FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xthings Industry llc/
  3. 2BKHH-IQ

2BKHH-IQUlticam IQ V2

Xthings Industry llc
Ulticam IQ V2 - FCC ID 2BKHH-IQ - Xthings Industry llc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 27, 2026
Application Purpose
Original Equipment
Equipment Note
Ulticam IQ V2
Frequency Range
2402.00000000 - 2480.00000000
Company
Xthings Industry llc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Local Representative Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(7), of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC IDModel name 2BKHH-IQULTICAM-IQ06 We hereby acknowledge as follows: i.both signees confirm that the point of contact accepts responsibility to act as a US- American Representative on behalf of the applicant ii.the point of contact provides the physical U.S. address and email as listed below iii.both parties maintain the requirements of this agreement for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. iv.An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. US-American Point of ContactApplicant/Approval Holder Signature Date: 2026-3-24 Signature Date: 2026-3-24 Company Name:Xthings Industry llcXthings Industry llc FRN:00358477630035847763 Contact Name:Jiachong XuJiachong Xu Address:47703 Fremont Blvd, Fremont, CA 94538 47703 Fremont Blvd, Fremont, CA 94538 Phone:765-464-4109765-464-4109 Email:[email protected]@u-tec.com

External Photos

Page 1 of 2 FCC ID: 2BKHH-IQ External Photos Page 2 of 2 FCC ID: 2BKHH-IQ

ID Label/Location Info

Label FCC ID: 2BKHH-IQ

Internal Photos

Page 1 of 5 FCC ID: 2BKHH-IQ Internal photos Page 2 of 5 FCC ID: 2BKHH-IQ Page 3 of 5 FCC ID: 2BKHH-IQ Page 4 of 5 FCC ID: 2BKHH-IQ FPC ANT Page 5 of 5 FCC ID: 2BKHH-IQ

RF Exposure Info

Page 1 of 8 Report No.: AiTSZ-260209003FW3 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. If there is a need to alter or revise this document, the right belongs to Guangdong Asia Hongke Test Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. RF Exposure evaluation Product Name : Ulticam IQ V2 Brand Name : N/A Model : ULTICAM-IQ06 Series Model : N/A FCC ID : 2BKHH-IQ Applicant : Xthings Industry llc Address : 47703 Fremont Blvd, Fremont, CA 94538 Manufacturer : Xthings Industry llc Address : 47703 Fremont Blvd, Fremont, CA 94538 Standard(s) : 47CFR §1.1310, 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Date of Receipt : Feb. 09, 2026 Date of Test : Feb. 09, 2026~ Mar. 17, 2025 Issued Date : Mar. 24, 2025 Issued By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Reviewed by: Approved by: Aalen.Ye Allen Wang Page 2 of 8 Report No.: AiTSZ-260209003FW3 Report Revise Record Report Version Issued Date Notes M0 Mar. 24, 2025 Initial Release Page 3 of 8 Report No.: AiTSZ-260209003FW3 Contents 1 GENERAL INFORMATION .......................................................................................................................................... 4 1.1 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 4 1.2 GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 4 1.3 TEST FACILITY .............................................................................................................................................................. 5 1.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 2 METHOD OF MEASUREMENT ................................................................................................................................... 6 2.1 APPLICABLE STANDARD.................................................................................................................................................. 6 2.2 LIMIT ......................................................................................................................................................................... 6 2.3 MPE CALCULATION METHOD ......................................................................................................................................... 7 2.4 MANUFACTURING TOLERANCE ........................................................................................................................................ 7 2.5 STANDALONE MPE RESULT ............................................................................................................................................ 8 2.6 CONCLUSION ............................................................................................................................................................... 8 Page 4 of 8 Report No.: AiTSZ-260209003FW3 1 GENERAL INFORMATION 1.1 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Normal Temperature: 25°C Relative Humidity: 55 % Air Pressure: 101 kPa 1.2 General Description of EUT Product Name: Ulticam IQ V2 Model/Type reference: ULTICAM-IQ06 Serial Model: N/A Power Supply: DC 12V/2A from external circuit Hardware Version: N/A Software Version: N/A Sample(s) Status: AiTSZ-260209003-1(Normal sample) AiTSZ-260209003-2(Engineer sample) Bluetooth : Supported type: Bluetooth BR/EDR Modulation: GFSK, π/4DQPSK, 8DPSK Operation frequency: 2402MHz~2480MHz Channel number: 79 Channel separation: 1MHz Antenna type: FPC antenna Antenna gain: 3.10dBi 2.4G WIFI: Supported type: 802.11b/802.11g /802.11n(HT20)/802.11n(HT40) Modulation: 802.11b(DSSS): CCK, DQPSK, DBPSK 802.11g(OFDM): BPSK, QPSK, 16-QAM, 64-QAM 802.11n(OFDM): BPSK, QPSK, 16-QAM, 64-QAM Operation frequency: 802.11b/802.11g/802.11n(H20): 2412MHz~2462MHz 802.11n(H40): 2422MHz~2452MHz Channel number: 802.11b/802.11g/802.11n(H20): 11 802.11n(H40): 7 Channel separation: 5MHz Antenna type: FPC antenna Antenna gain: 3.10dBi Remark: The above DUT's information was declared by manufacturer. For more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Page 5 of 8 Report No.: AiTSZ-260209003FW3 1.3 Test Facility Test Laboratory: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China The test facility is recognized, certified or accredited by the following organizations: FCC-Registration No.: 251906 Designation Number: CN1376 Guangdong Asia Hongke Test Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC —Registration No.: 31737 CAB identifier: CN0165 The 3m Semi-anechoic chamber of Guangdong Asia Hongke Test Technology Limited has been registered b…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 33 Report No.: AiTSZ-260209003FW1 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. If there is a need to alter or revise this document, the right belongs to Guangdong Asia Hongke Test Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. TEST REPORT Product Name : Ulticam IQ V2 Brand Name : N/A Model : ULTICAM-IQ06 Series Model : N/A FCC ID : 2BKHH-IQ Applicant : Xthings Industry llc Address : 47703 Fremont Blvd, Fremont, CA 94538 Manufacturer : Xthings Industry llc Address : 47703 Fremont Blvd, Fremont, CA 94538 Standard(s) : FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of Receipt : Feb. 09, 2026 Date of Test : Feb. 09, 2026~ Mar. 17, 2025 Issued Date : Mar. 24, 2025 Issued By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Reviewed by: Approved by: Aalen.Ye Allen Wang Page 2 of 33 Report No.: AiTSZ-260209003FW1 Report Revise Record Report Version Issued Date Notes M0 Mar. 24, 2025 Initial Release Page 3 of 33 Report No.: AiTSZ-260209003FW1 Contents 1 TEST SUMMARY ....................................................................................................................................................... 4 1.1 TEST STANDARDS ......................................................................................................................................................... 4 1.2 TEST SUMMARY ........................................................................................................................................................... 4 1.3 TEST FACILITY .............................................................................................................................................................. 5 1.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 2 GENERAL INFORMATION .......................................................................................................................................... 6 2.1 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 6 2.2 GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 6 2.3 DESCRIPTION OF TEST MODES AND TEST FREQUENCY .......................................................................................................... 7 2.4 SPECIAL ACCESSORIES ................................................................................................................................................... 8 2.5 EQUIPMENT LIST FOR THE TEST ....................................................................................................................................... 8 3 TEST CONDITIONS AND RESULTS ............................................................................................................................ 10 3.1 CONDUCTED EMISSIONS TEST ....................................................................................................................................... 10 3.2 RADIATED EMISSIONS AND BAND EDGE .......................................................................................................................... 13 3.3 MAXIMUM PEAK CONDUCTED OUTPUT POWER ............................................................................................................... 20 3.4 POWER SPECTRAL DENSITY .......................................................................................................................................... 21 3.5 6DB BANDWIDTH ....................................................................................................................................................... 22 3.6 OUT-OF-BAND EMISSIONS ........................................................................................................................................... 23 3.7 ANTENNA REQUIREMENT ............................................................................................................................................. 25 4 TEST SETUP PHOTOGRAPHS OF EUT ....................................................................................................................... 26 5 PHOTOS OF EUT ..................................................................................................................................................... 27 Page 4 of 33 Report No.: AiTSZ-260209003FW1 1 TEST SUMMARY 1.1 Test Standards The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz ANSI C63.10: 2020: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 15.247 Meas Guidance v05r02: Guidance for Compliance Measurements on Digital Transmission System, Frequency Hopping Spreda Spectrum System, and Hybrid System Devices Operating Under Section 15.247 of the FCC Rules 1.2 Test Summary Test Item Section in 47 CFR Result Antenna re…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 27 Report No.: AiTSZ-260209003FW2 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. If there is a need to alter or revise this document, the right belongs to Guangdong Asia Hongke Test Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. TEST REPORT Product Name : Ulticam IQ V2 Brand Name : N/A Model : ULTICAM-IQ06 Series Model : N/A FCC ID : 2BKHH-IQ Applicant : Xthings Industry llc Address : 47703 Fremont Blvd, Fremont, CA 94538 Manufacturer : Xthings Industry llc Address : 47703 Fremont Blvd, Fremont, CA 94538 Standard(s) : FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of Receipt : Feb. 09, 2026 Date of Test : Feb. 09, 2026~ Mar. 17, 2025 Issued Date : Mar. 24, 2025 Issued By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Reviewed by: Approved by: Aalen.Ye Allen Wang Page 2 of 27 Report No.: AiTSZ-260209003FW2 Report Revise Record Report Version Issued Date Notes M0 Mar. 24, 2025 Initial Release Page 3 of 27 Report No.: AiTSZ-260209003FW2 Contents 1 TEST SUMMARY ....................................................................................................................................................... 4 1.1 TEST STANDARDS ......................................................................................................................................................... 4 1.2 TEST SUMMARY ........................................................................................................................................................... 4 1.3 TEST FACILITY .............................................................................................................................................................. 5 1.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 2 GENERAL INFORMATION .......................................................................................................................................... 6 2.1 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 6 2.2 GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 6 2.3 DESCRIPTION OF TEST MODES AND TEST FREQUENCY .......................................................................................................... 7 2.4 SPECIAL ACCESSORIES ................................................................................................................................................... 8 2.5 EQUIPMENT LIST FOR THE TEST ....................................................................................................................................... 8 3 TEST CONDITIONS AND RESULTS ............................................................................................................................ 10 3.1 CONDUCTED EMISSIONS TEST ....................................................................................................................................... 10 3.2 RADIATED EMISSIONS AND BAND EDGE .......................................................................................................................... 13 3.3 MAXIMUM PEAK CONDUCTED OUTPUT POWER ............................................................................................................... 20 3.4 POWER SPECTRAL DENSITY .......................................................................................................................................... 21 3.5 6DB BANDWIDTH ....................................................................................................................................................... 22 3.6 OUT-OF-BAND EMISSIONS ........................................................................................................................................... 23 3.7 ANTENNA REQUIREMENT ............................................................................................................................................. 25 4 TEST SETUP PHOTOGRAPHS OF EUT ....................................................................................................................... 26 5 PHOTOS OF EUT ..................................................................................................................................................... 27 Page 4 of 27 Report No.: AiTSZ-260209003FW2 1 TEST SUMMARY 1.1 Test Standards The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz ANSI C63.10: 2020: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 15.247 Meas Guidance v05r02: Guidance for Compliance Measurements on Digital Transmission System, Frequency Hopping Spreda Spectrum System, and Hybrid System Devices Operating Under Section 15.247 of the FCC Rules 1.2 Test Summary Test Item Section in 47 CFR Result Antenna re…

Text truncated - open the document above for the full version.

Test Report

www. vlg .co m.cn VLG has possessionof proprietaryinformationprovidedin this report and this proprietaryinformation shall be kept in strict confidenceand not disclosedto any personor firm withoutthe prior writtenconsent of VLG CommunicationTechnology. Page 1 VLG TECHNOLOGY ShenZhenVLG WirelessTECHNOLOGYCO,.LTD 深圳市维力谷无线技术股份有限公司 承认书 客户 / 项目名安威士/UI2504-09频段 WIFI VLG料号V1931-027-A-01版本R:A 射频何军森 确认 品质余洪 确认 结构何发荣PM虞伟 日期2026-3-10 客户项目名称 料号 客户项目名称:UI2504-09 客户项目料号: 客户确认 VLG CommunicationTechnology 研发项目客户满意度调查(客户请针对我们的研发或PM管理人员工作进行一个评述,督促我们更好服 务于你) RF技术人员□满意□基本满意□不满意 结构技术人员□满意□基本满意□不满意 项目管理(PM管理人员)□满意□基本满意□不满意 建议项说明: 天线图片: VLG深圳市维力谷无线技术股份有限公司 www.vlg.com.cn VLGCommunicationhaspossessionofproprietaryinformationprovidedinthisreportandthisproprietary informationshallbekeptinstrictconfidenceandnotdisclosedtoanypersonorfirmwithouttheprior writtenconsentofVLGCommunicationTechnology. . Page2 索引 1、规格......................................................................................3 2、电气性能.................................................................................3 2.1规格标准........................................................................3 2.2天线的匹配电路................................................................3 2.3天线VSWR....................................................................4 2.4无源测试数据...................................................................4 2.5天线方向图......................................................................5 2.6有源测试数据...................................................................6 3、产品2D图..................................................................................6 4、样品尺寸检测报告..........................................................................7 VLG深圳市维力谷无线技术股份有限公司 www. vlg.com.cn VLG Communicationhas possessionof proprietaryinformationprovidedin this report and this proprietary informationshall be kept in strict confidenceand not disclosedto any personor firm withoutthe prior writtenconsentof VLG CommunicationTechnology. . Page 3 1、规格:报告主要提供UI2504-09WIFI天线的各项电性能参数的测试状况。WIFI天线为 2400~2500MHz 频段. 2、电 气性能 2.1 规格标准 WIFI天线工作频段在2400 ~2500 MHz 频段,下表是天线的无源性能测试指标。 2.2 天线匹配电路: 未添加调谐匹配 2. 3天线VSWR 2.3.1测试的设置 VSWR测试装置依次的连接为:8714ET网络分析仪→50欧姆的同轴Cable→→测试治具。 测试治具的处理:天线 50 欧姆测试点处用一根电缆引出 SMA 接头,与套有扼流圈的铜管连接,再 依次连接其他装置。 VLG深圳市维力谷无线技术股份有限公司 www.vlg.com.cn VLGCommunicationhaspossessionofproprietaryinformationprovidedinthisreportandthisproprietary informationshallbekeptinstrictconfidenceandnotdisclosedtoanypersonorfirmwithouttheprior writtenconsentofVLGCommunicationTechnology. . Page4 2.3.2天线VSWR: 2.4无源测试数据: VLG深圳市维力谷无线技术股份有限公司 www.vlg.com.cn VLGCommunicationhaspossessionofproprietaryinformationprovidedinthisreportandthisproprietary informationshallbekeptinstrictconfidenceandnotdisclosedtoanypersonorfirmwithouttheprior writtenconsentofVLGCommunicationTechnology. . Page5 2.5天线方向图 VLG深圳市维力谷无线技术股份有限公司 www.vlg.com.cn VLGCommunicationhaspossessionofproprietaryinformationprovidedinthisreportandthisproprietary informationshallbekeptinstrictconfidenceandnotdisclosedtoanypersonorfirmwithouttheprior writtenconsentofVLGCommunicationTechnology. . Page6 2.6有源测试数据 3.产品2D图: VLG深圳市维力谷无线技术股份有限公司 www.vlg.com.cn VLGCommunicationhaspossessionofproprietaryinformationprovidedinthisreportandthisproprietary informationshallbekeptinstrictconfidenceandnotdisclosedtoanypersonorfirmwithouttheprior writtenconsentofVLGCommunicationTechnology. . Page7 深圳市维力谷无线技术股份有限公司 ShenZhenVLGWirelessTechnologyCo,.Ltd 样品尺寸检测报告(FAI) 客户名称 安威士 产品名称 UI2504-09 产品类型WIFI天线 供应商名称/产品料号 V1931-027-A-01 检验人员余洪 图纸版本A单位mm检验日期 2026.03. 09 序 号 检测项 目 检测标准 实际测量尺寸 判 定 结 果 检测 仪器 穴 号 备 注 12345 1外观 见外观不良现象简 述 OKOKOKOKOKOK 目 测 图 纸 尺 寸 70±2 70.5170.3070.5670.6470.55 OKDC 45.6±0.2 45.5545.6245.5845.6145.59 OKDC 4.2±0.2 4.194.214.234.184.22 OKDC 以下空白 最终判定:OK■NG□ 检测仪器简称:PG—塞(圆孔)规、RG—R规、SG—块规、LG—环规DC —数显卡尺PM—二次元坐标投影仪 版本:A.0 表单编号:VLG/QRF8.2-28/A.0 检验:蒋涛审核:核准:余洪

Test Report

Page 1 of 29 Report No.: AiTSZ-260209003FW1 Appendix RF test data for BLE Page 2 of 29 Report No.: AiTSZ-260209003FW1 1. Duty Cycle 1.1 Test Result 1.1.1 Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 1M SISO 2402 0.401 0.625 64.16 1.93 0.03 2440 0.401 0.625 64.16 1.93 0.00 2480 0.401 0.625 64.16 1.93 0.04 2M SISO 2402 0.216 0.625 34.56 4.61 0.03 2440 0.216 0.625 34.56 4.61 0.03 2480 0.216 0.625 34.56 4.61 0.03 Page 3 of 29 Report No.: AiTSZ-260209003FW1 1.2 Test Graph 1.2.1 Ant1 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Page 4 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 5 of 29 Report No.: AiTSZ-260209003FW1 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV Page 6 of 29 Report No.: AiTSZ-260209003FW1 2. Bandwidth 2.1 Test Result 2.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 1.036 / Pass 2440 1 1.029 / Pass 2480 1 1.024 / Pass 2M SISO 2402 1 2.048 / Pass 2440 1 2.051 / Pass 2480 1 2.029 / Pass 2.1.2 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.658 >=0.5 Pass 2440 1 0.664 >=0.5 Pass 2480 1 0.659 >=0.5 Pass 2M SISO 2402 1 1.131 >=0.5 Pass 2440 1 1.119 >=0.5 Pass 2480 1 1.118 >=0.5 Pass Page 7 of 29 Report No.: AiTSZ-260209003FW1 2.2 Test Graph 2.2.1 OBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Page 8 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 9 of 29 Report No.: AiTSZ-260209003FW1 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV Page 10 of 29 Report No.: AiTSZ-260209003FW1 2.2.2 6dB BW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Page 11 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 12 of 29 Report No.: AiTSZ-260209003FW1 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV Page 13 of 29 Report No.: AiTSZ-260209003FW1 3. Maximum Conducted Output Power 3.1 Test Result 3.1.1 Power Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 1M SISO 2402 -0.95 <=30 Pass 2440 0.10 <=30 Pass 2480 0.62 <=30 Pass 2M SISO 2402 -0.80 <=30 Pass 2440 0.25 <=30 Pass 2480 0.75 <=30 Pass Note1: Antenna Gain: Ant1: 3.10dBi; Page 14 of 29 Report No.: AiTSZ-260209003FW1 3.2 Test Graph 3.2.1 Power 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Page 15 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 16 of 29 Report No.: AiTSZ-260209003FW1 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV Page 17 of 29 Report No.: AiTSZ-260209003FW1 4. Maximum Power Spectral Density 4.1 Test Result 4.1.1 PSD Mode TX Type Frequency (MHz) Maximum PSD (dBm) Verdict ANT1 Limit 1M SISO 2402 -1.04 <=8 Pass 2440 0.00 <=8 Pass 2480 0.54 <=8 Pass 2M SISO 2402 -0.92 <=8 Pass 2440 0.09 <=8 Pass 2480 0.67 <=8 Pass Note1: Antenna Gain: Ant1: 3.10dBi; Page 18 of 29 Report No.: AiTSZ-260209003FW1 4.2 Test Graph 4.2.1 PSD 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Page 19 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 20 of 29 Report No.: AiTSZ-260209003FW1 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV Page 21 of 29 Report No.: AiTSZ-260209003FW1 5. Unwanted Emissions In Non-restricted Frequency Bands 5.1 Test Result 5.1.1 Ref Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) 1M SISO 2402 1 -1.03 2440 1 0.01 2480 1 0.53 2M SISO 2402 1 -0.90 2440 1 0.12 2480 1 0.68 5.1.2 CSE Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) Limit (dBm) Verdict 1M SISO 2402 1 -1.03 -21.03 Pass 2440 1 0.01 -19.99 Pass 2480 1 0.53 -19.47 Pass 2M SISO 2402 1 -0.90 -20.90 Pass 2440 1 0.12 -19.88 Pass 2480 1 0.68 -19.32 Pass Page 22 of 29 Report No.: AiTSZ-260209003FW1 5.2 Test Graph 5.2.1 Ref 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Page 23 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 24 of 29 Report No.: AiTSZ-260209003FW1 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV Page 25 of 29 Report No.: AiTSZ-260209003FW1 5.2.2 CSE 1M_LCH_2402MHz_Ant1_NTNV 1M_LCH_2402MHz_Ant1_NTNV Page 26 of 29 Report No.: AiTSZ-260209003FW1 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Page 27 of 29 Report No.: AiTSZ-260209003FW1 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV Page 28 of 29 Report No.: AiTSZ-260209003FW1 2M_LCH_2402MHz_Ant1_NTNV 2M_MCH_2440MHz_Ant1_NTNV Page 29 of 29 Report No.: AiTSZ-260209003FW1 2M_HCH_2480MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV ********************** End of Report **********************

Test Report

Page 1 of 46 Report No.: AiTSZ-260209003FW2 Appendix RF test data for WIFI2.4G Page 2 of 46 Report No.: AiTSZ-260209003FW2 1. Duty Cycle 1.1 Test Result 1.1.1 Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 802.11b SISO 2412 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2462 100.000 100.000 100.00 0.00 0.00 802.11g SISO 2412 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2462 100.000 100.000 100.00 0.00 0.00 802.11n (HT20) SISO 2412 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2462 100.000 100.000 100.00 0.00 0.00 802.11n (HT40) SISO 2422 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2452 100.000 100.000 100.00 0.00 0.00 Page 3 of 46 Report No.: AiTSZ-260209003FW2 1.2 Test Graph 1.2.1 Ant1 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Page 4 of 46 Report No.: AiTSZ-260209003FW2 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Page 5 of 46 Report No.: AiTSZ-260209003FW2 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Page 6 of 46 Report No.: AiTSZ-260209003FW2 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Page 7 of 46 Report No.: AiTSZ-260209003FW2 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_LCH_2422MHz_Ant1 (SISO)_NTNV Page 8 of 46 Report No.: AiTSZ-260209003FW2 802.11n(HT40)_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_HCH_2452MHz_Ant1 (SISO)_NTNV Page 9 of 46 Report No.: AiTSZ-260209003FW2 2. Bandwidth 2.1 Test Result 2.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 802.11b SISO …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jiachong Xu
[email protected]Fax: N/A

Technical Contact

Xthings Industry llcJiachong Xu
[email protected]

47703 Fremont Blvd,Fremont, · United States

Test Firm

Guangdong Asia Hongke Test Technology LimitedCoin Tang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
215C2.41 GHz - 2.46 GHz22.60 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Xthings Industry llc

Ultraloq smart lock - FCC ID 2BKHH-MISSION - Xthings Industry llc
2BKHH-MISSION

Ultraloq smart lock

Mar 24, 2026

Equipment Class

DTS - Digital Transmission System
Latch 5 Pro Smart Matter Deadbolt - FCC ID 2BKHH-LATCH5PRO - Xthings Industry llc
2BKHH-LATCH5PRO

Latch 5 Pro Smart Matter Deadbolt

Feb 05, 2026

Equipment Class

DTS - Digital Transmission System
Z-Wave Module - FCC ID 2BKHH-Z-WAVE - Xthings Industry llc
2BKHH-Z-WAVE

Z-Wave Module

Dec 18, 2025

Equipment Class

DTS - Digital Transmission System
SECU365 Time Clock - FCC ID 2BKHH-CP1 - Xthings Industry llc
2BKHH-CP1

SECU365 Time Clock

Aug 26, 2024

Equipment Class

DTS - Digital Transmission System