Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition, compliance with exposure requirements. Warranty Information Limited Product Warranty Thank you for choosing our Smart Health Monitoring Shoes. We stand behind the quality and functionality of our product. This limited warranty is designed to provide you with peace of mind regarding your purchase. Warranty Period The Smart Health Monitoring Shoes are covered by a limited warranty for a period of [6 months] from the date of purchase. This warranty is valid for the original purchaser and is non-transferable. Coverage Our warranty covers defects in materials and workmanship under normal use. It includes, but is not limited to, the following components: Smart Shoes: Any manufacturing defects affecting the functionality of the smart shoes. Wireless Charging Plate: Any manufacturing defects affecting the functionality of the wireless charging plate. C to C Type Charging Cable: Any manufacturing defects affecting the functionality of the charging cable. English2 This warranty does not cover: Exclusions Damage caused by accidents, misuse, or abuse. Normal wear and tear, including but not limited to cosmetic damages. Unauthorized modifications or repairs. Damage caused by failure to follow product instructions. Claim Process Contact Customer Support: In the event of a warranty claim, please contact our customer support via email at [email protected]. Provide Proof of Purchase: To process your warranty claim, you must provide a copy of the original purchase receipt. Evaluation and Resolution: Our customer support team will guide you through the evaluation process. If a manufacturing defect is confirmed, we will, at our discretion, repair or replace the defective product. Return Procedure If a return is deemed necessary, you will be provided with instructions on how to return the product. Please note that shipping costs associated with returns may be covered under this warranty, depending on the circumstances. English3 Disclaimer This warranty is the sole and exclusive warranty for our Smart Health Monitoring Shoes. Any implied warranties, including those of merchantability and fitness for a particular purpose, are limited to the duration of this warranty. Limitation of Liability To the maximum extent permitted by law, our liability for any claim arising under or in connection with this warranty will be limited to the purchase price paid for the product. Future Updates We may periodically release updates or improvements for your smart shoes. These updates may be available through our mobile application. Please ensure your shoes are connected to the app to receive notifications about any available updates. English4 Garantía limitada del producto Gracias por elegir nuestros zapatos inteligentes para monitorear la salud. Respaldamos la calidad y funcionalidad de nuestro producto. Esta garantía limitada está diseñada para brindarle tranquilidad con respecto a su compra. Período de garantía Los Smart Health Monitoring Shoes están cubiertos por una garantía limitada por un período de [6 años/meses] a partir de la fecha de compra. Esta garantía es válida para el comprador original y no es transferible. Cobertura Nuestra garantía cubre defectos en materiales y mano de obra bajo uso normal. Incluye, entre otros, los siguientes componentes: Zapatos inteligentes: Cualquier defecto de fabricación que afecte la funcionalidad de los zapatos inteligentes. Placa de carga inalámbrica: Cualquier defecto de fabricación que afecte la funcionalidad de la placa de carga inalámbrica. Cable de carga tipo C a C: cualquier defecto de fabricación que afecte la funcionalidad del cable de carga. Español5 Esta garantía no cubre: Exclusiones Daños causados por accidentes, mal uso o abuso. Desgastes normales de uso, incluidos, entre otros, daños cosméticos. Modificaciones o reparaciones no autorizadas. Daños causados por no seguir las instrucciones del producto. Proceso de reclamo Comuníquese con el servicio de atención al cliente: en caso de un reclamo de garantía, comuníquese con nuestro servicio de atención al cliente por correo electrónico a [email protected].. Proporcionar prueba de compra: para procesar su reclamo de garantía, debe proporcionar una copia del recibo de compra original. Evaluación y resolución: nuestro equipo de atención al cliente lo guiará a través del proceso de evaluación.…
Text truncated - open the document above for the full version.
TactusVenturesInc FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 9/12/24 U.S.AgentDesignation TactusVenturesIncacknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatestoactas theiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2BHYY- FOOTWEAR): NameandcompanyofU.S.agent:TactusVenturesInc PhysicalU.S.addressofagent:16192CoastalHighwayCountyofSussexDelaware19958United States FRNofU.S.agent:0035752757 EmailaddressofU.S.agent:[email protected] TactusVenturesIncacknowledgestheirobligationtoacceptserviceofprocessonbehalfofTactusVentures Inc. TactusVenturesIncwiththeFRN0035752757acceptsitsobligationtomaintainanagentforserviceofprocess intheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketing andimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature KaranBhasin Founder&CEO TactusVenturesInc Signature KaranBhasin Founder&CEO TactusVenturesInc 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BHYY-FOOTWEAR Footwear We, Applicant Company Name: Tactus Ventures Inc Address: 16192 Coastal Highway, County of Sussex, Delaware 19958, United States Phone: +1-961-998-9195 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc.. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-12 Signature Date Name / Title: Karan Bhasin / Founder & CEO Company: Tactus Ventures Inc Address: 16192 Coastal Highway, County of Sussex, Delaware 19958, United States Phone: +1-961-998-9195 Fax: N/A E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BHYY-FOOTWEAR Footwear For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-12 Signature Date Name / Title: Karan Bhasin / Founder & CEO Company: Tactus Ventures Inc Address: 16192 Coastal Highway, County of Sussex, Delaware 19958, United States Phone: +1-961-998-9195 Fax: N/A E-Mail: [email protected]
Page 1 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page 1 of 1 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 4.0cm x W 2.0cm) Label Location OWN Smart Wearable Footwear Model: Footwear FCC ID: 2BHYY-FOOTWEAR
Page 1 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 WPT RX Antenna BT Antenna GPS Antenna Page 8 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 9 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18
Page 1 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information Applicant : Tactus Ventures INC Address : 16192 Coastal Highway,Lewes, Delaware 19958, Country of Sussex DE 19958 US FCC ID : 2BHYY-FOOTWEAR Product name : OWN Smart Wearable Footwear Test Model : Footwear Power Supply : For AC Adapter: Input:100-240V~, 50/60Hz, 0.6A Max Output: 5V3A, 9V2.22A, 12V1.67A, 20W Max Hardware Version : / Software Version / Bluetooth : 2402MHz ~ 2480MHz Channel Number : 79 channels for Bluetooth V5.0 (DSS) 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 1MHz for Bluetooth V5.0(DSS) 2MHz for Bluetooth V5.0 (DTS) Modulation Type : GFSK , π/4-DQPSK for Bluetooth V5.0 (DSS) GFSK for Bluetooth V5.0 ((DTS) Bluetooth Version : V5.0 Antenna Type : PCB Antenna Antenna Gain : 2.41dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific Page 2 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 4 FCC ID: 2BHYY-FOOTWEAR Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results <BT> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.82 39 2441 -0.33…
Text truncated - open the document above for the full version.
Antenna Study Project Name : FTW01 Debugging frequency band: 2400 ‐ 2500HMz Valuation date : 2024.09.06 8 Client Name:TACTUSVENTURESPVT.LTD 1 L inkman contacts : he hai ping 13686295193 8 Room 101, Building 2, No. 9 Xinfa Road, Lincun, Tangxia Town, Dongguan, Guangdong, China PCB Antenna 2 Testing 3D microwave darkroom(6m*6m*6m) Testing environment PCB Antenna 3 Antenna • Antenna name: 2.4G • Antenna Type : PCB • Covers : 2400/2500MHz 4 S Parameter_Return Loss&VSWR‐Smith 5 Efficiency and Gain Frequency ID 1 2 3 4 5 6 7 8 9 10 11 Frequency (MHz) 2400.0 2410.0 2420.0 2430. 0 2440.0 2450.0 2460.0 2470.0 2480.0 2490.0 2500.0 Gain (dBi) 2.01 2.27 1.85 1.83 2.09 2.16 2. 27 2.39 2.41 2.16 1.92 Efficiency (%) 45.82 45.64 44.33 44.44 45.33 46.57 47.24 46.89 44.70 42.46 41.52 2400.0MHz Total, Eff: 45.8%Back View2400.0MHz Total(E1-XZ), Max= -0.91dBi2400.0MHz Total(E2-YZ), Max= 1.27dBiTotal(H-XY), Max= -0.89dBi, CirD=11.15 2.01 0.17 -1.67 -3.52 -5.36 -7.2 -9.04 -10.88 -12.73 -14.57 -16.41 -18.25 -20.09 -21.94 -23.78 -25.62 -27.46 -29.31 2410.0MHz Total, Eff: 45.6%Back View2410.0MHz Total(E1-XZ), Max= -0.86dBi2410.0MHz Total(E2-YZ), Max= 1.18dBiTotal(H-XY), Max= -1.10dBi, CirD=11.93 2.27 0.42 -1.42 -3.26 -5.1 -6.94 -8.79 -10.63 -12.47 -14.31 -16.15 -18 -19.84 -21.68 -23.52 -25.37 -27.21 -29.05 2420.0MHz Total, Eff: 44.3%Back View2420.0MHz Total(E1-XZ), Max= -1.00dBi2420.0MHz Total(E2-YZ), Max= 0.76dBiTotal(H-XY), Max= -1.16dBi, CirD=13.61 1.85 0.01 -1.84 -3.68 -5.52 -7.36 -9.2 -11.05 -12.89 -14.73 -16.57 -18.42 -20.26 -22.1 -23.94 -25.78 -27.63 -29.47 2430.0MHz Total, Eff: 44.4%Back View2430.0MHz Total(E1-XZ), Max= -1.05dBi2430.0MHz Total(E2-YZ), Max= 0.82dBiTotal(H-XY), Max= -0.87dBi, CirD=15.77 1.83 -0.01 -1.85 -3.7 -5.54 -7.38 -9.22 -11.06 -12.91 -14.75 -16.59 -18.43 -20.27 -22.12 -23.96 -25.8 -27.64 -29.48 2440.0MHz Total, Eff: 45.3%Back View2440.0MHz Total(E1-XZ), Max= -1.06dBi2440.0MHz Total(E2-YZ), Max= 1.08dBiTotal(H-XY), Max= -0.53dBi, CirD=16.53 2.09 0.25 -1.59 -3.44 -5.28 -7.12 -8.96 -10.81 -12.65 -14.49 -16.33 -18.17 -20.02 -21.86 -23.7 -25.54 -27.38 -29.23 2450.0MHz Total, Eff: 46.6%Back View2450.0MHz Total(E1-XZ), Max= -0.82dBi2450.0MHz Total(E2-YZ), Max= 1.18dBiTotal(H-XY), Max= -0.22dBi, CirD=16.11 2.16 0.32 -1.52 -3.36 -5.2 -7.05 -8.89 -10.73 -12.57 -14.41 -16.26 -18.1 -19.94 -21.78 -23.62 -25.47 -27.31 -29.15 2460.0MHz Total, Eff: 47.2%Back View2460.0MHz Total(E1-XZ), Max= -0.52dBi2460.0MHz Total(E2-YZ), Max= 1.13dBiTotal(H-XY), Max= -0.00dBi, CirD=14.89 2.27 0.42 -1.42 -3.26 -5.1 -6.94 -8.79 -10.63 -12.47 -14.31 -16.15 -18 -19.84 -21.68 -23.52 -25.36 -27.21 -29.05 2470.0MHz Total, Eff: 46.9%Back View2470.0MHz Total(E1-XZ), Max= -0.62dBi2470.0MHz Total(E2-YZ), Max= 1.35dBiTotal(H-XY), Max= -0.24dBi, CirD=15.21 2.39 0.55 -1.29 -3.13 -4.98 -6.82 -8.66 -10.5 -12.35 -14.19 -16.03 -17.87 -19.71 -21.56 -23.4 -25.24 -27.08 -28.92 2480.0MHz Total, Eff: 44.7%Back View2480.0MHz Total(E1-XZ), Max= -1.27dBi2480.0MHz Total(E2-YZ), Max= 1.26dBiTotal(H-XY), Max= -0.68dBi, CirD=17.77 2.41 0.56 -1.28 -3.12 -4.96 -6.8 -8.65 -10.49 -12.33 -14.17 -16.01 -17.86 -19.7 -21.54 -23.38 -25.23 -27.07 -28.91 2490.0MHz Total, Eff: 42.5%Back View2490.0MHz Total(E1-XZ), Max= -1.09dBi2490.0MHz Total(E2-YZ), Max= 1.14dBiTotal(H-XY), Max= -0.87dBi, CirD=20.47 2.16 0.32 -1.52 -3.37 -5.21 -7.05 -8.89 -10.73 -12.58 -14.42 -16.26 -18.1 -19.94 -21.79 -23.63 -25.47 -27.31 -29.15 2500.0MHz Total, Eff: 41.5%Back View2500.0MHz Total(E1-XZ), Max= -1.25dBi2500.0MHz Total(E2-YZ), Max= 1.08dBiTotal(H-XY), Max= -0.50dBi, CirD=17.93 1.92 0.08 -1.77 -3.61 -5.45 -7.29 -9.14 -10.98 -12.82 -14.66 -16.5 -18.35 -20.19 -22.03 -23.87 -25.71 -27.56 -29.4
Page 1 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B RF Test Data for BT LE (Conducted Measurement) Product Name: OWN Smart Wearable Footwear Test Model: Footwear Environmental Conditions Temperature: 23.8C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Jerry Chu Supervised by: Nick Peng Page 2 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.701 >=0.5 Pass NVNT BLE 1M 2440 Ant1 0.704 >=0.5 Pass NVNT BLE 1M 2480 Ant1 0.685 >=0.5 Pass Page 3 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 0.43 30 Pass NVNT BLE 1M 2440 Ant1 -0.91 30 Pass NVNT BLE 1M 2480 Ant1 -0.53 30 Pass Page 6 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 7 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Page 8 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -14.77 8 Pass NVNT BLE 1M 2440 Ant1 -16.19 8 Pass NVNT BLE 1M 2480 Ant1 -15.97 8 Pass Page 9 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 10 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 1M 2480MHz Ant1 Page 11 of 23 FCC ID: 2BHYY-FOOTWEAR Report No.: LCSA06194161EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 1M 2402 Ant1 …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |