2BKNU-FX2220fanxiang Cloud Mobile Phone

Shenzhen Lingdechuang Technology Co., Ltd.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 22, 2025
Application Purpose
Original Equipment
Equipment Note
fanxiang Cloud Mobile Phone
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Lingdechuang Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

1 |P a g e Shenzhen Lingdechuang Technology Co., Ltd. 701, Building A, Ruziniu Building, Bantian Street, Longgang District, Shenzhen, 518110 China Attestation Statements To: FederalCommunicationsCommissionDate: Dec. 18, 25 7435 OaklandMills Road, Columbia,MD 21046,USA Subject:Attestationof Compliancewith FCC CoveredList SoftwareRequirements FCC ID:2BKNU-FX2220 ProductName:fanxiangCloud MobilePhone This letter servesas an attestationthat the equipmentidentifiedaboveis not(selectone) "covered"software as definedunder the FederalCommunicationsCommission(FCC) CoveredList requirements,as outlined inFCC 22-84andKDB 986446. Specifically,the undersignedcertifiesthat the equipmentfor which authorizationis sought: 1.Does not containcybersecurityor anti-virussoftwareproducedor providedbyKasperskyLab, Inc.or any of its successors,assignees,parents,subsidiaries,affiliates,or any entity that has rebranded or relabeledsoftwareproducedby the aforementionedentities. 2.Does not have the capabilityto store, run, or deliverany softwareidentifiedon the FCC CoveredList, includingbut not limitedto cybersecurityand anti-virussoftware. To supportthis attestation,the appendixevaluationdocumentationhas been preparedand is includedin the certificationfiling. This attestationis based on a thoroughevaluationof the device'sdesign,functionality,and software environment.The undersignedaffirmsthat the informationprovidedis accurateand completeto the best of their knowledge. Sincerelyyours, PrintedName:GuoFenWei Title: Productmanager Address:701, BuildingA, RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China Tel.: 15899789041 Email: [email protected] ShenzhenLingdechuangTechnologyCo.,Ltd. 706,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Attestation Statements

ShenzhenLingdechuangTechnologyCo.,Ltd. 701,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:12/18/2025 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BKNU-FX2220 ShenzhenLingdechuangTechnologyCo.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication, theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002ofreference chapter,asanentityproducing“covered”communicationequipment.Theequipmentforwhich authorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, PrintedName:GuoFenWei Title:Productmanager Address:701,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China Tel.:15899789041 Email:[email protected]

Attestation Statements

ShenzhenLingdechuangTechnologyCo.,Ltd. 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:ShenzhenLingdechuangTechnologyCo.,Ltd. Address:706,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict, Shenzhen,518110China FCCID:2BKNU-FX2220 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ShenzhenLingdechuangTechnologyCo.,Ltd.]designate[LinkwldLLC] NOTE1 for thepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgentApplicant Companyname:LinkwldLLCCompanyname:ShenzhenLingdechuang TechnologyCo.,Ltd. USAAddress:7595TechnologyWaySte 100,Denver,CO80237,US Address:706,BuildingA,RuziniuBuilding, BantianStreet,LonggangDistrict, Shenzhen,518110China FRNNumber:0033625682GranteeFRNNumber:0035881879 ContactName:TimothyZhuFCCGranteeCode:2BKNU TelephoneNo:(747)717-2691ContactName:GuoFenWei Email:[email protected]:15899789041 Email:[email protected] Signature: Signature: ShenzhenLingdechuangTechnologyCo.,Ltd. 2.911(d)(7)USAAgentv1.5 Title:ManagerTitle:Productmanager Date:2025-12-15Date:2025-12-15 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

ShenzhenLingdechuangTechnologyCo.,Ltd. 701,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China 12/18/2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BKNU-FX2220 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow:  BlockDiagram Schematics  OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof(upto180)daysfromthedateofequipmentauthorizationandpriorto marketingintheUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantis awareoftheirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductorthe productismadeavailabletothepublicbeforetherequestedperiodhasexpired. UserManual  InternalPhotos ExternalPhotos  TestSetupPhotos Sincerely, Title:Productmanager Address:701,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China Tel.:15899789041 Email:[email protected]

Cover Letter(s)

ShenzhenLingdechuangTechnologyCo.,Ltd. 701,BuildingA,RuziniuBuilding,BantianStreet,LonggangDistrict,Shenzhen,518110China 2025/12/15 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BKNU-FX2220 I,theundersigned,herebyauthorize(ShenzhenAnbotekComplianceLaboratoryLimited.)toactonour behalfinallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenAnbotekComplianceLaboratoryLimited.)shallhavethesameeffectas ourownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsof certification,asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(Shenzhen LingdechuangTechnologyCo.,Ltd.). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, PrintedName:GuoFenWei Title:Productmanager Tel.:15899789041 Fax:N/A Email:[email protected]

ID Label/Location Info

LabelLocation Labelsize: ( L:7cm*W:1.5cm ) ProductName:fanxiangCloudMobilePhone ModelNo.:FX2220 FCCID:2BKNU-FX2220

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2BKNU-FX2220 AccordingtoKDB447498D01MobileandPortableDevicesRFExposureProcedures andEquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationas specifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnotrequired, portabletransmitterswithoutputpowergreaterthantheapplicablelowthresholdrequire SARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 24025.345.34±16.34051.3343 GFSK24414.994.99 ±1 5.99051.2413 24805.095.09±16.09051.2803 24026.006.00±17.00051.5543 π/4-DQPSK24415.775.77 ±1 6.77051.4853 24805.825.82±16.82051.5143 24026.276.27±17.27051.6533 8DPSK24416.076.07 ±1 7.07051.5923 24806.046.04±17.04051.5933 24027.227.22±18.22052.0573 GFSK24406.086.08 ±1 7.08051.5953 24806.556.55±17.55051.7923 24027.367.36±18.36052.1253 GFSK24406.226.22 ±1 7.22051.6473 24806.676.67±17.67051.8423 24128.078.07 ±1 9.07052.5073DSSS 52406.456.45±17.45052.5453OFDM 53206.356.35±17.35052.5063OFDM 55006.266.26 ±1 7.26052.4963OFDM 58256.076.07±17.07052.4593OFDM TheMaximumsimultaneoustransmissionforWLAN_2.4G+RLAN_5G: =S WLAN_2.4G /S limit +SRLAN_5G/S limit =2.507/7.5+2.545/7.5 =0.6736 <1.6 Result:NoStandaloneSARtestisrequired.

