FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. dongguanshiyuzhimingkejiyouxiangongsi/
  3. 2BKMG-AMA006012YK

2BKMG-AMA006012YKTreadmill remote control

dongguanshiyuzhimingkejiyouxiangongsi
Treadmill remote control - FCC ID 2BKMG-AMA006012YK - dongguanshiyuzhimingkejiyouxiangongsi
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 26, 2024
Application Purpose
Original Equipment
Date of Application
Sep 26, 2024
Equipment Note
Treadmill remote control
Frequency Range
434.00000000 - 434.00000000
Company
dongguanshiyuzhimingkejiyouxiangongsi
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Caution! Please read this manual carefully before using the prod- uct and take care follow issues: This treadmill should be used indoor, do not let this product be soaked and keep it away water, do not put other things on the treadmill. Please take the proper sports gear and do warming up before use the treadmill, do not use the treadmill on bare feet. Power plug must be grounded and use dedicated circuit, do not share circuit with other electric equipment. Kids should stay away from the treadmill to avoid unexpected situation. Do not use the tread mill overload and over time, or the motor, control panel, bearing ,running belt and board’s life will be greatly shorten. Should do the regular maintenance to keep tread mill in good state. Reduce dust and keep certain humidity indoor to prevent elec- tronic and control devices from interference by static electricity. Please turn off the treadmill after using. Please stop doing exercise if you feel uncomfortable and consult your doctor. Please keep the silicone oil away from kid after using to avoid eating accident. Warning: To avoid accident and injured, please follow bellowing issues: Please check your sport gear and make sure the zipper is lock. Do not wear cloth which is easy to be hooked by treadmill. Do not put the power cord near heat source. Do not use the treadmill outdoor. Must unplugged the treadmill before moving it. Only one person use it at one time, do not use it with two people and more. Please stop doing exercise if you feel dizzy, Chest pain, nausea, or shortness of breath, and consult your fitness coach or doctor. Warning! Must follow! Please consult your doctor if you are under therapy or have any one of following issues: 1. If you are suffering waist pain or hurt leg, waist or neck before, or have perceived obstacle to leg, waist , neck and hand( also include disc herniation, Spondylolisthesis, Cervical protrusion) 2. Deformed arthritis, rheumatism, gout 3. Osteoporosis or bone abnormality 4. Circulatory system disorder(heart disease, vascular disease, high blood pressure) 5. Respiratory organs disorder 6. Implant cardiac pacemaker or other electronic equipment 7. Malignant tumor 8. Thrombosis, serious arterial lipoma, acute venous lipoma and other blood circulation disease or skin infections 9. Perceived obstacle caused by diabetes 10. Wounded on skin 11. Sick or fever(38°C or higher temperature) 12. Spine abnormality or bending 13. Pregnant women or women are in the menstrual period 14. Unhealthy and need rest 15. Obvious bad condition 16. For physical recovery purpose 17. Other bad feeling expect above situations All issues above may cause unexpected condition and may harm body. Please stop doing exercise if you feel waist pain, dizzy, Palpitations or other abnormal feeling, consult your fitness coach or doctor. Forbidden Never use if you found the shell is broken and off (inside parts are exposed) or welding point is broken. Or it may cause unexpected condition. Never jump on and off the product when you are using, it may cause falling and injured. Never store the product out door, near bathroom or any place where is damp. Never use or store the product under direct sunlight, near stove, electric blanket or other heating supply equipment, or it may cause electric shock or fire accident. Never use the product when you found power cord or plug is broken or socket slack, or it may cause electric shock, short circuit or fire accident. Never break or twist the power cord, also never put things on the wire to avoid electric shock or fire accident. Never use the product with two or more people at the same time, keep others way when using the product, or it may cause unex- pected situation or falling accident. Never use the product if user can not express self conscious or can not operate the product by himself/herself. Or it may cause unexpected situation. Keep the product away water or other liquid, especially the main base. Or it may cause electric shock or fire accident. Never do intense exercise if you don’t exercise usually. Do not use it after meal, fatigue, or other uncomfortable state, or it may be harm to your health. Never use the product if you are eating or doing other behavior, also never use it after drinking, or it may cause accident or injured. Do not use it when feeling sluggish after drinking alcohol, as it may lead to accidents or injuries. Never take your watch, bracelet, mobile phone and other valuable objects with you to avoid damage, also take off your keys and knife to avoid hurting yourself. Please do check the power cord whether there is needle, garbage or other wet things before using to avoid electric shock, short circuit or fire accident. Never touch the plug with wet hand to avoid electric shock. Please turn the power switch to off position and unplug the prod- uct if do not use it for a period to avoid electricity shock or fire accident caused by insulation deterioration. Grounding explanation This product must be grounding, it can greatly reduce the risk of electricity shock when the product is dysfunction. The plug of this product is grounding standard, please use local legal grounding power source to connect the product Dangerous It may cause electricity shock if the product is not grounding prop- erly. Please ask professional electrician to check if you are not sure whether the grounding is correct. Never modify the plug if it can not fit your power source, please ask professional electrician to install a proper power source. Never use transfer plug, this product must connect to power source with grounding function. TREADMILL-WOODEN WALKING PAD Treadmill user's manual Caution! Please read this manual carefully before using the prod- uct and take care follow issues: This treadmill should be used indoor, do not let this product be soaked and keep it away water, do not put other things on the treadmill. Please take the proper sports gear and do warming up before use the treadmill, do not use th…

Text truncated - open the document above for the full version.

Attestation Statements

2.911(d)(5)(i)EquipmentTypeAttestationv1.2 dongguanshiyuzhimingkejiyouxiangongsi Section2.911(d)(5)(i)Certification–EquipmentType Companyname:dongguanshiyuzhimingkejiyouxiangongsi Address:yangguanghaian1dong1727shiwanjiangduan28haozhiyiwanjiangjiedaowandaolu guangdongshengdongguanshi ProductName:Treadmillremotecontrol FCCID:2BKMG-AMA006012YK Model(s):AMA006012YK ; AMA005958YK ; AMA005990YK ; AMA005992YK 2.911(d)(5)(i)EquipmentType We,[dongguanshiyuzhimingkejiyouxiangongsi](“theapplicant”)certifythattheequipmentforwhich authorizationissoughtthroughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name: caozhi Date:September14,2024 TitleandCompanyname:Manager/dongguanshiyuzhimingkejiyouxiangongsi NOTE1 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

2.911(d)(5)(ii)ApplicantAttestationv1.2 dongguanshiyuzhimingkejiyouxiangongsi Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:dongguanshiyuzhimingkejiyouxiangongsi Address:yangguanghaian1dong1727shiwanjiangduan28haozhiyiwanjiangjiedaowandaolu guangdongshengdongguanshi ProductName:Treadmillremotecontrol FCCID:2BKMG-AMA006012YK Model(s):AMA006012YK;AMA005958YK;AMA005990YK;AMA005992YK 2.911(d)(5)(ii)Applicantfiling We,[dongguanshiyuzhimingkejiyouxiangongsi](“theapplicant”)certifythat,asofthedateofthefiling oftheapplication,theapplicantisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,established pursuantto§1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name: caozhi Date:September14,2024 TitleandCompanyname:Manager;ShenzhenVanpowersIntelligentTechnologyCo.,Ltd. NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

dongguanshiyuzhimingkejiyouxiangongsi 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:dongguanshiyuzhimingkejiyouxiangongsi Address:yangguanghaian1dong1727shiwanjiangduan28haozhiyiwanjiangjiedao wandaoluguangdongshengdongguanshi ProductName:Treadmillremotecontrol FCCID:2BKMG-AMA006012YK Model(s):AMA006012YK;AMA005958YK;AMA005990YK;AMA005992YK 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[changshajiuhuidianzishangwuyouxiangongsi](“theapplicant”)designate [PAGACATINC] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfofthe applicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:PAGACATINC USAAddress:99WASHINGTONAVE SUITE805-D,ALBANY,NEWYORK, UnitedStates12210 FRNNumber:0033564972 ContactName:ZhangHaiyan TelephoneNo:(973)386-5980 Email:[email protected] Applicant Company name: dongguanshiyuzhimingkejiyouxiangongsi Address: yangguanghaian1dong1727shi wanjiangduan28haozhiyiwanjiangjiedao wandaoluguangdongshengdongguanshi GranteeFRNNumber:0035872647 FCCGranteeCode:2BKMG ContactName: caozhi TelephoneNo: 19129988771 Email: [email protected] dongguanshiyuzhimingkejiyouxiangongsi 2.911(d)(7)USAAgentv1.5 Signature: Title:Manager Signature: Title:Manager Date:2024/09/11Date:2024/09/11 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

dongguanshiyuzhimingkejiyouxiangongsi AgentAuthorization Company:dongguanshiyuzhimingkejiyouxiangongsi Address:yangguanghaian1dong1727shiwanjiangduan28haozhiyiwanjiangjiedao wandaoluguangdongshengdongguanshi ProductName:Treadmillremotecontrol ModelNumber(s):2BKMG-AMA006012YK ProductDescription:AMA006012YK;AMA005958YK;AMA005990YK; AMA005992YK WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:September14,2024 Name: caozhi Title:Manager Company:dongguanshiyuzhimingkejiyouxiangongsi

Cover Letter(s)

<dongguanshiyuzhimingkejiyouxiangongsi> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:September14,2024 Subject;RequestforLongTermConfidentiality FCCID:2BKMG-AMA006012YK ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,weare requestingtheCommissiontowithholdthefollowingattachment(s)asconfidentialdocumentsfrom publicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredasproprietary informationinoperationoftheequipment.Thepublicdisclosureofthesedocumentsmightbeharmfulto ourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatandcorrespondenceduring thecertificationreviewprocesscannotbegrantedasconfidentialdocumentsandthisinformationwillbe availableforpublicreviewoncethegrantofequipmentauthorizationisissued. Sincerely, Signature: Name:caozhi Title:Manager

Cover Letter(s)

dongguanshiyuzhimingkejiyouxiangongsi ModelDifferenceDeclaration ToWhomItMayConcern, We,dongguanshiyuzhimingkejiyouxiangongsi Productname:Treadmillremotecontrol Tradename:FUNMILY,ANCHEER,SYTIRY,KRISRATE Modelname:AMA006012YK,AMA005958YK, AMA005990YK,AMA005992YK Allmodel’sthefunction,softwareandelectriccircuitarethesame,onlywith modelnameddifferent.Testsamplemodel:AMA006012YK Pleasecontactmeifyouhaveanyquestion. Name:caozhi Date:September14,2024 Title:Manager Signatureofapplicant:

External Photos

Mod el: AMA006012YK Mod el: AMA006012YK Mod el: AMA006012YK

ID Label/Location Info

Labelandlocation ModelNo.:AMA006012YK FCCID:2BKMG-AMA006012YK Size : 15X30MM

Internal Photos

Mod el: AMA006012YK Mod el: AMA006012YK Mod el: AMA006012YK Mod el: AMA006012YK PCB ANT

RF Exposure Info

MPEESTIMATION FCCID:2BKMG-AMA006012YK 1.LimitforPortableEquipmentExposure Frequency1-gSAR 100MHz-6GHz3.0 Accordingto447498D01GeneralRFExposureGuidancev06 The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤ 50 mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)] • [ √ f(GHz)] ≤ 3.0for1-gSARand ≤ 7.5for10-gextremitySAR. Wheref(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation 2.EstimationResult Frequency Reading result(dBμV/m) PKOutput Power(dBm) Output Power(mW) Test Separation Distance(mm) Measurement Result 1-gSAR ASK 434MHz 72.94-22.260.00650.00083.0 Note:PKOutputPower(dBm)=Readingresult(dBμV/m)-95.2 ReadingresultseethetestreportUNIA24090902ER-61. TheSARevaluationisnotrequired. ------TheEnd------

Test Report

Page 1 of 22 Report No.: UNIA24090902ER-61 FCC RADIO TEST REPORT FCC ID: 2BKMG-AMA006012YK Sample : Treadmill remote control Trade Mark : FUNMILY, ANCHEER, SYTIRY, KRISRATE Main Model : AMA006012YK Additional Model : AMA005958YK, AMA005990YK AMA005992YK Report No. : UNIA24090902ER-61 Prepared for dongguanshiyuzhimingkejiyouxiangongsi yangguanghaian 1dong 1727shi wanjiangduan 28haozhiyi wanjiangjiedao wandaolu guangdongsheng dongguanshi Prepared by Shenzhen United Testing Technology Co., Ltd. D101&D401, No. 107, Kaicheng High-Tech Park, Taoyuan Community, Dalang Sub-District, Longhua District, Shenzhen, Guangdong, China Page 2 of 22 Report No.: UNIA24090902ER-61 TEST RESULT CERTIFICATION Applicant ............................... : dongguanshiyuzhimingkejiyouxiangongsi Address .................................. : yangguanghaian 1dong 1727shi wanjiangduan 28haozhiyi wanjiangjiedao wandaolu guangdongsheng dongguanshi Manufacturer ........................ : Ningbo Jiufeng Electrical Appliance Co., Ltd. Address .................................. : No.268 Binhai road,Binhai New Area, FengHua economic development zone,Ningbo,Zhejiang,China Product description Product................................... : Treadmill remote control Trade Mark ............................. : FUNMILY, ANCHEER, SYTIRY, KRISRATE Model Name ........................... : AMA006012YK,AMA005958YK,AMA005990YK ,AMA005992YK Test Methods ........................ : FCC Part 15 Subpart C 15.231 ANSI C63.10: 2013 This device described above has been tested by Shenzhen United Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of UNI, this document may be altered or revised by Shenzhen United Testing Technology Co., Ltd., personne l only, and shall be noted in the revision of the document. Date of Test Date (s) of performance of tests ........... : September 09, 2024 ~ September 11, 2024 Date of Issue ........................................ : September 11, 2024 Test Result ........................................... : Pass Prepared by: Jason Ye/Editor Reviewer: Kelly Cheng/Supervisor Approved & Authorized Signer: Liuze/Manager Page 3 of 22 Report No.: UNIA24090902ER-61 Table of Contents Pages 1 TEST SUMMARY ................................................................................................................................. 4 1.1 TEST PROCEDURES AND RESULTS ......................................................................................... 4 1.2 TEST FACILITY ............................................................................................................................. 5 1.3 MEASUREMENT UNCERTAINTY ................................................................................................ 6 2 GENERAL INFORMATION .................................................................................................................. 7 2.1 GENERAL DESCRIPTION OF EUT .............................................................................................. 7 2.2 CARRIER FREQUENCY OF CHANNELS .................................................................................... 8 2.3 OPARATION OF EUT DURING TESTING .................................................................................... 8 2.4 DESCRIPTION OF TEST SETUP ................................................................................................. 8 2.5 ENVIRONMENTAL CONDITIONS ................................................................................................ 8 2.6 MEASUREMENT INSTRUMENTS LIST ....................................................................................... 9 3 CONDUCTED EMISSIONS TEST ..................................................................................................... 10 4 RADIATED EMISSION TEST ............................................................................................................ 11 5 -20DB OCCUPIED BANDWIDTH ...................................................................................................... 18 6 DEACTIVATION TIME ....................................................................................................................... 19 7 ANTENNA REQUIREMENT .............................................................................................................. 20 8 PHOTOGRAPH OF TEST .................................................................................................................. 21 9 EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS) ...................................................................... 22 Page 4 of 22 Report No.: UNIA24090902ER-61 1 TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS FCC Requirements FCC Part 15.207 Conducted Emission N/A FCC §15.231(a)(1) Automatically Deactivate PASS FCC §15.231 Duty Cycle PASS FCC Part 15.231(b) Electric Field Strength of Fundamental Emission PASS FCC Part 15.205 &15.209& 15.231(b) Electric Field Strength of Spurious Emission PASS FCC Part 15.231(c) -20dB bandwidth PASS Page 5 of 22 Report No.: UNIA24090902ER-61 1.2 TEST FACILITY Test Firm : Shenzhen United Testing Technology Co., Ltd. Address : D101&D401, No. 107, Kaicheng High-Tech Park, Taoyuan Community, Dalang Sub-District, Longhua District, Shenzhen, Guangdong, China The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19.The testing quality system of our laboratory meets with ISO/IEC-17025 requirements. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: A2LA Certificate Number: 4747.01 The EMC Laboratory has been accredited by A2LA, and in compliance with ISO/IEC 17025:2017 General Requirements for testing Laboratories. FCC Registration Numb…

Text truncated - open the document above for the full version.

Test Setup Photos

Model:AMA006012YK RadiatedEmission 30MHz-1000MHz Above1GHz

Contact Information

Applicant

Zhi Cao
[email protected]1912998877Fax: 1912998877

Technical Contact

dongguanshiyuzhimingkejiyouxiangongsi
[email protected]

China

Test Firm

Shenzhen United Testing Technology Co., Ltd.Ze Liu
[email protected]86-755-86180996

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231434 MHz - 434 MHz-
Confidentiality
Long Term