FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhejiang Shuyue Health Technology Co.,ltd./
  3. 2BKHU-SY-201A

2BKHU-SY-201AMassage Chair

Zhejiang Shuyue Health Technology Co.,ltd.
Massage Chair - FCC ID 2BKHU-SY-201A - Zhejiang Shuyue Health Technology Co.,ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 09, 2024
Application Purpose
Original Equipment
Date of Application
Sep 09, 2024
Equipment Note
Massage Chair
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhejiang Shuyue Health Technology Co.,ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Zhejiang Shuyue Health Technology Co.,ltd. No.17th Xingyang Road, Furniture Garden, Wanquan Industry Base, Pingyang County Wenzhou China Date: 2024.9.02 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FRN: 0035848316 FCC ID: 2BKHU-SY-201A US Agent – Attestation Statement / Part 2.911(d)(7) Zhejiang Sh uyue Health Technology Co.,ltd. certifies, that as of September 02, 2024, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: 2BKHU- SY-201A Zhejiang Shuyue Health Technology Co.,ltd. accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of Zhejiang Shuyue Health Technology Co.,ltd. for FCC ID: 2BKHU-SY-201A Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: Zhejiang Shuyue Health Technology Co.,ltd. Designated Agent: FCC US Agent, LLC Company Representative: Yaoyao Lin Designated Agent Representative: Tim Payne Signature: Signature:

Attestation Statements

Rev 1/26/2023 (Zhejiang Shuyue Health Technology Co.,ltd.) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09‐02‐2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BKHU‐SY‐201A Zhejiang Shuyue Health Technology Co.,ltd. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Yaoyao Lin / Sales Manager Zhejiang Shuyue Health Technology Co.,ltd. Rev 1/26/2023 (Zhejiang Shuyue Health Technology Co.,ltd.) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09‐02‐2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BKHU‐SY‐201A Zhejiang Shuyue Health Technology Co.,ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Yaoyao Lin / Sales Manager Zhejiang Shuyue Health Technology Co.,ltd.

Cover Letter(s)

( Zhejiang Shuyue Health Technology Co.,ltd.) Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2BKHU-SY-201A Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram, Schematics, Operational Description Block Diagram .pdf, Schematics .pdf , Operation Description .pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Short-term confidentiality requested: 180 days Exhibit Type File Name Test Setup Photos, User Manual Test Setup Photos .pdf, User Manual.pdf Sincerely, Yaoyao Lin / Sales Manager Zhejiang Shuyue Health Technology Co.,ltd.

External Photos

External photos: ---The End---

ID Label/Location Info

Label and Label Location

Internal Photos

Internal photos: Antenna ---The End---

RF Exposure Info

FCC ID: 2BKHU-SY-201A RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A) Limits for Occupational/Control Exposures 300-1500 -- -- F/300 6 1500-100000 -- -- 5 6 (B) Limits for General Population/Uncontrol Exposures 300-1500 -- -- F/1500 6 1500-100000 -- -- 1 30 11.1 Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm 2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1416 R= distance between observation point and center of the radiator in cm Pd the limit of MPE,1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. mW = 10^( dBm/10) 11.2 Measurement Result Operation Frequency: 2402MHz-2480MHz; Antenna gain: 1.7 dBi; R=20cm Chann el Freq. (MHz) modulati on Measure d power (dBm) Tune-up power (dBm) Max tune-up power (dBm) Antenna Gain Numeric Evaluation result (mW/cm2) Power density Limits (mW/cm2 ) 2402 GFSK 1.01 1±1 2 1.48 0.000466368 1 2441 0.74 0±1 1 1.48 0.000370450 1 2480 0.54 0±1 1 1.48 0.000370450 1 2402 pi/4- DQPSK 1.76 1±1 2 1.48 0.000466368 1 2441 1.59 1±1 2 1.48 0.000466368 1 2480 1.36 1±1 2 1.48 0.000466368 1 2402 8DPSK 2.36 2±1 3 1.48 0.000587123 1 2441 2.00 2±1 3 1.48 0.000587123 1 2480 1.78 1±1 2 1.48 0.000466368 1 *** End of Report ***

Test Report

NOTE:ThisdocumentisissuedbyShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,thetestreportshallnotbereproducedexceptin fullwithoutpriorwrittenpermissionofthecompany.Thetestresultsapplyonlytotheparticularsample(s)testedandtothespecifictestscarried outwhichisavailableonrequestforvalidationandinformationconfirmedatourwebsite. MORLAB SHENZHENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. FL1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad, Block67,BaoAnDistrict,ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page1of 15 REPORTNo.:SZ22020281E01 TESTREPORT APPLICANT:ShanghaiZenchantElectornicsCo.,LTD PRODUCTNAME:DualBluetoothModule MODELNAME:ZEN-BDM11/ZEN-BDM11-A TRADENAME:Zenchant BRANDNAME:Zenchant STANDARD(S):ANSI/IEEEStd149-2008 RECEIPTDATE:2022-02-28 TESTDATE:2022-02-28 ISSUEDATE:2022-03-02 Editedby: : KeZhiqing(Rapporteur) Approvedby: : ChiShide(Supervisor) Testedby MORLAB SHENZHENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. FL1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad, Block67,BaoAnDistrict,ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page2of15 REPORTNo.:SZ22020281E01 DIRECTORY 1.TechnicalInformation ............................................................................................................... 3 1.1.ApplicantandManufacturerInformation ......................................................................... 3 1.2.EquipmentUnderTest(EUT)Description ........................................................................ 3 2.TestResults ................................................................................................................................. 4 2.1.AppliedReferenceDocuments ........................................................................................... 4 2.2.TestConditions ....................................................................................................................... 4 2.3.MeasurementUncertainty .................................................................................................... 4 2.4.TestResultslists .................................................................................................................... 5 AnnexAPhotographs ................................................................................................................... 7 AnnexBFigures ............................................................................................................................. 8 1.2DRadiationPattern ................................................................................................................. 8 2.3DRadiationPattern ................................................................................................................. 9 3.VSWR .......................................................................................................................................... 11 4.Impedance ................................................................................................................................. 11 5.ReturnLoss ............................................................................................................................... 12 AnnexCPhotographs ................................................................................................................. 13 AnnexDGeneralInformation ................................................................................................... 15 1.1IdentificationoftheResponsibleTestingLaboratory ................................................. 15 1.2IdentificationoftheResponsibleTestingLocation ..................................................... 15 1.3TestEquipmentsUtilized ..................................................................................................... 15 ChangeHistory VersionDateReasonforchange 1.02022-03-02Firstedition MORLAB SHENZHENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. FL1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad, Block67,BaoAnDistrict,ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page3of15 REPORTNo.:SZ22020281E01 1.TechnicalInformation Note:Providebymanufacturer. 1.1.ApplicantandManufacturerInformation Applicant:ShanghaiZenchantElectornicsCo.,LTD ApplicantAddress:Room1202,buildinga,Nobleinternational,908XiuwenRoad, MinhangDistrict,ShangHai Manufacturer:N/A ManufacturerAddress:N/A 1.2.EquipmentUnderTest(EUT)Description WirelessTypeBluetooth FrequencyN/A IMEIN/A SampleNo.1# MORLAB SHENZHENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. FL1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad, Block67,BaoAnDistrict,ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page4of15 REPORTNo.:SZ22020281E01 2.TestResults 2.1.AppliedReferenceDocuments Leadingreferencedocumentsfortesting: No.IdentityDocumentTitle 1 ANSI/IEEEStd149-2008 IEEEStandardTestProceduresforAntennas 2.2.TestConditions TestEnvironmentConditions: RelativeHumidity:25...75% Temperature:+10°Cto+30°C 2.3.MeasurementUncertainty Theuncertaintyiscalculatedusingthemethodssuggestedinthe"GuidetotheExpressionof UncertaintyinMeasurement"(GUM)publishedbyISO.Whenthetestresultisacriticalvalue,we willusethemeasurementuncertaintygivethejudgmentresultbasedonthe95%Confidence intervals. ItemMeasurementUncertainty(dB) Gain±0.5 VSWR±0.2 MeasurementUncertainty(95%ConfidenceInterval)K=2 MORLAB SHENZHENMORLABCOMMUNICATIONSTECHNOLOGYCo.,Ltd. FL1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad, Block67,BaoAnDistrict,ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page5of15 REPORTNo.:SZ22020281E01 2.4.TestResultslists 2.4.1. GainandEfficiency FrequencyGain(dBi)Efficiency(%) 2400MHz1.7031.36 2410MHz1.6030.61 2420MHz1.3528.76 2430MHz1.0927.10 2440MHz0.8726.24 2450MHz0.5124.84 2460MHz0.2423.38…

Text truncated - open the document above for the full version.

Test Report

Report No. ENB2407310122W00401R Page 1 of 65 Ver.1.0 TEST REPORT $二维码$ Product Name : Massage Chair Model Number : SY-201A, M1820X, SY-20XX FCC ID : 2BKHU-SY-201A Prepared for : Zhejiang Shuyue Health Technology Co.,ltd. Address : No.17th Xingyang Road, Furniture Garden, Wanquan Industry Base, Pingyang County, Wenzhou City, Zhejiang Province Prepared by : EMTEK (NINGBO) CO., LTD. Address : No. 8, Building 8, Lane 216, Qingyi Road, Ningbo Hi-Tech Zone, Ningbo, Zhejiang, China Tel: +86-574-27907998 Fax: +86-574-27721538 Report Number : ENB2407310122W00401R Date(s) of Tests : July 31, 2024 to August 23, 2024 Date of issue : August 31, 2024 Report No. ENB2407310122W00401R Page 2 of 65 Ver.1.0 Table of Contents 1 TEST RESULT CERTIFICATION ............................................................................................................ 3 2 EUT TECHNICAL DESCRIPTION .......................................................................................................... 5 3 SUMMARY OF TEST RESULT ............................................................................................................... 6 4 TEST METHODOLOGY .......................................................................................................................... 7 4.1 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................................................... 7 4.2 MEASUREMENT EQUIPMENT USED .................................................................................................. 7 4.3 DESCRIPTION OF TEST MODES ........................................................................................................ 9 4.4 TEST SOFTWARE ................................................................................................................................ 9 5 FACILITIES AND ACCREDITATIONS ................................................................................................. 10 5.1 FACILITIES .......................................................................................................................................... 10 5.2 LABORATORY ACCREDITATIONS AND LISTINGS ........................................................................... 10 6 TEST SYSTEM UNCERTAINTY ........................................................................................................... 11 7 SETUP OF EQUIPMENT UNDER TEST ............................................................................................... 12 7.1 RADIO FREQUENCY TEST SETUP 1 ................................................................................................ 12 7.2 RADIO FREQUENCY TEST SETUP 2 ................................................................................................ 12 7.3 CONDUCTED EMISSION TEST SETUP ............................................................................................ 14 7.4 SUPPORT EQUIPMENT ..................................................................................................................... 14 8 FREQUENCY HOPPING SYSTEM REQUIREMENTS ......................................................................... 15 8.1 STANDARD APPLICABLE .......................................................................................................................... 15 8.2 EUT PSEUDORANDOM FREQUENCY HOPPING SEQUENCE ........................................................................ 15 8.3 EQUAL HOPPING FREQUENCY USE ......................................................................................................... 16 8.4 FREQUENCY HOPPING SYSTEM .............................................................................................................. 16 9 TEST REQUIREMENTS ........................................................................................................................ 17 9.1 20DB BANDWIDTH ............................................................................................................................. 17 9.2 CARRIER FREQUENCY SEPARATION ............................................................................................. 23 9.3 NUMBER OF HOPPING FREQUENCIES ........................................................................................... 29 9.4 AVERAGE TIME OF OCCUPANCY (DWELL TIME) ............................................................................ 31 9.5 MAXIMUM PEAK CONDUCTED OUTPUT POWER ........................................................................... 34 9.6 CONDUCTED SUPRIOUS EMISSION ............................................................................................... 40 9.7 RADIATED SPURIOUS EMISSION ..................................................................................................... 47 9.8 CONDUCTED EMISSION TEST ......................................................................................................... 61 9.9 ANTENNA APPLICATION ................................................................................................................... 64 Report No. ENB2407310122W00401R Page 3 of 65 Ver.1.0 1 TEST RESULT CERTIFICATION Applicant : Zhejiang Shuyue Health Technology Co.,ltd. Address : No.17th Xingyang Road, Furniture Garden, Wanquan Industry Base, Pingyang County, Wenzhou City, Zhejiang Province Manufacturer : Zhejiang Shuyue Health Technology Co.,ltd. Address : No.17th Xingyang Road, Furniture Garden, Wanquan Industry Base, Pingyang County, Wenzhou City, Zhejiang Province EUT : Massage Chair Model Name : SY-201A, M1820X, SY-20XX Trademark : N/A Measurement Procedure Used: APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C PASS The above equipment was tested by EMTEK (NINGBO) CO., LTD.The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report i…

Text truncated - open the document above for the full version.

Contact Information

Applicant

yaoyao lin(Sales Manager)
[email protected]15381458851Fax: 15381458851

Test Firm

EMTEK (NINGBO) Co., Ltd.Tony Wei
[email protected]0086 574 27907998

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.72 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This equipment must be installed and operated to provide a separation distance of at least 20cm between the radiator and any part of the human body.