Test Report

Page 1 of 40 FCC Test Report Report No.:1812C50578612501 Applicant:Shenzhen Lingdechuang Technology Co., Ltd. Address: 701, Building A, Ruziniu Building,Bantian Street, Longgang District, Shenzhen 518110 China Product Name:Fanxiang Cloud Mobile Phone Report Date:2025-12-18 Shenzhen Anbotek Compliance Laboratory Limited #检测章# #资质章# Report No.:1812C50578612501Page 2 of 40 FCC ID: 2BKNU-FX2220 Contents 1. General Information...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT)........................................................................................................6 1.3. Auxiliary Equipment Used During Test .......................................................................................7 1.4. Operation channel list .................................................................................................................8 1.5. Description of Test Modes ..........................................................................................................8 1.6. Measurement Uncertainty ...........................................................................................................9 1.7. Additional Instructions .................................................................................................................9 1.8. Test Summary ...........................................................................................................................10 1.9. Description of Test Facility ........................................................................................................11 1.10. Disclaimer................................................................................................................................11 1.11. Test Equipment List ................................................................................................................12 2. Antenna requirement ...........................................................................................................................14 2.1. Conclusion.................................................................................................................................14 3. Conducted Emission at AC power line ................................................................................................15 3.1. EUT Operation ..........................................................................................................................15 3.2. Test Setup .................................................................................................................................15 3.3. Test Data...................................................................................................................................16 4. 20dB Bandwidth ..................................................................................................................................18 4.1. EUT Operation ..........................................................................................................................18 4.2. Test Setup .................................................................................................................................19 4.3. Test Data...................................................................................................................................19 5. Maximum Conducted Output Power ...................................................................................................20 5.1. EUT Operation ..........................................................................................................................20 5.2. Test Setup .................................................................................................................................21 5.3. Test Data...................................................................................................................................21 6. Channel Separation.............................................................................................................................22 6.1. EUT Operation ..........................................................................................................................22 6.2. Test Setup .................................................................................................................................22 6.3. Test Data...................................................................................................................................22 7. Number of Hopping Frequencies ........................................................................................................24 7.1. EUT Operation ..........................................................................................................................24 7.2. Test Setup .................................................................................................................................24 7.3. Test Data...................................................................................................................................24 8. Dwell Time...........................................................................................................................................26 8.1. EUT Operation ..........................................................................................................................27 8.2. Test Setup .................................................................................................................................27 8.3. Test Data...................................................................................................................................27 9. Emissions in non-restricted frequency bands...........................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:1812C50578612501-01 Page 1 of 55 AppendixTestData ReportNo.:1812C50578612501-01TestSampleNo.:1-2-2 StartTestDate:2025-11-7FinishTestDate: TestEngineer 2025-12-18 :Auditor: Temperature:24.1°CRelativeHumidity:56% Pressure:101kPa AppendixA:20dBBandwidth TestResult Test Mode Antenna Frequency [MHz] 20db EBW[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant124021.0112401.4512402.462------ DH5Ant124411.0142440.4512441.465------ DH5Ant124801.0022479.4632480.465------ 2DH5Ant124021.2782401.3402402.618------ 2DH5Ant124411.3322440.2952441.627------ 2DH5Ant124801.3232479.3012480.624------ 3DH5Ant124021.3052401.3132402.618------ 3DH5Ant124411.2902440.3282441.618------ 3DH5Ant124801.2842479.3162480.600------ ReportNo.:1812C50578612501-01 Page 2 of 55 TestGraphs DH5-Ant1-2402 DH5-Ant1-2441 ReportNo.:1812C50578612501-01 Page 3 of 55 DH5-Ant1-2480 2DH5-Ant1-2402 ReportNo.:1812C50578612501-01 Page 4 of 55 2DH5-Ant1-2441 2DH5-Ant1-2480 ReportNo.:1812C50578612501-01 Page 5 of 55 3DH5-Ant1-2402 3DH5-Ant1-2441 ReportNo.:1812C50578612501-01 Page 6 of 55 3DH5-Ant1-2480 ReportNo.:1812C50578612501-01 Page 7 of 55 AppendixB:99%OccupiedBandwidth TestResult Test Mode Antenna Frequency [MHz] OCB[MHz]FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant124020.902022401.51072402.4127------ DH5Ant124410.899502440.50872441.4082------ DH5Ant124800.895362479.51482480.4102------ 2DH5Ant124021.19772401.36442402.5621------ 2DH5Ant124411.19082440.36862441.5594------ 2DH5Ant124801.19732479.36692480.5642------ 3DH5Ant124021.19562401.37262402.5682------ 3DH5Ant124411.18562440.37082441.5564------ 3DH5Ant124801.21262479.35462480.5672------ ReportNo.:1812C50578612501-01 Page 8 of 55 TestGraphs DH5-Ant1-2402 DH5-Ant1-2441 ReportNo.:1812C50578612501-01 Page 9 of 55 DH5-Ant1-2480 2DH5-Ant1-2402 ReportNo.:1812C50578612501-01 Page 10 of 55 2DH5-Ant1-2441 2DH5-Ant1-2480 ReportNo.:1812C50578612501-01 Page 11 of 55 3DH5-Ant1-2402 3DH5-Ant1-2441 ReportNo.:1812C50578612501-01 Page 12 of 55 3DH5-Ant1-2480 ReportNo.:1812C50578612501-01 Page 13 of 55 AppendixC:MaximumConductedOutputPower TestResultPeak Test Mode AntennaFrequency[MHz] ConductedPeak Power[dBm] Conducted Limit[dBm] Verdict DH5Ant124025.34≤20.97PASS DH5Ant124414.99≤20.97PASS DH5Ant124805.09≤20.97PASS 2DH5Ant124026.00≤20.97PASS 2DH5Ant124415.77≤20.97PASS 2DH5Ant124805.82≤20.97PASS 3DH5Ant124026.27≤20.97PASS 3DH5Ant124416.07≤20.97PASS 3DH5Ant124806.04≤20.97PASS TestGraphs DH5-Ant1-2402-PASS ReportNo.:1812C50578612501-01 Page 14 of 55 DH5-Ant1-2441-PASS DH5-Ant1-2480-PASS ReportNo.:1812C50578612501-01 Page 15 of 55 2DH5-Ant1-2402-PASS 2DH5-Ant1-2441-PASS ReportNo.:1812C50578612501-01 Page 16 of 55 2DH5-Ant1-2480-PASS 3DH5-Ant1-2402-PASS ReportNo.:1812C50578612501-01 Page 17 of 55 3DH5-Ant1-2441-PASS 3DH5-Ant1-2480-PASS ReportNo.:1812C50578612501-01 Page 18 of 55 AppendixD:Carrierfrequencyseparation TestResult TestModeAntenna Frequency [MHz] Result [MHz] Limit[MHz]Verdict DH5Ant1Hop1.002≥0.676PASS 2DH5Ant1Hop0.984≥0.888PASS 3DH5Ant1Hop1.176≥0.870PASS ReportNo.:1812C50578612501-01 Page 19 of 55 TestGraphs DH5-Ant1-Hop-PASS 2DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 20 of 55 3DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 21 of 55 AppendixE:DwellTime TestResult Test Mode Antenna Frequency [MHz] BurstWidth [ms] TotalHops [Num] Result [s] Limit [s] Verdict DH5Ant1Hop2.8851090.314≤0.4PASS 2DH5Ant1Hop2.888990.286≤0.4PASS 3DH5Ant1Hop2.892960.278≤0.4PASS ReportNo.:1812C50578612501-01 Page 22 of 55 TestGraphs DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 23 of 55 2DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 24 of 55 3DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 25 of 55 AppendixF:NumberofHoppingChannel TestResult TestModeAntenna Frequency [MHz] Result [Num] Limit [Num] Verdict DH5Ant1Hop79≥15PASS 2DH5Ant1Hop79≥15PASS 3DH5Ant1Hop79≥15PASS ReportNo.:1812C50578612501-01 Page 26 of 55 TestGraphs DH5-Ant1-Hop-PASS 2DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 27 of 55 3DH5-Ant1-Hop-PASS ReportNo.:1812C50578612501-01 Page 28 of 55 AppendixG:ConductedBandedge TestResult Test Mode Antenna Ch. Name Frequency [MHz] Ref.Level [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1Low24025.13-43.24≤-14.88PASS DH5Ant1High24805.01-49.54≤-14.99PASS DH5Ant1LowHop_24024.65-53.1≤-15.35PASS DH5Ant1HighHop_24804.70-54.19≤-15.3PASS 2DH5Ant1Low24025.11-44.3≤-14.89PASS 2DH5Ant1High24804.91-29.81≤-15.09PASS 2DH5Ant1LowHop_24024.06-49.17≤-15.94PASS 2DH5Ant1HighHop_24804.48-31.1≤-15.52PASS 3DH5Ant1Low24025.07-45.42≤-14.93PASS 3DH5Ant1High24804.92-43.81≤-15.08PASS 3DH5Ant1LowHop_24022.26-51.96≤-17.74PASS 3DH5Ant1HighHop_24804.85-52.55≤-15.15PASS

Test Report

ReportNo.:1812C50578612501-01 Page 29 of 55 TestGraphs DH5-Ant1-2402-PASS DH5-Ant1-2480-PASS ReportNo.:1812C50578612501-01 Page 30 of 55 DH5-Ant1-Hop_2402-PASS DH5-Ant1-Hop_2480-PASS ReportNo.:1812C50578612501-01 Page 31 of 55 2DH5-Ant1-2402-PASS 2DH5-Ant1-2480-PASS ReportNo.:1812C50578612501-01 Page 32 of 55 2DH5-Ant1-Hop_2402-PASS 2DH5-Ant1-Hop_2480-PASS ReportNo.:1812C50578612501-01 Page 33 of 55 3DH5-Ant1-2402-PASS 3DH5-Ant1-2480-PASS ReportNo.:1812C50578612501-01 Page 34 of 55 3DH5-Ant1-Hop_2402-PASS 3DH5-Ant1-Hop_2480-PASS ReportNo.:1812C50578612501-01 Page 35 of 55 AppendixH:ConductedSpuriousEmission TestResult Test Mode AntennaFrequency[MHz] Freq.Range [MHz] Ref.Level [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant124020~Reference4.394.39---PASS DH5Ant1240230~10004.39-56.14≤-15.61PASS DH5Ant124021000~265004.39-42.92≤-15.61PASS DH5Ant124410~Reference4.684.68---PASS DH5Ant1244130~10004.68-59.62≤-15.32PASS DH5Ant124411000~265004.68-26.09≤-15.32PASS DH5Ant124800~Reference4.424.42---PASS DH5Ant1248030~10004.42-57.77≤-15.58PASS DH5Ant124801000~265004.42-41.99≤-15.58PASS 2DH5Ant124020~Reference1.151.15---PASS 2DH5Ant1240230~10001.15-59.39≤-18.85PASS 2DH5Ant124021000~265001.15-43.35≤-18.85PASS 2DH5Ant124410~Reference3.603.60---PASS 2DH5Ant1244130~10003.60-54.2≤-16.4PASS 2DH5Ant124411000~265003.60-45.21≤-16.4PASS 2DH5Ant124800~Reference4.794.79---PASS 2DH5Ant1248030~10004.79-56.25≤-15.21PASS 2DH5Ant124801000~265004.79-42.61≤-15.21PASS 3DH5Ant124020~Reference1.501.50---PASS 3DH5Ant1240230~10001.50-59.9≤-18.5PASS 3DH5Ant124021000~265001.50-46.27≤-18.5PASS 3DH5Ant124410~Reference1.671.67---PASS 3DH5Ant1244130~10001.67-59.02≤-18.33PASS 3DH5Ant124411000~265001.67-42.68≤-18.33PASS 3DH5Ant124800~Reference1.911.91---PASS 3DH5Ant1248030~10001.91-59.13≤-18.09PASS 3DH5Ant124801000~265001.91-45.17≤-18.09PASS Remark:Regardingthespuriousemissionsfrom30MHzto26.5GHz,thecablelosshavebeensetinthe 'InputCorrection'oftheSpectrumAnalyzerduringthetest. ReportNo.:1812C50578612501-01 Page 36 of 55 TestGraphs DH5-Ant1-2402-0~Reference-PASS DH5-Ant1-2402-30~1000-PASS ReportNo.:1812C50578612501-01 Page 37 of 55 DH5-Ant1-2402-1000~26500-PASS DH5-Ant1-2441-0~Reference-PASS ReportNo.:1812C50578612501-01 Page 38 of 55 DH5-Ant1-2441-30~1000-PASS DH5-Ant1-2441-1000~26500-PASS ReportNo.:1812C50578612501-01 Page 39 of 55 DH5-Ant1-2480-0~Reference-PASS DH5-Ant1-2480-30~1000-PASS ReportNo.:1812C50578612501-01 Page 40 of 55 DH5-Ant1-2480-1000~26500-PASS 2DH5-Ant1-2402-0~Reference-PASS ReportNo.:1812C50578612501-01 Page 41 of 55 2DH5-Ant1-2402-30~1000-PASS 2DH5-Ant1-2402-1000~26500-PASS ReportNo.:1812C50578612501-01 Page 42 of 55 2DH5-Ant1-2441-0~Reference-PASS 2DH5-Ant1-2441-30~1000-PASS ReportNo.:1812C50578612501-01 Page 43 of 55 2DH5-Ant1-2441-1000~26500-PASS 2DH5-Ant1-2480-0~Reference-PASS ReportNo.:1812C50578612501-01 Page 44 of 55 2DH5-Ant1-2480-30~1000-PASS 2DH5-Ant1-2480-1000~26500-PASS ReportNo.:1812C50578612501-01 Page 45 of 55 3DH5-Ant1-2402-0~Reference-PASS 3DH5-Ant1-2402-30~1000-PASS ReportNo.:1812C50578612501-01 Page 46 of 55 3DH5-Ant1-2402-1000~26500-PASS 3DH5-Ant1-2441-0~Reference-PASS ReportNo.:1812C50578612501-01 Page 47 of 55 3DH5-Ant1-2441-30~1000-PASS 3DH5-Ant1-2441-1000~26500-PASS ReportNo.:1812C50578612501-01 Page 48 of 55 3DH5-Ant1-2480-0~Reference-PASS 3DH5-Ant1-2480-30~1000-PASS ReportNo.:1812C50578612501-01 Page 49 of 55 3DH5-Ant1-2480-1000~26500-PASS ReportNo.:1812C50578612501-01 Page 50 of 55 AppendixI:DutyCycle TestResult TestModeAntennaFrequency[MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor[dB] DH5Ant124022.903.7577.331.12 DH5Ant124412.893.7577.071.13 DH5Ant124802.883.7576.801.15 2DH5Ant124022.893.7577.071.13 2DH5Ant124412.893.7577.071.13 2DH5Ant124802.903.7577.331.12 3DH5Ant124022.893.7577.071.13 3DH5Ant124412.903.7577.331.12 3DH5Ant124802.903.7577.331.12 ReportNo.:1812C50578612501-01 Page 51 of 55 TestGraphs NTNV-DH5-Ant1-2402 NTNV-DH5-Ant1-2441 ReportNo.:1812C50578612501-01 Page 52 of 55 NTNV-DH5-Ant1-2480 NTNV-2DH5-Ant1-2402 ReportNo.:1812C50578612501-01 Page 53 of 55 NTNV-2DH5-Ant1-2441 NTNV-2DH5-Ant1-2480 ReportNo.:1812C50578612501-01 Page 54 of 55 NTNV-3DH5-Ant1-2402 NTNV-3DH5-Ant1-2441 ReportNo.:1812C50578612501-01 Page 55 of 55 NTNV-3DH5-Ant1-2480 ---End---

Test Report

FX2220天线1规格书 客户名称:深圳市领德创科技有限公司 Customer 规格描述:FX2220天线1 Partname 客户料号: CustomerPartNo 厂商名称:深圳兴邦通讯科技有限公司 Part 客户确认Customerconfirmation 确认Confirmation核实check批准Approver 制造厂商承认Manufacturerrecognition 销售代表Sales拟制Drafters核实check批准Approver 李超蒋小平张斌马沣 一天线示意图 二:天线性能: 1S11测试数据 2效率和增益 三.电缆头规格 材料及镀层 序号零件名称材质镀层备注 1内导体黄铜镀金 2绝缘体聚四氟乙烯PTFE 3壳体黄铜镀金 4镀金厚度镀金1~1.2u" 电气性能 序号检测项目技术指标备注 1特性阻抗50Ω 2温度范围-55~+155°C 3频率范围0~3GHZ 4介质耐压1000V(rms) 5接触电阻 内导体≤3mΩ 外导体≤2mΩ 6绝缘电阻≥5000MΩ 7电压驻波比≤1.25(软电缆) 四.环境实验报告: 1高低温恒湿试验 料号品名规格 试验项目高温、低温、恒湿试验 检测设备恒温恒湿试验箱测试数量 检验标准1.金属表面镀层无脱落、裂痕、起皱等不良;非金属部分不能有变色、裂痕、变 形、脱胶等现象。 试验名称试验项目要求试验方法结果判定 高温试验温度(°C) 试验样品温度时间(h) 试验持续时间(h) 恢复时间(h) 75±3 1 2 1 试验步骤: a)将被测件放入试验箱,再将 高温箱温度调到75°C±3°C,, 监控时间。 b)试验后放置常温1小时,进 行常规检验。 合格 低温试验温度(°C) 试验样品温度时间(h) 试验持续时间(h) 恢复时间(h) -40±3 1 2 1 试验步骤: a)将被测件放入试验箱,再将 低温箱温度调到-40°C±3°C,监 控时间。 b)试验后放置常温1小时,进 合格 行常规检验。 恒定湿热 试验 温度(°C) 相对湿度(%) 试验持续时间(h) 恢复时间(h) +40±3 90-95 21 1 a)将被测件放入试验箱,再将 试验箱温度调到+40°C±3°C,湿 度为90-95%,监控时间。 b)试验后放置常温1小时,进 行常规检验。 合格 检验员:陆晓君审核:王洪坤批准:肖添芳 2自由跌落测试 料号品名规格 试验项目自由跌落测试 检测设备1米高桌面测试数量 检验标准1.在1米高跌落,产品无脱落、裂痕、等不良,外观无变形等现象。 试验名称试验项目要求试验方法结果判定 自由跌落 测试 跌落高度1000mm正反面跌落 2次 试验步骤: a)将被测件在1000mm高度跌 落,试验后进行常规检验。 合格 检验员:陆晓君审核:王洪坤批准:肖添芳 3盐雾试验 料号品名规格 试验项目验雾试验 检测设备验雾测试机测试数量 检验标准1.金属表面镀层无脱落;外观无生锈、腐蚀、氧化等不良现象。 试验名称试验项目要求试验方法结果判定 盐雾试验 1.NaCl浓度: 2.空气压力: 3.PH值: 4.喷雾量: 5.盐水测试温度设定 a.试验室温度: b.压力桶温度: 6.测试时间: 40-60g/1kg 1.0±0.01kgf㎡ 6.5-7.2 1.0-2.0ml/80c/h。 35±1°C 47±1°C 24H 试验步骤: a)将盐雾试验机,调制 到相关测试条件。 b)将被测件放入盐雾 试验机,放置24小时。 试验后用清水冲洗,目 测被测件外观,进行常 规检验。 合格 检验员:陆晓君审核:王洪坤批准:肖添芳 五天线图

Contact Information

Applicant

GuoFen Wei(Product manager)
[email protected]Fax: N/A

Technical Contact

Linkwld LLCTimothy Zhu
[email protected]

7595 Technology Way Ste 100 · Denver, Colorado, 80237 · United States

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.