FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mamibot Manufacturing (Shanghai) Co., Ltd./
  3. 2BKBK-W120DP

2BKBK-W120DPRobot Window Cleaner

Mamibot Manufacturing (Shanghai) Co., Ltd.
Robot Window Cleaner - FCC ID 2BKBK-W120DP - Mamibot Manufacturing (Shanghai) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 29, 2024
Application Purpose
Original Equipment
Date of Application
Aug 29, 2024
Equipment Note
Robot Window Cleaner
Frequency Range
2402.00000000 - 2480.00000000
Company
Mamibot Manufacturing (Shanghai) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER MANUAL Mamibot EN Ultra Robot Window Cleaner iGLASSBOT W120-DP V.20240513. Featured with Four Self-Water-Spray Nozzles Thanks for purchasing Mamibot Robot Window cleaner W120-DP featured with four self-water-spray hole type. We hope W120-DP will bring you a smarter and more convenient lifestyle. If you encounter any problem not mentioned herein, please contact [email protected]. For more details, please visit our official website: http://www.mamibot.com. Please read all instructions before using this product, and keep it properly for future reference. Mamibot Mamibot 2-3 Safety Instructions and Warning 4 Specification 5 What’s in the package 6-7 Product Description 8-10 Function Menu 11-12 Installation 12-13 To Use W120-DP 14-15 App Use 17 Disclaimer 17 Product Warranty 18 Troubleshooting Table of Contents 19 Correct Disposal & Conformity 1 Main Unit Remote Charging Cleaning cloth installtion Fill Up the Water Tank Safety Rope Fixing 16 Maintenance Mamibot 10 Indicator Introduction & Abnormity Please read all instructions carefully, and keep it at hand for setting up, using and maintaining W120-DP. Any operation that against the following instruction may damage the device or cause injury. Safety Instructions and Warning Notes for Main Unit and Components Use only the original adapter, plug and battery. Use of other types will result in malfunction and / or danger. Use the proper electric outlet and make sure no heavy objects are placed on the adapter or power cord. Allow adequate ventilation around the adapter when using it to operate the device. Do not cover the adapter with objects that will reduce cooling. Always switch W120-DP off before carrying out any cleaning or maintenance work. Do not use W120-DP in a high moisture environment. Never handle the adapter with wet hands. Connect the adapter to a proper power source. The voltage require- ments can be found on the adapter. Do not use broken adapter, power cord or plug. The plug must be removed from the outlet before cleaning or remaining the device. Do not unplug the plug by pulling the power cord. Do not attempt to service the adapter and battery. Replace the whole unit if it is damaged or exposed to high moisture. Contact Mamibot dealer for help and maintenance. The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not disassemble, short circuit, heat above 40 (104)or incinerate. Do not expose your W120-DP, adapter and battery to rain or excess humidity, and keep it away from liquids (such as beverages, faucets, and so on). Avoid exposing your W120-DP, adapter to direct sunlight or intense light source, and keep it away from heat source (such as radiators, space heater, stoves and so on). Do not place your W120-DP in the vicinity of strong magnetic fields. Do not use it on cracked glass or to clean other surface with uneven area as it may fall off due to insufficient suction power. Operating W120-DP at temperature: 0-40(32-104) W120-DP must be used in accordance with the instruction manual. W120-DP is not to be used by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge may only use this device if they are supervised or have been given instruction about how to use it safely and understand what risks are involved. Mamibot 2 Manufacturer can not take any responsibilities for any damages or injuries caused by improper use. Warning Check if the safety rope and extension cable are broken or not before use. Fasten the safety rope and tie it to indoor fixtures before using W120-DP. Set danger warning area downstairs for no-balcony window and door. Battery shall be charged (Green light is on on the robot) before use. Do not use it on rainy or moist days. Switch power on before you put device onto glass. Make sure W120-DP can stick and stand on glass surface while put onto glass. Make sure to put the cleaning pad on the bottom of W120-DP correctly to avoid water leakage. Do not spray or pour water onto W120-DP and adapter. Keep hair, loose clothing, fingers and all parts of body away from the openings and moving parts. Do not use in areas with existed flammable or combustible liquids, gas. Please fully charge (about 2 hrs) and turn off W120-DP and place it in a cool and dry place if you do not use it for a long time. Charge it every 3 months at least to avoid battery dead. Please turn the switch on when you are going to use W120-DP, so that you can check the status of indicator. Mamibot 3 Specification Product Model Size of Main Unit Net Weight Adapter Input Adapter Output Rated Wattage Battery Type Battery Capacity Robot Rated Voltage Charging Time The Min. workable Surface Water Tank Capacity Working Noise Spraying Drive Type W120-DP 229*229*69 mm About 1.45KG 100-240VAC ~ 50/60Hz 24.0V 3.00A 72W Rechargeable Li-ion Battery 500mAh 24V About 2 hours 60 x 40 cm About 60 ml 75dB Motor-Driven Water Spray ※ The datas come from the lab of Mamibot Manufacturing USA Inc. It may be slightly different from the users’ data, please subject to the actual products. For continous products improvment, we reserve the right to any technical and design change without prior notice. Mamibot Mamibot 4 What’s in the package W120-DP x 1pcCleaning cloth x 2 pcs Remote x 1pc AC Plug x 1pc (with power cord) Adapter x 1pc User Manual x 1pc Accessories of some models may be slightly different and they are subject to the actual received products. Measuring Cup x 1pc USER MANUAL with Safety Rope Spray nozzle x 4 pcs Mamibot 5 Mamibot Product Description Top + Side View Bottom + Side View Main Unit Edge detection sensor Rear indicators Cleaning plate Air Inlet Wheel belt Spray nozzle Water tank lid Upgarde interface Air pressure detection port Self-cleaning scraper Switch LED Indicator Power Cord and safety rope Hand Grip Air Outlet Voice Outlet IR remote receiver Mamibot 6 Mamibot Remote Control Cleaning the left area in N-Type Cleaning the right area in N-Type Cleanin…

Text truncated - open the document above for the full version.

Attestation Statements

MamibotManufacturing(Shanghai)Co.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2024-08-27 U.S.AgentDesignation MamibotManufacturing(Shanghai)Co.,Ltd.acknowledgestheirconsentforthefollowingcontactlocatedin theUnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought (FCCID:2BKBK-W120DP) NameandcompanyofU.S.agent:MamibotManufacturingUSAInc. PhysicalU.S.addressofagent:OrangeSt.#600,Wilmington,NewCastle,DE19899,UnitedStates FRNofU.S.agent:0027935279 EmailaddressofU.S.agent:[email protected] MamibotManufacturingUSAInc.acknowledgestheirobligationtoacceptserviceofprocessonbehalfof MamibotManufacturing(Shanghai)Co.,Ltd. MamibotManufacturing(Shanghai)Co.,Ltd.withtheFRN[0035814854]acceptsitsobligationtomaintainan agentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature {JianguoLi} {SupplyChainDirector} {MamibotManufacturing(Shanghai)Co.,Ltd.} Signature {WilliamWill} {Manager} {MamibotManufacturingUSAInc.} 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Mamibot Manufacturing (Shanghai) Co., Ltd. Address: North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Phone: +86-21-62147369 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-08-27 Signature Date Name / Title: Jianguo Li / Supply Chain Director Company: Mamibot Manufacturing (Shanghai) Co., Ltd. Address: North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Phone: +86-21-62147369 Fax: N/A E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BKBK-W120DP W120-DP, W120-DP PRO, W120-DPA, W120-DPB, W120-DPE, W120-DPF We, applicant Company Name: Mamibot Manufacturing (Shanghai) Co., Ltd. Address: North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Phone: +86-21-62147369 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-08-27 Signature Date Name / Title: Jianguo Li / Supply Chain Director Company: Mamibot Manufacturing (Shanghai) Co., Ltd. Address: North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Phone: +86-21-62147369 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BKBK-W120DP W120-DP, W120-DP PRO, W120-DPA, W120-DPB, W120-DPE, W120-DPF For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-08-27 Signature Date Name / Title: Jianguo Li / Supply Chain Director Company: Mamibot Manufacturing (Shanghai) Co., Ltd. Address: North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Phone: +86-21-62147369 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Mamibot Manufacturing (Shanghai) Co., Ltd. North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Date: August 27, 2024 FCC ID: 2BKBK-W120DP Model Number: W120-DP, W120-DP PRO, W120-DPA, W120-DPB, W120-DPE, W120-DPF To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Mamibot Manufacturing (Shanghai) Co., Ltd. hereby declare that the difference of our product (Robot Window Cleaner) Model Number: W120-DP, W120-DP PRO, W120-DPA, W120-DPB, W120-DPE, W120-DPF is power adapter and battery difference, Radio section including board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Jianguo Li / Supply Chain Director Company: Mamibot Manufacturing (Shanghai) Co., Ltd. Address: North 21st FL, No.1 Building, LN1040 Caoyang Rd, Shanghai 200633, China Phone: +86-21-62147369 Fax: N/A E-Mail: [email protected]

External Photos

Page1of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Page6of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 Page7of7FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13 Fig.14

ID Label/Location Info

Page1of1FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L8.0cmxW5.0cm) RobotWindowCleaner Model:W120-DP FCCID:2BKBK-W120DP LabelLocation

Internal Photos

Page1of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 BTAntenna Page6of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 Page7of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13 Fig.14 Page8of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.15 Fig.16 Page9of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.17 Fig.18 Page10of10FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.19 Fig.20

RF Exposure Info

Page1of4FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation EUT:RobotWindowCleaner TestModel:W120-DP AdditionalModelNo.:W120-DPPRO,W120-DPA,W120-DPB,W120-DPE,W120-DPF ModelDeclaration:themanufacturerofthepoweradapterandbatteryisdifferent,othersare inthesame. Ratings: ForACAdapter:Input:100-240V~,50/60Hz,2.0A Output:24V3A DC14.8VbyRechargeableLi-ionBattery,500mAh HardwareVersion: EGS-01-MAIN-VQ5 SoftwareVersion: EGS-01-R4Q3L2A-S010 Bluetooth FrequencyRange:2402MHz~2480MHz ChannelNumber:40channelsforBluetoothV5.0(DTS) ChannelSpacing:2MHzforBluetoothV5.0(DTS) ModulationType:GFSKforBluetoothV5.0(DTS) BluetoothVersion:V5.0 AntennaDescription:PCBAntenna,2.5dBi(Max.) Exposurecategory : Generalpopulation/uncontrolledenvironment EUTType : ProductionUnit DeviceType : MobileDevices ModelDeclaration: ItemNameManufacturerModel Ratings Adapter SHENZHENRUIYU TECHNOLOGYCO., LTD RY72C240300M2 Input100-240V~:50/60Hz. 2.0AMax Adapter SHENZHENKEYSUN TECHNOLOGY LIMITED KS75DU-2400300 Input:100-240V~:50/60Hz. 2.0A Batterypack DongguanMangrove NewEnergyCo.,Ltd HSL503040-500mAh14.8V,500mAh,7.4Wh Batterypack Guangdong guoeucalyptus TechnologyCo.,Ltd EK1450014.8V,500mAh,7.4Wh Batterypack BetterPowerBattery Co.,LTD PL4730434S14.8V,500mAh,7.4Wh Page2of4FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthe sumoftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoes notapplywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalent conditions.Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimum testseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmission operations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic, andElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page3of4FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatypeand antennanumber Operatefrequencyband Maximumantenna gain Notes InternalPCBAntenna2400-2500MHz2.5dBiBTAntenna 6.ConductedPower [BLE] ModeChannel Frequency (MHz) PeakConductedOutputPower (dBm) GFSK 024020.75 192440-0.27 392480-0.15 [BT2LE] ModeChannel Frequency (MHz) PeakConductedOutputPower (dBm) GFSK 02402-0.23 1924400.45 392480-0.61 Page4of4FCCID:2BKBK-W120DP ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 7.ManufacturingTolerance [BLE] GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 [BT2LE] GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 8.MeasurementResults 8.1StandaloneMPEEvaluation AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypa…

Text truncated - open the document above for the full version.

Test Report

BT3LAntennatestreport ProductName:BT3L AntennaType:PCBantenna Writer:YinhuaZhang Maximum Gain:2.5dBi Efficiency:62.86% BT3LAntennatestreport Version1.0.0Date:2020-05-12NO:0000000001 Antenna TestReport GlobalIntelligentPlatform Manufacturer: Hangzhou Tuya Information Technology Co., Ltd Address: Room 701,Building 3,More Center,No.87 GuDun Road,Hangzhou, Zhejiang,China BT3LAntennatestreport Content 1.GeneralDescription.................................................................................3 2.TechnicalInformation.............................................................................3 3.TestStandards..........................................................................................3 4.TestItem..................................................................................................4 5.TestPhoto................................................................................................4 AppendixAS11/VSWR..............................................................................5 AppendixBGainandEfficiency................................................................6 AppendixCRadiationPattern(1Dand3D)................................................7 AppendixDTestSetupPhoto.....................................................................9 AppendixEEUTPhoto..................................................... 9 ......................... BT3LAntennatestreport 1.GeneralDescription EUTNameBT3LAntenna WirelesstypeBluetooth AntennaTypePCBantenna DimensionsAppendixA 2.TechnicalInformation FrequencyRange2402MHz~2480MHz TestFrequency2400,2410......2500MHz 3.TestStandards IdentityDocumentTitle IEEE149-1979IEEEStandardTestProcedures forAntennas BT3LAntennatestreport 4.TestItem ReportSectionDescription AppendixBS11/VSWR AppendixCGainandEfficiency AppendixD RadiationPattern(1Dand3D) 5.TestPhoto ReportSectionDescription AppendixETestSetupPhoto BT3LAntennatestreport AppendixAAntennaDimension AppendixBS11/VSWR Frequency(MHz)240024502500 ReturnLoss-8.73-11.76-11.21 BT3LAntennatestreport VSWR2.161.711.77 AppendixCGainandEfficiency Frequency(MHz)Efficiency(%) Gain(dBi) 240052.29%1.62 241052.17%1.71 242053.14%1.93 243054.16%1.98 244057.62%2.00 245059.64%2.17 246061.55%2.45 247060.64%2.38 BT3LAntennatestreport 248062.86%2.50 249059.85%2.30 250060.41%2.49 AppendixDRadiationPattern(1Dand3D) BT3LAntennatestreport BT3LAntennatestreport AppendixETestSetupPhoto

Test Report

Page1of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBTLE(ConductedMeasurement) ProductName:RobotWindowCleaner TestModel:W120-DP EnvironmentalConditions Temperature: 23.8  C RelativeHumidity:52.3% ATMPressure:100.0kPa TestEngineer:JerryChu Supervisedby:NickPeng Page2of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.662>=0.5Pass NVNTBLE1M2440Ant10.656>=0.5Pass NVNTBLE1M2480Ant10.655>=0.5Pass NVNTBLE2M2402Ant11.129>=0.5Pass NVNTBLE2M2440Ant11.169>=0.5Pass NVNTBLE2M2480Ant11.179>=0.5Pass Page3of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 Page4of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 Page5of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 Page6of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumPeakConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit(dBm)Verdict NVNTBLE1M2402Ant10.7530Pass NVNTBLE1M2440Ant1-0.2730Pass NVNTBLE1M2480Ant1-0.1530Pass NVNTBLE2M2402Ant1-0.2330Pass NVNTBLE2M2440Ant10.4530Pass NVNTBLE2M2480Ant1-0.6130Pass Page7of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNTBLE1M2402MHzAnt1 PowerNVNTBLE1M2440MHzAnt1 Page8of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNTBLE1M2480MHzAnt1 PowerNVNTBLE2M2402MHzAnt1 Page9of34FCCID:2BKBK-W120DPReportNo.:LCSA08014231EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:webmas…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jianguo Li
[email protected]+86-21-62147369Fax: +86-21-62147369

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing.