Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BK3Y-WL4BACTRL WL4BACTRLCN/G2 We, Applicant Company Name: Nanjing Weilan Intelligent Technology Co., Ltd Address: 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Phone: +86-13382789985 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-12-03 Signature Date Name / Title: Yawei Wu / HW Test Manager Company: Nanjing Weilan Intelligent Technology Co., Ltd Address: 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Phone: +86-13382789985 Fax: N/A E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BK3Y-WL4BACTRL WL4BACTRLCN/G2 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-12-03 Signature Date Name / Title: Yawei Wu / HW Test Manager Company: Nanjing Weilan Intelligent Technology Co., Ltd Address: 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Phone: +86-13382789985 Fax: N/A E-Mail: [email protected]
Page 1 of 3 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6
Page 1 of 1 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L2.0cm x 1.0cm) Label Location Remote Controller Model: WL4BACTRLCN/G2 FCC ID:2BK3Y-WL4BACTRL
Page 1 of 4 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 BT ANT Page 4 of 4 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 3 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2BK3Y-WL4BACTRL Product name : Remote Controller Test Model : WL4BACTRLCN/G2 Power Supply : DC 3.0 by 2*AAA battery Hardware Version : / Software Version : / Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0(DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Type : Internal Antenna Antenna Gain : 1.50dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device Date of Test : November 01, 2024 ~ November 15, 2024 Date of Report : November 18, 2024 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison Page 2 of 3 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results < BLE 1M > Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.77 19 2440 0.79 39 2480 -0.28 < BLE 2M > Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.85 19 2440 0.63 39 2480 -0.45 5. Manufacturing Tolerance < BLE 1M > GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 Page 3 of 3 FCC ID:2BK3Y-WL4BACTRL Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmas…
Text truncated - open the document above for the full version.
Nanjing WEILAN Intelligent Technology Co., Ltd. 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Frequency(MHz)EfficiencyAverage gainRequirement(dBi)ResultPeak gainRequirementResult 2400 38.87%-3.261.36 2410 38.88%-3.161.39 2420 39.44%-3.131.43 2430 40.35%-3.071.44 2440 40.12%-3.051.46 2450 40.32%-2.991.49 2460 40.66%-2.991.45 2470 40.43%-2.951.48 2480 40.34%-2.941.49 2490 40.76%-2.971.49 2500 40.79%-2.981.50 1.5PF Element 3. Radiated pattern 2.4NHL3 C41 Chip Antenna 1# 1. Macting & Photo E1E2H C72 C40 2. Efficiency&Gain Value 220PF 2PF Nanjing WEILAN Intelligent Technology Co., Ltd. 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China
Page 1 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT LE (Conducted Measurement) Product Name: Remote Controller Test Model: WL4BACTRLCN/G2 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.3% ATM Pressure: 100.0 kPa Test Engineer: Can Kun Supervised by: Nick Peng Page 2 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant 0.649 >=0.5 Pass NVNT BLE 1M 2440 Ant 0.651 >=0.5 Pass NVNT BLE 1M 2480 Ant 0.661 >=0.5 Pass NVNT BLE 2M 2402 Ant 1.152 >=0.5 Pass NVNT BLE 2M 2440 Ant 1.183 >=0.5 Pass NVNT BLE 2M 2480 Ant 1.165 >=0.5 Pass Page 3 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant -6dB Bandwidth NVNT BLE 1M 2440MHz Ant Page 4 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant -6dB Bandwidth NVNT BLE 2M 2402MHz Ant Page 5 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 2M 2440MHz Ant -6dB Bandwidth NVNT BLE 2M 2480MHz Ant Page 6 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant -0.77 30 Pass NVNT BLE 1M 2440 Ant 0.79 30 Pass NVNT BLE 1M 2480 Ant -0.28 30 Pass NVNT BLE 2M 2402 Ant -0.85 30 Pass NVNT BLE 2M 2440 Ant 0.63 30 Pass NVNT BLE 2M 2480 Ant -0.45 30 Pass Page 7 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant Power NVNT BLE 1M 2440MHz Ant Page 8 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant Power NVNT BLE 2M 2402MHz Ant Page 9 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 2M 2440MHz Ant Power NVNT BLE 2M 2480MHz Ant Page 10 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant -17.26 8 Pass NVNT BLE 1M 2440 Ant -15.68 8 Pass NVNT BLE 1M 2480 Ant -16.9 8 Pass NVNT BLE 2M 2402 Ant -20.54 8 Pass NVNT BLE 2M 2440 Ant -19.24 8 Pass NVNT BLE 2M 2480 Ant -20.12 8 Pass Page 11 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant PSD NVNT BLE 1M 2440MHz Ant Page 12 of 34 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to c…
Text truncated - open the document above for the full version.
Page 1 of 32 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Nanjing WEILAN Intelligent Technology Co., Ltd. Remote Controller Test Model: WL4BACTRLCN/G2 Prepared for : Nanjing WEILAN Intelligent Technology Co., Ltd. Address : 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : November 01, 2024 Number of tested samples : 2 Sample No. : A241031078-1, A241031078-2 Serial number : Prototype Date of Test : November 01, 2024 ~ November 15, 2024 Date of Report : November 18, 2024 Page 2 of 32 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA10314131EA Date of Issue ................................... : November 18, 2024 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location Procedure ............ : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Nanjing WEILAN Intelligent Technology Co., Ltd. Address ........................................... : 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Test Specification Standard .......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ................... : TRF-4-E-145 A0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Remote Controller Trade Mark ...................................... : WEILAN Test Model ...................................... : WL4BACTRLCN/G2 Ratings ............................................ : DC 3.0 by 2*AAA battery Result ........................................... : Positive Compiled by: Supervised by: Approved by: Jack Liu/Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 32 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : WL4BACTRLCN/G2 EUT......................................... : Remote Controller Applicant............................... : Nanjing WEILAN Intelligent Technology Co., Ltd. Address.................................. : 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Telephone............................... : / Fax.......................................... : / : Manufacturer........................ : Nanjing WEILAN Intelligent Technology Co., Ltd. Address................................... : 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Telephone............................... : / Fax.......................................... : / : Factory................................... : Nanjing WEILAN Intelligent Technology Co., Ltd. Address................................... : 20F, Building B2, Jingfenglechuang, No.68, Huachuang Road, Pukou District, Nanjing City, Jiangsu Province, China Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA10314131EA November 18, 2024 Date of issue Page 4 of 32 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 November 18, 2024 Initial Issue -- Page 5 of 32 FCC ID:2BK3Y-WL4BACTRL Report No.: LCSA10314131EA Shenzhen LCS Compliance Tes…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |