Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Attestation Statements 10/10/2024 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for Grantee Code: 2BK3W Suzhou Lishen Energy Science & Technology Co.,Ltd., the undersigned, hereby authorize Wilson Tech Service LLC to act as our designated U.S. agent for service of process, Suzhou Lishen Energy Science & Technology Co.,Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Wilson Tech Service LLC accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Suzhou Lishen Energy Science & Technology Co.,Ltd. Contact Name: Wenhong Xie Address: Room 301-1 , No. 4 plant, No. 588 Wutaishan Road, SND, Suzhou, Jiangsu, P.R. China FRN: 0035934215 Telephone No: 0512-67540093 Email: [email protected] Signature [Wenhong Xie] U.S. Agent Information: Company Name: Wilson Tech Service LLC Address: 1312 17th Street Suite 692, Denver, CO, 80202, US FRN: 0033402033 Contact Name: Wilson Cheung Telephone No: +1-716-965-5112 Email: [email protected] Signature [Wilson Cheung]
Suzhou Lishen Energy Science & Technology Co.,Ltd. Address: Room 301-1 , No. 4 plant, No. 588 Wutaishan Road, SND, Suzhou, Jiangsu, P.R. China Confirmation Letter We, Suzhou Lishen Energy Science & Technology Co.,Ltd. The product: Remote Control And model No.: FA2R01REM, FA2R02REM, FA2R03REM, FA2R04REM, FA2R05REM, FA2R06REM FCC ID: 2BK3WLS1476155FA IC: 33029-LS246PT01FA FA2R01REM, FA2R02REM, FA2R03REM, FA2R04REM, FA2R06REM have the same technical construction including circuit diagram, PCB Layout, components and component layout, all electrical construction and mechanical construction with FA2R05REM . The only difference is the model numbers, which represent different colors of the appearance. Contact Name: Wenhong Xie Title of Person: Deputy General Manager Date: 10/8/2024
Appendix I External Photographs Page 2 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. All View of EUT Top View of EUT Page 3 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Bottom View of EUT Front View of EUT Page 4 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Back View of EUT Left View of EUT Page 5 of 5 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Right View of EUT
Note: This label will be permanently engraved on the back of this device Label Location
Appendix II Internal Photographs Page 2 of 3 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Open View of EUT Internal View of EUT-1 Page 3 of 3 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Internal View of EUT-2 Antenna and RF Module Location
FCC ID: 2BK3WLS1476155FA According to KDB 447498 D01 General RF Exposure Guidance v06, section 4.3.1 At 100 MHz to 6 GHz and for test separation distances ≤ 50 mm, the SAR test exclusion threshold is determined according to the following [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] x [√f(GHz)] ≤ 3.0 1. SAR test exclusion threshold Frequency: 433.92 MHz (min. separation distances = 5 mm) SAR test exclusion thresholds (5 mm) = 3 x 5 / (√ 0.43392) = 22.77 mW Max. Tune-up Tolerance (mW) SAR Test Exclusion Thresholds (5mm) (mW) 1 22.77 Calculation Value: 1 (mW) / 5 (mm) x √ 0.43392 = 0.132 So, Calculation value ≤ 3.0 Remark: -Based on field strength 57.43 dBuV/m at 3m transmit power(eirp) of the device was calculated as 0.0002 mW using free space formula. -Max. conducted power 0.0002 mW is closet 1 mW, so 1 mW was calculated. -When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2. Conclusion: No SAR is required.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C ISED RSS-210 ISSUE 10 TEST REPORT For Remote Control MODEL NUMBER: FA2R05REM SERIES MODEL NUMBER: FA2R01REM, FA2R02REM, FA2R03REM, FA2R04REM, FA2R06REM PROJECT NUMBER: 4791417323 REPORT NUMBER: 4791417323-1 FCC ID: 2BK3WLS1476155FA IC: 33029-LS246PT01FA ISSUE DATE: Oct. 11, 2024 Prepared for Suzhou Lishen Energy Science & Technology Co., Ltd. Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122, China Tel: +86 512-6808 6400 Fax: +86 512-6808 4099 Website: www.ul.com Report No.: 4791417323-1 Page 2 of 39 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Revision History Rev. Issue Date Revisions Revised By V0 10/11/2024 Initial Issue Report No.: 4791417323-1 Page 3 of 39 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. Summary of Test Results Clause Test Items FCC/ISED Rules Test Results 1 Transmitter Timeout CFR 47 FCC §15.231 (a) (1) ISED RSS-210 Annex A.1.1 Pass 2 20 dB Bandwidth and 99% Occupied Bandwidth CFR 47 FCC §15.231 (c) ISED RSS-210 Annex A.1.3 Pass 3 Radiated Emission CFR 47 FCC §15.231 (b)(e) CFR 47 FCC §15.205 and §15.209 RSS-210 Annex A.1.2 RSS-GEN Clause 8.9 RSS-GEN Clause 8.10 Pass 4 Conducted Emission Test for AC Power Port CFR 47 FCC §15.207 RSS-GEN Clause 8.8 N/A (See Note 1) 5 Antenna Requirement CFR 47 FCC §15.203 ISED RSS-Gen Clause 6.8 Pass Note 1: The product was powered by battery, so this test item is no need to test. Note 2: The measurement result for the sample received is < Pass > according to < ANSI C63.10-2013, FCC CFR 47 Part 2, FCC CFR 47 Part 15C, ISED RSS-210 Issue 10 and ISED RSS-Gen Issue 5 > when < Simple Acceptance > decision rule is applied. Report No.: 4791417323-1 Page 4 of 39 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 5 2. TEST METHODOLOGY ..................................................................................................... 7 3. FACILITIES AND ACCREDITATION ................................................................................. 7 4. CALIBRATION AND UNCERTAINTY ................................................................................ 8 4.1. MEASURING INSTRUMENT CALIBRATION ............................................................... 8 4.2. MEASUREMENT UNCERTAINTY................................................................................ 8 5. EQUIPMENT UNDER TEST ............................................................................................... 9 5.1. DESCRIPTION OF EUT ............................................................................................... 9 5.2. MAXIMUM FIELD STRENGTH ..................................................................................... 9 5.3. TEST CHANNEL CONFIGURATION ............................................................................ 9 5.4. DESCRIPTION OF AVAILABLE ANTENNAS ..............................................................10 5.5. TEST ENVIRONMENT ................................................................................................10 5.6. DESCRIPTION OF TEST SETUP ...............................................................................11 5.7. MEASURING INSTRUMENT AND SOFTWARE USED ..............................................12 6. ANTENNA PORT TEST RESULTS ...................................................................................13 6.1. ON TIME AND DUTY CYCLE ......................................................................................13 6.2. TANSMITTER TIMEOUT .............................................................................................16 6.3. 20dB BANDWIDTH .....................................................................................................19 7. RADIATED TEST RESULTS .............................................................................................22 7.1. FIELD STRENGTH OF INTENTIONAL EMISSIONS ...................................................30 7.2. SPURIOUS EMISSIONS (1~6GHz) .............................................................................32 7.3. SPURIOUS EMISSIONS (0.03~1 GHz) .......................................................................34 7.4. SPURIOUS EMISSIONS BELOW 30M .......................................................................36 8. ANTENNA REQUIREMENTS ............................................................................................39 Report No.: 4791417323-1 Page 5 of 39 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Suzhou Lishen Energy Science & Technology Co., Ltd. Address: Room 301-1, Floor 3, Plant Building 4, No.588 Wutaishan Road, High-tech Zone, Suzhou City, Jiangsu Province, China Manufacturer Information Company Name: Suzhou Lishen Energy Science & Technology Co., Ltd. Address: Room 301-1, Floor 3, Plant Building 4, No.588 Wutaishan Road, High-tech Zone, Suzhou City, Jiangsu Province, China Factory Information Company Name: Suzhou Lishen Energy Science & Technology Co., Ltd. Address: Room 301-1, Floor 3, Plant Building 4, No.588 Wutaishan Road, High-tech Zone, Suzhou City, Jiangsu Province, Chin…
Text truncated - open the document above for the full version.
Appendix III Setup Photographs RADIATED RF MEASUREMENT SETUP (9kHz ~ 30 MHz) RADIATED RF MEASUREMENT SETUP (30MHz ~ 1 GHz - X axis) RADIATED RF MEASUREMENT SETUP (30MHz ~ 1 GHz - Y axis) RADIATED RF MEASUREMENT SETUP (30MHz ~ 1 GHz - Z axis) RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz - Z axis)
Building 10, Innovation Technology Park, No. 1, Li · dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |