Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Rev 1/26/2023 NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-10-30 FCC ID: 2BKEQ-X2 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. pplicant: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Contact Person: Andy Wei Tel.: 18588201618 Email: [email protected] Sincerely, Signature:
Attestation Statements Date: 2025-10-30 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID: 2BKEQ-X2) NINGBO LFLY HEALTH TECHNOLOGY CO., LTD., the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated agent for service of process, NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated agent for service of process. Applicant Information: Company name: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Contact Name: Andy Wei Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Telephone No: 18588201618 Email: [email protected] FRN: 0031072531 Signature: Andy Wei Agent Information: Company Name:HOPEK CORPORATION INC Address: 16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN: 0034562900 Contact Name:Peter Davis Telephone No: 561-235-6113 Email: [email protected] Signature: Peter Davis
Antenna Description 1. PCB Antenna ( layout on PCB) 2.Antenna Max. Gain: 0dBi 3.Antenna Material Type: Cu 4. Only Transmit signal Transmittal Frequency Band:433 MHz. Antenna Quantity : 1PC Antenna Length : about 42mm Antenna Width : about 32mm Manufacturer: NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China 32mm 42mm
NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 1, 2025 Subject; Request for Confidentiality FCC ID: 2BKEQ-X2 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Andy Wei Title: Manager
Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Date:2025-10-30 Product Model Number: LF-X2D, LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, X2 FCC ID:2BKEQ-X2 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By: Andy Wei Contact Listed on FCC Wesbite Title: Manager Email: [email protected] On behalf of: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD.
NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Declaration Letter of Model Difference Date: 2025-10-30 FCC ID: 2BKEQ-X2 Tested Model Number: LF-X2D Adding Model Number(s): LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, X2, X2 All Adding Model Number(s) is/are same electrically identical as Tested Model Number. Only model name and color are different for market purpose. Yours Sincerely, Applicant: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Contact Person: Andy Wei Tel.: 18588201618 Email: [email protected] Sincerely, Signature:
Page 1 of 4 Report No.: LGT25J090 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 4 Report No.: LGT25J090 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 4 Report No.: LGT25J090 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 4 Report No.: LGT25J090 Appendix - External Photographs of EUT Constructional Details Photo 7
Label Size: 14*29mm FCC ID: 2BKEQ-X2
Page 1 of 2 Report No.: LGT25J090 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 ANT Page 2 of 2 Report No.: LGT25J090 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 RF TEST REPORT Product Name: Treadmill Model Number: LF-X2D, LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, XM-A1, X2 FCC ID: 2BKEQ-X2 Issued For : NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25J090HA01 Received Date: Oct. 17, 2025 Date of Test: Oct. 17, 2025 ~ Oct. 30, 2025 Date of Issue: Oct. 30, 2025 Report No.: LGT25J090HA01 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Manufacturer: NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Product Name: Treadmill Trademark: N/A Model Number: LF-X2D, LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, XM-A1, X2 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1093 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25J090HA01 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1093 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 TEST RESULT 8 Report No.: LGT25J090HA01 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Oct. 30, 2025 Initial Issue Report No.: LGT25J090HA01 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Treadmill Test Model Number: LF-X2D Series Number: LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, XM-A1, X2 Model Difference: Only the models are different. Frequency band: 433.925 MHz Power Rating: Battery 2*AAA 1.5V Modulation Type: ASK Antenna Type: PCB Antenna Antenna Gain: 0dBi Hardware version: N/A Software version: N/A Connecting I/O Port(s): N/A 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: A2LA Certificate No.: 6727.01 FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT25J090HA01 Page 6 of 8 2. FCC 47CFR §2.1093 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in KDB 447498 D01 General RF Exposure Guidance v06 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. Report No.: LGT25J090HA01 Page 7 of 8 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Report No.: LGT25J090HA01 Page 8 of 8 2.3 TEST RESULT Worse case is as below: Note:The maximum Equivalent Isotropic Radiated Power : 78.31dBuV/m‐95.3=-16.99dBm (refer to C63.10, section 10.3.9) ASK433.925-16.99-160.02511890.10463 Mode Limit Maximum Peak Conducted Output Power (dBm) frequency (GHz) Tune up Power (dBm) Tune up Power (mW) Result Threshold at which no SAR required is 0.1046≤ 3.0 for 1-g SAR, Separation distance is 5mm. ※※※※※END OF THE REPORT※※※※※
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China RF TEST REPORT Product Name: Treadmill Model Number: LF-X2D, LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, XM-A1, X2 FCC ID: 2BKEQ-X2 Issued For : NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25J090RF01 Received Date: Oct. 17, 2025 Date of Test: Oct. 17, 2025 ~ Dec. 02, 2025 Date of Issue: Dec. 02, 2025 Report No.: LGT25J090RF01 Page 2 of 32 TEST REPORT CERTIFICATION Applicant: NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Manufacturer: NINGBO LFLY HEALTH TECHNOLOGY Co., Ltd. Address: No. 5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Product Name: Treadmill Trademark: N/A Model Number: LF-X2D, LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, XM-A1, X2 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.231, Subpart C ANSI C63.10-2020 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25J090RF01 Page 3 of 32 TABLE OF CONTENTS Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 12 3.1 CONDUCTED EMISSION MEASUREMENT 12 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 13 3.4 TEST RESULTS 13 4. RADIATED EMISSION MEASUREMENT 14 4.1 RADIATED EMISSION LIMITS 14 4.2 TEST PROCEDURE 16 4.3 DEVIATION FROM TEST STANDARD 16 4.4 TEST SETUP 17 4.5 EUT OPERATING CONDITIONS 18 4.6 TEST RESULTS 18 4.7 FIELD STRENGTH CALCULATION 19 5. BANDWIDTH TEST 23 5.1 LIMIT 23 5.2 TEST REQUIREMENTS 23 5.3 TEST PROCEDURE 23 5.4 TEST SETUP 23 5.5 EUT OPERATION CONDITIONS 23 5.6 TEST RESULTS 24 6. DUTY CYCLE 25 6.1 TEST PROCEDURE 25 6.2 TEST SETUP 25 6.3 EUT OPERATION CONDITIONS 25 6.4 TEST RESULTS 26 Report No.: LGT25J090RF01 Page 4 of 32 TABLE OF CONTENTS Page 7. AUTOMATICALLY DEACTIVATE 29 7.1 STANDARD REQUIREMENT 29 7.2 TEST PROCEDURE 29 8. ANTENNA REQUIREMENT 31 8.1 STANDARD REQUIREMENT 31 8.2 EUT ANTENNA 31 APPENDIX 1-PHOTOS OF TEST SETUP 32 Report No.: LGT25J090RF01 Page 5 of 32 Revision History Rev. Issue Date Revisions 00 Dec. 02, 2025 Initial Issue Report No.: LGT25J090RF01 Page 6 of 32 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part 15.231, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A -- 15.205(a)/15.209/ 15.231.(b) Radiated Spurious Emission PASS -- 15.231(a)(1)/ 15.231(b)(2) Transmission requirement PASS -- 15.231(C) 20 dB Bandwidth PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Report No.: LGT25J090RF01 Page 7 of 32 1.1 TEST FACTORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. Parameter Uncertainty RF Output Power, Conducted ±0.71dB Unwanted Emission, Conducted ±0.63dB Conducted emission ±2.80dB All Emissions, Radiated (0.009-30MHz) ±2.16dB All Emissions, Radiated (30MHz-1GHz) ±4.61dB All Emissions, Radiated (1GHz-18GHz) ±5.49dB Note: The measurement uncertainty is not included in the test result. Report No.: LGT25J090RF01 Page 8 of 32 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Treadmill Test Model Number: LF-X2D Series Number: LF-B01, LF-C01, X2H, X2LF, X2J, X2M, X2K, X2N, X2ZF, X2OF, X2L, X2C, X2B, X2A, XM-A1, X2 Model Difference: Only the models are different. Frequency band: 433.925 MHz Power Rating: Battery 2*AAA 1.5V Modulation Type: ASK Antenna Type: PCB Antenna Antenna Gain: 0dBi Hardware version: N/A Software version: N/A Connecting I/O Port(s): N/A Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications orthe User Manual. 2. The antenna information refers to the manufacturer provide report, applicable only to the tested sample identified in the report. Due to the incorrect antenna information, a series of problems such as the accuracy of the test results will be borne by the customer. Report No.: LGT25J090RF01 Page 9 of 32 2.2 DESCRIPTION OF THE TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest M…
Text truncated - open the document above for the full version.
Page 1 of 1 Report No.: LGT25J090 Appendix - Test Setup photos Set-up for Radiated Spurious Emission, Below 1GHz Set-up for Radiated Spurious Emission, Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.925 MHz - 433.925 MHz | - |