 Contact Name: Sean Li Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen, China. Telephone No: 17328762117 Fax No: Email: [email protected] i. [Shenzhen Yimeixin Electronics Co., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [ Shenzhen Yimeixin Electronics Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Shenzhen Yimeixin Electronics Co., LTD certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Date: 08.15.2024 Applicant’s Name: Sean Li Title: Product manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

CFR 47 §2.911 (d)(7) Agent Designation Attestation Date: 08-11-2024 FCC ID: 2BHXR-YMX-WR01 FRN: 0035741925 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Shenzhen Yimeixin Electronics Co., LTD. (“the applicant”) as required by section 2.911(d) (7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. U. S. Agent Information: James He Oasis Compliance, Inc. FRN: 0033464157 3313 Verdi Dr, San Jose, CA 95111 [email protected] cell:2026028330 Sincerely yours, Sean Li Manager Shenzhen Yimeixin Electronics Co., LTD Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen Email:[email protected] Phone: 17328762117

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Shenzhen Yimeixin Electronics Co., LTD Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen, China. Product Name: Wireless Charger Model Number: YMX-WR01 FCC Identifier: 2BHXR-YMX-WR01 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Sean Li Date: 8/15/2024 Title: Product manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Shenzhen Yimeixin Electronics Co., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 8/15/2024 Subject: Request for Confidentiality FCC ID: 2BHXR-YMX-WR01 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Sean Li Title: Product manager

External Photos

Page 1 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the EUT (External Photos) Model: YMX-WR01 Page 2 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 3 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 4 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected]

Internal Photos

Page 1 of 3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the EUT (Internal Photos) Model: YMX-WR01 Page 2 of 3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Coil Page 3 of 3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected]

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Tel: 0755-88850135-1439 Tel: 0755-88850135-1439 Tel: 0755-88850135-1439 Test Report Report No.: MTi240716006-11E2 Date of issue: 2024-08-08 Applicant: Shenzhen Yimeixin Electronics Co., LTD Product: Wireless Charger Model(s): YMX-WR01 FCC ID: 2BHXR-YMX-WR01 Shenzhen Microtest Co., Ltd. http:// Web: www.mtitest.cn Page 2 of 14 Report No.: MTi240716006-11E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel : (86-755) 88850135-1349 Fax: (86-755) 88850136 We b : http://www.mtitest.cn E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 14 Report No.: MTi240716006-11E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel : (86-755) 88850135-1349 Fax: (86-755) 88850136 We b : http://www.mtitest.cn E-mail: [email protected] Contents 1 General Description ........................................................................................................................ 5 1.1 Description of the EUT ....................................................................................................................................... 5 1.2 Description of test modes ................................................................................................................................... 5 1.3 Description of support units ................................................................................................................................ 6 2 Measurement uncertainty ............................................................................................................... 6 3 Test facilities and accreditations .................................................................................................... 7 3.1 Test laboratory .................................................................................................................................................... 7 4 List of test equipment ..................................................................................................................... 8 5 Test result ........................................................................................................................................ 9 5.2 Test setup ......................................................................................................................................................... 10 5.3 Test Procedures ................................................................................................................................................ 10 5.4 Information of test equipment ........................................................................................................................... 11 5.5 Test results ....................................................................................................................................................... 12 Photographs of the Test Setup ............................................................................................................ 14 Photographs of the EUT....................................................................................................................... 14 Page 4 of 14 Report No.: MTi240716006-11E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel : (86-755) 88850135-1349 Fax: (86-755) 88850136 We b : http://www.mtitest.cn E-mail: [email protected] Test Result Certification Applicant: Shenzhen Yimeixin Electronics Co., LTD Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen Manufacturer: Shenzhen Yimeixin Electronics Co., LTD Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen Product description Product name: Wireless Charger Trademark: FRIGRAF Model name: YMX-WR01 Series Model: N/A Standards: 47 CFR PART 1, § 1.1310 Test method: KDB 680106 D01 Wireless Power Transfer v04 Date of Test Date of test: 2024-07-24 to 2024-08-07 Te s t result: Pass Test Engineer : (Letter Lan) Reviewed By : (David Lee) Approved By : (Leon Chen) Page 5 of 14 Report No.: MTi240716006-11E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel : (86-755) 88850135-1349 Fax: (86-755) 88850136 We b : http://www.mtitest.cn E-mail: [email protected] 1 General Description 1.1 Description of the EUT Product name: Wireless Charger Model name: YMX-WR01 Series Model(s): N/A Model difference: N/A Electrical rating: Input: 5.0VDC 2.0A, 9.0VDC 2.2A Wireless output: 5W, 7.5W, 10W, 15W Accessories: N/A Hardware version: YMX-WR01 Software version: YMX-WR01 Test sample(s) number: MTi240716006-11S1001 RF specification Operating frequency range: 115-205kHz& 360kHz Modulation type: ASK Antenna(s) type: Coil 1.2 Description of test modes All the test modes were carried out with the EUT in normal operation, the final test mode of the EUT was the worst test mode for emission test, which was shown in this report and defined as: No. Emission test m…

Text truncated - open the document above for the full version.

Test Report

The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) We b : http://www.mtitest.cn E-mail: [email protected] Test Report Report No.: MTi240716006-11E1 Date of issue: 2024-08-08 Applicant: Shenzhen Yimeixin Electronics Co., LTD Product name: Wireless Charger Model(s): YMX-WR01 FCC ID: 2BHXR-YMX-WR01 Shenzhen Microtest Co., Ltd. http://www.mtitest.cn Page 2 of 29 Report No.: MTi240716006-11E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) We b : http://www.mtitest.cn E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 29 Report No.: MTi240716006-11E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) We b : http://www.mtitest.cn E-mail: [email protected] Table of contents 1 General Description ......................................................................................................................... 5 1.1 Description of the EUT ............................................................................................................................... 5 1.2 Description of test modes .......................................................................................................................... 5 1.3 Environmental Conditions .......................................................................................................................... 6 1.4 Description of support units ....................................................................................................................... 6 1.5 Measurement uncertainty .......................................................................................................................... 6 2 Summary of Test Result .................................................................................................................. 7 3 Test Facilities and accreditations ................................................................................................... 8 3.1 Test laboratory ........................................................................................................................................... 8 4 List of test equipment ...................................................................................................................... 9 5 Evaluation Results (Evaluation) .................................................................................................... 10 5.1 Antenna requirement ............................................................................................................................... 10 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 11 6.1 Conducted Emission at AC power line .................................................................................................... 11 6.2 20dB Occupied Bandwidth ...................................................................................................................... 14 6.3 Emissions in frequency bands (below 30MHz)........................................................................................ 18 6.4 Emissions in frequency bands (30MHz - 1GHz)...................................................................................... 23 Photographs of the test setup ............................................................................................................. 28 Photographs of the EUT....................................................................................................................... 29 Page 4 of 29 Report No.: MTi240716006-11E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) We b : http://www.mtitest.cn E-mail: [email protected] Test Result Certification Applicant: Shenzhen Yimeixin Electronics Co., LTD Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen Manufacturer: Shenzhen Yimeixin Electronics Co., LTD Address: Room 3A01-7, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village Community, Nanwan Street, Longgang District, Shenzhen Product description Product name: Wireless Charger Trademark: FRIGRAF Model name: YMX-WR01 Series Model(s): N/A Standards: 47 CFR Part 15C Test Method: ANSI C63.10-2013 Date of Test Date of test: 2024-07-24 to 2024-08-07 Test result: Pass Test Engineer : (Letter Lan) Reviewed By : (David Lee) Approved By : (Leon Chen) Page 5 of 29 Report No.: MTi240716006-11E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) We b : http://www.mtitest.cn E-mail: [email protected] 1 General Description 1.1 Description of the EUT Pr…

Text truncated - open the document above for the full version.

Test Report

惠州启泰电子科技有限公司 HuizhouQitaiElectronicTechnologyCo.,LTD SPECIFICATIONSSHEET CUSTOMER: 客户 DESCRIPTION: 品名描述 CUSTOMERP/N: 客户品名 PARTNUMBER: 制造商料号 DATEOFAPPLICATION: 提出日期 TX线圈 2023-12-15 CLASSIFICATIONOFSPEC.PRESENTATION.(Ticktherelevantbox"√") oNewapplication新规格 √Newpartisaddedtoacceptedspecification新产品规格追加记录 oRevisionofacceptedspecification既存规格图面变更 ACCEPTANCESTAMP() APPROVALBY 承认 CHECKBY 审查 PREPAREBY 制作 ADDRESS:3rdFloor,No.181,Mingyue2ndRoad,ShiwanTown,BoluoCounty,Huizhoucity TELPHONE:0752-6668681 E-MAIL:[email protected] 惠州启泰电子科技有限公司 HuizhouQitaiElectronicTechnologyCo.,LTD HistoryForRevisedSpecification CUSTOMERP/N: 客户品名 PARTNUMBER: 制造商料号 Item 项次 DESCRIPTION(ContentOrReasonForChanged) 变更内容 Rev. 版本 CustRev. 客户版本 Date 日期 Revisor 修订者 1 InitialRelease(初版发行) A0 2023-12-15 陈骏 APPROVEDBY 承认 CHECKEDBY 审查 PREPAREDBY 制作 DATE 日期 PAGE 页码 晁子奇 陈骏 2023-12-15 1of3 惠州启泰电子科技有限公司 HuizhouQitaiElectronicTechnologyCo.,LTD Specification 规格内容 CUSTOMERP/N: 客户品名 PARTNUMBER: 制造商料号 1.DIMENSIONS():(Unit:mm) 单位(Unit):毫米(mm). ABCDEFGH 20±0.320.5±0.539±142.5±0.511±1 3±1 0.8±0.1 2.3max 1.背胶为白色双面胶。 2.线圈贴合位置居中。 APPROVEDBY 承认 CHECKEDBY 审查 PREPAREDBY 制作 DATE 日期 PAGE 页码 2023-12-15 2of3 惠州启泰电子科技有限公司 HuizhouQitaiElectronicTechnologyCo.,LTD Specification 规格内容 CUSTOMERP/N: 客户品名 PARTNUMBER: 制造商料号 2.WINDINGDETAILS(绕线详细说明) Coil1 圈数 Turns 线径 WireDia 绕线方式疏/密 Wdg.Type Spred/Close 绕线方向 Wdg.Direction 相交是/否 Intersect Yes/Not 11TS 0.08*100P热风自粘线 密绕(Close) 逆绕 是(Yes) 3.电气特性(ELECTRICALCHARACTERISTICS): 温度TEMPERATURE:25±10,RELATIVEHUMIDITY:6510% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS Coil1 1. INDS-F 7.9uh±10% 100kHz/VUC2906A 2.QS-F 40Min 100kHz/VUC2906A 3. DCRS-F 80mΩMax 100kHz/VUC2906A APPROVEDBY 承认 CHECKEDBY 审查 PREPAREDBY 制作 DATE 日期 PAGE 页码 2023-12-15 3of3

Test Setup Photos

Page 1 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the test setup Model: YMX-WR01 Emissions in frequency bands (below 30MHz) Emissions in frequency bands (30MHz - 1GHz) Page 2 of 2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] MPE Conducted Emission at AC power line

Contact Information

Applicant

Sean Li(Product manager)
[email protected]17328762117Fax: -

Technical Contact

Shenzhen Microtest Co., LtdLeon Chen
[email protected]+86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
215C0.36 MHz - 0.36 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.