2BK7P-G2000AOA Locator

NuboMed LLC
AOA Locator - FCC ID 2BK7P-G2000 - NuboMed LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 01, 2025
Application Purpose
Original Equipment
Equipment Note
AOA Locator
Frequency Range
2402.00000000 - 2480.00000000
Company
NuboMed LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

- 1 - AOA Locator G2000 Product Specification Release Date: 2024-11-14 - 2 - Introduction Thank you for using the products of Smart medical IoT system produced by NuboMed LLC. NuboMed smart medical IoT system integrates the information of patients and equipment with the hospital platform, integrates the new IOT Smart vital signs monitoring equipment with other manufacturers to digitize patient data, realizes the whole process of health monitoring and management of patients from hospital surgery to ward care, meets the process and standards of smart hospital construction, improves the work process, reduces the work burden of medical staff, and improves the quality of medical service. This user manual can be used as a material for the training operation and reference of the product model equipment of this IoT system. -3 - Catalog I.Important Instruction ............................................................................................ - 4 - 1.1 Statement ................................................................................................................................. - 4 - 1.2 Service Environment................................................................................................................ - 4 - 1.3 Configuration .......................................................................................................................... - 4 - II.Product Introduction .......................................................................................... - 5 - 2.1 Specification ............................................................................................................................. - 5 - 2.2 Work status description .......................................................................................................... - 7 - 2.3 Installation instructions................................................................................................................. - 7 - 2.4 Explanation of the key components.......................................................................................... - 7 - III.Common fault ..................................................................................................... - 8 - IV.Matters need attention ...................................................................................... - 8 - 4.1 Precautions ............................................................................................................................... - 8 - 4.2 Use the pre-test ....................................................................................................................... - 9 - V.Cl ean instructions ............................................................................................... - 9 - VI. Service Commitment .......................................................................................... - 9 - -4 - I. Important Instruction 1.1 Statement Before operating the configuration and use of the IoT devices, please read this manual carefully. Special attention should be given to the safety guidance. These smart IoT devices are considered illegal for any other purposes other than this description. Smart IoT devices and software systems can only be operated by trained personnel, and can only be used for the contents specified in this manual and operated according to the instructions in the manual. Please maintain and maintain the equipment according to the maintenance instructions in this manual; the equipment can only be repaired by Shenzhen NuboMed Medical Device Co., Ltd. or its authorized service personnel. Please do not install this equipment near the electromagnetic interference source. Do not change the software and hardware settings of this device. Due to the constantly updated products, Shenzhen NuboMed Medical Device Co., Ltd. will retain the right to change the technical specifications without notice. 1.2 Service Environment (1)Ambient temperature of equipment installation: 0~40°C. (2)Relative humidity for equipment installation: 10~90% (no condensation). (3)The existence of explosive dangerous medium is not allowed in the place of use, and the surrounding medium should not contain the gas and conductive medium that corrode the metal and destroy the insulation. (4)The place of use shall have protective facilities against rain, snow, wind, sand, and ash. 1.3 Configuration No. Name unit 1 Smart Gateway Host 1 2 Gateway fixing structure floor and fixing screws 1 Note: For DC power supply mode, provide NuboMed specified power adapter product. -5 - II.Product Introduction 2.1 Specification Order Number Component Name Sub Modular Specification Parameters 1 Physical Spec Dimensions 200 x40mm, diameter Weight ≤420g 2 Technical Spec Processor Dual-core ARM Cortex-A7, Integrated FPU、NPU. RAM DDR3 1GB ROM 4GB eMMC Bluetooth tech BLE5.3 BLE data rates 2Mbps/1Mbps/125kbps BLE Frequency 2.400~2.483GHz 3 Interface Ethernet Ports 1x RJ45 Key Reset 4 Power Supply DC 12VDC, 1A 5 FCC FCC ID 2BK7P-G1100 - 6 - 2.2 Work status description Operative mode Green light is always on: normal working condition; Blue light flashing: network disconnected or network abnormal, is connected to the network status; Red constant light: equipment failure; When the power is dropped, broadcast the voice reminder user, continuously broadcast for 5 seconds, and the white light flicker reminder; 2.3 Installation instructions The product installation can be roughly divided into the following steps: (1)Fix the base of the gateway to the roof ceiling of the ward, corridor or office; (2)The corresponding gateway power supply and communication mode adopts POE mode, the position is next to the gateway base, refer to the diagram; I ntelligent gateway base installation signal (1)Scan the code and mark the gateway through PDA and other tools; (2)Card the gateway terminal into the installed base and plug in the POE network cable; (3)Configure each gateway IP as a fixed IP address; 2.4 Explanation of…

Text truncated - open the document above for the full version.

Users Manual

- 1 - AOA Locator G2000 Product Specification Release Date: 2024-11-14 - 2 - Introduction Thank you for using the products of Smart medical IoT system produced by NuboMed LLC. NuboMed smart medical IoT system integrates the information of patients and equipment with the hospital platform, integrates the new IOT Smart vital signs monitoring equipment with other manufacturers to digitize patient data, realizes the whole process of health monitoring and management of patients from hospital surgery to ward care, meets the process and standards of smart hospital construction, improves the work process, reduces the work burden of medical staff, and improves the quality of medical service. This user manual can be used as a material for the training operation and reference of the product model equipment of this IoT system. -3 - Catalog I.Important Instruction ............................................................................................ - 4 - 1.1 Statement ................................................................................................................................. - 4 - 1.2 Service Environment................................................................................................................ - 4 - 1.3 Configuration .......................................................................................................................... - 4 - II.Product Introduction .......................................................................................... - 5 - 2.1 Specification ............................................................................................................................. - 5 - 2.2 Work status description .......................................................................................................... - 7 - 2.3 Installation instructions................................................................................................................. - 7 - 2.4 Explanation of the key components.......................................................................................... - 7 - III.Common fault ..................................................................................................... - 8 - IV.Matters need attention ...................................................................................... - 8 - 4.1 Precautions ............................................................................................................................... - 8 - 4.2 Use the pre-test ....................................................................................................................... - 9 - V.Cl ean instructions ............................................................................................... - 9 - VI. Service Commitment .......................................................................................... - 9 - -4 - I. Important Instruction 1.1 Statement Before operating the configuration and use of the IoT devices, please read this manual carefully. Special attention should be given to the safety guidance. These smart IoT devices are considered illegal for any other purposes other than this description. Smart IoT devices and software systems can only be operated by trained personnel, and can only be used for the contents specified in this manual and operated according to the instructions in the manual. Please maintain and maintain the equipment according to the maintenance instructions in this manual; the equipment can only be repaired by Shenzhen NuboMed Medical Device Co., Ltd. or its authorized service personnel. Please do not install this equipment near the electromagnetic interference source. Do not change the software and hardware settings of this device. Due to the constantly updated products, Shenzhen NuboMed Medical Device Co., Ltd. will retain the right to change the technical specifications without notice. 1.2 Service Environment (1)Ambient temperature of equipment installation: 0~40°C. (2)Relative humidity for equipment installation: 10~90% (no condensation). (3)The existence of explosive dangerous medium is not allowed in the place of use, and the surrounding medium should not contain the gas and conductive medium that corrode the metal and destroy the insulation. (4)The place of use shall have protective facilities against rain, snow, wind, sand, and ash. 1.3 Configuration No. Name unit 1 Smart Gateway Host 1 2 Gateway fixing structure floor and fixing screws 1 Note: For DC power supply mode, provide NuboMed specified power adapter product. -5 - II.Product Introduction 2.1 Specification Order Number Component Name Sub Modular Specification Parameters 1 Physical Spec Dimensions 200 x40mm, diameter Weight ≤420g 2 Technical Spec Processor Dual-core ARM Cortex-A7, Integrated FPU、NPU. RAM DDR3 1GB ROM 4GB eMMC Bluetooth tech BLE5.3 BLE data rates 2Mbps/1Mbps/125kbps BLE Frequency 2.400~2.483GHz 3 Interface Ethernet Ports 1x RJ45 Key Reset 4 Power Supply DC 12VDC, 1A 5 FCC FCC ID 2BK7P-G1100 - 6 - 2.2 Work status description Operative mode Green light is always on: normal working condition; Blue light flashing: network disconnected or network abnormal, is connected to the network status; Red constant light: equipment failure; When the power is dropped, broadcast the voice reminder user, continuously broadcast for 5 seconds, and the white light flicker reminder; 2.3 Installation instructions The product installation can be roughly divided into the following steps: (1)Fix the base of the gateway to the roof ceiling of the ward, corridor or office; (2)The corresponding gateway power supply and communication mode adopts POE mode, the position is next to the gateway base, refer to the diagram; I ntelligent gateway base installation signal (1)Scan the code and mark the gateway through PDA and other tools; (2)Card the gateway terminal into the installed base and plug in the POE network cable; (3)Configure each gateway IP as a fixed IP address; 2.4 Explanation of…

Text truncated - open the document above for the full version.

ID Label/Location Info

Label Location: 17mm*35mm

Test Setup Photos

ProjectNo.:1812C400533125Page1of2 AppendixI--TestSetupPhotograph_RF ConductedEmissionatACpowerline Emissionsinfrequencybands(below1GHz) ProjectNo.:1812C400533125Page2of2 Emissionsinfrequencybands(above1GHz)

Test Report

ANTENNASPECIFICATION Summary ITEMAOALocatorANTSPEC ModelName2.4GANT Center Frequency 2400MHz2450MHz2500MHz 1.011.442 MAX.Gain(dBi)2 AzimuthBeam Pattern Omni-directional Impedance50Ohm AntennaLength165mm Manufactures ShenzhenNuboMedEquipmentCo.,Ltd. ANTShapeFPC AntennaPhoto&Length(mm) ANT Frequency (MHz) Gain(dBi) MaxMin 24001.01-6.14 24501.44-5.67 25002-5.03

Test Report

ReportNo.:1812C40053312501Page1of30 FCCID:2BK7P-G2000 FCCTestReport Applicant:NuboMedLLC Address: 16192CoastalHighway,Lewes,Delaware19958, USA ProductName:AOALocator ReportDate:Dec.19,2024 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:1812C40053312501Page2of30 FCCID:2BK7P-G2000 Contents 1.GeneralInformation.................................................................................................................................6 1.1.ClientInformation...........................................................................................................................6 1.2.DescriptionofDevice(EUT)..........................................................................................................6 1.3.AuxiliaryEquipmentUsedDuringTest..........................................................................................7 1.4.Operationchannellist....................................................................................................................7 1.5.DescriptionofTestModes.............................................................................................................7 1.6.MeasurementUncertainty.............................................................................................................8 1.7.TestSummary................................................................................................................................8 1.8.DescriptionofTestFacility.............................................................................................................9 1.9.Disclaimer......................................................................................................................................9 1.10.TestEquipmentList...................................................................................................................10 2.Antennarequirement..............................................................................................................................12 2.1.Conclusion...................................................................................................................................12 3.ConductedEmissionatACpowerline..................................................................................................13 3.1.EUTOperation.............................................................................................................................13 3.2.TestSetup....................................................................................................................................13 3.3.TestData......................................................................................................................................14 4.OccupiedBandwidth..............................................................................................................................16 4.1.EUTOperation.............................................................................................................................16 4.2.TestSetup....................................................................................................................................16 4.3.TestData......................................................................................................................................16 5.MaximumConductedOutputPower......................................................................................................17 5.1.EUTOperation.............................................................................................................................17 5.2.TestSetup....................................................................................................................................17 5.3.TestData......................................................................................................................................17 6.PowerSpectralDensity..........................................................................................................................18 6.1.EUTOperation.............................................................................................................................18 6.2.TestSetup....................................................................................................................................18 6.3.TestData......................................................................................................................................18 7.Emissionsinnon-restrictedfrequencybands.......................................................................................19 7.1.EUTOperation.............................................................................................................................19 7.2.TestSetup....................................................................................................................................19 7.3.TestData......................................................................................................................................19 8.Bandedgeemissions(Radiated)..........................................................................................................20 8.1.EUTOperation.............................................................................................................................20 8.2.TestSetup....................................................................................................................................20 8.3.TestData......................................................................................................................................21 9.Emissionsinfrequencybands(below1GHz).......................................................................................22 9.1.EUTOperation.............................................................................................................................22 9.2.TestSetup..............................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page1of15 AppendixTestData ReportNo.:1812C40053312501TestSampleNo.:1-2-2 StartTestDate:2024.9.11FinishTestDate:2024.9.11 TestEngineer:Auditor: Temperature:22.1 °C RelativeHumidity:54% Pressure:101kPa AppendixA:-6dBBandwidth ConditionAntennaRateFrequency(MHz)-6dBBW(kHz)limit(kHz)Result NVNTANT11Mbps2402.00663.20500Pass NVNTANT11Mbps2440.00658.73500Pass NVNTANT11Mbps2480.00669.70500Pass -6dB_Bandwidth_NVNT_ANT1_1Mbps_2402 Page2of15 -6dB_Bandwidth_NVNT_ANT1_1Mbps_2440 -6dB_Bandwidth_NVNT_ANT1_1Mbps_2480 Page3of15 AppendixB:99%OccupiedBandwidth ConditionAntennaRateFrequency(MHz)99%%BW(MHz) NVNTANT11Mbps2402.001.029 NVNTANT11Mbps2440.001.036 NVNTANT11Mbps2480.001.030 99%_Occupied_Bandwidth_NVNT_ANT1_1Mbps_2402 99%_Occupied_Bandwidth_NVNT_ANT1_1Mbps_2440 Page4of15 99%_Occupied_Bandwidth_NVNT_ANT1_1Mbps_2480 Page5of15 AppendixC:DutyCycle ConditionAntennaRateFrequency(MHz)Dutycycle(%)Duty_factor NVNTANT11Mbps2402.0064.521.90 NVNTANT11Mbps2440.0064.521.90 NVNTANT11Mbps2480.0064.521.90 Duty_Cycle_NVNT_ANT1_1Mbps_2402 Duty_Cycle_NVNT_ANT1_1Mbps_2440 Page6of15 Duty_Cycle_NVNT_ANT1_1Mbps_2480 Page7of15 AppendixD:PeakOutputPower ConditionAntennaRate Frequency (MHz) Max.Conducted Power(dBm) Max.Conducted Power(mW) Limit(mW)Result NVNTANT11Mbps2402.00-1.650.681000Pass NVNTANT11Mbps2440.00-1.450.721000Pass NVNTANT11Mbps2480.00-1.630.691000Pass Peak_Output_Power_NVNT_ANT1_1Mbps_2402 Page8of15 Peak_Output_Power_NVNT_ANT1_1Mbps_2440 Peak_Output_Power_NVNT_ANT1_1Mbps_2480 Page9of15 AppendixE:PowerSpectralDensity ConditionAntennaRate Frequency (MHz) PowerSpectral Density(dBm) Limit(dBm/3kHz)Result NVNTANT11Mbps2402.00-17.068Pass NVNTANT11Mbps2440.00-17.688Pass NVNTANT11Mbps2480.00-16.398Pass Power_Spectral_Density_NVNT_ANT1_1Mbps_2402 Page10of15 Power_Spectral_Density_NVNT_ANT1_1Mbps_2440 Power_Spectral_Density_NVNT_ANT1_1Mbps_2480 Page11of15 AppendixF:Bandedge ConditionAntennaRate TX_Frequency (MHz) Max.Mark Frequency(MHz) Spurious level(dBm) limit(dBm)Result NVNTANT11Mbps2402.002399.965-60.683-21.806Pass NVNTANT11Mbps2480.002495.450-63.253-21.812Pass 1_Reference_Level_NVNT_ANT1_1Mbps_2402 2_Bandedge_NVNT_ANT1_1Mbps_2402 Page12of15 1_Reference_Level_NVNT_ANT1_1Mbps_2480 2_Bandedge_NVNT_ANT1_1Mbps_2480 Page13of15 AppendixG:SpuriousEmission ConditionAntennaRateTX_Frequency(MHz) Spurious MAX.Value(dBm) LimitResult NVNTANT11Mbps2402.00-50.635-21.806Pass NVNTANT11Mbps2440.00-50.704-21.605Pass NVNTANT11Mbps2480.00-51.367-21.811Pass 1_Reference_Level_NVNT_ANT1_1Mbps_2402 2_Spurious_Emission_NVNT_ANT1_1Mbps_2402 Page14of15 1_Reference_Level_NVNT_ANT1_1Mbps_2440 2_Spurious_Emission_NVNT_ANT1_1Mbps_2440 Page15of15 1_Reference_Level_NVNT_ANT1_1Mbps_2480 2_Spurious_Emission_NVNT_ANT1_1Mbps_2480 ---END---

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2BK7P-G2000 AccordingtoKDB447498D01MobileandPortableDevicesRFExposureProcedures andEquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationas specifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnotrequired, portabletransmitterswithoutputpowergreaterthantheapplicablelowthresholdrequire SARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 2402-1.65-1.65±1-0.65050.2673 BLE_1M2440-1.45-1.45 ± 1-0.45050.2823 2480-1.63-1.63±1-0.63050.2723 Result:NoStandaloneSARtestisrequired.

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2BK7P-G2000 AccordingtoKDB447498D01MobileandPortableDevicesRFExposureProcedures andEquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationas specifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnotrequired, portabletransmitterswithoutputpowergreaterthantheapplicablelowthresholdrequire SARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 2402-1.65-1.65±1-0.65050.2673 BLE_1M2440-1.45-1.45 ± 1-0.45050.2823 2480-1.63-1.63±1-0.63050.2723 Result:NoStandaloneSARtestisrequired.

Internal Photos

ProjectNo.:1812C400533125Page1of6 AppendixIII--InternalPhotograph ProjectNo.:1812C400533125Page2of6 ProjectNo.:1812C400533125Page3of6 ProjectNo.:1812C400533125Page4of6 ProjectNo.:1812C400533125Page5of6 ProjectNo.:1812C400533125Page6of6 ANT

Attestation Statements

NuboMedLLC 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:NuboMedLLC Address:16192CoastalHighway,Lewes,Delaware19958,USA ProductName:AOALocator FCCID:2BK7P-G2000 Model(s):G2000,G2000xxx(The1stto3thx’srepresentthelettersA~Zora~zorablankspace) 2.911(d)(5)(i)EquipmentType We,[NuboMedLLC]certifythattheequipmentforwhichauthorizationissoughtthroughcertification isnot:  Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules.  Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:WeiKangChenDate:2024-12-19 TitleandCompanyname:SalesDirector/NuboMedLLC NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

ID Label/Location Info

Label Location: 17mm*35mm

External Photos

ProjectNo.:1812C400533125Page1of4 AppendixII--ExternalPhotograph ProjectNo.:1812C400533125Page2of4 ProjectNo.:1812C400533125Page3of4 ProjectNo.:1812C400533125Page4of4

Cover Letter(s)

NuboMedLLC DeclarationonModelDifferences We, NuboMedLLC 16192CoastalHighway,Lewes,Delaware19958,USA Declarethatthefollowingproduct(s): FCCID:2BK7P-G2000 ProductName:AOALocator ModelNo.:G2000,G2000xxx(The1stto3thx’srepresentthelettersA~Zora~zorablank space) Utilizetheidenticalcircuitdesign,PCBlayout,shieldingandinterfacewith(G2000),onlythe modelnumberdifferent.Thereforethisapplicationcanberegardedasidenticalin performancetothesubmittedtestsample. Themanufacturerwouldtakealltheresponsibilitiesfortheaboveproduct(s). Forandonbehalfof Authorizedperson Name:WeiKangChen Position:SalesDirector Dateofissue:2024-12-23 *IherebydeclarethatIamentitledtosignonbehalfoftheapplicantandthattheinformationsuppliediscorrectandcomplete.

Cover Letter(s)

NuboMedLLC DeclarationonModelDifferences We, NuboMedLLC 16192CoastalHighway,Lewes,Delaware19958,USA Declarethatthefollowingproduct(s): FCCID:2BK7P-G2000 ProductName:AOALocator ModelNo.:G2000,G2000xxx(The1stto3thx’srepresentthelettersA~Zora~zorablank space) Utilizetheidenticalcircuitdesign,PCBlayout,shieldingandinterfacewith(G2000),onlythe modelnumberdifferent.Thereforethisapplicationcanberegardedasidenticalin performancetothesubmittedtestsample. Themanufacturerwouldtakealltheresponsibilitiesfortheaboveproduct(s). Forandonbehalfof Authorizedperson Name:WeiKangChen Position:SalesDirector Dateofissue:2024-12-23 *IherebydeclarethatIamentitledtosignonbehalfoftheapplicantandthattheinformationsuppliediscorrectandcomplete.

Cover Letter(s)

NuboMedLLC OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024-12-19 Subject;RequestforConfidentiality FCCID:2BK7P-G2000 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription SWSECURITYDESCRIPTION PartsList Tuneup Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. NuboMedLLC Sincerely, Signature: Name:WeiKangChen Title:SalesDirector

Cover Letter(s)

NuboMedLLC AgentAuthorization Company:NuboMedLLC Address:16192CoastalHighway,Lewes,Delaware19958,USA ProductName:AOALocator ModelNumber(s):G2000,G2000xxx(The1stto3thx’srepresentthelettersA~Zor a~zorablankspace) ProductDescription:AOALocator WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2024-12-19 Name:WeiKangChen Title:SalesDirector Company:NuboMedLLC

Attestation Statements

NuboMedLLC 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:NuboMedLLC Address:16192CoastalHighway,Lewes,Delaware19958,USA ProductName:AOALocator FCCID:2BK7P-G2000 Model(s):G2000,G2000xxx(The1stto3thx ’ srepresentthelettersA~Zora~zora blankspace) 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[NuboMedLLC]designate[NuboMedLLC] NOTE1 forthepurposeofaccepting serviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgentApplicant Companyname:NuboMedLLCCompanyname:NuboMedLLC USAAddress:16192CoastalHighway, Lewes,Delaware19958,USA Address:16192CoastalHighway,Lewes, Delaware19958,USA FRNNumber:0033751041GranteeFRNNumber:0033751041 ContactName:WeiKangChenFCCGranteeCode:2BK7P TelephoneNo:562-787-8179ContactName:WeiKangChen Email:[email protected]…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Wei Kang Chen(Sales Director)
[email protected]Fax: /

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz700.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.