Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Kaiping Futuo Sanitary Ware Co., Ltd Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 9/23/2024 U.S. Agent Designation Kaiping Futuo Sanitary Ware Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BK9QFD-008): Name and company of U.S. agent: RGA Top Race US LLC Physical U.S. address of agent: 801 Barton Springs Road Austin TEXAS 78704 USA FRN of U.S. agent: 0033871963 Email address of U.S. agent: [email protected] RGA Top Race US LLC acknowledges their obligation to accept service of process on behalf of Kaiping Futuo Sanitary Ware Co., Ltd Kaiping Futuo Sanitary Ware Co., Ltd with the FRN 0035979863 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature XiaoFu Tan General Manager Kaiping Futuo Sanitary Ware Co., Ltd Signature Sindy Au manager RGA Top Race US LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V05
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BK9QFD-008 FD-008, FK-015, FK-035, FK-001, FK002, FK-007, FK-008, FK-004 We, Applicant Company Name: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province, China Phone: +86-18675074588 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-23 Signature Date: Printed Name of Signee / Title: Xiaofu Tan / General Manager Company: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province, China Phone: +86-18675074588 Fax: +86-750-2731938 Email: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BK9QFD-008 FD-008, FK-015, FK-035, FK-001, FK002, FK-007, FK-008, FK-004 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-23 Signature Date: Printed Name of Signee / Title: Xiaofu Tan / General Manager Company: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province, China Phone: +86-18675074588 Fax: +86-750-2731938 Email: [email protected]
Page 1 of 1 Rev.2.0 Kaiping Futuo Sanitary Ware Co., Ltd WIFI Channel 12 and 13 Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for FCC ID: 2BK9QFD-008 Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However, all the operated channels can’t be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo- location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Xiaofu Tan / General Manager Signature: Phone: +86-18675074588 Email: [email protected] Date: 2024-09-23
Kaiping Futuo Sanitary Ware Co., Ltd No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province, China Date: September 23, 2024 FCC ID: 2BK9QFD-008 Model Number: FD-008, FK-015, FK-035, FK-001, FK002, FK-007, FK-008, FK-004 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Kaiping Futuo Sanitary Ware Co., Ltd hereby declare that our product (ELECTRIC TOWEL WARMER) Model Number: FD-008, FK-015, FK-035, FK-001, FK002, FK-007, FK-008, FK-004 board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Xiaofu Tan / General Manager Company: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province, China Phone: +86-18675074588 Fax: +86-750-2731938 E-Mail: [email protected]
Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 4 External Photos Fig. 1 Fig. 2 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 4 Fig. 3 Fig. 4 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 4 Fig. 5 Fig. 6 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 4 Fig. 7
Page 1 of 1 FCC ID:2BK9QFD-008 LABEL AND LOCATION (Size: L2.0cm x 1.5cm) Label Location ELECTRIC TOWEL WARMER Model:FD-008 FCC ID:2BK9QFD-008
Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 5 Internal Photos Fig. 1 Fig. 2 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 5 Fig. 3 Fig. 4 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 5 Fig. 5 Fig.6 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 5 Fig.7 Fig.8 Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 5 Fig.9 Fig.10 BLE/2.4GWIFI ANT
Page 1 of 3 2BK9QFD-008 FCC RF Exposure Evaluation 1. Product Information Product Name: ELECTRIC TOWEL WARMER Trademark SAILAINUO Model No.: FD-008, FK-015, FK-035, FK-001, FK002, FK-007, FK-008, FK-004 Model Difference PCB board, structure and internal of these model(s) are the same, So no additional models were tested. BT Version: 4.2 Operation Frequency: 2402~2480MHz Channel numbers: 40 Channels Channel separation: 2M Modulation technology: GFSK Operation Frequency: 2412MHz~2462MHz Channel numbers: 11 Channels for 20MHz bandwidth 7 Channels for 20MHz bandwidth Channel separation: 5M Modulation technology: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK); IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK); IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Type: Internal Antenna Antenna gain: 0dBi Power supply: Input 100V~250V~, 50/60Hz 2. Evaluation Method and Limit Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is neous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numericallio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. Page 2 of 3 2BK9QFD-008 4. Conducted Power Results <BLE> Mode Test Channel Peak Output Power (dBm) LIMIT (dBm) GFSK CH00 -0.38 30.00 CH19 0.88 30.00 CH39 0.18 30.00 <2.4GWIFI> Mode Channel Frequency (MHz) Conducted Power (dBm) Limit (dBm) IEEE 802.11b 1 2412 15.29 30 6 2437 15.39 30 11 2462 15.93 30 IEEE 802.11g 1 2412 14.93 30 6 2437 14.80 30 11 2462 14.42 30 IEEE 802.11n HT20 1 2412 14.37 30 6 2437 13.00 30 11 2462 13.97 30 IEEE 802.11n HT40 3 2422 12.72 30 6 2437 13.14 30 9 2452 12.74 30 5. Manufacturing Tolerance GFSK Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 IEEE 802.11b Channel Channel 1 Channel 6 Channel 11 Target (dBm) 15.0 15.0 15.0 Tolerance ±(dB) 1.0 1.0 1.0 IEEE 802.11g Channel Channel 1 Channel 6 Channel 11 Target (dBm) 14.0 14.0 14.0 Tolerance ±(dB) 1.0 1.0 1.0 IEEE 802.11g Channel Channel 1 Channel 6 Channel 11 Target (dBm) 14.0 14.0 14.0 Tolerance ±(dB) 1.0 1.0 1.0 IEEE 802.11n HT20 Channel Channel 1 Channel 6 Channel 11 Target (dBm) 14.0 14.0 14.0 Tolerance ±(dB) 1.0 1.0 1.0 IEEE 802.11n HT4 Channel Channel 3 Channel 6 Channel 9 Target (dBm) 13.0 13.0 13.0 Tolerance ±(dB) 1.0 1.0 1.0 Page 3 of 3 2BK9QFD-008 6. Evaluation Results 6.1 Standalone Evaluation Modulation Type Output power Antenna Gain (dBi) Antenna Gain (linear) MPE (mW/cm 2 ) MPE Limits (mW/cm 2 ) dBm mW GFSK 1.00 1.2589 0 1.0000 0.0003 1.0000 IEEE 802.11b 16.00 39.8107 0 1.0000 0.0079 1.0000 IEEE 802.11g 15.00 31.6228 0 1.0000 0.0063 1.0000 IEEE 802.11n HT20 15.00 31.6228 0 1.0000 0.0063 1.0000 IEEE 802.11n HT40 14.00 25.1189 0 1.0000 0.0050 1.0000 Remark: 1. Output power including tune up tolerance; 2. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. 6.2 Simultaneous Transmission for MPE Exclusion The sample support one BLE/2.4GWIFI modular. No need consider simultaneous transmission. 7. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure MPE Threshold per KDB 447498 v06. .......................THE END OF REPORT.........................
Manufacture:TUYA Product Name:CB2SAntenna Antenna Type:PCB Test Date:2021.03.18 Tested by:Haigang Ruan Approved by: Antenna Specification Licco Content 1.GeneralDescription..................................................................................1 2.TestConfigurations..................................................................................2 2.1TestEnvironment............................................................................2 2.2TestEquipment................................................................................2 2.3TestPrinciple...................................................................................2 3.TestResults...............................................................................................3 3.1S11...................................................................................................3 3.2GainandEfficiency.........................................................................4 3.3RadiationPattern.............................................................................5 4.AntennaDimensions................................................................................6 5.EUTPhoto................................................................................................6 6.TestSetupPhoto.......................................................................................7 1 1.GeneralDescription ManufacturerHangzhouTuyaInformationTechnologyCo.,Ltd Address Room701,Building3,MoreCenter,No.87GuDunRoad, Hangzhou,Zhejiang,China TestLocation Room106,Building3,LetongSciencePark,No.500, QiuyiRoad,BinjiangDistrict,Hangzhou ProductNameCB2SAntenna Productmodel CB2S AntennaType PCBAntenna TestItems Gain;Efficiency;RadiationPattern TestFrequency 2400-2500MHz TestStandard ANSI/IEEEStd149-1979 2 2.TestConfigurations 2.1TestEnvironment Temperature(°C)25 Humidity(%RH)60 AtmosphericPressure(kPa)100.5 2.2TestEquipment TestSystemTEM24Multi-probeMicrowaveChamber TestInstrumentAgilentE5071B 2.3TestPrinciple 3 3.TestResults 3.1S11 Frequency(MHz)240024502500 ReturnLoss(dB)-8.73-11.76-11.21 VSWR2.161.711.77 4 3.2GainandEfficiency Frequency(MHz)Peak Gain (dBi)Efficiency(%) 2400-0.9824.43 2410-0.6725.64 2420-0.3726.24 2430-0.1227.04 24400.0027.48 2450-0.4525.25 2460-0.5523.88 2470-0.6922.65 2480-0.9321.78 2490-1.1120.04 2500-2.0716.18 5 3.3RadiationPattern Phi02D Phi902D Theta902D 6 4.AntennaDimensions 5.EUTPhoto 7 6.TestSetupPhoto
Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EB Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 61 FCC Part 15C Test Report FCC ID: 2BK9QFD-008 Applicant: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province,China Manufacturer: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province,China EUT: ELECTRIC TOWEL WARMER Trade Mark: SAILAINUO Model Number: FD-008, FK-015,FK-035,FK-001,FK002,FK-007,FK-008,FK-004 Date of Receipt: August. 26, 2024 Test Date: August. 26, 2024 – September. 10, 2024 Date of Report: September. 10, 2024 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10:2013 Test Result: Pass Report Number: DL-240708045EB Prepared (Test Engineer): Pxing Huang Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EB Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 61 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(c) Radiated Spurious Emission PASS 15.205 Band Edge Emission PASS 15.247(b)(1) Peak Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(d) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EB Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 61 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: ELECTRIC TOWEL WARMER Trademark SAILAINUO Model No.: FD-008, FK-015,FK-035,FK-001,FK002,FK-007,FK-008,FK-004 Model Difference PCB board, structure and internal of these model(s) are the same, So no additional models were tested. BT Version: 4.2 Operation Frequency: 2402~2480MHz Channel numbers: 40 Channels Channel separation: 2M Modulation technology: GFSK Operation Frequency: 2412MHz~2462MHz Channel numbers: 11 Channels for 20MHz bandwidth 7 Channels for 20MHz bandwidth Channel separation: 5M Modulation technology: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK);IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK);IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Type: Internal Antenna Antenna gain: 0dBi Power supply: Input 100V~250V~, 50/60Hz Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2. Channel Lis Channel List Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 2412 06 2437 11 2462 02 2417 07 2442 03 2422 08 2447 04 2427 09 2452 05 2432 10 2457 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EB Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 61 EUT EUT 2.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Mode 1 IEEE 802.11b Mode 2 IEEE 802.11g Mode 3 IEEE 802.11n20 Mode 4 IEEE 802.11n40 Mode 5 Link Mode For Conducted Emission Final Test Mode Description Mode 5 Link Mode For Radiated Emission Final Test Mode Description Mode 1 IEEE 802.11b Note: 1. The measurements are performed at the highest, middle, lowest available channels. 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Radiated Spurious Emission Test C1 AC Mains Conducted Spurious Emission Test C1 AC Mains Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EB Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 61 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Model/Type No. Series No. Note Item Shielded Type Ferrite Core Length Note Note: (1) For detachable type I/O cable should be specified the length in cm in『Length』column. 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING During testing, channel & power controlling software provided by the customer was used to control the operating channel as well as the output power level. The RF output power selection is for the setting of RF output power expected by the customer and is going to be fixed on the end product. Test software Version cmd Mode IEEE 802.11b IEEE 802.11g IEEE 802.11n20 IEEE 802.11n40 Power Setting of Softwave 15 15 15 15 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EB Test Report Tel: 400-68…
Text truncated - open the document above for the full version.
Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EA Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 37 FCC Part 15C Test Report FCC ID: 2BK9QFD-008 Applicant: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province,China Manufacturer: Kaiping Futuo Sanitary Ware Co., Ltd Address: No. L1-1, No.3 Industrial Park, Shuikou Town, Kaiping City, Guangdong Province,China EUT: ELECTRIC TOWEL WARMER Trade Mark: SAILAINUO Model Number: FD-008, FK-015,FK-035,FK-001,FK002,FK-007,FK-008,FK-004 Date of Receipt: August. 26, 2024 Test Date: August. 26, 2024 – September. 10, 2024 Date of Report: September. 10, 2024 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10:2013 Test Result: Pass Report Number: DL-240708045EA Prepared (Test Engineer): Pxing Huang Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EA Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 37 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(c) Radiated Spurious Emission PASS 15.205 Band Edge Emission PASS 15.247(b)(1) Peak Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(d) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EA Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 37 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: ELECTRIC TOWEL WARMER Trademark SAILAINUO Model No.: FD-008, FK-015,FK-035,FK-001,FK002,FK-007,FK-008,FK-004 Model Difference PCB board, structure and internal of these model(s) are the same, So no additional models were tested. BT Version: 4.2 Operation Frequency: 2402~2480MHz Channel numbers: 40 Channels Channel separation: 2M Modulation technology: GFSK Operation Frequency: 2412MHz~2462MHz Channel numbers: 11 Channels for 20MHz bandwidth 7 Channels for 20MHz bandwidth Channel separation: 5M Modulation technology: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK);IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK);IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Type: Internal Antenna Antenna gain: 0dBi Power supply: Input 100V~250V~, 50/60Hz Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2. Channel Lis Channel List Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 2402 11 2422 23 2444 02 2404 12 2424 24 2446 ~ ~ ~ ~ 9 2418 20 2440 39 2478 10 2420 21 2442 40 2480 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EA Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 37 EUT EUT 2.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Mode 1 CH01 Mode 2 CH20 Mode 3 CH40 Mode 4 Link Mode For Conducted Emission Final Test Mode Description Mode 4 Link Mode For Radiated Emission Final Test Mode Description Mode 1 CH01 Mode 2 CH20 Mode 3 CH40 Note: 1. The measurements are performed at the highest, middle, lowest available channels. 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Radiated Spurious Emission Test C1 AC Mains Conducted Spurious Emission Test C1 AC Mains Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EA Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 37 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Model/Type No. Series No. Note Item Shielded Type Ferrite Core Length Note Note: (1) For detachable type I/O cable should be specified the length in cm in『Length』column. 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING During testing, channel & power controlling software provided by the customer was used to control the operating channel as well as the output power level. The RF output power selection is for the setting of RF output power expected by the customer and is going to be fixed on the end product. Test software Version cmd Frequency 2402 MHz 2440MHz 2480 MHz Power Setting of Softwave 10 10 10 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-240708045EA Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: service@dl-…
Text truncated - open the document above for the full version.
Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 2 Test setup Photos Radiated Measurement Photos Shenzhen DL Testing Technology Co., Ltd. FCC ID: 2BK9QFD-008 Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 2 Conducted Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 39.20 mW |