FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Alan Safety Company Limited/
  3. 2BK98KP362

2BK98KP362VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM

Alan Safety Company Limited
VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM - FCC ID 2BK98KP362 - Alan Safety Company Limited
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Oct 07, 2024
Application Purpose
Original Equipment
Date of Application
Oct 06, 2024
Equipment Note
VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM
Frequency Range
2402.00000000 - 2480.00000000
Company
Alan Safety Company Limited
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM Product Name: voice tracking sounds amplifying system Main Model: KP362 Applicant: ALAN-SAFETY CO., LTD. Address: No. 36, Aly. 38, Ln. 288, Sec. 1, Heshun Rd., Mamiao Vil., Guiren Dist., Tainan City 711003, Taiwan (R.O.C.) SPEC Bluetooth Version : V5.0 INPUT: 5V/1A BATTERY: 3.7V 600mAh Operation mode: Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation of the device. FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09-27-2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2BK98KP362 ALAN SAFETY COMPANY LIMITED (“the applicant”) certifies that, as of the date of the filing of the application, TianHeng Consulting, LLC is our designated U.S. agent for service of process for the above referenced FCC ID.ALAN SAFETY COMPANY LIMITED accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. TianHeng Consulting, LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Sincerely, Designated U.S. Agent Information: Name: TianHeng Consulting, LLC FRN: 0033401258 Contact Person: Yingzhi Chen Address: 30 N Gould St Ste 44116, Sheridan, WY 82801, United States Tel.: +1 307-291-9708 Email: [email protected] U.S. Agent Signature: Applicant: Company Name: ALAN SAFETY COMPANY LIMITED Grantee Code: 2BK98 FRN: 0035983287 Contact Name: Mr. Andy Chen Address:No.36, Alley 38, Lane 288, Heshun Rd. Sec.1 Guiren Dist., Tainan City, 71145, Taiwan(R.O.C.) Tel.:+88662739975 Email:[email protected] Applicant Signature:

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Certification Application Attestation Statements ALAN SAFETY COMPANY LIMITED No.36, Alley 38, Lane 288, Heshun Rd. Sec.1 Guiren Dist., 71145 Tainan City, Taiwan (R.O.C.) Subject: FCC ID: 2BK98KP362 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) [ALAN SAFETY COMPANY LIMITED] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [ALAN SAFETY COMPANY LIMITED] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2024/10/4 City: Tainan City Name (2) : Mr. Andy Chen Function: Product Manager Telephone number: +88662739975 Email address: [email protected] 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_02 15-02-2023 Signature: Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-20231 st version RvM 02 1 15-02-2023Changed Applicant to Company and added “Subject: FCC ID: “ RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 16-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 19-02-2023

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Declaration of Authorization We Name: ALAN SAFETY COMPANY LIMITED Address: No.36, Alley 38, Lane 288, Heshun Rd. Sec.1 Guiren Dist., City: Tainan City, 71145 Country: Taiwan(R.O.C.) Declare that: Name Representative of agent: ............. (1) Agent Company name: International Standards Laboratory Corp. Address: No. 120, Lane 180, Hsin Ho Rd., Lung-Tan Dist., City: Tao Yuan City 325. Country Taiwan is authorized to apply for Certification of the following product(s): Product description: VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM Type designation: KP362  Trademark: ALAN Validity/ expiry date on our behalf. Date: 2024/09/27.. City: Tainan City .. Name: Mr. Andy Chen .. (2) Function: Product Manager............................... Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent. Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 02 1 02-01-2023 History sheet added AG Issued/modified by : Axel Gase Function : Quality Manager Revision : 02 Date : 02-01-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 02-01-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 02-01-2023

Cover Letter(s)

FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: ALAN SAFETY COMPANY LIMITED Address: No.36, Alley 38, Lane 288, Heshun Rd. Sec.1 Guiren Dist., City: Tainan City, 71145 Country: Taiwan (R.O.C.) To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2BK98KP362 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 2024/09/27 Name and signature of applicant: Mr. Andy Chen Product Manager Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 02-01-2023 RF_501, Issue 10 Page 1 of 1 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 10 1 02-01-2023 History sheet added AG Issued/modified by : Axel Gase Function : Quality Manager Revision : 10 Date : 02-01-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 02-01-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 02-01-2023

External Photos

International Standards Laboratory Corp. Report Number: ISL-24LR0127P Appendix Photographs of EUT of Product Name VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM Main Model KP362 Series Model NA Brand ALAN International Standards Laboratory Corp. Report Number: ISL-24LR0127P -1- EUT-1. EUT-2. International Standards Laboratory Corp. Report Number: ISL-24LR0127P -2- EUT-3. EUT-4. International Standards Laboratory Corp. Report Number: ISL-24LR0127P -3- EUT-5. EUT-6. International Standards Laboratory Corp. Report Number: ISL-24LR0127P -4- EUT-7.

ID Label/Location Info

FCC ID LABEL FORMAT AND LOCATION Applicant: ALAN SAFETY COMPANY LIMITED FCC ID: 2BK98KP362

Internal Photos

International Standards Laboratory Corp. Report Number: ISL-24LR0127P Appendix Photographs of EUT of Product Name VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM Main Model KP362 Series Model NA Brand ALAN International Standards Laboratory Corp. Report Number: ISL-24LR0127P -1- EUT-1. EUT-2. International Standards Laboratory Corp. Report Number: ISL-24LR0127P -2- EUT-3. EUT-4. International Standards Laboratory Corp. Report Number: ISL-24LR0127P -3- EUT-5. EUT-6. Antenna International Standards Laboratory Corp. Report Number: ISL-24LR0127P -4- EUT-7. Module EUT-8. Battery International Standards Laboratory Corp. Report Number: ISL-24LR0127P -5- EUT-9. Battery

RF Exposure Info

FCC: 2BK98KP362 International Standards Laboratory Maximum Permissible Exposure (MPE) Standard Applicable For The radiation source included into the device the output power is taken from a corresponding RF test report. If needed the output power is converted to source based, time – average out power. Finally the output power is compared to FCC and IC low power SAR evaluation exemption level. According to §2.1093 this is a Portable device. FCC SAR test exclusion: According to KDB 447498 D01 General RF Exposure Guidance v06, Appendix A requirement, “The equation and threshold in section 4.3.1 must be applied to determine SAR test exclusion.” 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.23 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.24 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ꞏ [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,25 where FCC: 2BK98KP362 International Standards Laboratory • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation26 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. Evaluation Result: FCC: Frequency (MHz) Output Power (dBm) Antenna Gain (dBi) EIRP (dBm) Tune-up Tolerance (dB) Max Power (mW) Min Distance (mm) Result Limit (3.0 @ 1g SAR) 2480 8.27 -3.77 4.50 1 3.55 5.00 1.12 3.0 Max Power(mW) =10^((Max Power(dBm) + Tune-up tolerance(dB) )/10) Result = Max Power (mW) / min. distance(mm) * √f(GHz) ~ End of Report ~

Test Report

Page: 1 of 8 ANTENNA TEST REPORT Product : Monopole antenna Brand: ALAN Model: KP362-ANT Model Difference: N/A Applicant: ALAN SAFETY COMPANY LIMITED Address: No.36, Alley 38, Lane 288, Heshun Rd. Sec.1 Guiren Dist., Tainan City, 71145, Taiwan(R.O.C.) Test Performed by: International Standards Laboratory <LT Lab.> *Address: No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd. Lung-Tan Hsiang, Tao Yuan County 325, Taiwan *Tel : 886-3-407-1718; Fax: 886-3-407-1738 Report No.: ISL-24LR0127ANT Issue Date : 2024/09/04 Test By: Test results given in this report apply only to the specific sample(s) tested and are traceable to national or international standard through calibration of the equipment and evaluating measurement uncertainty herein. This report MUST not be used to claim product endorsement by TAF, NEMKO or any agency of the Government. This test report shall not be reproduced except in full, without the written approval of International Standards Laboratory. -2 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT 1. Test SET-UP (Block Diagram of Configuration) Measurement Equipment Used: EQUIPMENT TYPE MFR MODEL NUMBER SERIAL NUMBER LAST CAL. CAL DUE. Signal Analyzer (44GHz) R&S FSV3044 101463 02/06/2024 02/06/2025 Horn antenna (1GHz - 18GHz) EM EM-AH-10180 2011071401 11/27/2023 11/27/2024 MXG Vector Signal Generator KEYSIGHT N5182B MY53052399 12/26/2023 12/26/2024 EUT Coaxial Cable Horn Antenna 1.5m 3m Turntable S.G 0dBm Spectrum Analyzer 1.5m -3 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT 2. EUT Photo Figure 1 2.4G Antenna -4 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT Te s t Photo Figure 1 Figure 2 -5 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT Figure 3 -6 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT Test Result 2.4G Antenna Maximum gain test result: Maximum antenna Gain = -3.77 dBi Antenna Gain 2400 2450 2500 Unit -3.77 -4.04 -5.28 dBi Figure 1. 2.4G Antenna 2400MHz Figure 2. 2.4G Antenna 2450MHz Figure 3. 2.4G Antenna 2500MHz -7 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT Figure 1 Figure 2 -8 of 8- International Standards Laboratory Report Number: ISL-24LR0127ANT Figure 3

Test Report

TEST REPORT of FCC CFR Title 47 Part 15 Subpart C Product: VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM Brand: ALAN Main Model: KP362 Series Model: NA Model Difference: NA FCC ID: 2BK98KP362 FCC Rule Part: §15.247, Cat: DSS Reference: ANSI C63.10: 2013 KDB 558074 D01 v05r02 Applicant: ALAN SAFETY COMPANY LIMITED Address No.36, Alley 38, Lane 288, Heshun Rd. Sec.1 Guiren Dist., Tainan City, 71145, Taiwan(R.O.C.) Test Performed by: International Standards Laboratory Corp. LT Lab. TEL: +886-3-263-8888 FAX: +886-3-263-8899 No. 120, Lane 180, Hsin Ho Rd., Lung-Tan Dist., Tao Yuan City 325, Taiwan Report No.: ISL-24LR0127FCDSS Issue Date : September 18, 2024 FCC Registration Number: 487532 Test results given in this report apply only to the specific sample(s) tested and are traceable to national or international standard through calibration of the equipment and evaluating measurement uncertainty herein. According to customer agreement, the laboratory issues test reports based on the regulations or standards specifications, the measurement uncertainty is not considered in conformity decision rules. This test report shall not be reproduced except in full, without the written approval of International Standards Laboratory Corp. -2 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS VERIFICATION OF COMPLIANCE Applicant: ALAN SAFETY COMPANY LIMITED Equipment Under Test: VOICE TRACKING SOUNDS AMPLIFYING AND BT SYSTEM Brand: ALAN Main Model: KP362 Series Model: NA Model Difference: NA FCC ID: 2BK98KP362 Date of Test: August 29, 2024 ~ September 18, 2024 Date of EUT Received: August 29, 2024 APPLICABLE STANDARDS STANDARD TEST RESULT FCC Part 15.247 Complied We hereby certify that: All the tests in this report have been performed and recorded in accordance with the standards de-scribed above and performed by an independent electromagnetic compatibility consultant, International Standards Laboratory Corp. The test results contained in this report accurately represent the measurements of the characteristics and the energy generated by sample equipment under test at the time of the test. The sample equipment tested as described in this report is in compliance with the limits of above standards. Prepared By: Gigi Yeh / Senior Engineer Test By: Approved By: Kevin Yao / Senior Engineer Jerry Liu / Manager -3 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS Version Version No. Date Description 00 September 18, 2024 Initial creation of document -4 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS TABLE OF CONTENTS 1. General ........................................................................................................................................ 6 1.1 DESCRIPTION OF EUT ...................................................................................................................... 6 1.2 SPECIAL ACCESSORIES ..................................................................................................................... 7 1.3 EQUIPMENT MODIFICATIONS ........................................................................................................... 7 2. System Test Configuration ........................................................................................................ 8 2.1 EUT CONFIGURATION ...................................................................................................................... 8 2.2 EUT EXERCISE ................................................................................................................................. 8 2.3 TEST PROCEDURE ............................................................................................................................. 8 2.4 CONFIGURATION OF TESTED SYSTEM .............................................................................................. 8 3. Summary of Test Results ........................................................................................................... 9 4. Description of Test Modes ......................................................................................................... 9 5. AC Line Conduced Emission Test .......................................................................................... 10 5.1 STANDARD APPLICABLE .................................................................................................................10 5.2 MEASUREMENT PROCEDURE...........................................................................................................10 5.3 MEASUREMENT RESULT..................................................................................................................11 6. Peak Output Power Measurement ......................................................................................... 13 6.1 STANDARD APPLICABLE .................................................................................................................13 6.2 MEASUREMENT PROCEDURE...........................................................................................................13 6.3 MEASUREMENT RESULT..................................................................................................................14 7. Radiated Spurious Emission Test ........................................................................................... 15 7.1 STANDARD APPLICABLE .................................................................................................................15 7.2 MEASUREMENT PROCEDURE...........................................................................................................15 7.3 FIELD STRENGTH CALCULATION ....................................................................................................16 7.4 MEASUREMENT RESULT..................................................................................................................17 8. 100kHz Bandwidth of Band Edges Measurement ...…

Text truncated - open the document above for the full version.

Test Setup Photos

-113 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS 13.4 Appendix D: Photographs of Setup Conducted Emission Set up Photo -114 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS -115 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS Radiated Emission Set up Photos -116 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS -117 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS -118 of 119- International Standards Laboratory Corp. Report Number: ISL-24LR0127FCDSS

Contact Information

Applicant

Andy Chen
[email protected]+88662739975Fax: +88662739388

Technical Contact

International Standards Laboratory Corp.Jerry Liu
[email protected]886-3-263-8888

No. 120, Lane 180, Hsin Ho Rd., Lung Tan Dist., · Taiwan

Non-Technical Contact

International Standards Laboratory Corp.Jerry Liu
[email protected]886-3-263-8888

Test Firm

International Standards Laboratory Corp.Benson Chen
[email protected]886-3-263-8888Fax: 886-3-263-8899

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz6.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.