FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Optergy/
  3. 2BKJI-BW-THCO-M

2BKJI-BW-THCO-MTemperature, humidity & carbon Monoxide wall senso

Optergy
Temperature, humidity & carbon Monoxide wall senso - FCC ID 2BKJI-BW-THCO-M - Optergy
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 28, 2024
Application Purpose
Original Equipment
Date of Application
Nov 28, 2024
Equipment Note
Temperature, humidity & carbon Monoxide wall senso
Frequency Range
2402.00000000 - 2480.00000000
Company
Optergy
Country
Australia

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

OVERVIEW HARDWARE SPECIFICATIONS The BW-THCO-M is a wireless temperature, humidity and CO sensor for use in indoor environments for monitoring control. The sensor works with the suite of Optergy Air sensors when connected to an Optergy Air Transceiver (BG-1100-M). Up to seven (7) sensors can be connected to one Optergy Air Transceiver (BG-1100-M). TemperatureHumidity Quick & Easy Installation Long-lasting Battery Powered CO Sensing Technology Temperature Accuracy Temperature Resolution Relative Humidity Accuracy Relative Humidity Resolution CO Accuracy CO Range 0 to 1,000 ppm CO Resolution < 0.1 ppm Battery Life > 5 yea rs (low battery indicato r) Data Interval Battery Type Radio Frequency Working Voltage Working Current Standby Current Scope of Appli cation Detection Range Working Temperature Transmission Distance Dimensions Weight Model Number Semiconductor based sensor - digital humidity and CO sensor with built-in temperature sensor ± 0.2°C / ± 0.36°F (typical) 14 bits ± 2% (typical) 11 bits ± 2% 4 x 1.5V alkaline (AA) or 4 x 3.6V lithium battery 2.4 GHz 3.3V Average < 1mA (BLE) < 3uA Indoor use Ambient temperature -40°C to 60°C / -40°F to 140°F and humidity 0 to 95% (without condensation) -20°C to 60°C / -4°F to 140°F 10 to 30 meters / 32 to 100 feet indoor 30 to 50 meters / 100 to 164 feet outdoor W 78mm (3 in.) x L 128 mm (5 in.) x H 29 mm (1.1 in.) 73 grams (16 pounds) BW-THCO-M (Temperature, Humidity and CO, Multi) FCC & CE: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interfer- ence that may cause undesired operation. No hidden fees As a wireless sensor, there are no power or signal cables to run. The sensor uses standard and easily replaceable AA batteries with reliable usage for up to 5 years. The battery life is viewable within the Optergy ecosystem. No special software license needed to operate. 5 minutes (CO) if using 1.5v batteries, or 1 minute if using 3.6v batteries. 5 seconds (Temperature & Humidity) Wireless Temperature, Humidity and CO Sensor (BW-THCO-M) Up to seven BW-THCO-M wireless sensors can be connected to one BG-1100-M transceiver. Multi-sensor Connectivity Wireless Multi-sensor Connectivity 3 in (78mm) 5 in (128mm) TOP FRONT 1.1in (29mm) DIMENSIONS The BW-THCO-M device requires four AA batteries (not included). We recommend using high-quality, leak-proof alkaline batteries for optimal performance. Although the product will function with regular, good-quality alkaline batteries, the best performance can be achieved by using good-quality lithium batteries with a voltage of either 1.5V or 3.6V. *Rechargeable batteries are not reccomended. ACCESSORIES (BY OTHERS) AA Batteries (1.5V or 3.6V) The sensor poi nt s (te mperature, humidity & CO level) are instant iate d by the Opte rg y P864. These points are reserved for wireless sensors and will have BACnet values corresponding to the device instance of the Optergy P864. The reserved points include: Temperature Value (Deg F or Deg C) Humidity Value (%rH) Carbon Monoxide Value (ppm) Batte ry Level Low Batte ry Level Warni ng Sensor Online Sensor Paired BACNET POINTS Optergy | www.optergy.com | [email protected] BW-THCO-M-DSRev1.0 © 2021-2023 OptergyAll specifi cations are subject to change without notice. The Optergy Air BW-THCO-M sensor pairs with the Optergy Air Transceiver (BG-1000-M). Up to seven (7) Optergy Air BW-THCO-M sensors can be connected to one Optergy Air Transceiver (BG-1000-M). Alternatively, the Optergy Air BW-THCO-M sensor can be connected to the Optergy Air Transceiver (BG-1000-M) in an ecosystem with a mixture of other Optergy Air sensors for a total of seven (7) Optergy Air sensors per one (1) Optergy Air Transceiver (BG-1000-M). When used in conjunction with the P864 and the BG-1000-M, this device will transmit space temperature, humidity, and carbon monoxide values to the BACnet system. The data points for these values are associated with the connected device. The following BACnet points are included: Power and Communication Optergy Air Transceiver (BG-1000-M) Wireless Optergy Air Temperature, Humidity & CO Sensor (BW-THCO-M) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure statement The device has been evaluatec to meel general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: REP America LLC FRN: 0034192500 Contact Name: Ben XU Address: 1942 Broadway St. STE 314C Boulder, CO 80302 United States Telephone No: (719) 201-3314 Email: [email protected] Applicant: Company name: OPTERGY Grantee code: 2BKJI FCC ID: 2BKJI-BW-THCO-M FRN : 0035857101 Contact Name: Yining Dong Address: 21-29 Miles Street, Mulgrave, Victoria 3170 Telephone: (03) 9918 7777 Fax: (03) 9918 7777 E-mail: [email protected] [OPTERGY] certifies that, as of the date of this filing of the application with the TCB, [REP America LLC] is our designated US agent for service of process for the above referenced FCC ID. [OPTERGY] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [REP America LLC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/11/27 Applicant’s Name: Yining Dong US Agent for Service of Process’s Name: Ben XU Title: Manager Title: Manager Signature Signature

Attestation Statements

Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: OPTERGY Grantee code: 2BKJI FCC ID: 2BKJI-BW-THCO-M FRN : 0035857101 Contact Name: Yining Dong Address: 21-29 Miles Street, Mulgrave, Victoria 3170 Telephone: (03) 9918 7777 Fax: (03) 9918 7777 E-mail: [email protected] i. [OPTERGY] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [OPTERGY] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [OPTERGY] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2024/11/27 Applicant’s Name: Yining Dong Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Cover Letter(s)

OPTERGY 1/1 Letter of Authorization Company: OPTERGY Address: 21-29 Miles Street, Mulgrave, Victoria 3170 Product Name: Temperature, humidity & carbon Monoxide wall senso Model Number: BW-THCO-M FCC Identifier: 2BKJI-BW-THCO-M We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Yining Dong Date: 2024-11-27 Title: Manager Signature of applicant:

Cover Letter(s)

OPTERGY 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-11-27 Subject: Request for Confidentiality FCC ID: 2BKJI- BW-THCO-M To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual No ☐ Internal Photos No ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yining Dong Title: Manager

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size:20*8mm M/N: BW-THCO-M FCC ID: 2BKJI- BW-THCO-M Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. ANT Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

RF Exposure Info

FCC ID: 2BKJI- BW-THCO-M RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=E Meas +20log(d Meas )-104.7 EIRP is the equivalent isotropically radiated power, in dBm E Meas is the field strength of the emission at the measurement distance, in dBμV/m d Meas is the measurement distance, in m Here, Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Frequency (MHz) Min. distance(mm) Calc. thresholds limit 84.34 -10.82 0.08 2480 5 0.03 3.0 So a SAR test is not required

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-241120002ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 23 FCC Part 15C Test Report FCC ID: 2BKJI- BW-THCO-M Applicant: OPTERGY Address: 21-29 Miles Street, Mulgrave, Victoria 3170 Manufacturer: ZHUHAI HONGHUI TECHNOLOGY CO.,LTD Address: Zone B 4th Floor No.611 Huawei Road, Xiangzhou District 519180 ZHUHAI GUANGDONG EUT: Temperature, humidity & carbon Monoxide wall senso Trade Mark: N/A Model Number: BW-THCO-M Date of Receipt: Nov. 11, 2024 Test Date: Nov. 11, 2024 - Nov. 22, 2024 Date of Report: Nov. 22, 2024 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China Applicable Standards: FCC PART 15 C 15.249 ANSI C63.10:2013 Test Result: Pass Report Number: DL-241120002ER Prepared (Test Engineer): Ken Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-241120002ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 23 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 6 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 7 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 7 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 8 3 . EMC EMISSION TEST 9 3.1 CONDUCTED EMISSION MEASUREMENT 9 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 9 3.1.2 TEST PROCEDURE 9 3.1.3 DEVIATION FROM TEST STANDARD 9 3.1.4 TEST SETUP 10 3.1.5 EUT OPERATING CONDITIONS 10 3.1.6 TEST RESULTS 10 3.2 RADIATED EMISSION MEASUREMENT 11 3.2.1 RADIATED EMISSION LIMITS 11 3.2.2 TEST PROCEDURE 12 3.2.3 DEVIATION FROM TEST STANDARD 12 3.2.4 TEST SETUP 12 3.2.5 EUT OPERATING CONDITIONS 13 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 14 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 15 3.2.8 TEST RESULTS (1GHZ~25GHZ) 17 3.3 RADIATED BAND EMISSION MEASUREMENT 18 3.3.1 TEST REQUIREMENT: 18 3.3.2 TEST PROCEDURE 18 3.3.3 DEVIATION FROM TEST STANDARD 18 3.3.4 TEST SETUP 19 3.3.5 EUT OPERATING CONDITIONS 19 4 . BANDWIDTH TEST 21 4.1 APPLIED PROCEDURES / LIMIT 21 4.1.1 TEST PROCEDURE 21 4.1.2 DEVIATION FROM STANDARD 21 4.1.3 TEST SETUP 21 4.1.4 EUT OPERATION CONDITIONS 21 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-241120002ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 23 Table of Contents Page 4.1.5 TEST RESULTS 22 5 . ANTENNA REQUIREMENT 23 5.1 STANDARD REQUIREMENT 23 5.2 EUT ANTENNA 23 6 . TEST SEUUP PHOTO 23 7 . EUT PHOTO 23 Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-241120002ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 23 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.249) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.205(a), 15.209(a) 15.249(a), 15.249(c) Fundamental &Radiated Spurious Emission Measurement PASS 15.249(d) Band Edge Emission PASS 15.215(c) 20dB Bandwidth PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 20dB Bandwidth ±0.2MHz Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-241120002ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 23 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: Temperature, humidity & carbon Monoxide wall senso Trademark N/A Model No.: BW-THCO-M Model Difference N/A Operation Frequency: 2402~2480MHz Channel numbers: 40 Channels Channel separation: 2M Modulation technology: GFSK Antenna Type: Internal Antenna Antenna gain: 1dBi Power supply: DC 6V from battery Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 3. Channel List Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 00 2402 14 2430 27 2456 01 2404 15 2432 28 2458 02 2406 16 2434 29 2460 03 2408 17 2436 30 2462 04 2410 18 2438 31 2464 05 2412 19 2440 32 2466 06 2414 20 2442 33 2468 07 2416 21 2444 34 2470 08 2418 22 2446 35 2472 09 2420 23 2448 36 2474 10 2422 24 2450 37 2476 11 2424 25 2452 38 2478 12 2426 26 2454 39 2480 13 2428 / / / / Shenzhen DL Testing Technology Co., Ltd. Report No.: DL-241120002ER Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 6 of 23 2.2 DESCRIPTION OF TEST MODES Note: (1) The measurements are performed at the highest, middle, lowest available channels. (2) A new fully charged battery was used for testing during the test. 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Radiated Spurious Emission Test To investigate the maximum EMI emission …

Text truncated - open the document above for the full version.

Test Report

Antenna Describe Antenna Internal Antenna Antenna Gain 1dBi Frequency Range 2.4Ghz-2.483Ghz Connector Type Direct Manufacture ZHUHAI HONGHUI TECHNOLOGY CO.,LTD Address: Zone B 4th Floor No.611 Huawei Road, Xiangzhou District 519180 ZHUHAI GUANGDONG 2.Antenna View Drawing Picture of antenna

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

Yining Dong
[email protected](03) 9918 7777Fax: (03) 9918 7777

Technical Contact

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]400-688-3552

Shenzhen, Guangdong · China

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]400-688-3552

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Optergy

2BKJI-AXON

AXON

Feb 01, 2026

Equipment Class

PCB - PCS Licensed Transmitter
eSense Interface Sensor - FCC ID 2BKJI-BW-INT-M - Optergy
2BKJI-BW-INT-M

eSense Interface Sensor

Sep 22, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter