FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PRIMECLICK LLC/
  3. 2BK2R-AIRLINK

2BK2R-AIRLINKWireless foot pedal

PRIMECLICK LLC
Wireless foot pedal - FCC ID 2BK2R-AIRLINK - PRIMECLICK LLC
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 24, 2024
Application Purpose
Original Equipment
Date of Application
Sep 24, 2024
Equipment Note
Wireless foot pedal
Frequency Range
432.97000000 - 432.97000000
Company
PRIMECLICK LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USERMANUAL Wirelessfootpedal MODEL:AirLink Preface Thismanualincludeshardwaredescriptionandoperationintroductionoftheequipment.Foryourand otherpeople’ssafety,pleasereadthemanualcarefully. Payattention Payattentiontothewordsafterthesignsbelow. SignDescription Thewordsafterthissignmeansthereisgreatpotentialdanger, whichmaycausemajoraccident,damageorevendeath,ifitisnot followed. Thewordsafterthissignmeansthereissomepotentialdanger, whichmaycausehurtorpropertylose,ifitisnotfollowed. Thewordsafterthissignmeansthereispotentialrisk,whichmay causeequipmentfaultorbreak,ifitisnotfollowed. Version Thecontentsofthismanualareupdatedirregularityforupdatingofproduct.Themanualisonlyusedas operationguide,exceptforotherpromises.Nowarrantiesofanykind,eitherexpressorimpliedare madeinrelationtothedescription,informationorsuggestionoranyothercontentsofthemanual. Theimagesshownhereareindicativeonly.Ifthereisinconsistencybetweentheimageandtheactual product,theactualproductshallgovern. Content 1Safetywarning..........................................................................................................1 2Product......................................................................................................................5 2.1Introduction........................................................................................................5 2.2Technicaldata....................................................................................................5 3Installation................................................................................................................6 4Operation..................................................................................................................7 4.1panellayout........................................................................................................7 5INSTRUCTIONNOTES.............................................................................................8 5.1Operationenvironment.....................................................................................8 5.2SAFTY.................................................................................................................8 6MAINTENANCEANDCHECKTROUBLE................................................................9 6.1Maintenance...................................................................................................9 6.2CheckFault........................................................................................................9 1 1Safetywarning Thesafetynoteslistedinthismanualistoensurecorrectuseofthemachineandtokeepyouand otherpeoplefrombeinghurt. Thedesignandmanufactureofweldingmachineconsiderssafety.Pleaserefertothesafety warninglistedinthemanualtoavoidaccidents. Differentdamagewouldbecausedbywrongoperationoftheequipmentasfollows.Pleaseread theusermanualcarefullytoreducesuchdamage. SignDescription Anycontactofelectricpartsmaycausefatalelectricshockorburnt.  Gasandfumesareharmfultohealth. Operationinnarrowspacemaycausechoke. Sparkandhotworkpieceafterweldingmaycausefire.  Badconnectedcablemaycausefire. Incompletionconnectionofworkpiecesidecircuitmaycausefire.  Neverweldonthecaseoftinderstuff,oritmaycauseexplode. Neverweldairtightcontainerssuchasslot,pipeetc.,oritmaybreak. Arcraymaycauseeyeinflammationorskinburnt. Sparkandresiduewillburnyoureyesandskin.  Topplingoverofthegascylinderwillcausebodyhurt. Wronguseofthegascylinderwillleadtohigh-pressuregaseruption andcausehumanhurt. Neverletfingers,hair,clothesoretc.nearthemovingpartssuchas thefan.  Thewireshootoutofthetorchmaystabeyes,faceandothernaked parts.  Neverstandinfrontoftheswangequipmentorunderit,oritmayfail andcauseinjury. 2 Pleasefollowtherulesbelowtoavoidheavyaccidents. Neverusetheequipmenttodootherthingsbutwelding. Followrelatedregulationsfortheconstructionoftheinput-drivenpowersource,choiceofplace, usageofhigh-pressuregas,storage,configuration,safe-keepingofworkpieceafterwelding anddisposalofwaste,etc. Nonessentialsdonotentertheweldingarea. Peopleusingheartpacemakerisnotallowedtogetclosetotheweldingmachineorarea withoutdoctor’spermission.Themagnetismcreatedbyenergizingtheweldingmachinecan haveabadeffecttothepacemaker. Install,operation,checkandmaintaintheequipmentbyprofessionpersonnel. Understandingthecontentsoftheusermanualforsafety. Pleasefollowtherulesbelowtoavoidelectricshock。 Keepawayfromanyelectricparts. Earththemachineandworkpiecebyprofessionalpersonnel. Cutoffthepowerbeforeinstallationorchecking,andrestart5minuteslater.Thecapacitanceis chargeabledevice.Pleaseensureithasnovoltagebeforestartagainevenifthepowersource iscutoff. Donotusewirewithinadequatesectionsurfaceordamageinsulationsleeveorevenexposed conductor. Doensurewellisolationofwireconnection. Neverusethedevicewhentheenclosureisremoved. Neverusebrokenorwetinsulationgloves. Usefirenetwhenworkathighposition. Checkandmaintainregularly,don’tuseituntilthebrokenpartsarefixedwell. Turnoffthepowerwhennotinused. FollowthenationalorlocalrelatedstandardandregulationswhenusingtheACwelding machineatnarroworhighposition. Pleasefollowthebelownotestoavoidfireandexplode,etc. Nocombustibleinweldingarea. Keepoffcombustiblewhenwelding. Keephotworkpieceafterweldingawayfromflammablegas. Domoveawaythecombustiblearoundwhenweldthedooryard,groundandwall,. Thewireconnectionofbasemetalshouldbeasclosetotheweldingplaceaspossible. Neverweldthosefacilitieswithgaspipeorairtightslot. Putfireextinguisheraroundtheweldingareatopreventfire. Thegasandfumesareharmfultohealth,pleasewearprotectivedevice accordingtoregulations. Wearexhaustequipmentandbreathepreventivefacilitiestopreventgaspoisoningorchoke. Usesuggestedpartexhaustequipmentandbreathepreventivefacilitiestopreventhurtor poisoningbygasandotherpowder,please. Topreventoxygen-deficiency,airoutthegas-filledroomwhichisfullofCO2andargononthe bottom,Whenoperatingontrunks,boilers,cabins,etc. Pleaseacceptthesupervisor’sinspectionwhenoperatinginnarrowspace.Airtherooma…

Text truncated - open the document above for the full version.

Attestation Statements

PRIMECLICKLLC FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 9/25/24 U.S.AgentDesignation PRIMECLICKLLCacknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatestoactas theiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2BK2R-AIRLINK): NameandcompanyofU.S.agent:PRIMECLICKLLC PhysicalU.S.addressofagent:1001LOWERLANDINGRD#205BLACKWOOD,NJ08012 FRNofU.S.agent:0035938414 EmailaddressofU.S.agent:[email protected] PRIMECLICKLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofPRIMECLICKLLC. PRIMECLICKLLCwiththeFRN0035938414acceptsitsobligationtomaintainanagentforserviceofprocessin theUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingand importationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature DustinGallaher Companyowner PRIMECLICKLLC Signature DustinGallaher Companyowner PRIMECLICKLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

External Photos

Page1of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. ExternalPhotos Photo1 Photo2 Page2of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo3 Photo4 Page3of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo5 Photo6 Page4of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo7 Photo8 Page5of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo9 Photo10 Page6of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo11 Photo12 Page7of7FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo13 ------End------

ID Label/Location Info

Label FCCID:2BK2R-AIRLINK

Internal Photos

Page1of6FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. InternalPhotos Photo1 Photo2 Page2of6FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo3 Photo4 Page3of6FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo5 Photo6 Page4of6FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo7 Photo8 Antenna Page5of6FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo9 Photo10 Page6of6FCCID:2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo11 Photo12 ------End------

RF Exposure Info

RFExposureevaluation FCCID:2BK2R-AIRLINK 1.1.ApplicableStandard Accordingto§1.1307(b)(1),systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. Accordingto§1.1310and§2.1093RFexposurerequirement KDB447498v06:MobileandPortableDevicesRFExposureProceduresandEquipmentAuthorization Policies 1.2.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSARtest exclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures, standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions, bymeasurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARTestExclusion Thresholdcondition,listedbelow,issatisfied.Thesetestexclusionconditionsarebasedonsource-based time-averagedmaximumconductedoutputpoweroftheRFchannelrequiringevaluation,adjustedfortune-up tolerance,andtheminimumtestseparationdistancerequiredfortheexposureconditions.22Theminimum testseparationdistanceisdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresor outersurfaceofthedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements, toanypartofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbytheoperating configurationsandexposureconditionsofthetransmitterandapplicablehostplatformrequirements,typically intheSARmeasurementorSARanalysisreport,accordingtotherequiredpublishedRFexposureKDB procedures.WhennootherRFexposuretestingorreportingisrequired,astatementofjustificationand compliancemustbeincludedintheequipmentapproval,inlieuoftheSARreport,toqualifyfortheSARtest exclusion.Whenrequired,thedevicespecificconditionsdescribedintheotherpublishedRFexposureKDB proceduresmustbesatisfiedbeforeapplyingtheseSARtestexclusionprovisions;forexample,handheldPTT two-wayradios,handsets,laptops&tabletsetc.23“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)]·[√f(GHz)] ≤ 3.0for1-gSARand ≤ 7.5for10-gextremitySAR,where: • f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison • 3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mmandfor transmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtestseparationdistanceis<5 mm,adistanceof5mmaccordingto5)insection4.1isappliedtodetermineSARtestexclusion. 1.3.Manufacturingtolerance Freq. (MHz) Field strength(max)(dBuV/m) EIRP(max) (dBm) Turn-upPower (dBm) Tolerance± (dB) 432.97MHz85.19-10.07-10.0 ±1 Note: EIRP=E-104.8+20logD,D=3 Page2of2 2.EvaluationResult EvaluationResults Band/Mode Antenna Distance (mm) Max.RFoutputpower (includingtune-up tolerance) SARTest Exclusion Threshold SARTest Exclusion dBmmW 432.97MHz 5 -100.100.03<3 Yes 3.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRFExposure andSARExclusionThresholdperKDB447498v06 .....................EndofReport.........................

Test Report

Page 1 of 33 ReportNo.:AiTDG-240905007W1 DongguanYaxu(AiT)TechnologyLimited No.22,JinqianlingThirdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. TestReport ClientInformation: Applicant:PRIMECLICKLLC Applicantadd.:1001LOWERLANDINGRD#205BLACKWOOD,NJ08012 ProductInformation: ProductName:Wirelessfootpedal ModelNo.:AirLink BrandName:PrimeWeld FCCID:2BK2R-AIRLINK Standards: FCC47CFRPART15SUBPARTC15.231 PreparedBy: DongguanYaxu(AiT)TechnologyLimited Add.:No.22,JinqianlingThirdStreet,Jitigang,Huangjiang,Dongguan, Guangdong,China DateofReceipt:Sep.05,2024DateofTest:Sep.05,2024~Sep.11,2024 DateofIssue:Sep.12,2024TestResult:Pass ThisdevicedescribedabovehasbeentestedbyDongguanYaxu(AiT)TechnologyLimited,andthe testresultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.And itisapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofDongguanYaxu(AiT) TechnologyLimited. Reviewedby:Approvedby: EmiyaLinSimbaHuang Page 2 of 33 ReportNo.:AiTDG-240905007W1 DongguanYaxu(AiT)TechnologyLimited No.22,JinqianlingThirdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. 1Contents Page COVERPAGE 1CONTENTS........................................................................................................................................................................2 2TESTSUMMARY...............................................................................................................................................................4 2.1STATEMENTOFTHEMEASUREMENTUNCERTAINTY........................................................................................................4 2.2MEASUREMENTUNCERTAINTY.......................................................................................................................................4 3TESTFACILITY.................................................................................................................................................................5 3.1DEVIATIONFROMSTANDARD..........................................................................................................................................5 3.2ABNORMALITIESFROMSTANDARDCONDITIONS..............................................................................................................5 3.3TESTLOCATION............................................................................................................................................................5 4GENERALINFORMATION...............................................................................................................................................6 4.1GENERALDESCRIPTIONOFEUT...................................................................................................................................6 5DESCRIPTIONOFTESTCONDITIONS...........................................................................................................................8 5.1E.U.T.OPERATION.......................................................................................................................................................8 5.2EUTPERIPHERALLIST..................................................................................................................................................9 5.3TESTPERIPHERALLIST.................................................................................................................................................9 6EQUIPMENTSLISTFORALLTESTITEMS..................................................................................................................10 7TESTRESULT.................................................................................................................................................................12 7.1ANTENNAREQUIREMENT.............................................................................................................................................12 7.2TRANSMITTIME...........................................................................................................................................................13 7.2.1Appliedprocedures/Limit.................................................................................................................................13 7.2.2Testprocedure..................................................................................................................................................13 7.2.3Deviationfromstandard....................................................................................................................................13 7.2.4Testsetup..........................................................................................................................................................13 7.2.5Testresults........................................................................................................................................................14 7.3FIELDSTRENGTHOFFUNDAMENTAL&FIELDSTRENGTHOFUNWANTEDEMISSIONS.....................................................15 7.3.1Testprocedure..................................................................................................................................................19 7.4OCCUPIEDBANDWIDTH&BANDEDGE.........................................................................................................................27 7.5CONDUCTEDEMISSIONSATMAINSTERMINALS150KHZTO30MHZ...........................................................................29 7.5.1TestResult.........................................................................................................................................................31 8PHOTOGRAPHS.............................................................................................................................................................33 8.1RADIATEDEMISSIONTESTSETUP....................................................................................…

Text truncated - open the document above for the full version.

Test Report

ANTENNA SPECIFICATON 1.Summary ITEM ANT SPEC Model Name 433M ANT Antenna plate Spring antenna Frequency range 432.97MHz MAX.Gain 3.5dBi Polarization Vertical 50 OhImpedancem X-Z Plane Y-Z Plane X-Y Plane

Test Setup Photos

Page1of2FCCID : 2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. TestSetupPhoto RadiatedEmission Page2of2FCCID : 2BK2R-AIRLINK DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. ConductedEmission ------End------

Contact Information

Applicant

Dustin Gallaher(Company owner)
[email protected]856 500 2000Fax: 856 500 2000

Test Firm

Guangdong Asia Hongke Test Technology LimitedDarren Ding
[email protected]185656258618

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231432.97 MHz - 432.97 MHz-
Confidentiality
Long Term